Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Determination of U, V, and W from single station Doppler radar radial velocities

The ST/MST (stratosphere troposphere/mesosphere stratosphere troposphere) clear air Doppler radar, or wind profiler, is an important tool in observational meteorology because of its capability to remote observe dynamic parameters of the atmosphere. There are difficulties in transforming the observed radial velocities into meteorological wind components. How this problem has been treated in the past is reviewed, and some of the analysis is recast to a form more suited to the high diagnostic abilities of a number of fixed beam configurations with reference to a linear wind field. The results, in conjunction with other works which treats problems such as the effects of finite sample volumes in the presence of nonhomogeneous atmospheric reflectivity, have implications important to the design of both individual MST/ST radars and MST/ST radar networks. The key parameters to uncoupling terms in the scaling equations are w sub x and w sub y. Whenever the stratiform condition, which states that these two parameters are negligible, is satisfied, a five beam ST radar may determine unbiased values of u, v, and w for sample volumes directly above the radar. The divergence and partial deformation of the flow may also be determined. Three beam systems can determine w and w sub z, but are unable to obtain u and v wind components uncontaminated by vertical sheer terms, even when the stratiform condition is satisfied.

Clark, W. L.↗

Measuring the Chemical Potential of the Martian Regolith to Generate and Sustain Life

A critical component for identifying chemical biosignatures is the ability to assess in-situ the potential of an aqueous geochemical environment to generate and sustain life. On Mars or other solar bodies, in-situ chemical characterization could provide evidence as to whether the chemical composition of the regolith or evaporites in suspected ancient water bodies have been biologically influenced or possess the chemical parameters within which life may have existed, or may still exist. A variety of analytical techniques have been proposed for use in detecting and identify signatures of past or present life. These techniques fall into two groups; visual observation with instruments such as cameras or optical/atomic-force microscopes; or elemental chemical analysis with such instruments as X-ray fluorescence (XRF) and diffraction (XRD), a-proton backscatter (APX), y-ray, Mossbauer, Raman, IR, UV/VIS spectroscopies, gas chromatography (GC), or mass spectrometry (MS). Direct observation of an identifiable lifeform by the first set of instruments in a single sample is highly unlikely, especially for extinct organisms or on the surface. The later instruments can provide vital data as to the elemental mineralogy and geological history of the planet, but are highly inadequate for understanding the chemistry of the planet in terms of indigenous life or interactions with human explorers. Techniques such as XRD, XRF, and APX, provide elemental composition at high limits of detection. Some of this data can be extrapolated or interpolated to provide chemical parameters such as oxidation state or composition. Gas chromatography (GC) without standards and non-specific detectors, has little chance of identifying a mixture of unknown components. Combined with GC or by itself, mass spectrometry (MS) can provide identification of compounds, but in both cases the sample must be appropriately prepared for accurate and reliable analysis. Life as we know it, and probably identify it as such, requires an aqueous environment. Deciphering die chemical speciation of this aqueous environment is the key to recognizing therein the biosignatures of any extinct or present life forms. Identifying the soluble (ionic and nonionic) components by reacting a currently dormant environment can provide a "picture" of the thermodynamics and chemical components of a possibly bioactive environment. The only devices which can provide such information are electrochemical sensors based on the potentiometric ion selective electrodes (ISEs) and on dynamic techniques such as cyclic voltammetry (CV) and stripping voltammetry (SV). Such an array of devices can provide not only the chemical composition of a water-soluble Martian soil sample, but also several other vital chemical parameters such as pH, conductivity, redox potential, and dissolved gases. To address these issues we have been investigating the possible use of an electrochemically-based ion sensor array as a new integrated approach to quantitative analytical and chemometric electrochemical measurements. The sensor array will consist of specific and semispecific ion selective and amperometric transducers, which can simultaneously and continuously identify and semiquantitatively determine over 50 organic and inorganic analytes in water-based environments. Several individual sensors, based on the same principle, have been flight-tested and have been installed as part of the MECA instrumentation on the Mars 2001 Lander for in-situ analyses. However, the microfabrication, integration and multiplexing of such a large number of these sensors on a single substrate have not been previously attempted.

Kounaves, S. P.↗

The XRD Amorphous Component in John Klein Drill Fines at Yellowknife Bay, Gale Crater, Mars

Drill fines of mudstone (targets John Klein and Cumberland) from the Sheepbed unit at Yel-lowknife Bay were analyzed by MSL payload elements including the Chemistry and Mineralogy (CheMin), APXS (Alpha Particle X-Ray Spectrometer), and Sample Analysis at Mars (SAM) instruments. CheMin XRD results show a variety of crystalline phases including feldspar, pyroxene, olivine, oxides, oxyhydroxides, sulfates, sulfides, a tri-octahedral smectite, and XRD amorphous material. The drill fines are distinctly different from corresponding analyses of the global soil (target Rocknest) in that the mudstone samples contained detectable phyllosilicate. Here we focus on John Klein and combine CheMin and APXS data to calculate the chemical composition and concentration of the amorphous component. The chemical composition of the amorphous plus smectite component for John Klein was calculated by subtracting the abundance-weighted chemical composition of the individual XRD crystalline components from the bulk composition of John Kline as measured by APXS. The chemical composition of individual crystalline components was determined either by stoichiometry (e.g., hematite and magnetite) or from their unit cell parameters (e.g., feldspar, olivine, and pyroxene). The chemical composition of the amorphous + smectite component (approx 71 wt.% of bulk sample) and bulk chemical composition are similar. In order to calculate the chemical composition of the amorphous component, a chemical composition for the tri-octahedral smectite must be assumed. We selected two tri-octahedral smectites with very different MgO/(FeO + Fe2O3) ratios (34 and 1.3 for SapCa1 and Griffithite, respectively). Relative to bulk sample, the concentration of amorphous and smectite components are 40 and 29 wt.% for SapCa1 and 33 and 36 wt.% for Griffithite. The amount of smectite was calculated by requiring the MgO concentration to be approx 0 wt.% in the amorphous component. Griffithite is the preferred smectite because the position of its 021 diffraction peak is similar to that reported for John Klein. In both cases, the amorphous component has low SiO2 and MgO and high FeO + Fe2O3, P2O5, and SO3 concentrations relative to bulk sample. The chemical composition of the bulk drill fines and XRD crystalline, smectite, and amorphous components implies alteration of an initially basaltic material under near neutral conditions (not acid sulfate), with the sulfate incorporated later as veins of CaSO4 injected into the mudstone.

Morris, Richard V.↗

The Dark Energy Survey Supernova Programme: Modelling Selection Efficiency and Observed Core-collapse Supernova Contamination

The analysis of current and future cosmological surveys of Type Ia supernovae (SNe Ia) at high redshift depends on the accuratephotometric classification of the SN events detected. Generating realistic simulations of photometric SN surveys constitutes anessential step for training and testing photometric classification algorithms, and for correcting biases introduced by selectioneffects and contamination arising from core-collapse SNe in the photometric SN Ia samples. We use published SN time-seriesspectrophotometric templates, rates, luminosity functions, and empirical relationships between SNe and their host galaxies toconstruct a framework for simulating photometric SN surveys. We present this framework in the context of the Dark EnergySurvey (DES) 5-yr photometric SN sample, comparing our simulations of DES with the observed DES transient populations.We demonstrate excellent agreement in many distributions, including Hubble residuals, between our simulations and data.We estimate the core collapse fraction expected in the DES SN sample after selection requirements are applied and beforephotometric classification. After testing different modelling choices and astrophysical assumptions underlying our simulation,we find that the predicted contamination varies from 7.2 to 11.7 per cent, with an average of 8.8 per cent and an r.m.s. of 1.1 percent. Our simulations are the first to reproduce the observed photometric SN and host galaxy properties in high-redshift surveyswithout fine-tuning the input parameters. The simulation methods presented here will be a critical component of the cosmologyanalysis of the DES photometric SN Ia sample: correcting for biases arising from contamination, and evaluating the associatedsystematic uncertainty.

M Vincenzi↗

Estimating Cosmic Ray Spectral Parameters From Simulated Detector Responses With Detector Design Implications

A simple power law model consisting of a single spectral index alpha (sub 1), is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy E(sub k) to a steeper spectral index alpha(sub 2) greater than alpha(sub 1) above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Direct Observation of Controlled Melting and Resolidification of Succinonitrile Mixtures in a Microgravity Environment

In support of the Pore Formation and Mobility Investigation (PFMI) direct observation of experiments on the controlled melting and subsequent resolidification of succinonitrile were conducted in the glovebox facility (GBX) of the International Space Station (ISS). Samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with pure succinonitrile (SCN) and SCN-Water mixtures under 450 millibar of nitrogen. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. Sample temperatures are monitored by six in situ thermocouples. Real time visualization during melt back revealed bubbles of different sizes initiating at the solid/liquid interface, their release, interactions, and movement into the temperature field ahead of them. Subsequent re-solidification examined planar interface breakdown and the transition to steady-state dendritic growth. A preliminary analysis of the observed phenomena and its implication to future microgravity experiments is presented and discussed.

Grugel, R. N.↗

Development of Ion Mobility Spectrometry for Exobiology Flight Experiments

Ion Mobility Spectrometry (IMS) can provide gas chromatography with sample identification independent of sample retention time, with minimal interface. Initial commercial methods of IMS however, did not possess sufficient analytical capabilities and presented operational parameters which were unsuitable for exobiology missions. Subsequent development of IMS technology, with the focus on exobiology analytical requirements and mission imposed operational limitations, has produced an IMS interfaced with a GC capable of fulfilling the analytical requirements of several exobiology missions. Future exobiology missions will require further development of the IMS, particularly in the areas of overall instrument miniaturization and complex sample identification. The evolution of the exobiology focused IMS will be presented up to the current prototype design, which is a component of several proposed exobiology instruments. Areas of future development will also be discussed.

Kojiro, Daniel R.↗

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗

A three-parameter asteroid taxonomy

Broadband U, V, and x photometry together with IRAS asteroid albedos have been used to construct an asteroid classification system. The system is based on three parameters (U-V and v-x color indices and visual geometric albedo), and it is able to place 96 percent of the present sample of 357 asteroids into 11 taxonomic classes. It is noted that all but one of these classes are analogous to those previously found using other classification schemes. The algorithm is shown to account for the observational uncertainties in each of the classification parameters.

Tedesco, Edward F.↗

An NMR study of microvoids in polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally be found naturally in polymer or in NMR probe materials. There are two NMR active xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb the Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe(129)-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts line Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A single Xe-129 line at 83.003498 Mhz (with protons at 300 Mhz) was observed for the gas. With the xenon charged PMR-15 samples, a second broader line is observed 190 ppm downfield from the gas line (also observed). The width of the NMR line from the Xe-129 absorbed in the polymer is at least partially due to the distribution of microvoid sizes. From the chemical shift (relative to the gas line) and the line width, we estimate the average void sizes to be 2.74 +/- 0.20 angstroms. Since Xe-129 has such a large chemical shift range (approximately 5000 ppm), we expect the chemical shift anisotropy to contribute to the line width (delta upsilon = 2.5 kHz).

Toy, James↗

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard↗

Estimating Cosmic-Ray Spectral Parameters from Simulated Detector Responses with Detector Design Implications

A simple power law model consisting of a single spectral index (alpha-1) is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy (E(sub k)) to a steeper spectral index alpha-2 > alpha-1 above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Observation of oxide particles below the apparent oxygen solubility limit in tantalum

The apparent solubility of oxygen in polycrystalline tantalum as determined by the X-ray diffraction lattice parameter technique is about 1.63 atomic percent at 820 C. However, oxide particles were identified in samples containing as low as 0.5 atomic percent of oxygen. These oxide particles were present at the grain boundaries and within the grains. The number of oxide particles increased with increasing oxygen concentration in tantalum. The presence of oxide particles suggests that the true solubility of oxygen in the polycrystalline tantalum metal is probably significantly lower than that reported in the literature.

Stecura, S.↗

Observation of oxide particles below the apparent oxygen solubility limit in tantalum

The apparent solubility of oxygen in polycrystalline tantalum as determined by the X-ray diffraction lattice parameter technique is about 1.63 at. pct at 820 C. However, oxide particles were identified in samples containing as low as 0.5 at. pct oxygen. These particles were present at the grain boundaries and within the grains. The number of oxide particles increased with increasing oxygen concentration in tantalum. The presence of oxide particles suggests that the true solubility in the polycrystalline tantalum metal is probably lower than that reported in the literature.

Stecura, S.↗

Gulf of Mexico satellite radar altimetry

The dynamic topography of the sea surface was measured. The radar altimeter measurements yield average ocean topographic data which are mapped. Seasonal deviations from a 3 year mean topography are presented. The altimeters are also instrumented with sample and hold gates which provide information about the shape and amplitude of the return waveform. Parameters including ocean surface wind speed and the significant wave height are determined. One hundred eighty six wind speed and significant wave height histograms are presented.

Parra, C. G.↗

A system study for the application of microcomputers to research flight test techniques

The onboard simulator is a three degree of freedom aircraft behavior simulator which provides parameters used by the interception procedure. These parameters can be used for verifying closed loop performance before flight. The air to air intercept mode is a software package integrated in the simulation process that generates a target motion and performs a tracking procedure that predicts the most likely next target position, for a defined time step. This procedure also updates relative position parameters and gives adequate fire commands. A microcomputer based on an aircraft spin warning system periodically samples the assymetric thrust and yaw rate of an airplane and then issues voice synthesized warnings and /or suggests to the ilot how to respond to the situation.

Smyth, R. K.↗

Theoretical aspects of photoclinometric terrain profiling on the Galilean satellites

For large parts of the surfaces of the Galilean satellites there is no stereoscopic high resolution imagery, and so for shadow-free regions far from the terminator, the only method of obtaining topograpic information is photoclinometry, the technique of converting brightness variations into local surface tilts and hence into topographic profiles and contour maps. The conversion from brightness changes to slopes require knowledge of the angular photometric function for the type of planetary surface terrain being analyzed, i.e., the relationship describing the brightness of the surface as a function of the angles of incidence (I) and emergence (E) of light at a surface element. In order to investigate the effects of these changes on the shapes of topographic profiles deduced from the functions, an area of grooved terrain (lines 500-505, samples 550-650 on frame 20640.27 0060J2) using wide ranges of values of all the adjustable parameters in Hapke's new photometric function were analyzed.

Wilson, L.↗

High frequency power distribution system

The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

Patel, Mikund R.↗