Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Experimental study of steam-driven ejector heat pump

Ejector-driven systems have been shown to be promising for heating applications. Most of the research works have been devoted to cooling purposes, while little attention has been focused on heating applications. An experimental steam ejector heat pump system (EHP) was designed and constructed to assess its applicability to water heating applications. The effect of the primary nozzle exit position (NXP) on the performance of the steam ejector system was investigated for primary nozzle throat diameter of 1.5 mm and 2.0 mm. The ejector system was run for high-temperature evaporator (HTE) temperatures of 120, 130, and 140 °C and low-temperature evaporator (LTE) temperatures of 10, 15, and 20 °C. The target of this investigation was to attain the highest condensing temperature to be able to use the proposed system for water heating purposes. The ejector heat pump coefficient of performance (EHP COP) was used to determine the system efficiency. Larger LTE temperatures were found to result in higher EHP COPs and condensing temperatures. A maximum EHP COP of 2.02 was attained for a HTE and LTE temperatures of 120 °C and 20 °C, respectively; however only resulted in a condensing temperature of 22.88 °C. Higher HTE temperatures were found to result in higher condensing temperatures but at the cost of EHP COP.

Spitzenberger, Jeremy↗

The importance of the transmission flux in evaluating the preheat effect in x-ray driven ablation

In x-ray driven ablation, the preheat effect is caused by the high energy x-rays that pass through the ablator. Thus, the transmission flux can be used to characterize preheat effect in a certain degree. With the radiation temperature being 200 eV, the transmission flux and preheat temperature of pure polymer (CH) have been studied by using the one-dimensional multi-group radiation hydrodynamic code MULTI-1D. By studying the spectrum of the transmitted x-rays, it is found that the energy of the transmitted x-rays is in the range of 2–5 keV for pure CH ablator. This is of importance for selecting a dopant for CH ablator. We also calculated both the preheat temperature of CH near the surface of thick target (47.66 μm) and the transmission flux of a thinner target (38.66 μm). It is found that the more transmission flux leads to the higher preheat temperature. Preheat effect of graded Si-doped CH targets with different doped concentrations has also been studied. The results are consistent with this phenomenon. By analyzing the relationship between the transmission flux and the preheat temperature, we have presented a novel method to evaluate preheat effect in x-ray driven ablation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling High-Temperature and High-Voltage Lithium-Ion Battery Performance through a Novel Cathode Surface-Targeted Additive

We report lithium-ion batteries (LIBs) are being used in locations and applications never imagined when they were first conceived. To enable this broad range of applications, it has become necessary for LIBs to be stable to an ever broader range of conditions, including temperature and energy. Unfortunately, while negative electrodes have received a great deal of focus in electrolyte development, stabilization of positive electrodes remains an elusive target. Here, we report a novel additive that shows the ability to protect positive electrodes against elevated temperatures and voltages. This additive can be used in small quantities, and its targeted behavior allows it to remain functional in complex electrolyte packages. This can prove an effective approach to targeting specific aspects of cell performance.

25 ENERGY STORAGE↗

Combustion for future supersonic transport propulsion

Even with it's marginal performance, Concorde has demonstrated that supersonic civil aircraft are a practical proposition. A second generation machine will need sufficiently good performance for a robust operating system that can provide reliable, frequent service with competitive economics. Additionally, the propulsion system must be acceptable environmentally. That is it must create acceptable noise levels around airports and have acceptable emissions throughout its mission including cruise. Whatever devices may be used to improve the acceptability at subsonic flight conditions, the high operating temperatures at cruise can create difficult targets for the operation of the combustion system both mechanically and in the combustion process itself. While the driving force is ever better fuel consumption and weight to achieve economic viability, a future supersonic transport engine will have cycle temperatures limited only by the mechanical integrity of the major components. The environment of the major components in modern gas turbine engines is dominated by the air delivered by the compressor system. Consequently the maximum compression temperature is governed by materials available for the turbine and compressor discs. The continued improvement of the disc material leads to combustion inlet temperatures beyond today's experience and sets difficult targets for combustion system emissions. This is worsened by the requirement being at cruise and therefore maintained for the major part of the mission. Problems such as creep and oxidation of metallic parts are also considered.

B. W. Lowrie↗

Thermal infrared images to quantify thermal ablation effects of acid and base on target tissues

Hyperthermia (42-46°C), treatment of tumor tissue through elevated temperature, offers several advantages including high cost-effectiveness, highly targeted ablation and fewer side effects and hence higher safety level over traditional therapies such as chemotherapy and radiotherapy. Recently, hyperthermia using heat release through exothermic acid-base neutralization comes into view owing to its relatively safe products of salt and water and highly confined ablation. However, lack of quantitative understanding of the spatial and temporal temperature profiles that are produced by simultaneous diffusion of liquid chemical and its chemical reaction within tumor tissue impedes the application of this method. This article is dedicated to quantify thermal ablation effects of acid and base both individually and as in neutralization via infrared captured thermal images. A theoretical model is used to approximate specific heat absorption rate (SAR) based on experimental measurements that contrast two types of tissue, normal pork and pig liver. According to the computation, both pork and liver tissue has a higher ability in absorbing hydrochloric acid (HCl) than sodium hydroxide, hence suggesting that a reduced dosage for HCl is appropriate in a surgery. The heating effect depends heavily on the properties of tissue types and amount of chemical reagents administered. Given thermal parameters such as SAR for different tissues, a computational model can be made in predicting temperature transitions which will be helpful in planning and optimizing surgical hyperthermia procedures.

60 APPLIED LIFE SCIENCES↗

Dynamics and Power Balance of Near Unity Target Gain Inertial Confinement Fusion Implosions

The change in the power balance, temporal dynamics, emission weighted size, temperature, mass, and areal density of inertially confined fusion plasmas have been quantified for experiments that reach target gains up to 0.72. It is observed that as the target gain rises, increased rates of self-heating initially overcome expansion power losses. This leads to reacting plasmas that reach peak fusion production at later times with increased size, temperature, mass and with lower emission weighted areal densities. Analytic models are consistent with the observations and inferences for how these quantities evolve as the rate of fusion self-heating, fusion yield, and target gain increase. At peak fusion production, it is found that as temperatures and target gains rise, the expansion power loss increases to a near constant ratio of the fusion self-heating power. Finally, this is consistent with models that indicate that the expansion losses dominate the dynamics in this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of hydrogen cluster velocities and comparison with numerical calculations

The use of powerful hydrogen cluster jet targets in storage ring experiments led to the need of precise data on the mean cluster velocity as function of the stagnation temperature and pressure for the determination of the volume density of the target beams. For this purpose a large data set of hydrogen cluster velocity distributions and mean velocities was measured at a high density hydrogen cluster jet target using a trumpet shaped nozzle. The measurements have been performed at pressures above and below the critical pressure and for a broad range of temperatures relevant for target operation, e.g., at storage ring experiments. The used experimental method is described which allows for the velocity measurement of single clusters using a time-of-flight technique. Since this method is rather time-consuming and these measurements are typically interfering negatively with storage ring experiments, a method for a precise calculation of these mean velocities was needed. For this, the determined mean cluster velocities are compared with model calculations based on an isentropic one-dimensional van der Waals gas. Based on the obtained data and the presented numerical calculations, a new method has been developed which allows to predict the mean cluster velocities with an accuracy of about 5%. For this two cut-off parameters defining positions inside the nozzle are introduced, which can be determined for a given nozzle by only two velocity measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Studies of the Laser Inertial Fusion Energy (LIFE) Target during Injection into the Fusion Chamber

The tests of the external heat transfer coefficient suggests that the values used in the numerical analysis for the temperature distribution within the fusion fuel target following flight into the target chamber are probably valid. The tests of the heat transfer phenomena occurring within the target due the rapid heating of the LEH window for the hot gasses within the fusion chamber show that the heat does indeed convect via the internal helium environment of the target towards the capsule and that the pressure in the front compartment of the target adjacent to the LEH window increases such that t bypass venting of the internal helium into the second chamber adjacent to the capsule is needed to prevent rupture of the membranes. The bypass flow is cooled by the hohlraum during this venting. However, the experiments suggest that our internal heat flow calculations may be low by about a factor of 2. Further studies need to be conducted to investigate the differences between the experiment and the numerical analysis. Future studies could also possibly bring the test conditions closer to those expected in the fusion chamber to better validate the results. A sacrificial layer will probably be required on the LEH window of the target and this can be used to mitigate any unexpected target heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration Testing for Ground Servicing of the Commercial Crew Vehicle Emergency Breathing Air Assembly

The new Commercial crew vehicle (CCV) Breathing Air Assembly (CEBAA) is a Composite Overwrapped Pressure Vessel (COPV) filled with high-pressure air, which is designed to provide portable emergency breathing air for up to five crew in the event of an ammonia leak aboard the International Space Station (ISS). Industrially, several common methods of delivering breathing air exist; however, ground processing constraints and flight requirements necessitate the more unusual approach of servicing a COPV with high purity gaseous nitrogen and oxygen serially to achieve a specific mixture of breathing air at approximately 4000 PSIA. A dwell period allows the gases to mix before sampling for composition verification. The novelty of this approach led to concerns about acceptable gas mixing and the ability to deliver accurate gas compositions. Tests examining mixing rate over a series of post-servicing dwell periods were conducted to determine the optimal time for achieving a homogeneous mixture. Further testing was conducted to examine process accuracy using temperature-pressure load criteria to target a specific concentration of oxygen and nitrogen. Test results show that while some stratification of nitrogen and oxygen was observed, a seven-day dwell is adequate time to achieve an acceptable level of mixing, and that existing ground support equipment can accurately service CEBAA COPVs to the required temperature, pressure and composition for flight.

Active Thermal↗

Demonstration Testing for Ground Servicing of the Commercial Crew Vehicle Emergency Breathing Air Assembly

The new Commercial crew vehicle (CCV) Emergency Breathing Air Assembly (CEBAA) is a Composite Overwrapped Pressure Vessel (COPV) filled with high-pressure air, which is designed to provide portable emergency breathing air for up to five crew in the event of an ammonia leak aboard the International Space Station (ISS). Industrially, several common methods of delivering breathing air exist; however, ground processing constraints and flight requirements necessitate the more unusual approach of servicing a COPV with high purity gaseous nitrogen and oxygen serially to achieve a specific mixture of breathing air at approximately 4000 PSIA. A dwell period allows the gases to mix before sampling for composition verification. The novelty of this approach led to concerns about acceptable gas mixing and the ability to deliver accurate gas compositions. Tests examining mixing rate over a series of post-servicing dwell periods were conducted to determine the optimal time for achieving a homogeneous mixture. Further testing was conducted to examine process accuracy using temperature-pressure load criteria to target a specific concentration of oxygen and nitrogen. Test results show that while some stratification of nitrogen and oxygen was observed, a seven-day dwell is adequate time to achieve an acceptable level of mixing, and that existing ground support equipment can accurately service CEBAA COPVs to the required temperature, pressure and composition for flight.

Active Thermal↗

Isotopic temperature in spallation reactions

The possibility of applying the double-isotope-ratio method for calculating temperature to spallation products formed by high-energy protons is discussed. It is concluded that, at a specific incident-particle energy, spallation is characterized by a single temperature of the formation of products for targets in the mass range 56 {<=} A {<=} 208. No energy dependence of the temperature that was calculated by the double-isotope-ratio method was observed in the energy range 0.3 {<=} E {<=} 300 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Space and Time Resolved Measurements of the Heating of Solids to Ten Million Kelvin by a Petawatt Laser

The heating of plane solid targets by the Vulcan petawatt laser at powers of 0.32-0.73 PW and intensities of up to 4 x 10^20 W cm^-2 has been diagnosed with a temporal resolution of 17 ps and a spatial resolution of 30 um, by measuring optical emission from the opposite side of the target to the laser with a streak camera. Second harmonic emission was filtered out and the target viewed at an angle to eliminate optical transition radiation. Spatial resolution was obtained by imaging the emission onto a bundle of fibre optics, arranged into a one-dimensional array at the camera entrance. The results show that a region 160 um in diameter can be heated to a temperature of ~10^7 K (kT/e ~ keV) in solid targets from 10 to 20 um thick and that this temperature is maintained for at least 20 ps, confirming the utility of PW lasers in the study of high energy density physics. Hybrid code modelling shows that magnetic field generation prevents increased target heating by electron refluxing above a certain target thickness and that the absorption of laser energy into electrons entering the solid target was between 15-30%, and tends to increase with laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Wind-powered Rover for a Low-Cost Venus Mission

Venus, with a surface temperature of 450 C and an atmospheric pressure 90 times higher than that of the Earth, is a difficult target for exploration. However, high-temperature electronics and power systems now being developed make it possible that future missions may be able to operate in the Venus environment. Powering such a rover within the scope of a Discovery class mission will be difficult, but harnessing Venus' surface winds provides a possible way to keep a powered rover small and light. This project scopes out the feasibility of a wind-powered rover for Venus surface missions. Two rover concepts, a land-sailing rover and a wind-turbine-powered rover, were considered. The turbine-powered rover design is selected as being a low-risk and low-cost strategy. Turbine detailed analysis and design shows that the turbine can meet mission requirements across the desired range of wind speeds by utilizing three constant voltage generators at fixed gear ratios.

Benigno, Gina↗

Experimental research of graphite behavior under the air ingress accident condition of High Temperature Gas-cooled Reactor - 18752

As the major component of both cladding and grid spacer materials of High Temperature Gas-cooled Reactor (HTGR), graphite plays an important role on heat removal during the severe accident sequence. However, its heat transfer behavior in high temperature condition may be affected by the oxidation of graphite when the air or steam ingresses in an accident. In this research, an experiment was conducted to analyze the graphite heat transfer behavior in high temperature oxidable environment. An assembly including two graphite rings was used as the test section. It was heated up by a tungsten wire, which is installed inside the inner graphite ring and be joule heated. Temperature was measured by several K-type thermos-couples in certain positions. Argon gas was injected in advance to avoid the unwanted oxidation by the oxygen in the air. Air was injected into the gap between two graphite rings once the temperature of the inner ring reached target point to create the oxidable environment. Based on the results, a rapid increase of inner graphite ring's temperature can be observed after starting injected the air, and a rapid decrease after stopped the injection. It might due to the chemical reaction heat during the graphite surface oxidation. By comparing the steady state before and after air injection, the inner specimen s temperature is a little bit lower after the oxidation, which suggests that its ability of radiation heat transfer might be enhanced a little bit by oxidation. By visualized the test section, coarser surface at the inner graphite ring can be observed after the oxidation. In addition, about 8.9% mass loss of the oxidized graphite can also be found from the posttest examination. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First Evidence of Local E × B Drift in the Divertor Influencing the Structure and Stability of Confined Plasma near the Edge of Fusion Devices

The structure of the edge plasma in a magnetic confinement system has a strong impact on the overall plasma performance. Here we uncover for the first time a magnetic-field-direction dependent density shelf, i.e., local flattening of density radial profile near the magnetic separatrix, in high confinement plasmas with low edge collisionality in the DIII-D tokamak. The density shelf is correlated with a doubly peaked density profile near the divertor target plate, which tends to occur for operation with the ion BX∇B drift direction away from the X-point, as currently employed for DIII-D advanced tokamak scenarios. This double-peaked divertor plasma profile is connected via the EXB drifts, arising from a strong radial electric field induced by the radial electron temperature gradient near the divertor target. The drifts lead to the reversal of the poloidal flow above the divertor target, resulting in the formation of the density shelf. The edge density shelf can be also enhanced at higher heating power, preventing large, periodic bursts of the plasma, i.e. Edge-localized Modes, in the edge region, consistent with ideal magnetohydrodynamics calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermometric- and Acoustic-Based Beam Power Monitor for Ultra-Bright X-Rays

A design for an average beam power monitor for ultra-bright X-ray sources is proposed that makes simultaneous use of calorimetry and radiation acoustics. Radiation incident on a solid target will induce heating and ultrasonic vibrations, both of which may be measured to give a fairly precise value of the beam power. The monitor is intended for measuring ultra-bright Free-Electron Laser (FEL) X-ray beams, for which traditional monitoring technologies such as photo-diodes or scintillators are unsuitable. The monitor consists of a Boron Carbide (B{sub 4}C) target designed to absorb most of the incident beam's energy. Resistance temperature detectors (RTD) and piezoelectric actuators are mounted on the outward faces of the target to measure the temperature changes and ultrasonic vibrations induced by the incident beam. The design was tested using an optical pulsed beam (780 nm, 120 and 360 Hz) from a Ti:sapphire oscillator at several energies between 0.8 and 2.6 mJ. The RTDs measured an increase in temperature of about 10 K over a period of several minutes. The piezoelectric sensors recorded ringing acoustic oscillations at 580 {+-} 40 kHz. Most importantly, the amplitude of the acoustic signals was observed to scale linearly with beam power up to 2 mJ of pulse energy. Above this pulse energy, the vibrational signals became nonlinear. Several causes for this nonlinearity are discussed, including amplifier saturation and piezoelectric saturation. Despite this nonlinearity, these measurements demonstrate the feasibility of such a beam power measurement device. The advantage of two distinct measurements (acoustic and thermometric) provides a useful method of calibration that is unavailable to current LCLS diagnostics tools.

Bentsen, Gregory↗

Using data-science approaches to unravel insights for enhanced transport of lithium ions in single-ion conducting polymer electrolyte

Solid polymer electrolytes have yet to achieve the an ionic conductivity > 1 mS/cm at room temperature for realistic applications. This target implies the need to reduce the effective energy barriers of ion transport in polymer electrolytes to around 20 kJ/mol. In this work, we combine information extracted from existing experimental results with theoretical calculations to provide insights into ion transport in single-ion conductors (SICs) with a focus on lithium ion SICs. Through the analysis of temperature-dependent ionic conductivity data obtained from the literature, we evaluate different methods of extracting energy barriers for lithium transport. The traditional Arrhenius fit to the temperature-dependent ionic conductivity data indicates that the Meyer-Neldel rule holds for SICs. However, the values of the fitting parameters remain unphysical. Our modified approach based on recent work (Macromolecules, 56, 15, 6051(2023)), which incorporates a fixed pre-exponential factor, reveals that the energy barriers exhibit temperature dependence over a wide range of temperatures. Using this approach, we identify a series of anions leading to the energy barriers less than 30 kJ/mol, which include trifluoromethane sulfonimide (TFSI), fluoromethane sulfonimide (FSI), and boron-based organic anions. In our efforts to design the next generation of anions, which can exhibit the energy barriers less than 20 kJ/mol, we focused on boron-containing SICs, and performed density functional theory (DFT) based calculations to connect the chemical structures via the binding energy of cation (lithium)-anion pairs with the experimentally derived effective energy barriers for ion transport. Not only have we identified a correlation between the binding energy and the energy barriers, but we also propose a strategy to design new boron-based anions by using the correlation. This combined approach involving experiments and theoretical calculations is capable of facilitating the identification of promising new anions, which can exhibit ionic conductivity $> 1$ mS/cm near room temperature, thereby expediting the development of novel superionic single-ion conducting polymer electrolytes. The published datasets include all the temperature-dependent ionic conductivity collected from the literature with literature DOIs, DFT calculated binding energies, and python scripts to analyze data, construct statistical models, and generate plots.

36 MATERIALS SCIENCE↗