Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Search for Low mass Higgs Portal Scalars at the MicroBooNE Detector in the NuMI Beam

The MicroBooNE experiment exploits Liquid Argon Time Projection Chamber (LArTPC) technology to detect neutrinos from two beams at Fermilab, Chicago: on-axis Booster Neutrino Beam (BNB) and the off-axis Neutrinos at the Main Injector (NuMI) beam. While the aim of the experiment is to study the low-energy excess of electron neutrino events observed by the MiniBooNE experiment, to search for eV-scale sterile neutrinos and to characterise neutrino interactions on argon, it could also be exploited to probe Beyond Standard Model (BSM) Physics. This thesis presents a BSM search for low-mass Higgs Portal Scalars at MicroBooNE in the NuMI beam using data collected during the Run 1 and Run 3 data-taking periods with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target (POT). The Higgs Portal Model is an extension to the Standard Model in which a dark-sector scalar, $S$, mixes with the Higgs boson with mixing angle $\theta$ and acquires a coupling to the Standard Model fermions via the Higgs Yukawa coupling. We search for low-mass Higgs Portal scalars, in the mass range $100-200$ MeV, at MicroBooNE via the production channel $K \rightarrow \pi + S$, where scalars are produced from kaons decaying at rest in the NuMI target and beam dump, as well as kaons decaying in flight in the decay pipe of the NuMI beam. In the MicroBooNE detector, we search for the decay channel $S \rightarrow e^+e^-$, which is the only decay channel available to the scalars in the mass range of our search. The results are expressed as limits, at the 95\% confidence level, on the scalar-Higgs mixing angle $\theta$ for scalars in the mass range $100-200$ MeV.Date of Award1 Aug 2023Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

Developing a data-driven method to constrain the antiproton background in the Mu2e experiment

The Mu2e experiment will search for CLFV neutrinoless coherent muon to electron conversion in the field of an Al nucleus. The expected signal is a 104.97 MeV/c monochromatic $e^-$ (CE). CE-like $e^-$’s could also come from $\bar{p}$’s annihilating in the Stopping Target (ST). The background induced by $\bar{p}$’s is expected to be low but has a large systematic uncertainty. It cannot be suppressed by the time window cut used to reduce the prompt background. However, $p\bar{p}$ annihilation in the ST is the only source of events in the Mu2e detector with multiple tracks coming from the ST, simultaneous in time, each with a momentum in the signal window region. We exploited this unique feature and developed algorithms to identify and reconstruct multi-track events. This paper discusses the status and prospects of this data-driven method to constrain the $\bar{p}$ background at Mu2e.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors

We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, [nσ] h , follows a linear relationship with the proton fluence, F p , with a slope of (5.4 ± 0.4) x 10 -11 cm/p + . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗

Experimental evidence of runaway electron tail generation via localized helical structure in pellet-triggered tokamak disruptions

A novel detector, using stacked BGO crystals, is developed for runaway electron (REs) studies in the DIII-D tokamak. It is able to resolve fast dynamics of high-energy tail formation of REs with an ultra-high time resolution of ~1 μs. As a cost, the detector estimates the `effective' energy of a given shape of γ-ray spectra and sacrifices the energy resolution. In aid of the new measurement capability, a rapid, inhomogeneous growth of RE tail is observed in detail during a major disruption triggered by an argon pellet. It is found that both the population and energy of a well-confined RE tail significantly oscillate at the early period of the growth. The oscillation phase is locked to a slow rotating magnetohydrodynamic instability, which is briefly destabilized for only ~1 ms at the early period of the current quench. The oscillation ceases promptly, when the mode disappears. As a result, the data suggests that the high-energy RE tail is well-confined and accelerated via a localized helical structure in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗