Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Ion Source Development for Ultratrace Detection of Uranium and Thorium

A hot-cavity surface ionization source and a hot-cavity laser ion source are evaluated in terms of ionization efficiencies for generating ion beams of U and Th. The work is motivated by the need for more efficient ion sources for detecting ultratrace U and Th impurities in a copper matrix by mass spectrometry techniques such as accelerator mass spectrometry (AMS). The performances of the ion sources are characterized using uranyl nitrate and thorium nitrate sample materials and sample sizes of 20 - 40 g of U or Th. For the surface source, the dominant ion beams observed are UO+ or ThO+ and ionization efficiencies of 2-4% have been obtained with W and Re cavities. Three-step resonant photoionization of U atoms is studied and an ionization efficiency of 8.7% has been obtained with the laser ion source. The positive ion sources promise more than an order of magnitude more efficient than conventional Cs-sputter negative ion sources used for AMS. In addition, the laser ion source is highly selective and effective in suppressing interfering and ions. Work is in progress to improve the efficiencies of both positive ion sources.

Liu, Yuan↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

INDUSTRY ENGAGEMENT TO ESTABLISH A ROBUST SECURITY APPROACH TO MOBILE RADIOACTIVE SOURCES

The mobile radiological sources used in the well-logging and radiography industries are of sufficient curie quantities to be categorized as desirable material for malicious actors. Beyond the security risk posed by these sources, there is also an understanding of the potential damage, both reputational and monetary, that a lost source would have on the licensee and the industry overall. Identifying and communicating the risk these sources pose with impacted stakeholders is a critical first step in developing a security approach. Common day-to-day operations within both industries drive the unique security challenge of mobile sources. From storage facilities, transportation vehicles, temporary storage locations, and use in the field, each phase creates challenges regarding source control and accountability. All aspects of the operational use of these sources needs to be fully understood in order to address security equipment enhancements, policies, procedures, and training. This paper will leverage more than ten years of experience that ORS has gained working closely with industry partners and mobile radiological source users across the well-logging and radiography industries. It will identify the risk posed by mobile radiological sources, clearly define the operational phases of each industry, identify security best practices of mobile sources, and discuss what long-term, sustainable security looks like within these industries. In addition, it will explore areas of a robust security approach that are not commonly given priority in these industries, such as alarm adjudication and response.

Office of Radiological Security↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

A Test Stand for Ion Sources of Ultimate Reliability

The rationale behind the ITUR project is to perform a comparison between different kinds of H{sup -} ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France)

43 PARTICLE ACCELERATORS↗

Alternative modeling methods for plasma-based Rf ion sources

Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models for the SNS source and present simulation results demonstrating plasma evolution over many Rf periods for different plasma temperatures. We perform the calculations in parallel, on unstructured meshes, using finite-volume solvers in order to obtain results in reasonable time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 31 GHz SURVEY OF LOW-FREQUENCY SELECTED RADIO SOURCES

The 100 m Robert C. Byrd Green Bank Telescope and the 40 m Owens Valley Radio Observatory telescope have been used to conduct a 31 GHz survey of 3165 known extragalactic radio sources over 143 deg{sup 2} of the sky. Target sources were selected from the NRAO VLA Sky Survey in fields observed by the Cosmic Background Imager (CBI); most are extragalactic active galactic nuclei (AGNs) with 1.4 GHz flux densities of 3-10 mJy. The resulting 31 GHz catalogs are presented in full online. Using a maximum-likelihood analysis to obtain an unbiased estimate of the distribution of the 1.4-31 GHz spectral indices of these sources, we find a mean 31-1.4 GHz flux ratio of 0.110 +- 0.003 corresponding to a spectral index of alpha = -0.71 +- 0.01 (S {sub n}u propor to nu{sup a}lpha); 9.0% +- 0.8% of sources have alpha > - 0.5 and 1.2% +- 0.2% have alpha > 0. By combining this spectral-index distribution with 1.4 GHz source counts, we predict 31 GHz source counts in the range 1 mJy < S {sub 31} < 4 mJy, N(>S {sub 31}) = (16.7 +- 1.7) deg{sup -2}(S {sub 31}/1 mJy){sup -0.80+}-{sup 0.07}. We also assess the contribution of mJy-level (S {sub 1.4GHz} < 3.4 mJy) radio sources to the 31 GHz cosmic microwave background power spectrum, finding a mean power of l(l + 1)C {sup src} {sub l}/(2pi) = 44 +- 14 muK{sup 2} and a 95% upper limit of 80 muK{sup 2} at l = 2500. Including an estimated contribution of 12 muK{sup 2} from the population of sources responsible for the turn-up in counts below S {sub 1.4GHz} = 1 mJy, this amounts to 21% +- 7% of what is needed to explain the CBI high-l excess signal, 275 +- 63 muK{sup 2}. These results are consistent with other measurements of the 31 GHz point-source foreground.

79 ASTRONOMY AND ASTROPHYSICS↗

METHODS FOR ESTIMATING FLUXES AND ABSORPTIONS OF FAINT X-RAY SOURCES

X-ray sources with very few counts can be identified with low-noise X-ray detectors such as the Advanced CCD Imaging Spectrometer on board the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broadband X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high signal-to-noise spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of approx2000 faint sources in the Chandra observation of the rich young stellar cluster in the M 17 H II region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of nonlinear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-NEWTON DETECTION OF A TRANSIENT X-RAY SOURCE IN THE VICINITY OF V838 MONOCEROTIS

We report the XMM-Newton/EPIC detection in 2008 March of a luminous (L{sub X} {approx} 10{sup 32-33} erg s{sup -1}), variable X-ray source in the vicinity (within {approx}6'') of the enigmatic star V838 Mon, which underwent a spectacular outburst in early 2002. Spectral modeling of the XMM-Newton X-ray source indicates the presence of two plasma components with characteristic temperatures of T{sub X} {approx} 2 x 10{sup 6} K and {approx}1.5 x 10{sup 7} K, attenuated by an absorbing column (N{sub H} {approx} 4 x 10{sup 21} cm{sup -2}) that is consistent with the visual extinction measured toward V838 Mon (A{sub V} {approx} 2). No such luminous source was detected in the immediate vicinity of V838 Mon in Chandra/ACIS-S observations obtained about one year after outburst or, most recently, in 2010 January. The two XMM -Newton source spectral components appear to be marginally spatially resolved, with the spatial centroid of the hard component lying closer to (within {approx}2'' of) the position of V838 Mon than the broadband source or the soft source component; however, if there are two sources at or near V838 Mon, the Chandra nondetections would imply that both of them are variable. An alternative is that there is a single variable source, and that the apparent spatial separation may actually be due to photon-counting statistics or is perhaps instrumental in origin. We consider constraints placed by the X-ray detection and nondetections on a stellar merger model for the 2002 V838 Mon outburst, in which the spun-up merger product drives a powerful magnetic dynamo. Alternatively, the transient behavior of the X-ray source could indicate that the X-rays arose as a consequence of an interaction between V838 Mon's ejecta and its early-type (B3 V) companion.

79 ASTRONOMY AND ASTROPHYSICS↗

Extragalactic millimeter-wave point-source catalog, number counts and statistics from 771 deg{sup 2} of the SPT-SZ survey

We present a point-source catalog from 771 deg{sup 2} of the South Pole Telescope Sunyaev-Zel'dovich survey at 95, 150, and 220 GHz. We detect 1545 sources above 4.5σ significance in at least one band. Based on their relative brightness between survey bands, we classify the sources into two populations, one dominated by synchrotron emission from active galactic nuclei, and one dominated by thermal emission from dust-enshrouded star-forming galaxies. We find 1238 synchrotron and 307 dusty sources. We cross-match all sources against external catalogs and find 189 unidentified synchrotron sources and 189 unidentified dusty sources. The dusty sources without counterparts are good candidates for high-redshift, strongly lensed submillimeter galaxies. We derive number counts for each population from 1 Jy down to roughly 11, 4, and 11 mJy at 95, 150, and 220 GHz. We compare these counts with galaxy population models and find that none of the models we consider for either population provide a good fit to the measured counts in all three bands. The disparities imply that these measurements will be an important input to the next generation of millimeter-wave extragalactic source population models.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTIBAND DIAGNOSTICS OF UNIDENTIFIED 1FGL SOURCES WITH SUZAKU AND SWIFT X-RAY OBSERVATIONS

We have analyzed all the archival X-ray data of 134 unidentified (unID) gamma-ray sources listed in the first Fermi/LAT (1FGL) catalog and subsequently followed up by the Swift/XRT. We constructed the spectral energy distributions (SEDs) from radio to gamma-rays for each X-ray source detected, and tried to pick up unique objects that display anomalous spectral signatures. In these analyses, we target all the 1FGL unID sources, using updated data from the second Fermi/LAT (2FGL) catalog on the Large Area Telescope (LAT) position and spectra. We found several potentially interesting objects, particularly three sources, 1FGL J0022.2–1850, 1FGL J0038.0+1236, and 1FGL J0157.0–5259, which were then more deeply observed with Suzaku as a part of an AO-7 program in 2012. We successfully detected an X-ray counterpart for each source whose X-ray spectra were well fitted by a single power-law function. The positional coincidence with a bright radio counterpart (currently identified as an active galactic nucleus, AGN) in the 2FGL error circles suggests these sources are definitely the X-ray emission from the same AGN, but their SEDs show a wide variety of behavior. In particular, the SED of 1FGL J0038.0+1236 is not easily explained by conventional emission models of blazars. The source 1FGL J0022.2–1850 may be in a transition state between a low-frequency peaked and a high-frequency peaked BL Lac object, and 1FGL J0157.0–5259 could be a rare kind of extreme blazar. We discuss the possible nature of these three sources observed with Suzaku, together with the X-ray identification results and SEDs of all 134 sources observed with the Swift/XRT.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene

We discuss using a series of detector measurements taken at different locations to localize a source of radiation as a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of the Hard X-Ray Source Dominating the E > 25 keV Emission of the Nearby Galaxy M31

We report the identification of a bright hard X-ray source dominating the M31 bulge above 25 keV from a simultaneous NuSTAR–Swift observation. We find that this source is the counterpart to Swift J0042.6+4112, which was previously detected in the Swift BAT All-sky Hard X-ray Survey. This Swift BAT source had been suggested to be the combined emission from a number of point sources; our new observations have identified a single X-ray source from 0.5 to 50 keV as the counterpart for the first time. In the 0.5–10 keV band, the source had been classified as an X-ray Binary candidate in various Chandra and XMM-Newton studies; however, since it was not clearly associated with Swift J0042.6+4112, the previous E < 10 keV observations did not generate much attention. This source has a spectrum with a soft X-ray excess (kT ∼ 0.2 keV) plus a hard spectrum with a power law of Γ∼1 and a cutoff around 15–20 keV, typical of the spectral characteristics of accreting pulsars. Unfortunately, any potential pulsation was undetected in the NuSTAR data, possibly due to insufficient photon statistics. The existing deep HST images exclude high-mass (>3 M{sub ⊙}) donors at the location of this source. The best interpretation for the nature of this source is an X-ray pulsar with an intermediate-mass (<3 M{sub ⊙}) companion or a symbiotic X-ray binary. We discuss other possibilities in more detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Nb3Sn superconducting magnets for electron cyclotron resonance ion sources

Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb{sub 3}Sn superconducting technology for several years. At the moment, Nb{sub 3}Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb{sub 3}Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb{sub 3}Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb{sub 3}Sn- , particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water-pressurized bladders, and we analyze the expected coil stresses with a two-dimensional finite element mechanical model.

43 PARTICLE ACCELERATORS↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

Designing, selecting and installing a residential ground-source heat pump system

It's a compelling proposition: Use the near-constant-temperature heat underground to heat and cool your home and heat domestic water, slashing your energy bills. Yet despite studies demonstrating significant energy savings from ground-source heat pump (GSHP) systems, their adoption has been hindered by high upfront costs. Fewer than 1% of US homes use a GSHP system. However, compared to a minimum-code-compliant conventional space-conditioning system, when properly designed and installed, a GSHP retrofit at current market prices offers simple payback of 4.3 years on national average, considering existing federal tax credits. Most people understand how air-source heat pumps work: they move heat from indoor air to outdoor air when cooling and from outdoor air to indoor air when heating. The ground-source heat pump operates on the same principle, except that it moves heat to or from the ground source instead of outdoor air. The ground source is usually a vertical or horiontal ground heat exchanger. Because the ground usually has a more favorable temperature than ambient air for the heating and cooling operation of the vapor-compression refrigeration cycle, GSHP sysems can operate with much higher energy efficiencies than air-source heat pump systems when properly designed and installed. A GSHP system used in a residual building typically provides space conditioning and hot water and comprises three major components: a water-source heat pump unit designed to operate at a wider range of entering fluid temperatures (typically from 30 F to 110 F, or 1 C to 43 C) than a conventional water-source heat pump unit; a ground heat exchanger (GHX); and distribution systems to deliver hot water to the storage tank and heating or cooling to the conditioned rooms. In most residual GSHP systems, the circulation pumps and associated valves are integrated with the heat pump to circulate the heat-carrier fluid (water or aqueous antifreeze solution) through the heat pump and the GHX. A recent assessment indicates that if 20% of US homes replaced their existing space-conditioning and water-heating systems with properly designed, installed and operated state-of-the-art GSHP systems, it would yield significant benefits each year. These include 0.8 quad British thermal units (Btu) of primary energy savings, 54.3 million metric tons of CO{sub 2} emission reductions, $10.4 billion in energy cost savings and 43.2 gigawatts of reduction in summer peak electrical demand.

15 GEOTHERMAL ENERGY↗

A dynamic volumetric heat source model for laser additive manufacturing

Melt pool scale models of laser powder bed fusion (LPBF) offer insights into the process-structure-property relationships in additive manufacturing (AM). These models often neglect physical phenomena such as vapor cavity formation and fluid mechanics to reduce computational demands. Instead, volumetric heat source models are used to represent the effects that these phenomena have on the predicted melt pool dimensions. Generally, the dimensions and effective absorption of the volumetric heat source are calibrated to reproduce melt pool dimensions observed in metallographic cross sections taken from single-track experiments on bare plate. However, the transient nature of LPBF often deviates the melt pool dimensions from the assumed steady-state conditions of single-track experiments, motivating the need for a volumetric heat source model that more generally considers the dynamic relationship between melt pool shape and laser-material interactions. Here, we introduce a two-parameter volumetric heat source model that integrates several existing models into a generalized mathematical expression, providing independent control over the radial heat distribution via the parameter k and the volumetric shape of the heat source via the parameter m. This parameterization enables the calibration of melt pool shape predictions through simultaneous adjustment of these parameters, while keeping the radial heat source dimensions consistent with the experimental spot size (D4σ) and constraining the heat source depth and absorption to physically derived expressions for cavities. Consequently, the proposed volumetric heat source model adapts to changes in the local melt pool conditions due to scanning strategy and part geometry by dynamically adjusting the heat source depth and absorption. We demonstrate the capabilities of the proposed model through comparisons with a collection of experiments from the Additive Manufacturing Benchmark (AMBench).

36 MATERIALS SCIENCE↗