Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The Distributed Energy Resource Risk Manager

Organizations need a comprehensive approach to managing security and privacy risks, especially for energy resources that are becoming increasingly distributed. A tool by the National Renewable Energy Laboratory (NREL) makes it possible to manage these risks and maintain the highest standards of cybersecurity. To simplify risk management for facilities and distributed energy resources, NREL has created the Distributed Energy Resource Risk Manager, an automated, user-friendly tool that helps navigate and implement one of the most widely trusted frameworks for information security, the National Institute of Standards and Technology Risk Management Framework.

compliance↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report

The Department of Energy is interested in technologies that support the sustainable production of fuels, chemicals, and other bioproducts from plant biomass, to offset the nation’s reliance on fossil resources. The plant cell wall of energy crops provides the largest reservoir of raw materials for bioproducts. However, the widespread use of plant cell walls is hampered by their complexity and resistance to breakdown. To improve the productivity and cost-effectiveness of using energy crops to generate bioproducts, the fundamental problem of deconstructing plant cell walls must be addressed. This project developed and evaluated an innovative genetic modification technology to produce strategically designed enzymes that specifically accumulate in the plant cell wall. The resulting enzyme-engineered energy crops are expected to grow normally under natural conditions but break down more quickly and easily under high temperature during the production of biobased products. As such, this plant cell wall targeting enzyme engineering effort will reduce the cost of plant cell wall deconstruction and ultimately improve the economics of bioproducts. The overall objective of this project is to develop and evaluate the in-planta enzyme engineering technology to reduce lignocellulose deconstruction cost. The concept was first validated using tobacco plant, a model plant system that is typically used in lab testing for initial concept validation. Then the enzyme optimization was validated using switchgrass, the energy crop to be used to produce bioproducts. There are three specific objectives in this Phase I project: (1) validate the enzyme optimization concept using tobacco plant, a model plant system. (2) validate the enzyme optimization concept using switchgrass. (3) techno-economic analysis (TEA) for further scale-up application. By the end of this project, in-planta enzyme engineering was validated in both tobacco and switchgrass plants, with improved enzyme activity and saccharification efficiency. The in-planta enzyme engineering in Tabacco didn’t have a significant impact on plant growth and development. Transgenic tobacco plants with in-planta cellulose degrading enzymes showed higher biomass digestibility than wild type. Gene construction and transformation in switchgrass was much longer than expected, which delayed the research progress. Besides, in-planta engineering of lignin degrading enzyme is more challenging than cellulose degrading enzyme, in terms of expression detection. Expression of lignin degrading enzyme and cellulose degrading enzyme improved biomass yield and saccharification efficiency of switchgrass, respectively. It is promising to express both genes in switchgrass for optimized overall performance. According to the results of TEA, switchgrass biomass production cost is mainly attributed to by fertility and harvesting. Biomass production profit can increase up to 10-fold depending on biomass price. The PHA production profit is also sensitive to the biomass price. The proposed technology could potentially reduce the biomass deconstruction cost from 33% to 9% of PHA revenue, making the biomass-based PHA competitive to petroleum-based polymers even in case of relatively high biomass price of biomass. Therefore, cultivation of the genetically engineered self-deconstruction switchgrass for Polyhydroxyalkanoate (PHA) production could benefit switchgrass grower and PHA producer with attractive profits for both sectors. This new enzyme optimization approach will be beneficial for bioindustries that use energy crops as feedstocks. It will improve the economic viability of converting energy crops to renewable products that support a sustainable society and helps address the Nation’s long-term strategic needs for renewable products and reduction of reliance on fossil resources.

42 ENGINEERING↗

Sunsetting coal power in China

Reducing CO 2 emissions from coal-fired electricity generation in China is critical to limit global warming. Long-term projections of China's electricity supply tend to assume that coal generation will be a mainstay of China's electricity system through 2050, due to limitations in the scalability of hydropower, nuclear, and natural gas generation and the commercial availability of carbon capture and storage. This paper examines the resource, economic, and institutional implications of reducing and replacing coal generation in China with mostly renewable energy and energy storage by 2040. We find that the scale of solar, wind, and storage resources needed to do so is on the order of 100–150 GW/year of solar and wind capacity and 15 GW/year of energy storage from 2020 to 2025, growing to 250 GW/year and 90 GW/year, respectively, from 2025 to 2040. We then also evaluate the sensitivities if coal plants are retired by 2050.

01 COAL, LIGNITE, AND PEAT↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

Robust trajectory-constrained frequency control for microgrids considering model linearization error

Grid supportive modes integrated within inverter-based resources can improve the frequency response of renewable-rich microgrids. The synthesis of grid supportive modes to guarantee frequency trajectory constraints under a predefined disturbance set is challenging but essential. To tackle this challenge, a numerical optimal control (NOC)-based control synthesis methodology is proposed. Without loss of generality, a wind-diesel fed microgrid is studied, where we aim to design grid supportive functions in the wind turbine. In the control design, linearized models are used, and the linearization-induced errors are quantitatively analyzed by reachability and interval arithmetics and represented in the form of interval uncertainties. Then, the NOC problem can be formulated into a robust mixed-integer linear program. The control structure is strategically configured into two levels to realize online deployment. The proposed control is verified on the modified 33-node microgrid with a full-order three-phase nonlinear model in Simulink. In conclusion, the simulation results show the effectiveness of the proposed control paradigm and the necessity of considering linearization-induced uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Performance Variables to Accelerate the Deployment of Sustainable Aviation Fuels at a Regional Scale

An increase in jet fuel consumption and its associated emissions across the world have led to the need for alternative technologies to produce sustainable aviation fuels (SAF). One option to produce SAFs is to utilize waste or biomass-based feedstocks that has the potential to reduce greenhouse gas emissions by 50% or more compared to conventional jet fuel. However, there is a lack of understanding of how the synergistic effects of key performance variables could hinder or help the deployment of aviation fuels on a regional scale. Here, we assess the implications of key variables-including type and quantity of waste/biomass feedstock availability near the airport, cost of SAF production, life cycle greenhouse gas (GHG) emissions, policies, and fuel/infrastructure logistics-on the deployment of SAF at Chicago's O'Hare International Airport. We consider three ASTM International-approved SAF technologies (Hydroprocessed Esters and Fatty Acids, Fischer-Tropsch, and Alcohol to Jet) that can be blended up to 50% with petroleum-based jet fuel. Results from our analysis show that woody biomass-based Fischer-Tropsch technology has the lowest fuel production costs ($2.31-$2.81/gallon gasoline equivalent) of all pathways, and it reduces life cycle GHG emissions by 86% compared to conventional jet fuel despite the higher availability of crop residues compared to either woody biomass or fats, oils, and greases. Also, infrastructure is available at O'Hare International Airport to blend SAF with Jet A fuel through three terminals directly connected to the airport via pipelines. Our sensitivity analysis shows renewable fuel incentives and feedstock price to be key performance variables affecting the production cost and deployment of SAF.

alcohol-to-jet↗

Characterization of solid particle candidates for application in thermal energy storage and concentrating solar power systems

Thermal energy storage (TES) enables concentrating solar power to remain competitive in the renewable energy mix by firming up intermittent solar resource and providing grid services such as load shifting. Free from siting constraints, stand-alone TES systems show promise as a low-cost alternative to traditional pumped-storage hydropower or compressed air energy storage. At the core of all TES technologies is a storage medium, the selection of which governs many aspects of system design and operation. Although the majority of commercial installations utilize molten salts, solid particles can demonstrate stability over wider temperature ranges. This amounts to increased energy storage densities and corresponding reductions in system cost which is essential in achieving low-cost energy storage. In this work, eight solid particle candidates are systematically identified and screened for application in a specific particle-TES system. The five most promising candidates (CARBO CP and HSP, calcined flint clay (CFC), brown fused alumina (BFA), and silica sand) are further characterized by size and morphology for fluidization suitability, flowability for particle transport, and thermal stability. Calcined flint clay and brown fused alumina are eventually down-selected due to thermal instability at the target operational temperature of 1200 °C. Although the physical characteristics of CARBO outperform silica sand in all categories examined, the marginal performance gains are considered insufficient to justify the additional media cost so silica sand is selected as the leading candidate. Within the silica sand (α-quartz) space, the high end of Geldart Group B particles is identified to satisfy the target fluidization regime for the application of interest without compromising particle flowability. Here, in focused testing, Silica 460 is shown to exhibit sufficient stability through long-duration (500-hour) thermal and cyclic testing (1200 °C), 10-hour testing at 1400 °C, and in contact with candidate refractory containment materials. Finally, an average heat capacity of 1.1 J/g∙ °C is measured over 300-1200 °C with a quartz inversion enthalpy (ΔH α-β ) of 10.7J/g.

14 SOLAR ENERGY↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Near-Critical CO 2 -Assisted Liquefaction-Extraction of Biomass and Wastes to Fuels and Value-Added Products

With the growing need for sustainable carbon-neutral liquid fuels, low-grade feedstocks, such as lignocellulosic biomass, and municipal solid wastes offer sufficient potential via thermochemical conversion. But the existing thermochemical means are limited in feed flexibility and scalability and require significant processing (energy and costs) of the intermediates. Bio-oil/biocrude intermediate from fast pyrolysis and hydrothermal techniques is impeded by issues of stability and oxygen content, along with hydrotreating viability. To address these issues, we investigated a novel pathway of near-critical CO 2 -assisted integrated liquefaction-extraction (NILE) technology in conceptual aspects for conversion of various biomass and municipal solid wastes into high-quality biocrude with high compatibility for co-hydrotreating with traditional fossil crude for liquid fuel needs in power and transportation sectors. Using supercritical CO 2 for dewatering wet feedstocks, for liquefaction, and extraction for lighter biocrude has produced biocrude with lower oxygen content by 50%, lowered metal content by 90%, stable viscosity, low acidity, and good aging stability compared to that produced from hydrothermal liquefaction along with higher hydrotreating and co-hydrotreating compatibility. Hydrotreating of the biocrude extract from supercritical CO 2 extraction also was feasible with no detected coke deposition, an oxygen content of 1%, and catalyst deactivation. Here, the validation and capabilities of the NILE concept urge for its further development to obtain sustainable liquid fuels with lower greenhouse gas emissions and costs.

09 BIOMASS FUELS↗

Shallow EGS Regional Resource Potential and Map - Snake River Plain

SMU Geothermal Lab developed a methodology to estimate shallow (1 km to 4 km) Enhanced Geothermal Systems (EGS) resource potential using an approach that utilizes recent geology and geophysical research along with new well data to improve the thermal conductivity model, mitigate impacts from groundwater flow in the thermal model, and examine radioactivity data variations. By incorporating the results of the most recent projects with the SMU shallow methodology, we developed a more accurate, updated resource estimate for the Snake River Plain (SRP). The resulting maps and resource estimates can be used by the National Renewable Energy Lab (NREL), Bureau of Land Management (BLM), and the public to determine how best to move forward with future project development.

15 GEOTHERMAL ENERGY↗

Causes of and Solutions to Wind Speed Bias in NREL's 2020 Offshore Wind Resource Assessment for the California Pacific Outer Continental Shelf

This report provides the results of a detailed analysis into the causes of high wind speed bias in the 20-year wind resource data set for offshore California the National Renewable Energy Laboratory (NREL) released in 2020, herein called CA20. The data set was developed using the state-of-the-art Weather Research and Forecasting (WRF) model. Notably, no floating lidars were available at the time in offshore California to validate offshore hub-height wind speeds. In late 2020, the Pacific Northwest National Laboratory (PNNL) deployed two floating lidars in the California outer continental shelf (OCS), near the Bureau of Ocean Energy Management (BOEM) call areas of Humboldt and Morro Bay. Using these observations through 2021, NREL found considerable bias in modeled hub-height winds at both locations: up to +2 m/s at Humboldt over a 6-month period, and up to +1 m/s at Morro Bay over a one-year period. Upon the discovery of this bias, the Department of Energy (DOE) and BOEM funded NREL and PNNL to investigate the causes of, impacts of, and solutions to the bias in the CA20 data set. This report summarizes the findings of this research. We first investigated whether different WRF model setups could lead to reduced bias. We found that the choice of planetary boundary layer (PBL) scheme - which controls the vertical turbulent mixing of momentum, heat, and moisture in the lowermost part of the atmosphere - greatly affected hub-height wind speeds in the region. Specifically, switching from the Mellor-Yamada-Nakanishi-Niino (MYNN) scheme used in CA20 (and widely used across a range of operational and research weather models) to the less common Yonsei University (YSU) scheme nearly eliminated the bias at both the Humboldt and Morro Bay lidar locations. The large discrepancy between the MYNN- and YSU-modeled hub-height winds pointed towards the role of atmospheric stability. In general, PBL schemes agree well in conditions of high turbulence and mixing, normally referred to as "unstable" conditions. By contrast, PBL schemes start to diverge in "stable" conditions, where turbulence is low and thermal stratification (i.e., higher temperature air sitting on top of colder air) greatly suppresses vertical mixing. Under such conditions, winds aloft can decouple from surface effects and greatly accelerate, causing high wind speeds at hub-height and frequent low-level jets (LLJs). We determined that these stable conditions are in fact dominant in offshore California. The region is characterized by moderate-to-extreme stable stratification with a LLJ on average around 200 meters above sea-level. To our knowledge, no wind energy area globally has as strongly stable stratification as offshore California. Under these extreme conditions, we determined that the MYNN scheme models higher stability than YSU, resulting in less vertical turbulent mixing than YSU, allowing for the acceleration of hub-height winds, more intense LLJs, and higher-amplitude inertial oscillations. Using surface observations, we found that MYNN overestimates near-surface stability, whereas YSU tends to model stability better. We then considered several short-term case studies to assess additional meteorological drivers of the bias at Humboldt. We found that during synoptic scale northerly flows driven by the North Pacific High and inland thermal low, a coastal warm bias in the MYNN case studies contributes to the modeled wind speed bias by altering the boundary layer thermodynamics via a thermal wind mechanism. Given the strong performance of the YSU-based runs in offshore California, NREL has produced and published an updated version of the CA20 data set with YSU as the PBL scheme. This updated data set is now part of NREL's 2023 National Offshore Wind (NOW-23) data set, which covers all the U.S. offshore waters. The development and final validation of the NOW-23 data set in offshore California is documented in this report.

17 WIND ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗