Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sheaths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Comparison between Alcator C-Mod ICRF experiments and 3D full wave simulations

Reliable modeling of ion cyclotron range of frequencies (ICRF) antenna performance is essential for interpreting present experiments and guiding the design of future reactors. In this work, a 3D model of the Alcator C-Mod field-aligned antenna is implemented in the Petra-M finite-element framework [S. Shiraiwa et al 2023 Nucl. Fusion 63 026024] and benchmarked against experimental results. Four experimental cases are examined. First, the simulated rectified sheath potentials on the antenna limiters are compared with measurements from a power tapering experiment. Second, proof-of-principle far-field sheath simulations are performed. In scenarios with low single-pass absorption, simulations predict enhanced sheath potentials on a distant poloidal limiter in the far field of the antenna, consistent with experimental observations. Third, the simulated antenna loading during edge localized modes follows experimental trends and appears to be dominated by the density gradient at the pedestal. Finally, Petra-M predicts the unintended excitation of high-$k$ ∥ modes during monopole phasing operation, in agreement with experimental evidence of poor wave coupling and accessibility to the plasma core. Overall, reasonable agreement is found between the simulations and experiments. At the same time, areas of imperfect agreement are identified. These provide important guidance on the limits of the current state-of-the-art modeling, which should be kept in mind when using it as a predictive tool for future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simple method to measure the interaction potential of dielectric grains in a dusty plasma

A simple minimally perturbative method is introduced which provides the ability to experimentally measure both the radial confining potential and the interaction potential between two individual dust particles, levitated in the sheath of a radio-frequency (RF) argon discharge. In this technique, a single dust particle is dropped into the plasma sheath to interact with a second individual dust particle already situated at the system's equilibrium point, without introducing any external perturbation. The resulting data are analyzed using a method employing a polynomial fit to the particle displacement(s), X(t), to reduce uncertainty in calculation. Employing this technique, the horizontal confinement is shown to be parabolic over a wide range of pressures and displacements from the equilibrium point. The interaction potential is also measured and shown to be well described by a screened Coulomb potential and to decrease with increasing pressure. Finally, the charge on the particle and the effective dust screening distance are calculated. It is shown for the first time experimentally that the charge on a particle in the sheath of an RF plasma decreases with increasing pressure, in agreement with theoretical predictions. The screening distance also decreases with increasing pressure as expected. This technique can be used for rapid determination of particle parameters in dusty plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Test of Instability-Enhanced Collisional Friction for Determining Ion Loss in Two Ion Species Plasmas

Recent experiments have shown that ions in weakly collisional plasmas containing two ion species of comparable densities nearly reach a common velocity at the sheath edge. A new theory suggests that collisional friction between the two ion species enhanced by two stream instability reduces the drift velocity of each ion species relative to each other near the sheath edge and finds that the difference in velocities at the sheath edge depends on the relative concentrations of the species. It is small when the concentrations are comparable and is large, with each species reaching its own Bohm velocity, when the relative concentration differences are large. To test these findings, ion drift velocities were measured with laser-induced fluorescence in argon-xenon plasmas. We show that the predictions are in excellent agreement with the first experimental tests of the new model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two Mechanisms Limiting the Emitted Electron Current from a Cathode to an Anode

It is known that the current of emitted electrons flowing through a plasma can saturate upon formation of a potential well adjacent to the cathode (the “space charge effect”). Here, we demonstrate another saturation mechanism that will often set a more restrictive limit on the global current. When “backflow saturation” occurs, the cathode sheath weakens to allow emitted electrons that already entered the plasma to backflow to the cathode. This effect could not be captured by studies modelling the cathode sheath by itself because its origin is coupled to processes in the interior plasma and anode sheath. By modeling a full plasma diode, we show that depending on conditions the global current can be limited in four ways; by backflow alone, by space charge alone, by both mechanisms in a stable cooperative form, or by both in a competing oscillatory form. Published by the American Physical Society 2025

Laboratory plasma↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled plasmas in argon

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this work, test particle simulations are used to describe the nature and role of the ballistic electrons, which originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased upper electrode and are then accelerated in the sheath toward the opposite non-dc biased lower electrode. This opposite electrode, on which a wafer is placed, may have rf bias power applied to it at low frequencies. 2 MHz is typical. While a hybrid dc/rf plasma source is sustained by the VHF power source, simulations reveal ballistic electrons assist in the production of a plasma characterized by a relatively high ionization rate constant, especially in the dc sheath. The dc source helps to provide a source of high energy electrons that may reach the wafer. However, when the rf bias is applied on the lower electrode, ballistic electrons are confined in the potential well formed between electrodes and easily thermalized in the bulk. The simulated electron density dependencies on the dc bias and lower electrode rf power describe a dual mode source and are consistent with measured data. When no rf power is applied on the electrode opposite to the dc power source, the bulk electron density drops with increasing dc power at constant VHF power; when rf power is applied to the electrode opposite to the dc power source, the bulk electron density increases with dc power at constant VHF power. The fraction of electrons significantly above thermal reaching the wafer is much higher when no rf power is applied at the lower electrode but the total flux lower. Depending on its level, rf power applied to the wafer may effectively suppress the number of ballistic electrons that reach the wafer. Finally, the ionization rate constant due to ballistic electrons can be fitted as a simple function of the electric field in the dc sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dusty plasma in the region of the lunar terminator

Dusty plasma in the region of the lunar terminator is considered. It is shown that, in this region, a structure resembling a plasma sheath forms near the lunar surface. This sheath creates a potential barrier, due to which electrons over the illuminated part of the Moon are confined by electrostatic forces. The width of the sheath-like structure is on the order of the ion Debye length. In this structure, significant (about several hundred V/m) electric fields arise, which lift charged micron-size dust grains to heights of several tens of centimeters. The suggested effect may be used to explain the glow observed by the Surveyor spacecraft over the lunar terminator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the ion energy spectrum in EUV-induced hydrogen plasma

The dynamics of the ion energy spectrum in low-pressure (10–100 Pa) hydrogen plasma induced by extreme ultraviolet (EUV) pulses in the wavelength range of 10–20 nm was studied experimentally. The plasma was generated under cathode irradiation due to both direct gas ionization by EUV photons and impact ionization by high-energy secondary electrons. The dynamics of the spectra of ions incident on the cathode was measured using a time-resolved retarding field energy analyzer. It is shown that the ion spectrum dynamics is completely determined by the time evolution of the cathode sheath. At low gas pressures (<20 Pa), the ion spectrum at early moments after the EUV pulse has a peaked shape, typical of a collisionless plasma sheath, and is mainly determined by the cathode voltage. As the pressure increases, the peak broadens and low energy ions appear in the spectrum due to ion collisions in the cathode sheath. An increase in the role of collisions with decreasing plasma density is also observed in the time evolution of ion spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron flow stability in magnetically insulated vacuum transmission lines.

We evaluate the stability of electron current flow in high-power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic (EM) transverse magnetic waves [R. C. Davidson et al., Phys. Fluids 27, 2332 (1984)] which is solved numerically to obtain growth rates for unstable modes in various sheath profiles. These results are compared with two-dimensional (2D) EM particle-in-cell (PIC) simulations of electron flow in high-power MITLs. We find that the macroscopic properties (charge and current densities and self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar-flow model of Davidson et al. Idealized simulations of sheared flow in electron sheaths yield growth rates for both long (diocotron) and short (magnetron) wavelength instabilities that are in good agreement with the dispersion analysis. We conclude that electron sheaths that evolve self-consistently from space-charged-limited emission of electrons from the cathode in well-resolved 2D EM PIC simulations form stable profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure, properties, and applications of polyacrylonitrile/carbon nanotube ( CNT ) fibers at low CNT loading

Abstract Bi‐component, polyacrylonitrile (PAN)/carbon nanotube (CNT) fibers were processed, at different core‐sheath area ratios, by gel spinning. A percolated CNT network at 10 wt% CNT in the sheath enhanced electrical conductivity as compared to the neat PAN fiber, while PAN polymer in the core contributed to the good mechanical properties. Fibers with relatively thin sheath allowed overall CNT loading as low as 3.7 wt% to be made with good electrical conductivity, and PAN stabilization by Joule heating was demonstrated. Such fibers with combined good mechanical properties and electrical conductivity can also potentially be used for electrical heating of fabrics, for making smart textiles, and for electromagnetic interference shielding.

Lu, Mingxuan↗

Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and {>=}6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Vein Dilatation Prior to Concomitant Port Implantation

Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Difficult Removal of Retrievable IVC Filters: A Description of the 'Double-Wire Restraining' Technique

We describe our experience with the use of the 'double-wire restraining' technique to assist in the removal of two retrievable inferior vena cava filters: one had been misplaced in the right brachiocephalic vein with apex perforation of the vessel wall, and the second filter had migrated cephalad to straddle across both renal veins. The 'double-wire restraining' technique consists of two stiff-shaft Glidewires (Terumo, Somerset, NJ) placed through the same introducer sheath and positioned on opposite sides of the filter. Both wires restrain the filter at the tip of the sheath as the sheath is advanced, thus allowing the operator to reposition the filter. This report details how this technique was used to realign two malpositioned filters and reposition the filter apices from their extravascular location, thus exposing them for ensnarement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transseptal Guidewire Stabilization for Device Closure of a Large Pulmonary Arteriovenous Malformation

A 46-year-old man presenting with massive hemoptysis was found to have a large pulmonary arteriovenous malformation (PAVM) in the right lung. Closure of the PAVM with an Amplatzer-type duct occluder was hampered by inability to advance the device delivery sheath into the PAVM due to vessel tortuosity and inadequate guidewire support. Atrial septal puncture was performed and a femorofemoral arteriovenous guidewire loop through the right pulmonary artery, PAVM, and left atrium was created. Traction on both ends of the guidewire loop allowed advancement of the device delivery sheath into the PAVM and successful completion of the procedure. Transseptal guidewire stabilization can be a valuable option during device closure of large PAVMs when advancement, stability, or kinking of the device delivery sheath is an issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Accuracy of Percutaneous Biopsy Using “Cross and Push” Technique for Patients Suspected with Malignant Biliary Strictures

PurposeVarious methods have been used to sample biliary strictures, including percutaneous fine-needle aspiration biopsy, intraluminal biliary washings, and cytological analysis of drained bile. However, none of these methods has proven to be particularly sensitive in the diagnosis of biliary tract malignancy. We report improved diagnostic accuracy using a modified technique for percutaneous transluminal biopsy in patients with this disease.Materials and MethodsFifty-two patients with obstructive jaundice due to a biliary stricture underwent transluminal forceps biopsy with a modified “cross and push” technique with the use of a flexible biopsy forceps kit commonly used for cardiac biopsies. The modification entailed crossing the stricture with a 0.038-in. wire leading all the way down into the duodenum. A standard or long sheath was subsequently advanced up to the stricture over the wire. A Cook 5.2-Fr biopsy forceps was introduced alongside the wire and the cup was opened upon exiting the sheath. With the biopsy forceps open, within the stricture the sheath was used to push and advance the biopsy cup into the stricture before the cup was closed and the sample obtained. The data were analysed retrospectively.ResultsWe report the outcomes of this modified technique used on 52 consecutive patients with obstructive jaundice secondary to a biliary stricture. The sensitivity and accuracy were 93.3 and 94.2 %, respectively. There was one procedure-related late complication.ConclusionWe propose that the modified “cross and push” technique is a feasible, safe, and more accurate option over the standard technique for sampling strictures of the biliary tree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypomyelinating leukodystrophy-associated missense mutation in HSPD1 blunts mitochondrial dynamics

Myelin-forming glial cells undergo dynamic morphological changes in order to produce mature myelin sheaths with multiple layers. In the central nervous system (CNS), oligodendrocytes differentiate to insulate neuronal axons with myelin sheaths. Myelin sheaths play a key role in homeostasis of the nervous system, but their related disorders lead not only to dismyelination and repeated demyelination but also to severe neuropathies. Hereditary hypomyelinating leukodystrophies (HLDs) are a group of such diseases affecting oligodendrocytes and are often caused by missense mutations of the respective responsible genes. Despite increasing identification of gene mutations through advanced nucleotide sequencing technology, studies on the relationships between gene mutations and their effects on cellular and subcellular aberrance have not followed at the same rapid pace. In this study, we report that an HLD4-associated (Asp-29-to-Gly) mutant of mitochondrial heat shock 60-kDa protein 1 (HSPD1) causes short-length morphologies and increases the numbers of mitochondria due to their aberrant fission and fusion cycles. In experiments using a fluorescent dye probe, this mutation decreases the mitochondrial membrane potential. Also, mitochondria accumulate in perinuclear regions. HLD4-associated HSPD1 mutant blunts mitochondrial dynamics, probably resulting in oligodendrocyte malfunction. This study constitutes a first finding concerning the relationship between disease-associated HSPD1 mutation and mitochondrial dynamics, which may be similar to the relationship between another disease-associated HSPD1 mutation (MitCHAP-60 disease) and aberrant mitochondrial dynamics. - Highlights: • The HLD4 mutant of HSPD1 decreases mitochondrial fission frequency. • The HLD4 mutant decreases mitochondrial fusion frequency. • Mitochondria harboring the HLD4 mutant exhibit slow motility. • The HLD4 mutant of HSPD1 decreases mitochondrial membrane potential. • HLD4-related diseases may be due to decreased mitochondrial dynamics.

60 APPLIED LIFE SCIENCES↗

Specific iron binding to natural sphingomyelin membrane induced by non-specific co-solutes

Sphingomyelin (SPM), a crucial phospholipid in the myelin sheath, plays a vital role in insulating nerve fibers. We hypothesize that iron ions selectively bind to the phosphatidylcholine (PC) template within the SPM membrane under near-physiological conditions, resulting in disruptions to membrane organization. These interactions could potentially contribute to the degradation of the myelin sheath, thereby playing a role in the development of neurodegenerative diseases. We utilized synchrotron-based X-ray spectroscopy and diffraction techniques to study the interaction of iron ions with a bovine spinal-cord SPM monolayer (ML) at the liquid-vapor interface under physiological conditions. The SPM ML serves as a model system, representing localized patches of lipids within a more complex membrane structure. The experiments assessed iron binding to the SPM membrane both in the presence of salts and with additional evaluation of the effects of various ion species on membrane behavior. Grazing incidence X-ray diffraction was employed to analyze the impact of iron binding on the structural integrity of the SPM membrane. Furthermore, our results demonstrate that iron ions in dilute solution selectively bind to the PC template of the SPM membrane exclusively at near-physiological salt concentrations (e.g., NaCl, KCl, KI, or CaCl 2 ) and are pH-dependent. In-significant binding was detected in the absence of these salts or at near-neutral pH with salts. The surface adsorption of iron ions is correlated with salt concentration, reaching saturation at physiological levels. In contrast, multivalent ions such as La 3+ and Ca 2+ do not bind to SPM under similar conditions. Notably, iron binding to the SPM membrane disrupts its in-plane organization, suggesting that these interactions may compromise membrane integrity and contribute to myelin sheath damage associated with neurological disorders.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental investigation on the effect of surface electric field in the growth of tungsten nano-tendril morphology due to low energy helium irradiation

The mechanisms responsible for and controlling the growth of tungsten nano-tendrils (or “fuzz”) under low-energy helium plasma exposure remain unclear. For the first time in nano-tendril experiments, the plasma sheath-produced electric field and the helium (He) ion energy have been decoupled, showing that the sheath electric field has little impact on nano-tendril growth, eliminating a possible cause for tendril growth. The well-established necessary growth conditions for W fuzz were maintained with He ion flux density Γ He > 10 21 He m –2 s –1 , surface temperature T s = 1273 K, He ion energy E He = 64 eV, and He ion fluence Φ He > 10 24 He m –2 . A grid is situated between the tungsten sample and plasma, with the grid and sample potentials independently controlled in order to control the electric field at the surface of the sample while maintaining the same incident He ion energy to the surface. A calculation of the potential profile in the drift space between the grid and sample was used to account for space charge and calculate the electric field at the surface of the sample. Tungsten fuzz formed at all electric fields tested, even near zero electric field. Also, the depth of the resulting W fuzz layer was unaltered by the electric field when compared to the calculated depth determined from an empirical growth model. The conclusion is that the sheath electric field is not necessary to cause the changes in surface morphology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗