Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Concept of Very-Asymmetric lepton Collider for dark matter search

Accelerator-based searches for dark matter are aiming for high sensitivity and need an experimental setup with high luminosity. This field of research is often called intensity frontier physics. One of the best motivated portals of interaction between dark matter and ordinary matter is a dark photon which could be observed as a resonance in the invariant mass of the decay products. Electron–positron collisions are known to be the cleanest interaction for such a study. In this paper we propose a scheme for a collider which allows for a luminosity of a few orders of magnitude higher than could be obtained in a conventional symmetric collider and with a few times higher accessible mass than is possible using a positron beam and a fixed target approach. The key concept is based on asymmetric energies: a high-energy circulating positron beam and a low-energy high-intensity electron beam, and optimization of the beam interaction region. We present here a configuration of a collision region of 10 MeV electron and 4 GeV positron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

G EANT 4 atomic relaxation data for transfermium nuclei (Z = 101–104)

Advanced theoretical methods can accurately calculate various atomic observables and predict electronic structure. Still, systematic computations of the radiative and non-radiative transition probabilities and energies are missing for the actinides and all the transfermium elements. However, these compilations are needed for comprehensive Monte-Carlo simulations (such as GEANT4) of the radioactive decay of transfermium nuclei. These simulations can forma basis for data analysis of experiments, especially with complex detection setups. Investigation of the transfermium nuclei is crucial for understanding the nature of the nuclear force. In this study, simulations based on data from the Jena Atomic Calculator (JAC) and the data from the Evaluated Atomic Data Library (EADL) present in GEANT4 were found compatible for the three elements Ba(Z = 56), U(Z = 92), and Fm(Z = 100), thus, validating the JAC calculations. For Z> 100, we also found sound agreement between simulations that used data generated with JAC and experimental results involving No(Z = 102) and Rf(Z = 104) isotopes. In conclusion, these results demonstrate that JAC can produce reliable atomic data sets for transfermium elements, which will assist in analyzing nuclear-decay-spectroscopy experiments.

GEANT4↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental design of a W-band corrugated waveguide for wakefield acceleration studies

Radiofrequency (RF) structures in the sub-terahertz (sub-THz) regime are of interest for applications in structure wakefield acceleration due to their compact size and potential for high gradients. Here, we present the design, fabrication, and experimental setup of a metallic corrugated waveguide at 110 GHz, optimized for the 42 MeV electron beam parameters at the Argonne Wakefield Accelerator (AWA). The emittance exchange (EEX) beamline at AWA was used to perform longitudinal bunch shaping for two cases: (1) a high decelerating gradient experienced by a single drive electron bunch about 250 μm long; (2) a high transformer ratio using a two-bunch train consisting of a triangularly shaped drive bunch followed by a long witness bunch to probe the wakefield. Preliminary experimental results are presented, and data analysis is ongoing.

43 PARTICLE ACCELERATORS↗

AC-LGADs Fermilab front-end electronics characterization

Here, we characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the time resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than 2 p s at the 1 σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

Design and commissioning of the Correlated Gamma-Neutron Array for sCattering (CoGNAC)

The Correlated Gamma-Neutron Array for sCattering (CoGNAC) is a dual $n$-$γ$ detector array fielded at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center. Here, the detector array utilizes elpasolite detectors and liquid scintillators to perform measurements of neutron elastic and inelastic scattering cross sections and emitted particle angular distributions. This manuscript details the design and experimental setup of CoGNAC as well as some of the preliminary studies performed to select the elpasolite detectors deployed in the array. Examples of the analysis methods available to CoGNAC are given in the context of past CoGNAC measurements of neutron scattering reactions on 28 Si and 56 Fe.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution laser system for the S 3 -Low Energy Branch

Here, in this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S 3 -Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S 3 . The measured isotope-shift and hyperfine structure data are presented for stable isotopes of these elements. The erbium isotopes were studied using the 4f 12 6s 2 3 H 6 → 4f 12 ( 3 H)6s6p J = 5 atomic transition (415 nm) and the tin isotopes were studied by the 5s 2 5p 2 ( 3 P 0 ) → 5s 2 5p6s( 3 P 1 ) atomic transition (286.4 nm), and are used as a benchmark of the laser setup. Additionally, the tin isotopes were studied by the 5s 2 5p6s( 3 P 1 ) → 5s 2 5p6p( 3 P 2 ) atomic transition (811.6 nm), for which new isotope-shift data was obtained and the corresponding field-shift F 812 and mass-shift M 812 factors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance evaluation of the SPES FEBIAD ion source

SPES (Selective Production of Exotic Species) is the Radioactive Ion Beam (RIB) facility that is currently in the installation phase at the Istituto Nazionale di Fisica Nucleare in the Laboratori Nazionali di Legnaro (LNL-INFN). The main purpose of the facility is to deliver neutron-rich radioactive beams with a range of mass between 60 and 160 amu produced as fission products originated within a Uranium Carbide (UC x ) target impinged by high energy protons (40–70 MeV). In the last few years, the SPES group and their collaborators have focused on multiple aspects: development of various ISOL targets, ion sources, a high-power beam dump, versatile Front-End designs, primary proton beam and RIB diagnostics, design of beam optic components, and remote target handling. The development and optimization of ionization sources represents one of the most important R&D activities. The collaboration between SPES and ISOLDE (CERN) groups has enabled the evaluation of the performances of a novel FEBIAD ion source taking advantage of the ISOLDE off-line Front-End. In this paper, the results of efficiency and transversal emittance measurements of the new SPES FEBIAD ion source are presented and discussed. Particular attention is dedicated to the description of the experimental setup and to the comparison of experimental data with simulation to promote the reproducibility of the experimental tests with other types of sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First feedback-controlled divertor detachment in W7-X: Experience from TDU operation and prospects for operation with actively cooled divertor

In the last experimental campaign (OP1.2b) of the stellarator Wendelstein 7-X (W7-X), boronisation as a mean for first wall conditioning was applied for the first time which led to strongly reduced impurity fluxes from plasma-facing components. Thermal detachment at the uncooled target plates of the test divertor unit (TDU) was reached at higher plasma densities and was accompanied by high recycling of neutrals at the target plate. A feedback control system was established in W7-X to actively control the gas injection (actuator) for plasma fuelling and impurity seeding [3] through the divertors. It allowed very successful stabilisation of the detached plasma condition state as well as mitigation of thermal overloads to some baffle tiles. Different routinely available diagnostic signals were used as input parameters (sensors). We describe the setup of the feedback control system, its performance and provide some example results with the main focus on the development of the control scheme which led to the detachment stabilisation over the entire longest (30 s) high-power discharge at W7-X so far. In view of the achieved very successful detachment stabilisation and the necessity to include simultaneous optimisation of the core performance in the future, the feedback control system is being upgraded for the upcoming campaign (OP2.1) in which the water cooled and hereby inherently steady-state capable divertor has been currently installed. The prospects and some experiment ideas for active detachment control are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated modeling of boron powder injection for real-time plasma-facing component conditioning

An integrated modeling framework for investigating the application of solid boron (B) powder injection for real-time surface conditioning of plasma-facing components (PFCs) in tokamak environments is presented. Utilizing the DIII-D impurity powder dropper (IPD) setup, this study simulates B powder injection scenarios ranging from milligrams to tens of milligrams per second, corresponding to boron flux rates of 10 20 –10 21 B/s in standard L-mode conditions. The comprehensive modeling approach combines EMC3-EIRENE for simulating the deuterium plasma background and the Dust Injection Simulator (DIS) for the ablation and transport of the boron powder particles. EMC3 trace impurity fluid modeling results show substantial boron transport to the inboard lower divertor, predominantly influenced by the main ion plasma flow. The dependency on powder particle size (5-250 µm) was found to be insignificant for the scenario considered. The effects of erosion and redeposition were considered to reconcile the discrepancies with experimental observations, which saw substantial deposition on the outer divertor plasma-facing components. For this purpose, the WallDYN3D code was updated to include boron sources within the plasma domain and integrated into the modeling framework. The mixed-material migration modeling shows evolving boron deposition patterns, suggesting the formation of mixed B-C layers or predominantly B coverage depending on the powder mass flow rate. While the modeling outcomes at lower B injection rates tend to align with DIII-D experimental observations, the prediction of near-pure boron layers at higher rates has yet to be experimentally verified in the carbon environment of the DIII-D tokamak. The extensive reach of boron layers found in the modeling suggests the need for modeling that encompasses the entire wall geometry for more accurate experimental correlations. This integrated approach sets a precedent for analyzing and applying real-time in-situ boron coating techniques in advanced tokamak scenarios, potentially extendable to ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-driven modeling of coarse mesh turbulence for reactor transient analysis using convolutional recurrent neural networks

Advanced nuclear reactors often exhibit complex thermal-fluid phenomena during transients. To accurately capture such phenomena, a coarse-mesh three-dimensional (3-D) modeling capability is desired for modern nuclear-system code. In the coarse-mesh 3-D modeling of advanced-reactor transients that involve flow and heat transfer, accurately predicting the turbulent viscosity is a challenging task that requires an accurate and computationally efficient model to capture the unresolved fine-scale turbulence. In this work, we propose a data-driven coarse-mesh turbulence model based on local flow features for the transient analysis of thermal mixing and stratification in a sodium-cooled fast reactor. The model has a coarse mesh setup to ensure computational efficiency, while it is trained by fine-mesh computational fluid dynamics (CFD) data to ensure accuracy. A novel neural network architecture, combining a densely connected convolutional network and a long-short-term-memory network, is developed that can efficiently learn from the spatial temporal CFD transient simulation results. The neural network model was trained and optimized on a loss-of flow transient and demonstrated high accuracy in predicting the turbulent viscosity field during the whole transient. The trained model's generalization capability was also investigated on two other transients with different inlet conditions. The study demonstrates the potential of applying the proposed data-driven approach to support the coarse-mesh multi-dimensional modeling of advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identifying the nature of the QCD transition in heavy-ion collisions with deep learning

In this proceeding, we review our recent work using deep convolutional neural network (CNN) to identify the nature of the QCD transition in a hybrid modeling of heavy-ion collisions. Within this hybrid model, a viscous hydrodynamic model is coupled with a hadronic cascade “after-burner”. As a binary classification setup, we employ two different types of equations of state (EoS) of the hot medium in the hydrodynamic evolution. The resulting final-state pion spectra in the transverse momentum and azimuthal angle plane are fed to the neural network as the input data in order to distinguish different EoS. To probe the effects of the fluctuations in the event-by-event spectra, we explore different scenarios for the input data and make a comparison in a systematic way. We observe a clear hierarchy in the predictive power when the network is fed with the event-by-event, cascade-coarse-grained and event-fine-averaged spectra. The carefully-trained neural network can extract high-level features from pion spectra to identify the nature of the QCD transition in a realistic simulation scenario.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗