Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Wavelength dispersive analysis with the synchrotron x ray fluorescence microprobe

A wavelength dispersive spectrometer (WDS) was tested on the synchrotron x ray fluorescence microprobe at Brookhaven National Laboratory. Compared to WDS spectra using an electron microprobe, the synchrotron WDS spectra have much better sensitivity and, due to the absence of bremsstrahlung radiation, lower backgrounds. The WDS spectrometer was successfully used to resolve REE L fluorescence spectra from standard glasses and transition metal K fluorescence spectra from kamacite.

Rivers, M. L.↗

Relativistic induced Compton scattering in synchrotron self-absorbed sources

We present a model of the radio emission from synchrotron self-absorbed sources, including the effects of induced Compton scattering by the relativistic electrons in the source. Order of magnitude estimates show that stimulated scattering becomes the dominant absorption process when (kT(sub B)/m(sub e) c(exp 2))Tau(sub T) greater than or approximately 1.0. Numerical simulations demonstrate that relativistic induced Compton scattering limits the brightness temperature of a self-absorbed synchroton sources to T(sub B) less than or approximately 2 x 10(exp 11) nu(exp -1/p + 3) (sub zero, 9) gamma(exp p + 2/p + 5) (sub min) K, where gamma(sub min) is the low-energy cutoff to the relativistic electron distribution with a power-law index of p. It can also significantly flatten the radio spectrum. The radio spectrum of the core of 3C 279 is well matched by a model in which stimulated scattering is important, and the additional constraint T(sub B) less than 2 x 10(exp 11)K may be important to the interpretation of the broadband spectra in variable extragalactic compact radio sources. Stimulated scattering reduces the amplitude of the radio frequency variability relative to the X-ray variability, an effect which can be detected by multiwavelength variability studies. Data for a sample of resolved compact radio cores indicate that it is inconsistent to neglect induced Compton scattering when inferring the physical parameters of the sources. The necessary generalizations to the standard synchrotron self-Compton theory are p resented.

Sincell, Mark W.↗

The synchrotron continuum of the highly polarized quasar PKS 1546+027

The wavelength dependence of optical linear polarization of the highly polarized quasar (HPQ) PKS 1546+027 is investigated for the first time. Both spectropolarimetry and broad-band filter polarimetry are presented for a period when the object was undergoing a strong ourburst in flux and polarization. The rapid polarization variations observed argues that an optically thin synchrotron-emitting region, similar in polarization properties to BL Lacertae objects and optically violent variable (OVV) quasars, is the major source of polarized flux from this object. The continuum polarization increases dramatically with wavelength and is about twice as high at 8000 A than at 4000 A. Spectropolarimetry reveals that the emission-line flux from PKS 1546+027 dilutes the continuum polarization and is probably unpolarized. There is no evidence for any variation in polarization position angle with wavelength. The polarized flux spectrum is well-represented by a steep power law with a spectral index of -2.2, supporting the view that the polarized flux has a nonthermal origin. The observed polarization properties of PKS 1546+027 are consistent with a model that has been proposed to explain the optical to ultraviolet continua of several OVVs. In this model the optical to near-UV spectral flux distribution is a combination of light from a polarized synchrotron component plus an unpolarized component with spectral properties typical of low-polarization quasars.

Smith, Paul S.↗

Radial diffusion models of energetic electrons and Jupiter's synchrotron radiation. 2: Time variability

We used a radial diffusion code for energetic electrons in Jupiter's magnetosphere to investigate variations in Jupiter's radio emission due to changes in the electron phase space density at L shells between 6 and 50, and due to changes in the radial diffusion parameters. We suggest that the observed variations in Jupiter's radio emission are likely caused by changes in the electron phase space density at some boundary L(sub 1) is greater than 6, if the primary mode of transport of energetic electrons is radial diffusion driven by fluctuating electric and/or magnetic fields induced by upper atmospheric turbulence. We noticed an excellent empirical correlation, both in phase and relative amplitude, between changes in the solar wind ram pressure and Jupiter's synchrotron radiation if the electron phase space density at the boundary L(sub 1) (L(sub 1) is approximately equal to 20-50) varies linearly with the square root of the solar wind ram pressure, f is approximately (N(sub s)nu(exp 2 sub s))(exp 1/2). The calculations were carried out with a diffusion coefficient D(sub LL) = D(sub n)L(exp n) with n = 3. The diffusion coefficient which best fit the observed variations in Jupiter's synchrotron radiation D(sub 3) = 1.3 +/- 0.2 x 10(exp -9)/s is approximately 0.041/yr, which corresponds to a lagtime of approximately 2 years. We further show that the observed short term (days-weeks) variations in Jupiter's radio emission cannot be explained adequately when radial diffusion is taken into account.

De Pater, Imke↗

Searching for the Best Protein Crystals: Synchrotron Based Measurements of Protein Crystal Quality

We are developing X-ray diffraction methods to quantitatively evaluate the quality of protein crystals. The ultimate use for these crystal quality will be to optimize crystal growth and freezing conditions to obtain the best diffraction data. We have combined super fine-phi slicing with highly monochromatic, low divergence synchrotron radiation and the ADSC Quantum 4 CCD detector at the Stanford Synchrotron Radiation laboratory beamline 1.5 to accurately measure crystal mosaicity. Comparisons of microgravity versus earth-grown insulin crystals using these methods will be presented.

Borgstahl, Gloria↗

Changes in Jupiter's 13-cm Synchrotron Radio Emission Following the Impact of Comet Shoemaker-Levy-9

Results of an observing program to monitor the synchrotron radio emission from Jupiter's inner radiation belts before, during and after the impact of Comet SL-9 are reported. The observations were made at 2295 MHz as part of the NASA-JPL Jupiter Patrol, a long-term radio astronomy monitoring program begun in 1971. ne data indicate that the intensity of the synchrotron emission at 13 cm wavelength increased by 27 percent within a few days after the comet impacts; the longitudinal beaming curve was distorted during the week of impacts; the magnetic latitude beaming curves flattened after the week of impacts suggesting an increase in the emission at higher magnetic latitudes; and the decay of the enhanced emission is consistent with an exponential with a time constant of approx. 125 days. The reported changes following the SL-9 impact are unprecedented in the 23-year history of the Jupiter Patrol.

Klein, M. J.↗

Synchrotron X-Ray Reciprocal Space Mapping, Topography and Diffraction Resolution Studies of Macromolecular Crystal Quality

A comprehensive study of microgravity and ground grown chicken egg white lysozyme crystals is presented using synchrotron X-ray reciprocal space mapping, topography techniques and diffraction resolution. Microgravity crystals displayed, on average, reduced intrinsic mosaicities but no differences in terms of stress over their earth grown counterparts. Topographic analysis revealed that in the microgravity case the majority of the crystal was contributing to the peak of the reflection at the appropriate Bragg angle. In the earth case at the diffraction peak only a small volume of the crystal contributed to the intensity. The techniques prove to be highly complementary with the reciprocal space mapping providing a quantitative measure of the crystal mosaicity and stress (or variation in lattice spacing) and topography providing a qualitative overall assessment of the crystal in terms of its X-ray diffraction properties. Structural data collection was also carried out both at the synchrotron and in the laboratory.

Boggon, T. J.↗

Comparison of Synchrotron MicroXANES Determination of Fe(3+)/Sigma Fe with Moessbauer Values for Clean Mineral Separates of Pyroxene from Martian Meteorites

The oxidation state of Fe in Martian meteorites is a parameter of great interest and the ability to determine this value in micrometer scale samples is important. Intense, tunable x-ray sources at large synchrotron storage rings are being exploited to examine the Fe K-absorption edge with energy resolution of approx. 1-1.5eV in spots of 10x15 microns on thin sections of a wide variety of materials including several Martian meteorites. Synchrotron microXANES (SmX) spectroscopy is the technique that provides the most flexible capability for investigating Fe(3+)/Sigma Fe. Variation of Fe(3+)/Sigma Fe is manifested as a function of the energy of the pre-edge to the Fe absorption edge produced by the sample. SmX is at present the only technique that can be used with conventional polished thin sections. Data for a broad spectrum of minerals have been produced and indicate that SmX can be used with a large variety of samples types.

Delaney, J. S.↗

Synchrotron Characterization of Hydrogen and Ferric Iron in Martian Meteorites

The hydrogen budget of the Martian interior is distributed among several phases: melts, hydrous minerals, and nominally anhydrous minerals like olivine, pyroxene, and garnet. All these phases are vulnerable to loss of hydrogen during shock, excavation and transport via the mechanism of dehydrogenation, in which the charge on the H protons is left behind as polarons on Fe atoms. Thus, both H and F(3x) must be analyzed in order to reconstruct hydrogen and oxygen fugacities on Mars. To date, SIMS data have elucidated D/H and H contents of hydrous phases in SNC meteorites, but anhydrous martian minerals have not been systematically examined for trace hydrogen. Ferric iron has been quantified using XANES in many marital phases, but integrated studies of both Fe(3x) and H on the same spots are really needed to address the H budget. Here, we measure and profile H and Fe(3x) abundances in and across individual grains of glass and silicates in Martian meteorites. We use the new technology of synchrotron microFI'lR spectroscopy to measure the hydrogen contents of hydrous and nominally anhydrous minerals in martian meteorites on 30-100 microns thick, doubly polished thin sections on spots down to 3 x 3 microns. Synchrotron microXANES was used to analyze Fe(3x) on the same scale, and complementary SIMS D/H data will be collected where possible, though at a slightly larger scale. Development of this combination of techniques is critical because future sample return missions will generate only microscopic samples for study. Results have been used to quantitatively assess the distribution of hydrogen and ferric iron among phases in the martian interior, which will better constrain the geodynamic processes of the interior, as well as the overall hydrogen and water budgets on Mars.

Dyar, Melinda D.↗

A Hadronic Synchrotron Mirror Model for the "Orphan" Tev Flare in 1ES 1959+650

Very high energy gamma-ray flares of TeV blazars are generally accompanied by simultaneous flaring activity in X-rays. The recent observations by the Whipple collaboration of an "orphan" TeV flare of 1 ES 1959+650 (without a simultaneous X-ray flare) are very difficult to reconcile with the standard leptonic synchrotron self-Compton model, which is routinely very successfully employed to explain the spectral energy distribution and spectral variability of TeV blazars. In this paper an alternative scenario is suggested in which the orphan TeV flare may originate from relativistic protons, interacting with an external photon field supplied by electron synchrotron radiation reflected off a dilute reflector. While the external photons will be virtually "invisible" to the comoving ultrarelativistic electrons in the jet because of Klein-Nishina effects, their Doppler-boosted energy is high enough to excite a Delta-resonance from relativistic protons with Lorentz factors of gamma(sub p) approx. 10(exp 3)-10(exp 4). This model is capable of explaining the orphan TeV flare of 1ES 1959+650 with plausible parameters, thus constraining the number and characteristic energy of relativistic protons in the jet of this blazar.

Bottcher, Markus↗

Observations of Jupiter's Synchrotron Radiation at 18 cm during the Comet SL-9 Impacts

The results of observations of Jupiter's synchrotron radiation during the period surrounding the impacts of comet SL-9 are reported. The observations were made at the Naval Research Laboratory's Maryland Point Observatory 85 foot radio antenna operating at 1665 MHz (18 cm). The data indicate that an increase in the intensity of the synchrotron emission of 23% took place over the full duration of the impact period. The increase was accompanied by two characteristic changes in the beaming curve: a flattening and the creation of brightness temperature variations on hourly timescales. We interpret the latter as longitudinal variations in the beaming curve which suggests a localized mechanism resulting in a redistribution of the radiating electronis in the Jovian radiation belts.

Jupiter Comet SL-9↗

Synchrotron Radiation from Outer Space and the Chandra X-Ray Observatory

The universe provides numerous extremely interesting astrophysical sources of synchrotron X radiation. The Chandra X-ray Observatory and other X-ray missions provide powerful probes of these and other cosmic X-ray sources. Chandra is the X-ray component of NASA's Great Observatory Program which also includes the Hubble Space telescope, the Spitzer Infrared Telescope Facility, and the now defunct Compton Gamma-Ray Observatory. The Chandra X-Ray Observatory provides the best angular resolution (sub-arcsecond) of any previous, current, or planned (for the foreseeable near future) space-based X-ray instrumentation. We present here a brief overview of the technical capability of this X-Ray observatory and some of the remarkable discoveries involving cosmic synchrotron sources.

Weisskopf, M. C.↗

Synchrotron Spectral Curvature from 22 MHZ to 23 GHZ

We combine surveys of the radio sky at frequencies 22 MHz to 1.4 GHz with data from the ARCADE-2 instrument at frequencies 3 GHz to 10 GHz to characterize the frequency spectrum of diffuse synchrotron emission in the Galaxy. The radio spectrum steepens with frequency from 22 MHz to 10 GHz. The projected spectral index at 23 GHz derived from the low-frequency data agrees well with independent measurements using only data at frequencies 23 GHz and above. Comparing the spectral index at 23 GHz to the value from previously published analyses allows extension of the model to higher frequencies. The combined data are consistent with a power-law index beta = -2.64 +/-= 0.03 at 0.31 GHz, steepening by an amount of Delta-beta = 0.07 every octave in frequency. Comparison of the radio data to models including the cosmic-ray energy spectrum suggests that any break in the synchrotron spectrum must occur at frequencies above 23 GHz.

Kogut, Alan J.↗

Real Time In Situ Observations of Equiaxed Dendrite Coherency in Al-Cu Alloys Using High-Brilliance, 3rd Generation Synchrotron Sources

In the last decade synchrotron X-ray sources have fast become the tool of choice for performing in-situ high resolution imaging during alloy solidification. This paper presents the results of an experimental campaign carried out at the European Synchrotron Radiation Facility, using a Bridgman furnace, to monitor phenomena during solidification of Al-Cu alloys - specifically the onset of equiaxed dendrite coherency. Conventional experimental methods for determining coherency involve measuring the change in viscosity or measuring the change in thermal conductivity across the solidifying melt Conflicts arise when comparing the results of these experimental techniques to find a relationship between cooling rate and coherency fraction. It has been shown that the ratio of average velocity to the average grain diameter has an inversely proportional relationship to coherency fraction. In-situ observation therefore makes it possible to measure these values directly from acquired images sequences and make comparisons with published results.

Murphy, Andrew G.↗

Effect of a Synchrotron X-ray Microtomography Imaging Experiment on the Amino Acid Content of a CM Chondrite

X-ray microcomputed tomography and synchrotron X-ray microcomputed tomography (μCT) are becoming popular tools for the reconnaissance imaging of chondrites. However, there are occasional concerns that the use of μCT may be detrimental to organic components of a chondrite. Soluble organic compounds represent ~2–10% of the total solvent extractable carbon in CI and CM carbonaceous chondrites and amino acids are among the most abundant compounds in the soluble organic fraction. We irradiated two samples of the Murchison CM2 carbonaceous chondrite under conditions slightly harsher (increased beam exposure time) than those typically used for x-ray μCT imaging experiments to determine if detectable changes in the amino acid abundance and distribution relative to a nonexposed control sample occurred. After subjecting two meteorite portions to ionizing radiation dosages of 1.1 kiloGray (kGy) and 1.2 kGy with 48.6 and 46.6 keV monochromatic X-rays, respectively, we analyzed the amino acid content of each sample. Within analytical errors, we found no differences in the amino acid abundances or enantiomeric ratios when comparing the control samples (nonexposed Murchison) and the irradiated samples. We show with calculations that any sample heating due to x-ray exposure is negligible. We conclude that a monochromatic synchrotron X-ray μCT experiment at beamline 13-BM-D of the Advanced Photon Source, which imparts ~1 kGy doses, has no detectable effect on the amino acid content of a carbonaceous chondrite. These results are important for the initial reconnaissance of returned samples from the OSIRIS-REx and Hayabusa 2 asteroid sample return missions.

Jon M. Friedrich↗

Optical Synchrotron Radiation Beam Imaging with a Digital Mask

We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

43 PARTICLE ACCELERATORS↗

Optical synchrotron radiation beam imaging with a digital mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

43 PARTICLE ACCELERATORS↗

In Situ Synchrotron Tensile Investigations on 14YWT, MA957 and 9-Cr ODS Alloys

Nanostructured ferritic alloys (NFAs) provide exceptional radiation tolerance and high-temperature mechanical properties when compared to traditional ferritic and ferritic/martensitic (F/M) steels. Their remarkable properties result from ultrahigh density and ultrafine size of Y-Ti-O nanoclusters within the ferritic matrix. In this work, we applied a high-energy synchrotron radiation X-ray to study the deformation process of two NFAs including 14YWT and MA957, and a 9-Cr ODS steel. Only the relatively large nanoparticles in the 9-Cr ODS were observed in the synchrotron X-ray diffraction. The nanoclusters in both 14 YWT and MA957 were invisible in the measurement due to their non-stoichiometric nature. Due to the different sizes of nanoparticles and nanoclusters in the materials, the Orowan looping was considered to be the major strengthening mechanism in the 9-Cr ODS, while the dispersed-barrier-hardening is dominant strengthening mechanism in both 14YWT and MA957, respectively. This analysis was inferred from the different build-up rates of dislocation density when plastic deformation was initiated. Finally, the dislocation densities interpreted from the X-ray measurements were successfully modeled using the Bergstr m s dislocation models.

Lin, Jun-Li↗