Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

SAS PDF: pair distribution function analysis of nanoparticle assemblies from small-angle scattering data

SASPDF, a method for characterizing the structure of nanoparticle assemblies (NPAs), is presented. The method is an extension of the atomic pair distribution function (PDF) analysis to the small-angle scattering (SAS) regime. The PDFgetS3 software package for computing the PDF from SAS data is also presented. An application of the SASPDF method to characterize structures of representative NPA samples with different levels of structural order is then demonstrated. The SASPDF method quantitatively yields information such as structure, disorder and crystallite sizes of ordered NPA samples. The method was also used to successfully model the data from a disordered NPA sample. The SASPDF method offers the possibility of more quantitative characterizations of NPA structures for a wide class of samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Overview of recent turbulence studies across multiple confinement modes at the ASDEX Upgrade tokamak using the Correlation Electron Cyclotron Emission diagnostic

This work presents an overview of recent and ongoing experimental measurements of core and edge turbulence across multiple confinement regimes using the Correlation Electron Cyclotron Emission (CECE) diagnostic at the ASDEX Upgrade (AUG) tokamak. A common goal among these investigations is to identify how the properties of the turbulent electron temperature fluctuations measured by CECE influence and regulate the unique transport characteristics of each confinement regime, including L-mode, I-mode, ELMy H-mode, and ELM-free H-mode. Optics and signal processing methods to aid in the analysis and interpretation of experimental turbulence results are also presented. These methods, and particularly the down-sampling and ensemble averaging method, are relevant to a wide variety of fusion and non-fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical methods for the analysis of sampled-data systems and for the computation of system zeros

MARSYAS is a computer aided control system design package for the simulation and analysis of open loop and closed loop dynamic systems. Outlined here is the numerical and theoretical basis of the MARSYAS functions developed during the summer of 1991. In particular, the numerical computation of the matrix exponential e(exp A) = I + A + A(exp 2)/2! + A(exp 3)/3! + ... and the numerical computation of the finite system zeros of a dynamic system (continuous time or discrete time) are presented.

Hodel, A. Scottedward↗

Numerical methods for the analysis of sampled-data systems and for the computation of system zeros

MARSYAS is a computer-aided control system design package for the simulation and analysis of dynamic systems. In the summer of 1991 MARSYAS was updated to allow for the analysis of sampled-data systems in terms of frequency response, stability, etc. This update was continued during the summer of 1992 in order to extend further MARSYAS commands to the study of sampled-data systems. Further work was done to examine the computation of OPENAT transfer functions, root-locii and w-plane frequency response plots.

Hodel, A. Scottedward↗

Water Quality Monitor

In the photo above, the cylindrical container being lowered into the water is a water quality probe developed by NASA's Langley Research Center for the Environmental Protection Agency (EPA) in an applications engineering project. It is part of a system- which also includes recording equipment in the helicopter-for on-the-spot analysis of water samples. It gives EPA immediate and more accurate information than the earlier method, in which samples are transported to a lab for analysis. Designed primarily for rapid assessment of hazardous spills in coastal and inland waters, the system provides a wide range of biological and chemical information relative to water pollution.

Source record↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

A rapid thioacidolysis method for biomass lignin composition and tricin analysis

Abstract Background Biomass composition varies from plant to plant and greatly affects biomass utilization. Lignin is a heterogeneous phenolic polymer derived mainly from p -coumaryl, coniferyl, and sinapyl alcohols and makes up to 10–25% of lignocellulosic biomass. Recently, tricin, an O -methylated flavone, was identified as a lignin monomer in many grass species. Tricin may function as a nucleation site for lignification and is advocated as a novel target for lignin engineering to reduce lignin content and improve biomass digestibility in grasses. Thioacidolysis is an analytical method that can be adapted to analyze both lignin monomeric composition and tricin content in the lignin polymer. However, the original thioacidolysis procedure is complex, laborious, and time consuming, making it difficult to be adopted for large-scale screening in biomass research. In this study, a modified, rapid higher throughput thioacidolysis method was developed. Results In combination with gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), the modified thioacidolysis method can be used to simultaneously characterize the lignin composition and tricin content using 2–5 mg of dry samples. The modified method eliminates the solvent extraction and drastically improves the throughput; 80 samples can be processed in one day per person. Our results indicate that there is no significant difference in the determination of lignin S/G ratio and tricin content between the original and modified methods. Conclusions A modified thioacidolysis protocol was established. The results demonstrate that the modified method can be used for rapid, high-throughput, and reliable lignin composition and tricin content analyses for screening transgenic plants for cell wall modifications or in large-scale genome-wide association studies (GWAS).

09 BIOMASS FUELS↗

Quantifying Microstructure Variability in Laser Powder Bed Fusion 316 L Stainless Steel Microstructures with Spatial Statistics

Here, we have explored data-driven methods for material microstructure quantification that improve sensitivity to microstructural changes compared to traditional approaches. The methods integrate multiple microstructural properties, including grain morphology, crystallographic orientation, and material phase information. The simpler method employs maps of the Euclidean distance transformation metric to evaluate the morphology of grain boundary networks. The more intensive approach employs generalized spherical harmonic mapping for crystallographic orientations, per-pixel phase information, and a variational auto-encoder for dimensionality reduction and results in a multidimensional clustering of by microstructure similarity. Applied to an experimental dataset of additively manufactured steel, both methods detected slight variations in samples produced under nominally identical processing conditions. Both methods were able to distinguish between samples from multiple (nominally identical) builds, while the generalized spherical harmonics-based method could additionally cluster data samples rotated at two orientations on the build plate. The improved sensitivity of the methods, demonstrated through comparison with traditional microstructure characterization techniques, offers advantages for microstructure quantification and comparisons in advanced manufacturing applications.

SS316L↗

Directional acceleration vector-driven displacement of fluids (DAVD-DOF)

Centrifugal analyzer and method for staining biological or non-biological samples in microgravity, wherein the method utilizes an increase in weight of a fluid sample as a function of g-load, to overcome cohesive and frictional forces from preventing its movement in a preselected direction. Apparatus is characterized by plural specimen reservoirs and channels in a slide, each channel being of differing cross-section, wherein respective samples are selectively dispensed, from the reservoirs in response to an imposed g-factor, precedent to sample staining. Within the method, one thus employs microscope slides which define channels, each being of a differing cross-section dimension relative to others. In combination therewith, centrifugal slide mounting apparatus controllably imposes g-vectors of differing magnitudes within a defined structure of the centrifuge such as a chip array.

Clarke, Mark S. F.↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

East River Surface and Pore Water FTICR-MS Data Associated with “Implications of sample treatment on characterization of the riverine environmental metabolome”

Surface and pore water samples were collected from distributed locations around Meander A in East River (Crested Butte, CO, USA) during the summer of 2018. This dataset consists of the characterization of dissolved organic matter using 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS; in .xml format) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory) using two different sample pre-treatment methods (solid phase extraction, no solid phase extraction) and two electrospray ionization methods (ESI-positive, ESI-negative) to identify the impacts of these choices on the final dataset. This study aimed to understand how the different sample processing methods influence the resulting FTICR-MS dataset. Any published work that utilizes data presented in this dataset should cite the dataset using the DOI number. If using the dataset, please acknowledge the U.S. Department of Energy (DOE) Office of Science (BER) Subsurface Biogeochemical Research (SBR) program, the Environmental Molecular Sciences Laboratory (EMSL), and Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS). The publication DOI will be added to this abstract when available.

54 ENVIRONMENTAL SCIENCES↗

Realistic Covariance Generation for the GPM Spacecraft

We present several different methods for generating realistic predictive covariance, including Monte-Carlo simulations and more direct linear methods which require the addition of process noise. The Monte-Carlo simulation starts with an epoch uncertainty sample basis and propagates each trial to a time of interest in the future. The variance-covariance of the state elements as well as other higher order sample statistics can be readily computed from the propagated sample. While this method preserves the nonlinear effects on the propagated uncertainty, it is computationally intensive as a statistically significant sample size must be considered in the propagation process. Moreover, if the epoch covariance is optimistic, this can result in an underestimation of the prediction error. Another method is to propagate a state sensitivity matrix simultaneously with the satellite state, which allows the epoch covariances to be propagated forward in a linear fashion. This method does not preserve the non-linearity of the satellite state uncertainty but is much less computationally intensive. The propagated state covariance is the scaled to represent the realistic level of GPM state uncertainty via a "e-tuning process." The tuning process generates an inflation factor based on the observed error statistics of the predictive satellite trajectories when compared to the definitive ones. Difference tuning strategies are considered and compared via Goodness-of-Fit method testing for the Gaussian properties of the scaled covariance.

prediction error↗

Techniques for the analysis of gases sequentially released from lunar samples

Description of two methods for the analysis of light gases that are sequentially evolved from 2 to 10 mg of lunar sample. A hydrofluoric acid hydrolysis of lunar material is achieved by repeated exposure of the sample to hydrogen fluoride. In the second technique, gases are evolved from lunar samples by the stepwise heating of these samples to 1400 C. The gases evolved by either hydrolysis or pyrolysis are analyzed in a gas chromatographic system using a helium ionization detector. The sensitivities of this detector for the gases, as analyzed, range from 20 picograms/sec for hydrogen to 0.2 picogram/sec for carbon dioxide.

Desmarais, D. J.↗

Adaptive Sampling-Based Bi-Fidelity Stochastic Trust Region Method for Stochastic Derivative-Free Optimization

Bi-fidelity stochastic optimization has gained increasing attention as an efficient approach to reduce computational costs by leveraging a low-fidelity (LF) model to optimize an expensive high-fidelity (HF) objective. In this paper, we propose ASTRO-BFDF, an adaptive sampling trust-region method specifically designed for unconstrained bi-fidelity stochastic derivative-free optimization problems. In ASTRO-BFDF, the LF function serves two purposes: (i) to identify better iterates for the HF function when the optimization process indicates a high correlation between them and (ii) to reduce the variance of the HF function estimates using bi-fidelity Monte Carlo (BFMC). The algorithm dynamically determines sample sizes while adaptively choosing between crude Monte Carlo and BFMC to balance the trade-off between optimization and sampling errors. We prove that the iterates generated by ASTRO-BFDF converge to a first-order stationary point almost surely. Additionally, we demonstrate the effectiveness of the proposed algorithm through numerical experiments on synthetic benchmarks and simulation optimization problems involving discrete event systems.

97 MATHEMATICS AND COMPUTING↗