Oxygen vacancies in niobium pentoxide as a source of two-level system losses in superconducting niobium

Two-level systems (TLS) have long been a catch-all explanation for RF loss and quantum decoherence in superconducting devices. In our study, the first to directly link TLS losses to a specific physical mechanism, we demonstrate that oxygen vacancies in the naturally formed Nb₂O₅ on oxidized niobium are a major driver of such dissipation. We performed sequential in situ vacuum-baking treatments on niobium superconducting radio-frequency (SRF) cavities and used time-of-flight secondary ion mass spectrometry (TOF-SIMS) to reveal a nonmonotonic evolution in cavity quality factor (Q₀). This behavior correlates with the interplay of Nb₂O₅ vacancy generation and oxide-thickness dissolution. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, revealing a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss. Although our measurements center on 3-D SRF cavities, the insights gained here have significant implications for mitigating decoherence in 2-D superconducting qubits.

Bafia, Daniel P. [Fermilab]↗

First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited)

The next generation heavy ion accelerator facility, such as the RIKEN radio isotope (RI) beam factory, requires an intense beam of high charged heavy ions. In the past decade, performance of the electron cyclotron resonance (ECR) ion sources has been dramatically improved with increasing the magnetic field and rf frequency to enhance the density and confinement time of plasma. Furthermore, the effects of the key parameters (magnetic field configuration, gas pressure, etc.) on the ECR plasma have been revealed. Such basic studies give us how to optimize the ion source structure. Based on these studies and modern superconducting (SC) technology, we successfully constructed the new 28 GHz SC-ECRIS, which has a flexible magnetic field configuration to enlarge the ECR zone and to optimize the field gradient at ECR point. Using it, we investigated the effect of ECR zone size, magnetic field configuration, and biased disk on the beam intensity of the highly charged heavy ions with 18 GHz microwaves. In this article, we present the structure of the ion source and first experimental results with 18 GHz microwave in detail.

43 PARTICLE ACCELERATORS↗

Poynting-vector based method for determining the bearing and location of electromagnetic sources

A method and apparatus is utilized to determine the bearing and/or location of sources, such as, alternating current (A.C.) generators and loads, power lines, transformers and/or radio-frequency (RF) transmitters, emitting electromagnetic-wave energy for which a Poynting-Vector can be defined. When both a source and field sensors (electric and magnetic) are static, a bearing to the electromagnetic source can be obtained. If a single set of electric (E) and magnetic (B) sensors are in motion, multiple measurements permit location of the source. The method can be extended to networks of sensors allowing determination of the location of both stationary and moving sources.

Simons, David J↗

Simulation of plasma and neutral transport in PISCES-RF using SOLPS-ITER

In this research, the fluid plasma transport code SOLPS-ITER is applied and validated against experimental data from the plasma interaction surface component experimental station (PISCES)-RF linear plasma device to establish a physics basis for plasma and neutral transport in its two magnetic field (B-field) geometry setups-(1)the cusp and (2) non-cusp or linear B-field. The main focus of this study is to understand (1) radial plasma transport (2) heat and particle loads on the upstream dump and downstream target plate, and (3) the physics of plasma-neutral interactions in PISCES-RF. The simulation setup adheres to typical PISCES-RF experimental conditions, with a 2D helicon power deposition profile as an input heating source. SOLPS-ITER simulations reproduce experimental conditions with the Bohm diffusion model for both B-field configurations of the PISCES-RF experiment. Major energy loss channels include neutral radiation and power deposited on the wall and dump plate, with only 1% of the input power reaching the target. The ionization front is well confined near the dump plate due to the heating and puffing regions. Additionally, SOLPS-ITER simulation results are also found to be in very good agreement with the particle-in-cell calculations using the code-PICOS++ which supports the validity of SOLPS in low collisionality regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of personal radio frequency electromagnetic field exposure in different urban areas across Europe

Background: Only limited data are available on personal radio frequency electromagnetic field (RF-EMF) exposure in everyday life. Several European countries performed measurement studies in this area of research. However, a comparison between countries regarding typical exposure levels is lacking. Objectives: To compare for the first time mean exposure levels and contributions of different sources in specific environments between different European countries. Methods: In five countries (Belgium, Switzerland, Slovenia, Hungary, and the Netherlands), measurement studies were performed using the same personal exposure meters. The pooled data were analyzed using the robust regression on order statistics (ROS) method in order to allow for data below the detection limit. Mean exposure levels were compared between different microenvironments such as homes, public transports, or outdoor. Results: Exposure levels were of the same order of magnitude in all countries and well below the international exposure limits. In all countries except for the Netherlands, the highest total exposure was measured in transport vehicles (trains, car, and busses), mainly due to radiation from mobile phone handsets (up to 97%). Exposure levels were in general lower in private houses or flats than in offices and outdoors. At home, contributions from various sources were quite different between countries. Conclusions: Highest total personal RF-EMF exposure was measured inside transport vehicles and was well below international exposure limits. This is mainly due to mobile phone handsets. Mobile telecommunication can be considered to be the main contribution to total RF-EMF exposure in all microenvironments.

60 APPLIED LIFE SCIENCES↗

A High Power CW Input Coupler with Reduced Static and Dynamic Losses

Each niobium cavity employed in superconducting accelerators requires a power coupler that supplies it with up to hundreds of kW’s of CW RF power, which is delivered to the 2K or 4K cold cavity from a Room Temperature (RT) source. Coupler design is a challenging task. It should transmit the minimum possible thermal power flow to the cavity, because a single watt at 2K requires 1 kW of cryogenic system power to remove it. Since the coupler connects the cold cavity to a Room Temperature (RT) power source, it transmits a static thermal load due to its thermal conductivity. Also, the coupler experiences heating by RF fields. This dissipated power partially penetrates to the 2K zone, and is called a dynamic load. From one point of view, the coupler should have low thermal conductivity, in order to decrease the static load. Stainless steel (SS) is usually used for that reason, but it also has low electrical conductivity, which introduces a high dynamic load. Copper plating on the SS is required to improve the electrical conductivity, but it is not reliable and often flakes. One copper flake might cause an electrical discharge and contaminate the surface of the niobium cavity, thus spoiling its Q-factor. In that case, decommissioning of the entire cryomodule is required to restore the cavity Q-factor, which means it is a tremendously expensive procedure. That is why an improved reliability coupler is of very high interest. As a result, the main idea of the proposed project is to completely eliminate the unreliable copper plating by employing solid copper shields to screen the SS pipe from RF fields.

43 PARTICLE ACCELERATORS↗

A neutron diagnostic for high current deuterium beams

A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Portable 950 keV X-band Linac for NDT

We are developing a portable 950 keV X-band (9.4 GHz) linac X-ray source for on-site nondestructive testing of erosion of metal pipes at a petrochemical complex. To develop it, we adopted a compact X-band 9.4 GHz magnetron of 250 kW for RF generation device. The whole device, including power supply and cooling devices, were also downsized. The dose rate of X-ray converted in a tungsten target is designed to be 0.2 Gy/min at 1-m distance. We designed an accelerating tube that uses the {pi} mode for the lower energy part and the {pi}/2 mode cavity for the higher energy. We manufactured the accelerating tube and carried out beam acceleration tests, confirming that the electron beam was accelerated up to 950 keV.

43 PARTICLE ACCELERATORS↗

The Polarized SRF Gun Experiment

An experiment is under way to prove the feasibility of a super-conducting RF gun for the production of polarized electrons. We report on the progress of the experiment and on simulations predicting the possibility of success.

43 PARTICLE ACCELERATORS↗

Optimizing Native Ion Mobility Q-TOF in Helium and Nitrogen for Very Fragile Noncovalent Structures

The amount of internal energy imparted to the ions prior to the ion mobility cell influences the ion structure and thus the collision cross section. Non-covalent complexes with few internal degrees of freedom and/or high charge densities are particularly sensitive to collisional activation. Here, we investigated the effects of virtually all tuning parameters of the Agilent 6560 IM-Q-TOF on the arrival time distributions of ubiquitin{sup 7+} and found conditions in which the native state prevails. We discuss the effects of solvent evaporation conditions in the source, of the entire pre-IM DC voltage gradient, of the funnel RF amplitudes. We also report on ubiquitin{sup 7+} conformations in different solvents, including native supercharging conditions. Collision-induced unfolding (CIU) can be conveniently provoked either behind the source capillary or in the trapping funnel. The softness of the instrumental conditions behind the mobility cell was further optimized with the DNA G-quadruplex [(dG{sub 4}T{sub 4}G{sub 4}){sub 2}·(NH{sub 4}{sup +}){sub 3}-8H]{sup 5−}, for which ion activation results in ammonia loss. To reduce the ion internal energy and obtain the intact 3-NH{sub 4}{sup +} complex, we reduce the post-IM voltage gradient, but this results in a lower IM resolving power due to increased diffusion behind the drift tube. The article describes the various trade-offs between ion activation, ion transmission, and ion mobility performance for native MS of very fragile structures. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial Distribution of the Plasma Characteristics of a Tandem Plasma Source

The study presents results from a 2D model of hydrogen discharges in a tandem type of a plasma source. Analysis of the particle and electron-energy balance outlines the pattern of the source operation: (i) discharge production in the driver governed by the mechanisms ensuring self-consistency of hydrogen discharges in regions with rf power deposition, however, here influenced by the fluxes going to the second chamber of the source, and (ii) plasma existence in the expansion volume of the source completely determined by the particle fluxes from the first chamber. The influence of varying applied power and gas pressure is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-dimensional hybrid simulation of the dc/RF combined driven capacitively coupled CF{sub 4} plasmas

We developed a one-dimensional hybrid model to simulate the dc/RF combined driven capacitively coupled plasma for CF{sub 4} discharges. The numerical results show the influence of the dc source on the plasma density distribution, ion energy distributions (IEDs), and ion angle distributions (IADs) on both RF and dc electrodes. The increase of dc voltage impels more ions with high energy to the electrode applied to the dc source, which makes the IEDs at the dc electrode shift toward higher energy and the peaks in IADs shift toward the small angle region. At the same time, it also decreases ion-energy at the RF electrode and enlarges the ion-angles which strike the RF electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, energy efficient superconducting asymmetric ERL for ultra-high fluxes of X-ray and THz

To make the light sources compact and energy efficient, an energy recovery Superconducting RF LINAC can be used. We suggest a dual-axis, asymmetric cavity instead of conventional single axis, symmetric cavity configurations to generate average electron beam currents above 1 A, while still avoiding development of the beam breakup instability (BBU). The use of an asymmetric cavity allows one to increase the start current of HOMs participating in BBU instability development, as well as to break the positive feedback, resulting in the capability of a high average current electron beam to be driven without loss through the system. In this work, the results of experimental studies of an asymmetric cavity are presented and compared with theoretical predictions. The following steps toward design of a full-scale superconducting cavity are also discussed.

43 PARTICLE ACCELERATORS↗

THE PROJECT-X INJECTOR EXPERIMENT: A NOVEL HIGH PERFORMANCE FRONT-END FOR A FUTURE HIGH POWER PROTON FACILITY AT FERMILAB

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are carrying out a program of research and development aimed at integrated systems testing of critical components comprising the front end of Project X. This program, known as the Project X Injector Experiment (PXIE), is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. PXIE is currently under construction at Fermilab and will be completed over the period FY12-17. PXIE will include an H* ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

43 PARTICLE ACCELERATORS↗

Evaluating Light Source Color Rendition using the IES TM-30-15 Method

A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors) and wavelength space (avoiding artificial increase of color rendition values by selective optimization).

color fidelity↗

The Project-X Injector Experiment: A Novel High Performance Front-End for a Future High Power Proton Facility at Fermilab

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are carrying out a program of research and development aimed at integrated systems testing of critical components comprising the front end of Project X. This program, known as the Project X Injector Experiment (PXIE), is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. PXIE is currently under construction at Fermilab and will be completed over the period FY12-17. PXIE will include an H- ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

Nagaitsev, S.↗

LLRF System for the Fermilab PIP-II Superconducting LINAC

PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of five different acceleration \(\beta\). The LLRF system for the LINAC has to provide field and resonance control for a total of 125 RF cavities.The LLRF system design is in the final design review phase and will enter the production phase next year. The PIP-II project is an international collaboration with various partner labs contributing subsystems. The LLRF system design for the PIP-II Linac is presented and the specification requirements and system performance in various stages of testing are described in this paper.

43 PARTICLE ACCELERATORS↗

DarkLight radiation backgrounds

We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-on, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW CW beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, field emission inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation.

43 PARTICLE ACCELERATORS↗