Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast and efficient Sb-based type-II phototransistors integrated on silicon

Increasing the energy efficiency and reducing the footprint of on-chip photodetectors enable dense optical interconnects for emerging computational and sensing applications. While heterojunction phototransistors (HPTs) exhibit high energy efficiency and negligible excess noise factor, their gain-bandwidth product (GBP) has been inferior to that of avalanche photodiodes at low optical powers. Here, we demonstrate that utilizing type-II energy band alignment in an Sb-based HPT results in six times smaller junction capacitance per unit area and a significantly higher GBP at low optical powers. These type-II HPTs were scaled down to 2 μm in diameter and fully integrated with photonic waveguides on silicon. Thanks to their extremely low dark current and high internal gain, these devices exhibit a GBP similar to the best avalanche devices (∼270 GHz) but with one order of magnitude better energy efficiency. Their energy consumption is about 5 fJ/bit at 3.2 Gbps, with an error rate below 10−9 at −25 dBm optical power at 1550 nm. These features suggest new opportunities for creating highly efficient and compact optical receivers based on phototransistors with type-II band alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

An Environmental and Societal Analysis of the US Electrical Energy Industry Based on the Water–Energy Nexus

To meet rising energy demands, power plant operations will expand, influencing the interactions between the water–energy nexus and society. However, a major challenge is integration of social dimensions within electricity generation. To address this, we generate a baseline dataset using US public data (2014–2019) from the Energy Information Administration and US Bureau of Labor Statistics. We identify the rate of energy consumed, CO 2 , SO 2 and NO x emissions generated, and water used per MWh net electricity as well as employee wellbeing per unit MW capacity during electricity generation. Rates of energy consumption (MMBtu/MWh) decreased 4.9%, but water consumption and withdrawal (m 3 /MWh) both increased 0.93% and 0.31%, respectively. Emissions of CO 2 , SO 2 and NO x decreased 22.64%, 75% and 25% MT/MWh, respectively. Thermoelectric cooling withdrawal and consumption is led by natural gas (50.07%, 38.31%), coal (29.61%, 25.07%), and nuclear energies (13.55%, 18.99%). Electric power generation contributes 0.06 injuries–illnesses/TWh and 0.001 fatalities/TWh, of which fossil fuels contributed 70% and 15%, respectively. Fossil fuels led in average annual employment (0.02 employees/MW) with low cost salaries (USD 0.09/MW) likely due to high collective capacity, which is declining. Estimated rates in this study and framework will aid power industry transition and operational decision makers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Power Electronics and Electric Machines [Slides]

The presentation provides an overview of NREL's Advanced Power Electronics and Electric Machines (APEEM) group and its research activities. Power electronics thermal management systems for electric-drive vehicles are described and performance metrics are provided. Additionally, advanced cooling technologies developed at NREL are presented. Finally, an overview is provided for electric machine cooling, integrated drives, and thermomechanical research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Event Detection of Power Systems Based on Unequal-Interval Reduction of PMU Data and Local Outlier Factor

With the deployment of phasor measurement units (PMU) and wide area measurement system (WAMS), it is feasible to have an insight into the events occurred in power systems based on measured data. Thus, a novel data-driven algorithm based on local outlier factor (LOF) is proposed in this work to detect and locate events in power systems using reduced PMU data. First, the unequal-interval reduction method is presented to reduce the scale of PMU data in sub-stations and reconstruct it in master station of WAMS, which can relieve the burden of communication systems. Then, principle component analysis (PCA)-based similarity search method is proposed to measure the differences of operation state between any two buses. Next, LOF is presented to detect the abnormal events in power systems, and employed to determine the region of the event source. Finally, six cases from the Western electricity coordinating council (WECC) 179-bus power system, a case from the South China power system (SCPS), and a case from the Guangdong power system (GDPS) are utilized to demonstrate the effectiveness of the proposed algorithm. Overall, the results show that proposed algorithm is effective and can be applied to event detection, event location, and online monitoring, which can enhance the situation awareness ability of power system operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-loop pressure retarded osmosis draw solutions and their regeneration processes: A review

Pressure-Retarded Osmosis (PRO) is an osmotic process that has been used to harvest energy from salinity gradients using a semi permeable membrane. A comparison between open-loop PRO (OLPRO) and closed-loop PRO (CLPRO) was made regarding their performance and costs. In CLPRO, where the diluted draw solution is re-concentrated in the regeneration system to be reutilized in the process, has recently received an intensive focus as the most viable configuration for a standalone power plant. The choice of the PRO draw solution in CLPRO is crucial to garner a high osmotic pressure as the key for the feasibility of the process. Here, in this review, the draw solutions are critically evaluated in the literature in terms of energy output as well as the method of regeneration used to recirculate them. A set of practical criteria has been suggested to appraise the adequacy of the solution for CLPRO application. It was concluded that NH 3 – CO 2 theoretically can produce 170 W/m 2 of power density. Inorganic draw solutes such as NaCl can generate high power density up to 87 W/m 2 . Organic draw solutes with their remarkably low reverse salt flux (RSF) have promising potential for future application in PRO. Similarly, the regeneration systems of the diluted draw solutions have also been reviewed and discussed. How the energy consumption of the regeneration process affects the feasibility of CLPRO is explained. For the specific case of osmotic heat engines (OHEs), when the energy of the regeneration process is supplied by heat waste, the range of applicability of the heat waste in CLPRO in terms of efficiency is defined and compared to Organic Rankine Cycle (ORC). The results showed that CLPRO has better efficiency than ORC for temperatures T < 80 °C, which makes it a promising process or low-grade heat energy recovery. In addition, a PRO-RO hybrid system coupled with solar power can reduce the net specific energy consumption (SEC) to 0.39 kWh/m 3 . The conditions that regeneration processes should operate under to make PRO viable are discussed in the last section. Overall, the study indicates the key factors for optimizing the performance of CLPRO process.

42 ENGINEERING↗

Cross-cutting strategies to lower electricity use of miscellaneous electric loads in the domestic sector

Miscellaneous Electric Loads (MELs) account for roughly one quarter of building electricity use in most developed countries. A product-specific approach to lowering MELs electricity use in this category takes too long and costs too much because there are so many MELs, each providing unique services. An alternative approach focusing on key functionalities was therefore explored. These functionalities include: (1) power management, (2) power scaling, and (3) power conversion. Cross-cutting efficiency improvements to these functionalities can be incorporated into broad categories of MELs, thus saving electricity and lowering costs. Even though the population of MELs is diverse and rapidly evolving, major technical opportunities exist to improve their efficiency in these functionalities. Research into energy-saving solutions within the cross-cutting technologies will probably have larger savings than focusing on single products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Advanced Anode for Internal Reforming and Thermal Management in Solid Oxide Fuel Cells

Solid oxide fuel cell (SOFC) is an efficient and clean electrical power generation system compared to conventional combustion based technologies with energy efficiency reaching as high as 85-90% in co-generation mode (electricity and heat). Other advantages of SOFCs are hybridization, modularity of construction, small CO 2 foot print per kWh of generated electricity and fuel flexibility. Hydrocarbons present in the gaseous fuel is utilized in SOFCs by internal or external reforming. There are two different internal reforming concepts: Direct Internal Reforming (DIR) and Indirect Internal Reforming (IIR). For DIR operation, the endothermic reforming reaction and the exothermic reaction from the oxidation reaction are operated together in the single unit eliminating the requirement for a separate fuel reformer. This configuration also simplifies the overall system design, making SOFC more attractive and efficient means of producing electrical power. The main advantage of the DIR type of operation is that the H 2 or CO consumption by the electrochemical reaction could directly promote the conversion of methane at the anode side of the fuel cell resulting in high conversion and high efficiency. The DIR operation, however, requires an anode material that has desired dual catalytic (hetero and electro) properties for reforming reaction and electrochemical reactions. The anode materials also need to remain resistant to carbon formation at the operating temperature and atmosphere with stable cell performance. Another requirement is to match the reforming reactions and electrochemical reactions to avoid local cooling or overheating, which can result in mechanical failure due to thermally induced stresses. Direct internal reforming (DIR) of hydrocarbon fuels simplifies the overall SOFC system design making it more attractive and efficient for producing electrical power. Low cost alloy anodes for distributed internal reforming of methane and other hydrocarbon fuels offer increased fuel-flexibility, reliability, and long term performance stability of solid oxide fuel cells (SOFC). The research program examined modification of the chemical compositions and microstructure of high entropy alloy (HEA) anode materials using thermochemical calculations and process simulation and modeling to achieve distributed reforming over the entire anode to eliminate hot zones. Cell fabrication and testing of the HEA anodes using button cell configuration has been performed to demonstrate the advantages of new anode over traditional Ni-YSZ anodes for distributed reforming and carbon free operation. Technical accomplishments include identification and synthesis of HEA carbon-resistant anode, demonstration of reduction in reforming rate confirmed by GC and modelling data validating effectiveness for thermal management in cell/stacks, electrochemical testing of HEA anode in single cell (HEA-GDC||YSZ||LSM-YSZ) and Characterization of pretest and posttest anode materials by TEM and SEM-EDS confirming carbon-free operation.

30 DIRECT ENERGY CONVERSION↗

Analysis of degradation in residential battery energy storage systems for rate-based use-cases

This article examines the impact of residential battery energy storage (BES) systems' operational modes on the life (i.e. usable energy capacity) of the battery under several climatic conditions and battery chemistries. The sharp increase in residential BES installations has been a result of decreasing costs of batteries, increase in rate structures motivated applications such as solar self-consumption and time-of-use energy management, and customers purchasing these systems for backup power. While these different modes of operations provide a combination of increased bill savings, reliability of supply, and energy sustainability to the customer, their operational characteristics vary significantly between use-cases. Functional life of BES systems is known to be strongly dependent on their operating conditions. In this article, we analyze the operation of residential BES systems under different rate-based use-cases, for different battery chemistries and cell designs, and under different environmental conditions. This is conducted by simulating the control of BES operations using rate-based cycling algorithms and analyzing the prognosis of multiple battery lifetime models that consider complex nonlinear dependencies of operational stress factors such as state-of-charge, depth-of-discharge, and temperature on degradation. Significant variations in battery life are observed owing to the differences in characteristics of the uses-cases coupled with environmental conditions and battery chemistries. Such differences lead to the conclusion that choice of residential BES technologies and chemistries should account for their intended use-cases.

25 ENERGY STORAGE↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commonwealth of the Northern Mariana Islands: 2023 Energy Baseline Report

This report summarizes the currently available energy sector data for the Commonwealth of the Northern Mariana Islands as of December 2023. It describes primary energy consumption, end uses, energy production, relevant policies, and key challenges, including details on the electric power and transportation sectors. The report serves as a baseline of understanding to assess CNMI's island-wide energy needs and priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗