Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Probabilistic Approach to Quantifying the Contribution of Variable Generation and Transmission to System Reliability: Preprint

The increasing electrical load served by variable generation (VG), such as wind and solar energy, in the United States and many other countries has stimulated an interesting line of research to better quantify the capacity value of these resources. Methods applied traditionally to thermal units based on their average outage rates do not apply to VG because of their uncertain and non-dispatchablenature. The North American Electric Reliability Corporation's Integration of Variable Generation Task Force recently released a report that highlighted the need to develop and benchmark underlying loss-of-load expectation and related metrics that reasonably and fairly calculate the contribution to planning reserves, or capacity value, of solar and wind power. As the fraction of generation comingfrom VG becomes more significant, their estimated capacity value will have a larger impact on system planning. In this paper, we provide a method to include VG in traditional probabilistic-based adequacy methods. This method has been implemented in the Renewable Energy Probabilistic Resource Assessment tool developed at the National Renewable Energy Laboratory. Through an example based on the U.S. Western Interconnection, this method is applied to assess the effect that transmission can have on resource adequacy. We also analyze the interactions between available transmission and capacity value for VG.

14 SOLAR ENERGY↗

Unit Commitment Considering Generation Flexibility and Environmental Constraints

This paper proposes a new framework for power system unit commitment process, which incorporates the generation flexibility requirements and environmental constraints into the existing unit commitment algorithm. The generation flexibility requirements are to address the uncertainties with large amount of intermittent resources as well as with load and traditional generators, which causes real-time balancing requirements to be variable and less predictable. The proposed flexibility requirements include capacity, ramp and ramp duration for both upward and downward balancing reserves. The environmental constraints include emission allowance for fossil fuel-based generators and ecological regulations for hydro power plants. Calculation of emission rates is formulated. Unit commitment under this new framework will be critical to the economic and reliable operation of the power grid and the minimization of its negative environmental impacts, especially when high penetration levels of intermittent resources are being approached, as required by the renewable portfolio standards in many states.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Braking System of a Tidal Generator

Renewable energy generation has experienced significant cost reductions during the past decades, and it has become more accepted by the global population. In the beginning, wind generation dominated the development and deployment of renewable energy; however, during recent decades, photovoltaic (PV) generation has grown at a very significant pace due to the tremendous decrease in the cost of PV modules. The focus on renewable energy generation has now expanded to include new types with promising future applications, such as river and tidal generation. The input water flow to these types of resources is more predictable than wind or solar generation. The data used in this paper is representative of a typical river or tidal generator. The analysis is based on a generator with a power rating of 40 kW. The tidal generator under consideration is driven by two sets of helical turbines connected to each side of the generator located in between the turbines. The generator is operated in variable speed, and it is controlled to maximize the energy harvested as well as the operation of the turbine generator. The electrical system consists of a three-phase permanent magnet generator connected to a three-phase passive rectifier. The output of the rectifier is connected to a DC-DC converter to match the rectifier output to the DC bus voltage of the DC-AC inverter. The three-phase inverter is connected to the grid, and it is controlled to provide a good interface with the grid. One important aspect of river and tidal generation is the braking mechanism. In a tidal generator, the braking mechanism is important to avoid a runaway condition in case the connection to the grid is lost when there is a fault in the lines. A runaway condition may lead to an overspeed condition and cause extreme stresses on the turbine blade structure and eventual disintegration of the mechanical structure. In this paper, the concept of the dynamic braking system is developed and investigated for normal and abnormal operations. The main objective is to optimize the performance under emergency braking while designing the system to be as simple as possible to avoid overdesigning the power electronics or exceeding the target budget.

13 HYDRO ENERGY↗

Analysis of the Impacts of Distribution-Connected PV Using High-Speed Data Sets: Preprint

This paper, presented at the IEEE Green Technologies Conference 2013, utilizes information from high resolution data acquisition systems developed at the National Renewable Energy Laboratory and deployed on a high-penetration PV distribution system to analyze the variability of different electrical parameters. High-resolution solar irradiance data is also available in the same area which is used to characterize the available resource and how it affects the electrical characteristics of the study circuit. This paper takes a data-driven look at the variability caused by load and compares those results against times when significant PV production is present. Comparisons between the variability in system load and the variability of distributed PV generation are made.

14 SOLAR ENERGY↗

Index for Wind Power Variability

Variability of large scale wind power generation is dependent on several factors: characteristics of installed wind power plants, size of the area where the plants are installed, geographic dispersion within that area and its weather regime(s). Variability can be described by ramps in power generation, i.e. changes from time period to time period. Given enough data points, it can be described with a probability density function. This approach focuses on two dimensions of variability: duration of the ramp and probability distribution. This paper proposes an index based on these two dimensions to enable comparisons and characterizations of variability under different conditions. The index is tested with real, large scale wind power generation data from several countries. Considerations while forming an index are discussed, as well as the main results regarding what the drivers of variability experienced for different data.

17 WIND ENERGY↗

Process Design by FEM Simulation for Shape Ring Rolling of Large-Sized Ring

Ring rolling process is usually used to fabricate large-sized ring, such as, tower flange for wind power electric generator. Many kinds of seamless ring are used in wind power electric generator and manufactured by ring rolling process. In general, final part is machined after forming with shape of plain square section. Since interests for near net shaping of seamless ring have been increased gradually because of green energy, it is necessary to develop the technology for shape ring rolling with respect to the market demands and cost. Therefore, we studied the process and die design for shape ring rolling of large sized ring over 3,500 mm out diameter by experiment and FEM simulation. Ring rolling process is very difficult to solve by FEM method because of equilibrium state and size effect, etc. Moreover, shape ring rolling is more difficult to solve the problem that two plastic deformation zones are different each other, that is main roll and conical roll. Also since conical roll has a shape, deformation velocity field is very much complex and the deformed section passed axial roll is different section and velocity field. The FE simulations are performed to analyze process variables affected in forming of profiled ring. Therefore, the main features of used FE model are: (1) it adopts a transient or unsteady state full ring mesh to model the deformation processes and shape development; (2) the mandrel and conical rolls are modeled using coupled heat-transfer elements; (3) the model involves the full process from blank through perform to final profiled ring. From these calculated results, we have proposed the mechanisms of various tools, such as mandrel and conical roll. The calculated results are compared experimental results. Calculated results can predict the tilting of profiled ring and then process variables to form large sized ring.

36 MATERIALS SCIENCE↗

Super-Resolution for Renewable Energy Resource Data with Wind from Reanalysis Data and Application to Ukraine

With a potentially increasing share of the electricity grid relying on wind to provide generating capacity and energy, there is an expanding global need for historically accurate, spatiotemporally continuous, high-resolution wind data. Conventional downscaling methods for generating these data based on numerical weather prediction have a high computational burden and require extensive tuning for historical accuracy. In this work, we present a novel deep learning-based spatiotemporal downscaling method using generative adversarial networks (GANs) for generating historically accurate high-resolution wind resource data from the European Centre for Medium-Range Weather Forecasting Reanalysis version 5 data (ERA5). In contrast to previous approaches, which used coarsened high-resolution data as low-resolution training data, we use true low-resolution simulation outputs. We show that by training a GAN model with ERA5 as the low-resolution input and Wind Integration National Dataset Toolkit (WTK) data as the high-resolution target, we achieved results comparable in historical accuracy and spatiotemporal variability to conventional dynamical downscaling. This GAN-based downscaling method additionally reduces computational costs over dynamical downscaling by two orders of magnitude. We applied this approach to downscale 30 km, hourly ERA5 data to 2 km, 5 min wind data for January 2000 through December 2023 at multiple hub heights over Ukraine, Moldova, and part of Romania. With WTK coverage limited to North America from 2007–2013, this is a significant spatiotemporal generalization. The geographic extent centered on Ukraine was motivated by stakeholders and energy-planning needs to rebuild the Ukrainian power grid in a decentralized manner. This 24-year data record is the first member of the super-resolution for renewable energy resource data with wind from the reanalysis data dataset (Sup3rWind).

17 WIND ENERGY↗

Energy Storage Requirements for Achieving 50% Solar Photovoltaic Energy Penetration in California

We estimate the storage required to enable PV penetration up to 50% in California (with renewable penetration over 66%), and we quantify the complex relationships among storage, PV penetration, grid flexibility, and PV costs due to increased curtailment. We find that the storage needed depends strongly on the amount of other flexibility resources deployed. With very low-cost PV (three cents per kilowatt-hour) and a highly flexible electric power system, about 19 gigawatts of energy storage could enable 50% PV penetration with a marginal net PV levelized cost of energy (LCOE) comparable to the variable costs of future combined-cycle gas generators under carbon constraints. This system requires extensive use of flexible generation, transmission, demand response, and electrifying one quarter of the vehicle fleet in California with largely optimized charging. A less flexible system, or more expensive PV would require significantly greater amounts of storage. The amount of storage needed to support very large amounts of PV might fit within a least-cost framework driven by declining storage costs and reduced storage-duration needs due to high PV penetration.

14 SOLAR ENERGY↗

Energy Storage Requirements for Achieving 50% Penetration of Solar Photovoltaic Energy in California

We estimate the storage required to enable PV penetration up to 50% in California (with renewable penetration over 66%), and we quantify the complex relationships among storage, PV penetration, grid flexibility, and PV costs due to increased curtailment. We find that the storage needed depends strongly on the amount of other flexibility resources deployed. With very low-cost PV (three cents per kilowatt-hour) and a highly flexible electric power system, about 19 gigawatts of energy storage could enable 50% PV penetration with a marginal net PV levelized cost of energy (LCOE) comparable to the variable costs of future combined-cycle gas generators under carbon constraints. This system requires extensive use of flexible generation, transmission, demand response, and electrifying one quarter of the vehicle fleet in California with largely optimized charging. A less flexible system, or more expensive PV would require significantly greater amounts of storage. The amount of storage needed to support very large amounts of PV might fit within a least-cost framework driven by declining storage costs and reduced storage-duration needs due to high PV penetration.

14 SOLAR ENERGY↗

Economic Dispatch for DC-Connected Battery Systems on Large PV Plants

Falling costs of energy storage combined with an increasing need to mitigate variable generation integration issues is leading to more PV projects that include batteries. Large PV plants that include batteries face challenges optimizing the value of the power they produce, especially when the batteries are DC-coupled and otherwise clipped power (due to high DC/AC ratio) is available. Multiple charging times and sources must be considered, including: grid charging, charging from PV that would otherwise be exported to the grid, and charging from clipped PV power. Then discharge schedules must be optimized against time-of-day pricing. The National Renewable Energy Laboratory in partnership with Southern Company has developed a heuristic algorithm in the System Advisor Model (SAM) which strategically charges the battery from PV and discharges the battery depending on the time-of-day prices of the PPA, the forecast PV production, and the estimated wear cost of the battery. The algorithm and case study results from a generic plant will be presented with recommendations for future work.

25 ENERGY STORAGE↗

Investigating the Correlation Between Wind and Solar Power Forecast Errors in the Western Interconnection: Preprint

Wind and solar power generations differ from conventional energy generation because of the variable and uncertain nature of their power output. This variability and uncertainty can have significant impacts on grid operations. Thus, short-term forecasting of wind and solar generation is uniquely helpful for power system operations to balance supply and demand in an electricity system. This paper investigates the correlation between wind and solar power forecasting errors.

14 SOLAR ENERGY↗

Enhancing Distribution System Resilience: A First-Order Meta-RL Algorithm for Critical Load Restoration

The increasing frequency of extreme events and the integration of distributed energy resources (DERs) into modern grids have elevated the need for resilient and efficient critical load restoration strategies in distribution systems. However, the stochastic nature of renewable DERs, limited energy resource availability and the intricate nonlinearities inherent in complex grid control problem make the problem challenging. Although reinforcement learning (RL) and warm-start RL methods have shown promising results, their performance often falls short in rapidly adapting to new, unseen situations and typically requires exhaustive problem-specific tuning. To address these gaps, we propose a First-Order Meta-based RL (FOM-RL) algorithm within an online framework for adaptive and robust critical load restoration. By harnessing local DERs as the enabling technology, FOM-RL allows the RL agent to swiftly adapt to new unseen scenarios by leveraging previously acquired knowledge of different tasks. Experimental results provide evidence that proposed algorithm learns more efficiently and showcases generalization capabilities across diverse set of operational scenarios. Moreover, a rigorous theoretical analysis yields a tight sublinear regret bound, sensitive to temporal variability, with a task-averaged optimality gap bounded by O(VM+D*/(Tsquare root(M))). These results suggest that optimality improves with task similarity and an increased number of tasks M, reaffirming the efficacy and scalability of the proposed approach in addressing the complexities of critical load restoration in distribution systems.

complexity theory↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Design and Operation of a Sensible Heat Peaking Unit for Small Modular Reactors

Approximately 19% of the electricity produced in the United States comes from nuclear power plants. Traditionally, nuclear power plants, as well as larger coal-fired plants, operate in a baseload manner at or near steady-state for prolonged periods of time. Smaller, more maneuverable plants, such as gas-fired plants, are dispatched to match electricity supply and demand above the capacity of the baseload plants. However, air quality concerns and CO2 emission standards has made the burning of fossil fuels less desirable, despite the current low cost of natural gas. Wind and solar photovoltaic (PV) power generation are attractive options due to their lack of carbon footprint and falling capital costs. Yet, these renewable energy sources suffer from inherent intermittency. This inherent intermittency can strain electric grids, forcing carbon-based and nuclear sources of energy to operate in a load follow mode. For nuclear reactors, load follow operation can be undesirable due to the associated thermal and mechanical stresses placed on the fuel and other reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid variability caused by daily load demand changes and renewable intermittency. Our previous research has shown that coupling a sensible heat TES system to a Small Modular Reactor (SMR) allows the reactor to run at effectively nominal full power during periods of variable electric demand by bypassing steam to the TES system during periods of excess capacity. In this study we demonstrate that this stored thermal energy can be recovered, allowing the TES system to act as a peaking unit during periods of high electric demand, or used to produce steam for ancillary applications such as desalination. For both applications the reactor is capable of operating continuously at approximately 100% power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Climate Database (NCDB)

The National Climate Database (NCDB) is a high resolution, bias-corrected climate dataset consisting of the three most widely used variables of solar radiation- global horizontal (GHI), direct normal (DNI), and diffuse horizontal irradiance (DHI)- as well as other meteorological data. The goal of the NCDB is to provide unbiased high temporal and spatial resolution climate data needed for renewable energy modeling. The NCDB is modeled using a statistical downscaling approach with Regional Climate Model (RCM)-based climate projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX; linked below). Daily climate projections simulated by the Canadian Regional Climate Model 4 (CanRCM4) forced by the second-generation Canadian Earth System Model (CanESM2) for two Representative Concentration Pathways (RCP4.5 or moderate emissions scenario and RCP8.5 or highest baseline emission scenario) are selected as inputs to the statistical downscaling models. The National Solar Radiation Database (NSRDB) is used to build and calibrate statistical models.

Array↗

A review of tidal energy—Resource, feedbacks, and environmental interactions

The ocean contains a variety of renewable energy resources, little of which has been exploited. Here, we review both tidal range and tidal stream energy, with a focus on the resource, feedbacks, and environmental interactions. The review covers a wide range of timescales of relevance to tidal energy, from fortnightly (spring-neap) and semi-diurnal variability, down to array, and device-scale turbulence. When simulating the regional tidal energy resource, and to assess environmental impacts, it is necessary to account for feedbacks between the tidal array and the resource itself. We critically review various methods for simulating energy extraction, from insights gained through theoretical studies of “tidal fences” in idealized channels, to realistic three-dimensional model studies with complex geometry and arrays of turbines represented by momentum sinks and additional turbulence due to the presence of rotors and support structures. We discuss how variability can be reduced by developing multiple (aggregated) sites with a consideration of the enhanced phase diversity offered by exploiting less energetic tidal currents. This leads to future research questions that have not yet been explored in depth at first-generation tidal sites in relatively sheltered channels (e.g., the interaction of waves with currents). Such enhanced understanding of real sea conditions, including the effects of wind and waves, leads to our other identified primary future research direction—reduced uncertainties in turbulence predictions, including the development of realistic models that simulate the interaction between ambient turbulence and the turbulence resulting from multiple wakes, and changes to system-wide hydrodynamics, water quality, and sedimentation.

Environmental impacts↗

The National Solar Radiation Database (NSRDB) Fiscal Years 2019-2021(Final Report)

The National Solar Radiation Database (NSRDB) is the leading public source of high-resolution solar resource data in the United States, with more than 166,000 users annually. This database represents the state of the art in satellite-based estimation of solar resource information and uses a unique physics-based modeling approach that enables improvements in accuracy with the deployment of the next-generation geostationary satellites. Making the highest quality, state-of-the-art, regularly updated data sets available on a timely basis for users reduces costs of solar deployment by providing accurate information for siting studies and system output prediction, and thereby reduces levelized cost of energy. Also, high-resolution information from the NSRDB enables moving beyond levelized cost of energy when valuing the impact of renewables on the grid. Additionally, the NSRDB enables the integration of large amounts of solar on the grid by providing critical information about solar availability and variability that is used to enhance grid reliability and power quality.

14 SOLAR ENERGY↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗