Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Plans and Status of Wind-Tunnel Testing Employing an Aeroservoelastic Semispan Model

This paper presents the research objectives, summarizes the pre-wind-tunnel-test experimental results to date, summarizes the analytical predictions to date, and outlines the wind-tunnel-test plans for an aeroservoelastic semispan wind-tunnel model. The model is referred to as the Supersonic Semispan Transport (S4T) Active Controls Testbed (ACT) and is based on a supersonic cruise configuration. The model has three hydraulically-actuated surfaces (all-movable horizontal tail, all-movable ride control vane, and aileron) for active controls. The model is instrumented with accelerometers, unsteady pressure transducers, and strain gages and will be mounted on a 5-component sidewall balance. The model will be tested twice in the Langley Transonic Dynamics Tunnel (TDT). The first entry will be an "open-loop" model-characterization test; the second entry will be a "closed-loop" test during which active flutter suppression, gust load alleviation and ride quality control experiments will be conducted.

Perry, Boyd, III↗

A dataset of cyber-induced mechanical faults on buildings with network and buildings data

We have collected data of cyber-induced mechanical faults on buildings using a simulation platform. A DOE reference building model was used for running the simulation under a Rogue device attack and collected the network data as well as the physical buildings data to better understand the impacts of cyber attacks on the building and help identify the source of the mechanical fault with the network data. Alfalfa is the tool used for simulating the DOE reference buildings and acts as an interface to the model for querying the status and providing input externally. The Building Automation System (BAS) is the centralized controller providing control commands to other BACnet devices on the network based on the building status received from Alfalfa. The BACnet devices like damper will listen for the control commands from BAS on the BACnet network and implement it. The attacker is the malicious actor on the network creating disruptions by placing cyber-attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First-principles modeling of chemistry in mixed solvents: Where to go from here?

Mixed solvents (i.e., binary or higher order mixtures of ionic or nonionic liquids) play crucial roles in chemical syntheses, separations, and electrochemical devices because they can be tuned for specific reactions and applications. Apart from fully explicit solvation treatments that can be difficult to parameterize or computationally expensive, there is currently no well-established first-principles regimen for reliably modeling atomic-scale chemistry in mixed solvent environments. We offer our perspective on how this process could be achieved in the near future as mixed solvent systems become more explored using theoretical and computational chemistry. We first outline what makes mixed solvent systems far more complex compared to single-component solvents. An overview of current and promising techniques for modeling mixed solvent environments is provided. We focus on so-called hybrid solvation treatments such as the conductor-like screening model for real solvents and the reference interaction site model, which are far less computationally demanding than explicit simulations. We also propose that cluster-continuum approaches rooted in physically rigorous quasi-chemical theory provide a robust, yet practical, route for studying chemical processes in mixed solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced El NiñO Variability in the Mid-Pliocene According to the Pliomip2 Ensemble

The mid-Pliocene warm period (3.264–3.025 Ma) is the most recent geological period during which atmospheric CO 2 levels were similar to recent historical values (∼400 ppm). Several proxy reconstructions for the mid-Pliocene show highly reduced zonal sea surface temperature (SST) gradients in the tropical Pacific Ocean, indicating an El Niño-like mean state. However, past modelling studies do not show these highly reduced gradients. Efforts to understand mid-Pliocene climate dynamics have led to the Pliocene Model Intercomparison Project (PlioMIP). Results from the first phase (PlioMIP1) showed clear El Niño variability (albeit significantly reduced) and did not show the greatly reduced time-mean zonal SST gradient suggested by some of the proxies. In this work, we study El Niño–Southern Oscillation (ENSO) variability in the PlioMIP2 ensemble, which consists of additional global coupled climate models and updated boundary conditions compared to PlioMIP1. We quantify ENSO amplitude, period, spatial structure and “flavour”, as well as the tropical Pacific annual mean state in mid-Pliocene and pre-industrial simulations. Results show a reduced ENSO amplitude in the model-ensemble mean (−24 %) with respect to the pre-industrial, with 15 out of 17 individual models showing such a reduction. Furthermore, the spectral power of this variability considerably decreases in the 3–4-year band. The spatial structure of the dominant empirical orthogonal function shows no particular change in the patterns of tropical Pacific variability in the model-ensemble mean, compared to the pre-industrial. Although the time-mean zonal SST gradient in the equatorial Pacific decreases for 14 out of 17 models (0.2 ∘C reduction in the ensemble mean), there does not seem to be a correlation with the decrease in ENSO amplitude. The models showing the most “El Niño-like” mean state changes show a similar ENSO amplitude to that in the pre-industrial reference, while models showing more “La Niña-like” mean state changes generally show a large reduction in ENSO variability. The PlioMIP2 results show a reasonable agreement with both time-mean proxies indicating a reduced zonal SST gradient and reconstructions indicating a reduced, or similar, ENSO variability.

mid-Pliocene warm period↗

Initial development of viscoplastic constitutive model of Alloy 800H in support of the use of inelastic analysis methods for ASME Section III, Division 5, Class A applications

This report describes the development of a preliminary inelastic constitutive model for the thermomechanical behavior of Alloy 800H. The objective is to develop a model suitable for incorporating into Nonmandatory Appendix Z to Section III, Division 5 of the ASME Boiler & Pressure Vessel Code, which provides guidance and reference constitutive models for the ASME design by inelastic analysis rules for Class A components. The report describes the process of collecting experimental data, developing a mathematical form for the model, and training the model against the test data. The initial version of the model captures most of the relevant material deformation mechanisms, including dynamic strain aging effects. However, further development of the model form will be required to develop a final model suitable for ASME use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Power Application Developer’s Guide to the Common Information Model: An Introduction for Power Systems Engineers and Application Developers – CIM17v40

A key issue in creating the next generation of energy management system (EMS) and advanced distribution management system (ADMS) platforms will be the ability to represent and exchange power system network model data in a consistent manner. To this end, the Common Information Model (CIM) stands out as the only standardized vocabulary (or ontology) for defining power system network models and asset data in a comprehensive, consistent manner across the generation-transmission-distribution boundary. The CIM is freely available to use and extend. The CIM is maintained by the UCAiug (informally known as the CIM User’s Group) under an Apache 2.0 license. The CIM Users Group collaborates with the IEC and other standards communities for the development of technical and informative specifications. Although portions of the information model are referred to by the corresponding IEC standards naming, it is not necessary to purchase any of the IEC standards to use the CIM information model. This document provides a roadmap for power system engineers and application developers not familiar with semantic modeling to start using the CIM for modeling, simulation, optimization, and development of advanced power applications. The key classes needed for defining power system topology and equipment are explained systematically. Key focus areas include modeling of lines, transformers, generators, switching equipment, loads, and distributed energy resources (DERs).

97 MATHEMATICS AND COMPUTING↗

Cosmic rays near the heliospheric current sheet. II - An ensemble approach to comparing theory and observation

A quantitative comparison is carried out between theoretical predictions and observations of the intensity of galactic cosmic rays near the interplanetary current sheet. Model calculations are compared with a statistical analysis of observations of galactic cosmic rays at the earth and the simultaneous position of the current sheet. Since the observations were made over a period of several years, the inclination of the current sheet varied considerably, and comparison with any one model calculation referring to a given inclination would not be appropriate. An ensemble of different current sheet inclinations are used to generate expected values with the model in order to make the analysis of the computations approximate the method used to analyze the data. Agreement is found between theory and observation at energies of the order of a few GeV.

Jokipii, J. R.↗

Earth GRAM-99 and Trace Constituents

Global Reference Atmospheric Model (GRAM-99) is an engineering-level model of Earth's atmosphere. It provides both mean values and perturbations for density, temperature, pressure, and winds, as well as monthly- and geographically-varying trace constituent concentrations. From 0-27 km, GRAM thermodynamics and winds are based on National Oceanic and Atmospheric Administration Global Upper Air Climatic Atlas (GUACA) climatology. Above 120 km, GRAM is based on the NASA Marshall Engineering Thermosphere (MET) model. In the intervening altitude region, GRAM is based on Middle Atmosphere Program (MAP) climatology that also forms the basis of the 1986 COSPAR International Reference Atmosphere (CIRA). Atmospheric composition is represented in GRAM by concentrations of both major and minor species. Above 120 km, MET provides concentration values for N2, O2, Ar, O, He, and H. Below 120 km, species represented also include H2O, O3, N2O, CO, CH4, and CO2. At COSPAR 2002 a comparison was made between GRAM constituents below 120 km and those provided by Naval Research Laboratory (NRL) climatology. No current need to update GRAM constituent climatology in that height range was identified. This report examines GRAM (MET) constituents between 100 and 1000 km altitudes. Discrepancies are noted between GRAM (MET) constituent number densities and mass density or molecular weight. Near 110 km altitude, there is up to about 25% discrepancy between MET number density and mass density (with mass density being valid and number densities requiring adjustment). Near 700 km altitude there is also up to about 25% discrepancy between MET number density and mean molecular weight (with molecular weight requiring adjustment). In neither case are MET mass density estimates invalidated. These discrepancies have been traced to MET subroutines SLV (which affects 90-170 km height range) and SLVH (which affects helium above 440 km altitude). With these discrepancies corrected, results are presented to illustrate GRAM (MET) constituent mole fractions in terms of height-latitude cross sections from 100 to 1000 km altitude, and latitude-longitude 'maps' at 450 km (approximate height of International Space Station). Plans are discussed for an update of MET (and GRAM) to correct these constituent inconsistencies and to incorporate several new thermospheric model features.

Justus, C. G.↗

Improvements in High Temperature Gas Cooled Reactor Modeling Capabilities in the Pronghorn Code

This report details the improvement of pebble bed reactor modeling capabilities in the Pronghorn code in fiscal year 2022. The following accomplishments are reported: Deployment of weakly compressible finite volume formulation to the HTR- PM reference plan model; Enable modeling of stagnant gas gaps in the finite volume formulation; Enable using all Pronghorn correlations available in the finite element version in the finite volume version; Modeling of decay heat in pebble bed reactors; Simplifying the input for multiphysics equilibrium core calculations and significant reduction of execution time; Implementation of advanced correlations developed by the Center of Excellence for Thermal-Fluids Applications in Nuclear Energy . In addition, this report includes a development plan for Pronghorn and associated NEAMS tools for prismatic gas-cooled reactors.

97 MATHEMATICS AND COMPUTING↗

Sample problems for Section III, Division 5 design by inelastic analysis of Grade 91 components

This report works through two sample design analyses of representative Grade 91 components using the ASME Boiler & Pressure Vessel Code Section III, Division 5, Appendix HBB-T rules for the strain and deformation and creep-fatigue design criteria using a design by inelastic analysis approach. The component geometries and loadings were selected to span a wide variety of potential applications. The sample components are an endplate geometry, which is fairly representative of typical pressure vessel construction, and a core block, representing a critical component in a heat pipe microreactor, which has a complicated geometry and complex thermal stress history. These sample problems serve several functions. First, they are complete worked examples of how to apply the current design by inelastic analysis rules. Second, they serve as test cases to evaluate the current rules and provide feedback on how they could be optimized to deal with complicated component geometries or to be better automated in modern finite element analysis software. Finally, the analysis here uses an inelastic constitutive model for Grade 91 developed by Argonne National Laboratory and proposed for inclusion in the ASME Boiler & Pressure Vessel Code Section III, Division 5 rules as a reference constitutive model. Using this constitutive model in the sample problem analyses tests the model in the context of the ASME Code rules. The final conclusions of this report are that the material model and the current Code rules are satisfactory, but that the Code rules could be optimized to simplify automation and reduce over conservatism. Future work should address the specific optimization topics discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Navstar GPS master control station's Kalman filter experience

The Navstar Global Positioning System (GPS) is a highly accurate space based navigation system providing all weather, 24 hour a day service to both military and civilian users. The system provides a Gaussian position solution with four satellites, each providing its ephemeris and clock offset with respect to GPS time. The GPS Master Clock Station (MCS) is charged with tracking each Navstar spacecraft and precisely defining the ephemeris and clock parameters for upload into the vehicle's navigation message. Briefly described here are the Navstar system and the Kalman filter estimation process used by MCS to determine, predict, and ensure quality control for each of the satellite's ephemeris and clock states. Routine performance is shown. Kalman filter reaction and response is discussed for anomalous clock behavior and trajectory perturbations. Particular attention is given to MCS efforts to improve orbital adjust modeling. The satellite out of service time due to orbital maneuvering has been reduced in the past year from four days to under twelve hours. The planning, reference trajectory model, and Kalman filter management improvements are explained.

Scardera, Michael P.↗

Control system design for the large space systems technology reference platform

Structural models and classical frequency domain control system designs were developed for the large space systems technology (LSST) reference platform which consists of a central bus structure, solar panels, and platform arms on which a variety of experiments may be mounted. It is shown that operation of multiple independently articulated payloads on a single platform presents major problems when subarc second pointing stability is required. Experiment compatibility will be an important operational consideration for systems of this type.

Edmunds, R. S.↗

Implications of new Reasoning Capabilities for Science and Security: Results from a Quick Initial Study

On Thursday, September 12 OpenAI released “a new series of models designed to spend more time thinking… they can reason through complex tasks and solve harder problems than previous models in science, coding, and math.” These models are referred to as o1-preview and o1-mini and appear to be first results of what had been a closely held project called Strawberry within OpenAI. The models are not described as successors in the earlier GPT series because they provide a qualitatively different type of capability, especially step-by-step reasoning.

97 MATHEMATICS AND COMPUTING↗

Detailed study of oxidation/wear mechanism in lox turbopump bearings

Wear of 440C angular contact ball bearings of the phase 2 high pressure oxygen turbopump (HPOTP) of the space shuttle main engine (SSME) has been studied by means of various advanced nondestructive techniques (NDT) and modeled with reference to all known material, design, and operation variables. Three modes dominating the wear scenario were found to be the adhesive/sheer peeling (ASP), oxidation, and abrasion. Bearing wear was modeled in terms of the three modes. Lacking a comprehensive theory of rolling contact wear to date, each mode is modeled after well-established theories of sliding wear, while sliding velocity and distance are related to microsliding in ball-to-ring contacts. Microsliding, stress, temperature, and other contact variables are evaluated with analytical software packages of SHABERTH(TM)/SINDA(TM) and ADORE(TM). Empirical constants for the models are derived from NIST experiments by applying the models to the NIST wear data. The bearing wear model so established precisely predicts quite well the average ball wear rate for the HPOTP bearings. The wear rate has been statistically determined for the entire population of flight and development bearings based on Rocketdyne records to date. Numerous illustrations are given.

Chase, T. J.↗

Sensitivity of C-Band Polarimetric Radar-Based Drop Size Distribution Measurements to Maximum Diameter Assumptions

The estimation of rain drop size distribution (DSD) parameters from polarimetric radar observations is accomplished by first establishing a relationship between differential reflectivity (Z(sub dr)) and the central tendency of the rain DSD such as the median volume diameter (D0). Since Z(sub dr) does not provide a direct measurement of DSD central tendency, the relationship is typically derived empirically from rain drop and radar scattering models (e.g., D0 = F[Z (sub dr)] ). Past studies have explored the general sensitivity of these models to temperature, radar wavelength, the drop shape vs. size relation, and DSD variability. Much progress has been made in recent years in measuring the drop shape and DSD variability using surface-based disdrometers, such as the 2D Video disdrometer (2DVD), and documenting their impact on polarimetric radar techniques. In addition to measuring drop shape, another advantage of the 2DVD over earlier impact type disdrometers is its ability to resolve drop diameters in excess of 5 mm. Despite this improvement, the sampling limitations of a disdrometer, including the 2DVD, make it very difficult to adequately measure the maximum drop diameter (D(sub max)) present in a typical radar resolution volume. As a result, D(sub max) must still be assumed in the drop and radar models from which D0 = F[Z(sub dr)] is derived. Since scattering resonance at C-band wavelengths begins to occur in drop diameters larger than about 5 mm, modeled C-band radar parameters, particularly Z(sub dr), can be sensitive to D(sub max) assumptions. In past C-band radar studies, a variety of D(sub max) assumptions have been made, including the actual disdrometer estimate of D(sub max) during a typical sampling period (e.g., 1-3 minutes), D(sub max) = C (where C is constant at values from 5 to 8 mm), and D(sub max) = M*D0 (where the constant multiple, M, is fixed at values ranging from 2.5 to 3.5). The overall objective of this NASA Global Precipitation Measurement Mission (GPM/PMM Science Team)-funded study is to document the sensitivity of DSD measurements, including estimates of D0, from C-band Z(sub dr) and reflectivity to this range of D(sub max) assumptions. For this study, GPM Ground Validation 2DVD's were operated under the scanning domain of the UAHuntsville ARMOR C-band dual-polarimetric radar. Approximately 7500 minutes of DSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSD's were then used as input to a T-matrix model for computation of polarimetric radar moments at C-band. All necessary model parameterizations, such as temperature, drop shape, and drop fall mode, were fixed at typically accepted values while the D(sub max) assumption was allowed to vary in sensitivity tests. By hypothesizing a DSD model with D(sub max) (fit) from which the empirical fit to D0 = F[Z(sub dr)] was derived via non-linear least squares regression and a separate reference DSD model with D(sub max) (truth), bias and standard error in D0 retrievals were estimated in the presence of Z(sub dr) measurement error and hypothesized mismatch in D(sub max) assumptions. Although the normalized standard error for D0 = F[Z(sub dr)r] can increase slightly (as much as from 11% to 16% for all 7500 DSDs) when the D(sub max) (fit) does not match D(sub max) (truth), the primary impact of uncertainty in D(sub max) is a potential increase in normalized bias error in D0 (from 0% to as much as 10% over all 7500 DSDs, depending on the extent of the mismatch between D(sub max) (fit) and D(sub max) (truth)). For DSDs characterized by large Z(sub dr) (Z(sub dr) > 1.5 to 2.0 dB), the normalized bias error for D0 estimation at C-band is sometimes unacceptably large (> 10%), again depending on the extent of the hypothesized D(sub max) mismatch. Modeled errors in D0 retrievals from Z(sub dr) at C-band are demonstrated in detail and comparedo similar modeled retrieval errors at S-band and X-band where the sensitivity to D(sub max) is expected to be less. The impact of D(sub max) assumptions to the retrieval of other DSD parameters such as Nw, the liquid water content normalized intercept parameter, are also explored. Likely implications for DSD retrievals using C-band polarimetric radar for GPM are assessed by considering current community knowledge regarding D(sub max) and quantifying the statistical distribution of Z(sub dr) from ARMOR over a large variety of meteorological conditions. Based on these results and the prevalence of C-band polarimetric radars worldwide, a call for more emphasis on constraining our observational estimate of D(sub max) within a typical radar resolution volume is made

Carey, Lawrence D.↗

Model-based predictive control of multi-zone commercial building with a lumped building modelling approach

Here this study investigates the applicability of a lumped building modeling approach to model-based predictive control (MPC) to alleviate the complex modeling process of the grey-box multi-zone building model. Based on experimental data, two building models were estimated in this study. The detailed model as a reference case and a lumped model were estimated with decentralized and conventional approaches, respectively. Then, simulations were performed with two boundary conditions, including the comfort bound and electricity cost structure. The performances of the MPC with the detailed and lumped models were analyzed compared to the feedback control. More savings was achieved with a larger comfort bound and more aggressive electricity cost structure. The savings potential of the proposed lumped model approach was not as high as that of the detailed model. However, the proposed method yields good control performance, whose savings was approximately 8.6% over that of feedback control. These results suggest that the proposed method can be used to facilitate MPC implementation in multi-zone building applications.

42 ENGINEERING↗

ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation

A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstrated in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which constitutes the core content of the metrics and diagnostics package in section 2, and a user's guide documenting the workflow/structure of the version 1.0 codes, and including step-by-step instruction for running the package in section 3.

54 ENVIRONMENTAL SCIENCES↗