Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program (Rev. 3)

Each testing and analytical facility performing waste characterization activities for the U.S. Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) participates in the Performance Demonstration Program (PDP) to comply with the Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC) (DOE/WIPP-02-3122), the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012), and the Performance Demonstration Program Management Plan (DOE/CBFO-01-3107). The PDP serves as a quality control check for data generated in the characterization of waste destined for WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ASCEM Pumping Test Capabilities: Benchmarking and Demonstration for UGTA at U-20 WW

The Advanced Simulation Capability for Environmental Management (ASCEM) High Performance Computing (HPC) simulator, Amanzi, was improved to simulate pumping tests in confined and unconfined aquifers. This report documents the testing and then application of those capabilities to simulate the U-20 WW pumping test on Pahute Mesa. Capabilities added to Amanzi include (1) transient Darcy flow with adaptive time stepping; (2) application of the specific yield term in cells representing unconfined conditions at the water table along the top of model and specific storage at other cells; (3) source/sink term; and (4) hydraulic head boundary conditions. These capabilities are benchmarked using an analytical solution and an existing numerical code. Then, they are implemented in a set of demonstration simulations for UGTA's U-20 WW pumping test.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers

Reaction Engineering International (REI) managed a team of experts from University of Utah, Siemens Energy, Praxair, Vattenfall AB, Sandia National Laboratories, Brigham Young University (BYU) and Corrosion Management Ltd. to perform multi-scale experiments, coupled with mechanism development, process modeling and CFD modeling, for both applied and fundamental investigations. The primary objective of this program was to acquire data and develop tools to characterize and predict impacts of CO{sub 2} flue gas recycle and burner feed design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) inherent in the retrofit of existing coal-fired boilers for oxy-coal combustion. Experimental work was conducted at Sandia National Laboratories’ Entrained Flow Reactor, the University of Utah Industrial Combustion Research Facility, and Brigham Young University. Process modeling and computational fluid dynamics (CFD) modeling was performed at REI. Successful completion of the project objectives resulted in the following key deliverables: 1) Multi-scale test data from 0.1 kW bench-scale, 100 kW and 200 kW laboratory-scale, and 1 MW semi-industrial scale combustors that describe differences in flame characteristics, fouling, slagging and corrosion for coal combustion under air-firing and oxygen-firing conditions, including sensitivity to oxy-burner design and flue gas recycle composition. 2) Validated mechanisms developed from test data that describe fouling, slagging, waterwall corrosion, heat transfer, char burnout and sooting under coal oxy-combustion conditions. The mechanisms were presented in a form suitable for inclusion in CFD models or process models. 3) Principles to guide design of pilot-scale and full-scale coal oxy-firing systems and flue gas recycle configurations, such that boiler operational impacts from oxy-combustion retrofits are minimized. 4) Assessment of oxy-combustion impacts in two full-scale coal-fired utility boiler retrofits based on computational fluid dynamics (CFD) modeling of air-fired and oxygen-fired operation. This research determined that it is technically feasible to retrofit the combustion system in an air-fired boiler for oxy-fired operation. The impacts of CO{sub 2} flue gas recycle and burner design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) were minimal, with the exception of high sulfur levels resulting from untreated flue gas recycle with medium and high-sulfur coals. This work focused on combustion in the radiant and convective sections of the boiler and did not address boiler system integration issues, plant efficiencies, impacts on downstream air pollution control devices, or CO{sub 2} capture and compression. The experimental data, oxy-firing system principles and oxy-combustion process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess retrofit applications of oxy-combustion technologies to existing boilers and to guide development of new designs.

20 FOSSIL-FUELED POWER PLANTS↗

Guidelines for Datacenter Energy Information System

The purpose of this document is to provide structured guidance to data center owners, operators, and designers, to empower them with information on how to specify and procure data center energy information systems (EIS) for managing the energy utilization of their data centers. Data centers are typically energy-intensive facilities that can consume up to 100 times more energy per unit area than a standard office building (FEMP 2013). This guidance facilitates “data-driven decision making,” which will be enabled by following the approach outlined in the guide. This will bring speed, clarity, and objectivity to any energy or asset management decisions because of the ability to monitor and track an energy management project’s performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ORNL’s Envelope Stakeholder Workshop Proceedings

The 2015 Building Envelope Stakeholder Workshop hosted by Oak Ridge National Laboratory (ORNL) brought together representatives from diverse public and private entities. Presenters included senior Department of Energy (DOE) officials, ORNL personnel, and a myriad of corporate partners. To promote the use of energy-efficient technologies in commercial and residential buildings, the following issues were discussed: (1) Identifying current and anticipated barriers to the adoption of energy-efficient commercial envelope technologies; (2) Reviewing emerging and market-ready applications for new and existing commercial buildings; (3) Defining a path forward for commercial envelope products; and (5) Discussing and soliciting feedback on DOE’s strategic research road map for high-performance, moisture-managed envelope solutions for residential buildings This summary report describes key findings derived from these discussions as well as a distillation of the many discussions that unfolded during the event. It is hoped that it will be used not only to transmit this information to interested parties but also, more important, to foster continuing discussion and encourage input useful in furthering the broader goals of fostering the adoption of energy-efficient building technologies across various markets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Limiting Magnitude, τ, t eff , and Image Quality in DES Year 1

The Dark Energy Survey (DES) is an astronomical imaging survey being completed with the DECam imager on the Blanco telescope at CTIO. After each night of observing, the DES data management (DM) group performs an initial processing of that night's data, and uses the results to determine which exposures are of acceptable quality, and which need to be repeated. The primary measure by which we declare an image of acceptable quality is $\tau$, a scaling of the exposure time. This is the scale factor that needs to be applied to the open shutter time to reach the same photometric signal to noise ratio for faint point sources under a set of canonical good conditions. These conditions are defined to be seeing resulting in a PSF full width at half maximum (FWHM) of 0.9" and a pre-defined sky brightness which approximates the zenith sky brightness under fully dark conditions. Point source limiting magnitude and signal to noise should therefore vary with t in the same way they vary with exposure time. Measurements of point sources and $\tau$ in the first year of DES data confirm that they do. In the context of DES, the symbol $t_{eff}$ and the expression "effective exposure time" usually refer to the scaling factor, $\tau$, rather than the actual effective exposure time; the "effective exposure time" in this case refers to the effective duration of one second, rather than the effective duration of an exposure.

79 ASTRONOMY AND ASTROPHYSICS↗

Exascale and Beyond: Configuring, Reasoning, Scaling. Report of the 2011 Workshop on Architectures II: Exascale and Beyond, held August 8-10, Albuquerque, N.M.

The push toward exascale computing (1) and beyond is torn between contradictory and possibly incompatible goals. On the one hand, one wants a system that will be available within a short span of time, on a relatively small development budget, and with the least changes possible to the current software stack. On the other hand, one wants a system that is orders of magnitude more efficient in its energy consumption. An exascale system could be as different from current systems as scalable parallel systems were from vector machines at the time of the last major transition in the field, but the amount of application software developed at DOE in the last decades makes it undesirable to take a “clean sheet of paper” approach, if at all possible. Furthermore, one wishes to explore and develop distinct exascale architectures to reduce risk while maintaining some unity so that application codes easily port among them. Finally, the design of an exascale system may involve a large number of vendors, some of which have limited experience in the field of High-Performance Computing (HPC). A proper integration of these multiple contributions requires a proper definition of many new interfaces, as well as consistent design principles for the handling of cross-cutting issues such as resilience, performance, and power management.

97 MATHEMATICS AND COMPUTING↗

Behavioral Health/Employee Assistance Program (EAP) Report FY 15

The Sandia National Laboratories’ (SNL) Corporate Behavioral Health Program is a workplace based program that 1) assists in the early identification and resolution of personal concerns which may impact job performance, 2) assists managers and the organization in addressing productivity issues, and 3) supports the SNL commitment to provide a safe and healthful work environment. The program is offered to approximately 10,711 employees in New Mexico. The Behavioral Health Program is a corporate program combining services in NM and CA. It is integrated with other occupational health and clinical services including disability, disease management and preventive health programs. In addition, Sandia’s Behavioral Health Program interfaces with external organizations in Human Resources, the Department of Energy and Security through the Clinical Evaluation (CE) Human Reliability Program (HRP) and Workplace Violence programs. The program supports Sandia National Laboratories’ mission to safeguard national security, the environment, the public and is a proactive approach to early identification, intervention and assessment. Last, it reduces barriers to accessing mental health services and assists with reducing health care costs attributed to illness or injuries related to unhealthy lifestyles and behaviors. The EAP team is comprised of a professional staff including a licensed Clinical Psychologist who has a NM state license for psychotropic medication prescriptive authority, is board certified in Clinical Neuropsychology, and a Certified Employee Assistance Professional (CEAP), a licensed professional clinical counselor NM State Licensed (LPCC) and a licensed Marriage and Family counselor (MFT) who is also a Certified Employee Assistance Professional and who holds a doctorate in counseling psychology.

99 GENERAL AND MISCELLANEOUS↗

Behavioral Health/Employee Assistance. Interim Program Report FY 2020

The Sandia National Laboratories' (SNL) Corporate Behavioral Health Program is a workplace- based program that: 1) provides Employee Assistance Program (EAP) services including early identification and resolution of personal concerns which may impact job performance, 2) assists managers and the organization in addressing productivity issues, and 3) supports the SNL commitment to provide a safe and healthful work environment. The program is offered to approximately 13,500 employees in New Mexico. The Behavioral Health Program is a corporate program combining services in NM and CA. It is integrated with other occupational health and clinical services including disability, disease management and preventive health programs. In addition, Sandia's Behavioral Health Program provides critical management consultation and psychological assessment services for external organizations including Human Resources, the Department of Energy and Security through the Clinical Evaluation (CE) process, Human Reliability Program (HRP), Protective Force Program, Workplace Violence/Threat Assessment Team (TAT), and Insider Threat Working Group programs. The program supports Sandia National Laboratories' mission to safeguard national security, the environment, and the public; it is a proactive approach to early identification, intervention and assessment. Importantly, it reduces barriers to accessing mental health services and assists with reducing health care costs attributed to illness or injuries related to unhealthy lifestyles and behaviors. The team is comprised of a professional staff including a licensed Clinical Psychologist, a licensed professional clinical counselor (LPCC) and a licensed Marriage and Family counselor (MFT) who is also a Certified Employee Assistance Professional and who holds a doctorate in counseling psychology.

99 GENERAL AND MISCELLANEOUS↗

Sodium-Cooled Fast Reactor Proliferation Resistance and Physical Protection White Paper

The Sodium-Cooled Fast Reactor (SFR) system was identified during the Generation IV Technology Roadmap as a promising technology to perform the actinide management mission and, if enhanced economics for the system could be realized, also the electricity and heat production missions. The main characteristics of the SFR that make it especially suitable for the actinide management mission are: Consumption of transuranics in a closed fuel cycle, thus reducing the radiotoxicity and heat load which facilitates waste disposal and geologic isolation; Enhanced utilization of uranium resources through efficient management of fissile materials and multi-recycle; and, High level of safety achieved through inherent and passive means that accommodate transients and bounding events with significant safety margins.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing a Database of Bio-based Materials for Building Envelope Applications

Oak Ridge National Laboratory (ORNL) has been funded by the Department of Energy (DOE) to help accelerate the introduction of building envelope materials that would reduce the carbon footprint of the buildings sector. The DOE’s Building Technologies Office has historically sought to resolve the knowledge gaps regarding the energy efficiency and moisture durability of building envelope systems and to develop the data, guidance, and tools needed to facilitate rapid industry adoption of high-performance, moisture-managed envelope systems. This project will help accelerate the widespread acceptance of a new generation of building materials developed specifically with the intent of reducing the carbon footprint of buildings. We have produced a database of hygrothermal transport properties on low embodied carbon building materials that can be added to energy and durability simulation tools. Properties that were measured include density, heat capacity, thermal conductivity as a function of temperature and relative humidity, moisture dependent permeance, and sorption isotherms as a function of relative humidity. These data sets were measured following consensus national standards using state-of-the-art facilities. The data has been compiled and is being made available to building designers who require these data to assess these new materials in their designs. We will publish the data and seek its addition to reference databases such as the ASHRAE Handbook of Fundamentals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stack Test Summary for TA-59-0001

The Radioactive Air Emissions Management (RAEM) team performed stack flow characterization tests at Technical Area (TA) 59 Building 0001 Exhaust Stack (ES) 8. These tests were completed in accordance with Title 40 of the Code of Federal Regulations (CFR), Part 61, Subpart H and the American National Standards Institute (ANSI) N13.1-1999 required by the Clean Air Act. Subpart H of the regulation is the National Emission Standards for Hazardous Air Pollutants (NESHAP) for radionuclides, which compliance with is maintained by the REAM team.

54 ENVIRONMENTAL SCIENCES↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of BPM Electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗

Closure Report for Corrective Action Unit 139: Waste Disposal Sites, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 139 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Waste Disposal Sites' and consists of the following seven Corrective Action Sites (CASs), located in Areas 3, 4, 6, and 9 of the Nevada Test Site: CAS 03-35-01, Burn Pit; CAS 04-08-02, Waste Disposal Site; CAS 04-99-01, Contaminated Surface Debris; CAS 06-19-02, Waste Disposal Site/Burn Pit; CAS 06-19-03, Waste Disposal Trenches; CAS 09-23-01, Area 9 Gravel Gertie; and CAS 09-34-01, Underground Detection Station. Closure activities were conducted from December 2008 to April 2009 according to the FFACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 139 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls. Closure activities are summarized. CAU 139, 'Waste Disposal Sites,' consists of seven CASs in Areas 3, 4, 6, and 9 of the NTS. The closure alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 139 as documented in this CR: (1) At CAS 03-35-01, Burn Pit, soil and debris were removed and disposed as LLW, and debris was removed and disposed as sanitary waste. (2) At CAS 04-08-02, Waste Disposal Site, an administrative UR was implemented. No postings or post-closure monitoring are required. (3) At CAS 04-99-01, Contaminated Surface Debris, soil and debris were removed and disposed as LLW, and debris was removed and disposed as sanitary waste. (4) At CAS 06-19-02, Waste Disposal Site/Burn Pit, no work was performed. (5) At CAS 06-19-03, Waste Disposal Trenches, a native soil cover was installed, and a UR was implemented. (6) At CAS 09-23-01, Area 9 Gravel Gertie, a UR was implemented. (7) At CAS 09-34-01, Underground Detection Station, no work was performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Efficiency Services Sector: Workforce Education and Training Needs

This report provides a baseline assessment of the current state of energy efficiency-related education and training programs and analyzes training and education needs to support expected growth in the energy efficiency services workforce. In the last year, there has been a significant increase in funding for 'green job' training and workforce development (including energy efficiency), through the American Recovery and Reinvestment Act (ARRA). Key segments of the energy efficiency services sector (EESS) have experienced significant growth during the past several years, and this growth is projected to continue and accelerate over the next decade. In a companion study (Goldman et al. 2009), our research team estimated that the EESS will increase two- to four-fold by 2020, to 220,000 person-years of employment (PYE) (low-growth scenario) or up to 380,000 PYE (high-growth scenario), which may represent as many as 1.3 million individuals. In assessing energy efficiency workforce education and training needs, we focus on energy-efficiency services-related jobs that are required to improve the efficiency of residential and nonresidential buildings. Figure ES-1 shows the market value chain for the EESS, sub-sectors included in this study, as well as the types of market players and specific occupations. Our assessment does not include the manufacturing, wholesale, and retail distribution subsectors, or energy efficiency-focused operations and maintenance performed by facility managers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coordinated Control of Wind Turbine and Energy Storage System for Reducing Wind Power Fluctuation

This paper proposes a method for the coordinated control of a wind turbine and an energy storage system (ESS). Because wind power (WP) is highly dependent on wind speed, which is variable, severe stability problems can be caused in power systems, especially when the WP has a high penetration level. To solve this problem, many power generation corporations or grid operators have begun using ESSs. An ESS has very quick response and good performance for reducing the impact of WP fluctuation; however, its installation cost is high. Therefore, it is important to design the control algorithm by considering both the ESS capacity and WP fluctuation. Thus, we propose a control algorithm to mitigate the WP fluctuation by using the coordinated control between the wind turbine and the ESS by considering the ESS capacity and the WP fluctuation. Using de-loaded control, according to the WP fluctuation and ESS capacity, we can expand the ESS lifespan and improve grid reliability by avoiding the extreme value of state of charge (SoC) (i.e., 0 or 1 pu). The effectiveness of the proposed method was validated via MATLAB/Simulink by considering a small power system that includes both a wind turbine generator and conventional generators that react to system frequency deviation. We found that the proposed method has better performance in SoC management, thereby improving the frequency regulation by mitigating the impact of the WP fluctuation on the small power system.

17 WIND ENERGY↗

Processability and Material Behavior of NiTi Shape Memory Alloys Using Wire Laser-Directed Energy Deposition (WL-DED)

Utilizing additive manufacturing (AM) techniques with shape memory alloys (SMAs) like NiTi shows great promise for fabricating highly flexible and functionally superior 3D metallic structures. Compared to methods relying on powder feedstocks, wire-based additive manufacturing processes provide a viable alternative, addressing challenges such as chemical composition instability, material availability, higher feedstock costs, and limitations on part size while simplifying process development. This study presented a novel approach by thoroughly assessing the printability of Ni-rich Ni55.94Ti (Wt. %) SMA using the wire laser-directed energy deposition (WL-DED) technique, addressing the existing knowledge gap regarding the laser wire-feed metal additive manufacturing of NiTi alloys. For the first time, the impact of processing parameters—specifically laser power (400–1000 W) and transverse speed (300–900 mm/min)—on single-track fabrication using NiTi wires in the WL-DED process was examined. An optimal range of process parameters was determined to achieve high-quality prints with minimal defects, such as wire dripping, stubbing, and overfilling. Building upon these findings, we printed five distinct cubes, demonstrating the feasibility of producing nearly porosity-free specimens. Notably, this study investigated the effect of energy density on the printed part density, impurity pick-up, transformation temperature, and hardness of the manufactured NiTi cubes. The results from the cube study demonstrated that varying energy densities (46.66–70 J/mm3) significantly affected the quality of the deposits. Lower to intermediate energy densities achieved high relative densities (>99%) and favorable phase transformation temperatures. In contrast, higher energy densities led to instability in melt pool shape, increased porosity, and discrepancies in phase transformation temperatures. These findings highlighted the critical role of precise parameter control in achieving functional NiTi parts and offer valuable insights for advancing AM techniques in fabricating larger high-quality NiTi components. Additionally, our research highlighted important considerations for civil engineering applications, particularly in the development of seismic dampers for energy dissipation in structures, offering a promising solution for enhancing structural performance and energy management in critical infrastructure.

Dabbaghi, Hediyeh↗