Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensitivity study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Dark matter sensitivity of multi-ton liquid xenon detectors

We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account realistic backgrounds from the detector itself as well as from neutrinos, we examine the impact of exposure, energy threshold, background rejection efficiency and energy resolution on the dark matter sensitivity. With an exposure of 200 t × y and assuming detector parameters which have been already demonstrated experimentally, spin-independent cross sections as low as 2.5 × 10{sup −49} cm{sup 2} can be probed for WIMP masses around 40 GeV/c{sup 2}. Additional improvements in terms of background rejection and exposure will further increase the sensitivity, while the ultimate WIMP science reach will be limited by neutrinos scattering coherently off the xenon nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-sensitive atomic magnetometer for studying magnetization fields produced by hyperpolarized helium-3

An ingenious approach to acquire the absolute magnetization fields produced by polarized atoms has been presented in this paper. The method was based on detection of spin precession signal of the hyperpolarized helium-3 with ultra-sensitive atomic magnetometer of potassium by referring to time-domain analysis. At first, dynamic responses of the mixed spin ensembles in the presence of variant external magnetic fields have been analyzed by referring to the Bloch equation. Subsequently, the relevant equipment was established to achieve the functions of hyperpolarizing helium-3 and detecting the precession of spin-polarized noble gas. By analyzing the transient response of the magnetometer in time domain, we obtained the relevant damping ratio and natural frequency. When the value of damping ratio reached the maximum value of 0.0917, the combined atomic magnetometer was in equilibrium. We draw a conclusion from the steady response: the magnetization fields of the polarized electrons and the hyperpolarized nuclei were corresponding 16.12 nT and 90.74 nT. Under this situation, the nuclear magnetization field could offset disturbing magnetic fields perpendicular to the orientation of the electronic polarization, and it preserved the electronic spin staying in a stable axis. Therefore, the combined magnetometer was particularly attractive for inertial measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Benefits of an Energy Imbalance Market in the NWPP

The Northwest Power Pool (NWPP) Market Assessment Committee (MC) Initiative, which was officially launched on March 19, 2012, set out to explore a range of alternatives that could help the Balancing Authorities and scheduling utilities in the NWPP area address growing operational and commercial challenges affecting the regional power system. The MC formed an Analytical Team with technical representatives from each of the member Balancing Areas in the NWPP and with staff of Pacific Northwest National Laboratory (PNNL). This Analytical Team was instructed to conduct extensive studies of intra-hour operation of the NWPP system in the year 2020 and of the NWPP region with 14,671 MW of wind penetration. The effort utilized a sub-hourly production cost model (the PLEXOS® computer model) that inputs data from the Western Electricity Coordinating Council (WECC)-wide Production Cost Model (PCM) to evaluate potential production cost savings. The Analytical Team was given two general options to evaluate: •Energy Imbalance Market (EIM): establishment of an automated, organized NWPP area market for economically supplying energy imbalance within the hour. •Enhanced Market-Operational Tools (EMT) that might augment or replace an EIM. The Analytical The Analytical Team built on the WECC-wide PCM data from prior work done in the WECC and carried forward the evolution of the original WECC Transmission Expansion Planning Policy Committee (TEPPC) 2020 PC0 data base. A large number of modifications and improvements were made to this case and the data were subjected to extensive review by the team members to improve the model representation of the Northwest (NW). MC meetings that were open to the public were held for interested parties to review and provide input to the study. Results for the test, base, and sensitivity case studies performed by the MC Initiative Analytical Team indicate that there are a wide range of benefits that could be obtained from the operation of an EIM in the NWPP depending on what assumptions are made. The instructions from the MC were to determine a "minimum high confidence" range of potential benefits. The results for the Base Case indicate that the EIM benefits ranged from approximately $40 million to $70 million in annual savings from the operation of an EIM in the NWPP footprint. A number of additional relevant sensitivity cases were performed, including low and high water conditions, low and high natural gas prices, and various flex reserve requirements, resource operations, and amounts of resource capability held back during the preschedule period. Along with the results for the Base Case, the results for these studies yielded EIM benefits that clustered within the range of $70 to $80 million dollars per year with potential benefits ranging from approximately $125 million to as little as $17 million per year. Because the design and operation of an EIM could enable participating Balancing Authorities (BAs) to collectively lower the quantity of resources they must carry to meet within-hour balancing needs, a sensitivity case was also performed to analyze the impact that such reductions might have on the benefits from an EIM. The results for this sensitivity case indicate that such reductions could increase the benefits from the operation of an EIM in the NWPP into the range of approximately $130 million to $160 million per year. Also, a sensitivity case for a WECC-wide EIM was performed with the results indicating that the potential benefits to the NWPP could increase into the range of $197 million to $233 million per year. While there may be potential reliability benefits from the coordinated dispatch process underlying the operation of an EIM, reliability benefits from an EIM were out of the scope of this study. The EIM benefit analyses that were performed by the Analytical Team are provided in this report.

Power markets, NWPP, Energy Imbalance, EIM, Renewa↗

A Comparative Study of the Perceptual Sensitivity of Topological Visualizations to Feature Variations

Color maps are a commonly used visualization technique in which data are mapped to optical properties, e.g., color or opacity. Color maps, however, do not explicitly convey structures (e.g., positions and scale of features) within data. Topology-based visualizations reveal and explicitly communicate structures underlying data. Although our understanding of what types of features are captured by topological visualizations is good, our understanding of people's perception of those features is not. Further, this paper evaluates the sensitivity of topology-based isocontour, Reeb graph, and persistence diagram visualizations compared to a reference color map visualization for synthetically generated scalar fields on 2-manifold triangular meshes embedded in 3D. In particular, we built and ran a human-subject study that evaluated the perception of data features characterized by Gaussian signals and measured how effectively each visualization technique portrays variations of data features arising from the position and amplitude variation of a mixture of Gaussians. For positional feature variations, the results showed that only the Reeb graph visualization had high sensitivity. For amplitude feature variations, persistence diagrams and color maps demonstrated the highest sensitivity, whereas isocontours showed only weak sensitivity. These results take an important step toward understanding which topology-based tools are best for various data and task scenarios and their effectiveness in conveying topological variations as compared to conventional color mapping.

97 MATHEMATICS AND COMPUTING↗

SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

60 APPLIED LIFE SCIENCES↗

Application of an Online-Coupled Regional Climate Model, WRF-CAM5, over East Asia for Examination of Ice Nucleation Schemes: Part II. Sensitivity to Heterogeneous Ice Nucleation Parameterizations and Dust Emissions

Aerosol particles can affect cloud microphysical properties by serving as ice nuclei (IN). Large uncertainties exist in the ice nucleation parameterizations (INPs) used in current climate models. In this Part II paper, to examine the sensitivity of the model predictions to different heterogeneous INPs, WRF-CAM5 simulation using the INP of Niemand et al. (N12) [1] is conducted over East Asia for two full years, 2006 and 2011, and compared with simulation using the INP of Meyers et al. (M92) [2], which is the original INP used in CAM5. M92 calculates the nucleated ice particle concentration as a function of ice supersaturation, while N12 represents the nucleated ice particle concentration as a function of temperature and the number concentrations and surface areas of dust particles. Compared to M92, the WRF-CAM5 simulation with N12 produces significantly higher nucleated ice crystal number concentrations (ICNCs) in the northern domain where dust sources are located, leading to significantly higher cloud ice number and mass concentrations and ice water path, but the opposite is true in the southern domain where temperatures and moistures play a more important role in ice formation. Overall, the simulation with N12 gives lower downward shortwave radiation but higher downward longwave radiation, cloud liquid water path, cloud droplet number concentrations, and cloud optical depth. The increase in cloud optical depth and the decrease in downward solar flux result in a stronger shortwave and longwave cloud forcing, and decreases temperature at 2-m and precipitation. Changes in temperature and radiation lower surface concentrations of OH, O3, SO42−, and PM2.5, but increase surface concentrations of CO, NO2, and SO2 over most of the domain. By acting as cloud condensation nuclei (CCN) and IN, dust particles have different impacts on cloud water and ice number concentrations, radiation, and temperature at 2-m and precipitation depending on whether the dominant role of dust is CCN or IN. These results indicate the importance of the heterogeneous ice nucleation treatments and dust emissions in accurately simulating regional climate and air quality.

54 ENVIRONMENTAL SCIENCES↗

Comprehensive Mechanisms for Combustion Chemistry: An Experimental and Numerical Study with Emphasis on Applied Sensitivity Analysis

This project was an integrated experimental/numerical effort to study pyrolysis and oxidation reactions and mechanisms for small-molecule hydrocarbon structures under conditions representative of combustion environments. The experimental aspects of the work were conducted in large-diameter flow reactors, at 0.3 to 18 atm pressure, 500 to 1100 K temperature, and 10 -2 to 2 seconds reaction time. Experiments were also conducted to determine reference laminar flame speeds using a premixed laminar stagnation flame experiment and particle image velocimetry, as well as pressurized bomb experiments. Flow reactor data for oxidation experiments include: (1)adiabatic/isothermal species time-histories of a reaction under fixed initial pressure, temperature, and composition; to determine the species present after a fixed reaction time, initial pressure; (2)species distributions with varying initial reaction temperature; (3)perturbations of a well-defined reaction systems (e.g. CO/H 2 /O 2 or H 2 /O 2 )by the addition of small amounts of an additive species. Radical scavenging techniques are applied to determine unimolecular decomposition rates from pyrolysis experiments. Laminar flame speed measurements are determined as a function of equivalence ratio, dilution, and unburned gas temperature at 1 atm pressure. Hierarchical, comprehensive mechanistic construction methods were applied to develop detailed kinetic mechanisms which describe the measurements and literature kinetic data. Modeling using well-defined and validated mechanisms for the CO/H 2 /Oxidant systems and perturbations of oxidation experiments by small amounts of additives were also used to derive absolute reaction rates and to investigate the compatibility of published elementary kinetic and thermochemical information. Numerical tools were developed and applied to assess the importance of individual elementary reactions to the predictive performance of the developed mechanisms and to assess the uncertainties in elementary rate constant evaluations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of the transverse flow to the symmetry energy

We study the sensitivity of transverse flow to symmetry energy in the Fermi energy region as well as at high energies. We find that transverse flow is sensitive to symmetry energy and its density dependence in the Fermi energy region. We also show that the transverse flow can address the symmetry energy at densities about twice the saturation density; however, it shows insensitivity to the symmetry energy at densities {rho}/{rho}{sub 0}>2. The mechanism for the sensitivity of transverse flow to symmetry energy and its density dependence is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exponential Decay in the Sensitivity Analysis of Nonlinear Dynamic Programming

In this report, we study the sensitivity of discrete-time dynamic programs with nonlinear dynamics and objective to perturbations in the initial conditions and reference parameters. Under uniform controllability and boundedness assumptions for the problem data, we prove that the directional derivative of the optimal state and control at time $k$, $x^*_k$, and $u^*_k$, with respect to the reference signal at time $i$, $d_i$, will have exponential decay in terms of $|k-i|$ with a decay rate $\rho$ independent of the temporal horizon length. The key technical step is to prove that a version of the convexification approach proposed by Verschueren et al. can be applied to the KKT conditions and results in a convex quadratic program with uniformly bounded data. In turn, Riccati techniques can be further employed to obtain the sensitivity result, borne from the observation that the directional derivatives are solutions of quadratic programs with structure similar to the KKT conditions themselves. We validate our findings with numerical experiments on a small nonlinear, nonconvex, dynamic program.

97 MATHEMATICS AND COMPUTING↗

Log-N/Period Power Offset Sensitivity Calculation

This study focused on the calculation of sensitivity values for Channels 4 and 5 in the Log-N/Period system at the Advanced Test Reactor (ATR). The Log-N/Period system provides an indication of reactor power generation between criticality and full power. This indication is determined by the power offset and the current produced by the detector. Sensitivity values for Channels 4 and 5 were calculated using existing equations, documents, reactor startup data.

42 - ENGINEERING↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proof-of-Concept Study for Uncertainty Quantification and Sensitivity Analysis using the BRL Shaped-Charge Example

These are the slides for a graduate presentation at Mississippi State University. It covers the following: the BRL Shaped-Charge Geometry in PAGOSA, mesh refinement study, surrogate modeling using a radial basis function network (RBFN), ruling out parameters using sensitivity analysis (equation of state study), uncertainty quantification (UQ) methodology, and sensitivity analysis (SA) methodology. In summary, a mesh convergence study was used to ensure that solutions were numerically stable by comparing PDV data between simulations. A Design of Experiments (DOE) method was used to reduce the simulation space to study the effects of the Jones-Wilkins-Lee (JWL) Parameters for the Composition B main charge. Uncertainty was quantified by computing the 95% data range about the median of simulation output using a brute force Monte Carlo (MC) random sampling method. Parameter sensitivities were quantified using the Fourier Amplitude Sensitivity Test (FAST) spectral analysis method where it was determined that detonation velocity, initial density, C1, and B1 controlled jet tip velocity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beam-recoil polarization transfer in the nucleon resonance region in the exclusive e-vectorp{yields}e{sup '}K{sup +}{lambda}-vector and e-vectorp{yields}e{sup '}K{sup +}{sigma}-vector{sup 0} reactions at the CLAS spectrometer

Beam-recoil transferred polarizations for the exclusive e-vectorp{yields}e{sup '}K{sup +}{lambda}-vector,{sigma}-vector{sup 0} reactions have been measured using the Continuous Electron Beam Accelerator Facility's large acceptance spectrometer (CLAS) at the Thomas Jefferson National Accelerator Facility. New measurements have been completed at beam energies of 4.261 and 5.754 GeV that span a range of momentum transfer Q{sup 2} from 0.7 to 5.4 GeV{sup 2}, invariant energy W from 1.6 to 2.6 GeV, and the full center-of-mass angular range of the K{sup +} meson. These new data add to the existing CLAS K{sup +}{lambda} measurements at 2.567 GeV, and provide the first-ever data for the K{sup +}{sigma}{sup 0} channel in electroproduction. Comparisons of the data with several theoretical models are used to study the sensitivity to s-channel resonance contributions and the underlying reaction mechanism. Interpretations within two semiclassical partonic models are made to probe the underlying reaction mechanism and the ss quark-pair creation dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GREAT3 results - I. Systematic errors in shear estimation and the impact of real galaxy morphology

The study present first results from the third GRavitational lEnsing Accuracy Testing (GREAT3) challenge, the third in a sequence of challenges for testing methods of inferring weak gravitational lensing shear distortions from simulated galaxy images. GREAT3 was divided into experiments to test three specific questions, and included simulated space- and ground-based data with constant or cosmologically varying shear fields. The simplest (control) experiment included parametric galaxies with a realistic distribution of signal-to-noise, size, and ellipticity, and a complex point spread function (PSF). The other experiments tested the additional impact of realistic galaxy morphology, multiple exposure imaging, and the uncertainty about a spatially varying PSF; the last two questions will be explored in Paper II. The 24 participating teams competed to estimate lensing shears to within systematic error tolerances for upcoming Stage-IV dark energy surveys, making 1525 submissions overall. GREAT3 saw considerable variety and innovation in the types of methods applied. Several teams now meet or exceed the targets in many of the tests conducted (to within the statistical errors). We conclude that the presence of realistic galaxy morphology in simulations changes shear calibration biases by ~1 per cent for a wide range of methods. Other effects such as truncation biases due to finite galaxy postage stamps, and the impact of galaxy type as measured by the Sérsic index, are quantified for the first time. Our results generalize previous studies regarding sensitivities to galaxy size and signal-to-noise, and to PSF properties such as seeing and defocus. Almost all methods’ results support the simple model in which additive shear biases depend linearly on PSF ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗