Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oxygen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Characterization of Virgin, Re-used, and Oxygen-reduced Copper Powders processed by the Plasma Spheroidization Process

We report that fabrication of parts with high mechanical properties heavily depend on the quality of powder deployed in the fabrication process. Copper powder in three different powder types were spheroidized using radio-frequency inductively coupled plasma (ICP) spheroidization process (TekSphero-15 system). The characterized powders include virgin powder as purchased from the powder manufacturer, powder used in electron beam powder bed fusion (EB-PBF) process, and reconditioned powder, which was used powder that underwent an oxygen-reduction treatment. The goal of spheroidizing these powder types was to evaluate the change in powder morphology, the possibility of enhancing the powder properties back to their as-received conditions, and assess oxygen reduction of the powder lots given their initial oxygen contents. Also, to investigate the impact of re-spheroidization on powder properties, the second round of spheroidization was performed on the already used-spheroidized powder. The impact of powder type on powder sphericity and particle size distribution was evaluated using the image analysis of scanning electron microscope (SEM) micrographs and laser diffraction, respectively. The spheroidized powder showed higher sphericity and more uniform particle size distribution overall. Depending on the powder collection bin, second round of spheroidization affected the powder sphericity differently. The possibility of deploying the plasma spheroidization process as an alternative oxygen-reduction technique was also investigated through tracking the powders’ oxygen content using inert gas fusion method before and after the spheroidization. The plasma spheroidized powder showed less oxygen content than the hydrogen-treated powder. The second round of spheroidization caused no change in oxygen content. The correlation between oxygen-reduction and created cracks was discussed and compared between plasma spheroidization and hydrogen-treatment. The plasma spheroidization process created a powder with higher sphericity, uniform particle size, and less oxygen content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sorbent-based oxygen separation with YBC114 for energy storage systems

In our report we aimed to design, build, and evaluate an oxygen separation system to provide an inert sweep gas with low oxygen partial pressure (pO2) to redox-active thermochemical energy conversion reactors for a range of applications, including two-step redox cycles for thermochemical energy storage, water splitting, and carbon-dioxide splitting. The separation is based on an oxygen-selective sorbent, YBaCo4O7+δ (YBC114), which has excellent oxygen sorption and desorption properties demonstrated in our previous work. The oxygen separation performance of YBC114 was comprehensively studied by thermogravimetric analysis, sorption breakthrough experiments, and temperature swing sorption - desorption cycles. The results reveal that YBC114 can produce inert sweep gas with an oxygen concentration of less than 100 ppmv for at least 20 min during the thermal swing adsorption (TSA) cycle with the current sorption bed configuration, and the performance is consistent from cycle to cycle. The optimal sorption and desorption temperatures for the TSA process with YBC114 are determined to be 300 °C and 500 °C, respectively. Although challenges remain for the current separation system (e.g., high sorption temperature and slow kinetics), this study demonstrates the potential to use the oxygen-selective sorbent to produce an inert sweep gas, the feasibility of the oxygen separation concept, and guides new sorbent material development to make this application economically practical. A simple procedure is described for designing the YBC114 oxygen separation process.

42 ENGINEERING↗

Investigation of oxygen vacancy and photoluminescence in calcium tungstate nanophosphors with different particle sizes

Highlights: • CaWO{sub 4} nanophosphors with different particle sizes were prepared by hydrothermal processes through controlling the concentration of surfactant. • Green emission band of oxygen vacancy in CaWO{sub 4} nanophosphor was clearly observed upon the irradiation of 350 nm excitation. • The concentration of oxygen vacancy in CaWO{sub 4} nanophosphor could be increased by reducing its size. - Abstract: Calcium tungstate (CaWO{sub 4}) nanophosphors with the particle sizes from 35 to 90 nm were synthesized by a hydrothermal process through exactly controlling the pre-treated conditions. The influence of particle size on oxygen vacancy and photoluminescence properties in CaWO{sub 4} nanophosphors was investigated and discussed. The crystal structure of the CaWO{sub 4} nanophosphors presented a certain level of distortion due to the high concentration of oxygen vacancy. Under 350 nm excitation, a clear green emission aroused by oxygen vacancy was observed. The possible luminescence processes for the matrix and oxygen vacancy were proposed. The luminescence spectra of the nanophosphors revealed that the emission and absorption intensity aroused by oxygen vacancy were both enhanced when the size is decreased. On the basis of the above results, the essential relationship between particle size and oxygen vacancy in CaWO{sub 4} nanophosphors was concluded that the concentration of oxygen vacancy could be increased by reducing its size, which was further confirmed by decay lifetimes.

36 MATERIALS SCIENCE↗

Identification of an Archean marine oxygen oasis

The early Earth was essentially anoxic. A number of indicators suggest the presence of oxygenic photosynthesis 2700 3000 million years (Ma) ago, but direct evidence for molecular oxygen (O2) in seawater has remained elusive. Here we report rare earth element (REE) analyses of 2800 million year old shallowmarine limestones and deep-water iron-rich sediments at Steep Rock Lake, Canada. These show that the seawater from which extensive shallow-water limestones precipitated was oxygenated, whereas the adjacent deeper waters where iron-rich sediments formed were not. We propose that oxygen promoted limestone precipitation by oxidative removal of dissolved ferrous iron species, Fe(II), to insoluble Fe(III) oxyhydroxide, and estimate that at least 10.25 M oxygen concentration in seawater was required to accomplish this at Steep Rock. This agrees with the hypothesis that an ample supply of dissolved Fe(II) in Archean oceans would have hindered limestone formation. There is no direct evidence for the oxygen source at Steep Rock, but organic carbon isotope values and diverse stromatolites in the limestones suggest the presence of cyanobacteria. Our findings support the view that during the Archean significant oxygen levels first developed in protected nutrient-rich shallow marine habitats. They indicate that these environments were spatially restricted, transient, and promoted limestone precipitation. If Archean marine limestones in general reflect localized oxygenic removal of dissolved iron at the margins of otherwise anoxic iron-rich seas, then early oxygen oases are less elusive than has been assumed.

carbonate platform↗

Ultrafast Oxygen Conduction in Sillén Oxychlorides

Oxygen ion conductors are crucial for enhancing the efficiency of various clean energy technologies, including fuel cells, solid oxide air batteries, electrolyzers, membranes, sensors, and more. In this study, a structure-similarity analysis of ≈62k oxygen-containing compounds identified the MBi 2 O 4 X (M = rare-earth element, X = halogen element) family as promising candidates for fast oxygen transport. Among these, LaBi 2 O 4 Cl is found as an ultrafast oxygen conductor with an ultralow migration barrier of 0.1 eV based on ab initio studies. Its 2D layered structure, featuring a “triple fluorite” layer, supports diffusion of both oxygen vacancies and interstitials. In addition to vacancy diffusion with a 0.1 eV barrier, ab initio studies show interstitial diffusion exhibits a modest barrier of 0.6–0.8 eV. Frenkel pairs are found to be the dominant defects in intrinsic LaBi 2 O 4 Cl, facilitating significant vacancy-mediated oxygen diffusion at elevated temperatures. With 2.8% oxygen vacancies, LaBi 2 O 4 Cl is predicted to achieve a conductivity of 0.3 S/cm at 25 °C in a single crystal. Experimental synthesis and characterization of polycrystalline LaBi 2 O 4 Cl and Sr-doped LaBi 2 O 4 Cl revealed conductivity exceeding that of YSZ and LSGM below 400 °C, with lower activation energies, achieving a total conductivity of 0.1−0.2 mS/cm at 300 °C. Here, while these results confirm its potential of fast oxygen transport, we suggest further experimental optimization of LaBi 2 O 4 Cl, including aliovalent doping and microstructure refinement, could significantly enhance its performance, facilitating fast oxygen conduction approaching room temperature.

Defects↗

Layered Oxide Cathodes for Li-Ion Batteries: Oxygen Loss and Vacancy Evolution

Loss of oxygen in layered transition metal oxides is a major reason for the structural degradation and thus the fade of electrochemical performance in the cathodes for Li-ion batteries. Via in-situ transmission electron microscopy observations of LiNi 0.80 Co 0.15 Al 0.05 O 2 (NCA), we found that the oxygen loss in the layered cathode is a two-stage process with distinct release rates. The initial rapid oxygen loss generates a high concentration of oxygen vacancies that results in the formation of an amorphized, vacancy-containing rock-salt layer in the surface. In the second stage, the slower rate of oxygen loss allows recrystallization of this defective phase via coalescing of atomic oxygen vacancies, which results in the formation of a cavity-containing surface layer with a crystalline rock-salt structure over the layered phase in the bulk. Comparison of the in-situ results with electrochemically cycled NCA cathodes confirms this two-stage process of oxygen loss. Furthermore, these results provide unprecedented microscopic details regarding the structural degradation of layered oxides arising from oxygen loss and have broader implications in manipulating the oxygen activity in the electrode.

36 MATERIALS SCIENCE↗

Effects of Hydration and Oxygen Vacancy on CO2 Adsorption and Activation on β-Ga2O3(100)

The effects of hydration and oxygen vacancy on CO2 adsorption on the β-Ga2O3(100) surface have been studied using density functional theory slab calculations. Adsorbed CO2 is activated on the dry perfect β-Ga2O3(100) surface, resulting in a carbonate species. This adsorption is slightly endothermic, with an adsorption energy of 0.07 eV. Water is preferably adsorbed molecularly on the dry perfect β-Ga2O3(100) surface with an adsorption energy of -0.56 eV, producing a hydrated perfect β-Ga2O3(100) surface. Adsorption of CO2 on the hydrated surface as a carbonate species is also endothermic, with an adsorption energy of 0.14 eV, indicating a slight repulsive interaction when H2O and CO2 are coadsorbed. The carbonate species on the hydrated perfect surface can be protonated by the co-adsorbed H2O to a bicarbonate species, making the overall process exothermic with an adsorption energy of -0.13 eV. The effect of defects on CO2 adsorption and activation has been examined by creating an oxygen vacancy on the dry β-Ga2O3(100) surface. The formation of an oxygen vacancy is endothermic, by 0.34 eV, with respect to a free O2 molecule in the gas phase. Presence of the oxygen vacancy promoted the adsorption and activation of CO2. In the most stable CO2 adsorption configuration on the dry defective β-Ga2O3(100) surface with an oxygen vacancy, one of the oxygen atoms of the adsorbed CO2 occupies the oxygen vacancy site and the CO2 adsorption energy is -0.31 eV. Water favors dissociative adsorption at the oxygen vacancy site on the defective surface. This process is instantaneous with an adsorption energy of -0.62 eV. These results indicate that, when water and CO2 are both present in the adsorption system simultaneously, the water molecule will compete with CO2 for the oxygen vacancy sites and impact CO2 adsorption and conversion negatively. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy. A portion of the computing time was granted by the scientific user projects using the Molecular Science Computing Facility in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL). The EMSL is a DOE national scientific user facility located at PNNL, and supported by the DOE’s Office of Science, Biological and Environmental Research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxygen vacancy formation characteristics in the bulk and across different surface terminations of La (1₋x) Sr x Fe (1₋y) Co y O (3₋δ) perovskite oxides for CO 2 conversion

Density functional theory (DFT) based investigation of two parameters of prime interest -- oxygen vacancy and surface terminations along (100) and (110) planes -- has been conducted for La (1-x) Sr x Fe(1-y)Co y O (3-$\delta$) perovskite oxides in view of their application towards thermochemical carbon dioxide conversion reactions. The bulk oxygen vacancy formation energies for these mixed perovskite oxides are found to increase with increasing lanthanum and iron contents in the 'A' site and 'B' site, respectively. Surface terminations along (100) and (110) crystal planes are studied to probe their stability and their capabilities to accommodate surface oxygen vacancies. Amongst the various terminations, the oxygen-rich (110) surface and strontium-rich (100) surface are the most stable, while transition metal-rich terminations along (100) revealed preference towards the production of oxygen vacancies. The carbon dioxide adsorption strength, a key descriptor for CO 2 conversion reactions, is found to increase on oxygen vacant surfaces thus establishing the importance of oxygen vacancies in CO 2 conversion reactions. Amongst all the surface terminations, the lanthanum-oxygen terminated surface exhibited the strongest CO 2 adsorption strength. Finally, the theoretical prediction of the oxygen vacancy trends and the stability of the samples were corroborated by the temperature-programmed reduction and oxidation reactions and in situ XRD crystallography.

36 MATERIALS SCIENCE↗

Modeling of the oxygen reduction reaction for dense LSM thin films

In this study, the oxygen reduction reaction mechanism is investigated using numerical methods on a dense thin (La 1-x Sr x ) y MnO 3±δ film deposited on a YSZ substrate. This 1-D continuum model consists of defect chemistry and elementary oxygen reduction reaction steps coupled via reaction rates. The defect chemistry model contains eight species including cation vacancies on the A- and B-sites. The oxygen vacancy is calculated by solving species transportation equations in multiphysics simulations. Due to the simple geometry of a dense thin film, the oxygen reduction reaction was reduced to three elementary steps: surface adsorption and dissociation, incorporation on the surface, and charge transfer across the LSM/YSZ interface. The numerical simulations allow for calculation of the temperature- and oxygen partial pressure-dependent properties of LSM. The parameters of the model are calibrated with experimental impedance data for various oxygen partial pressures at different temperatures. The results indicate that surface adsorption and dissociation is the rate-determining step in the ORR of LSM thin films. With the fine-tuned parameters, further quantitative analysis is performed. The activation energy of the oxygen exchange reaction and the dependence of oxygen non-stoichiometry on oxygen partial pressure are also calculated and verified using the literature results.

36 MATERIALS SCIENCE↗

Photochemical processes in doped argon-neon core-shell clusters: The effect of cage size on the dissociation of molecular oxygen

The caging effect of the host environment on photochemical reactions of molecular oxygen is investigated using monochromatic synchrotron radiation and spectrally resolved fluorescence. Oxygen doped clusters are formed by coexpansion of argon and oxygen, by pickup of molecular oxygen or by multiple pickup of argon and oxygen by neon clusters. Sequential pickup provides radially ordered core-shell structures in which a central oxygen molecule is surrounded by argon layers of variable thickness inside large neon clusters. Pure argon and core-shell argon-neon clusters excited with {approx}12 eV monochromatic synchrotron radiation show strong fluorescence in the vacuum ultraviolet (vuv) spectral range. When the clusters are doped with O{sub 2}, fluorescence in the visible (vis) spectral range is observed and the vuv radiation is found to be quenched. Energy-resolved vis fluorescence spectra show the 2 {sup 1}{sigma}{sup +}{yields}1 {sup 1}{sigma}{sup +}(ArO({sup 1}S){yields}ArO({sup 1}D)) transition from argon oxide as well as the vibrational progression A {sup '3}{delta}{sub u}({nu}{sup '}=0){yields}X {sup 3}{sigma}{sub g}{sup -}({nu}{sup ''}) of O{sub 2} indicating that molecular oxygen dissociates and occasionally recombines depending on the experimental conditions. Both the emission from ArO and O{sub 2} as well the vuv quenching by oxygen are found to depend on the excitation energy, providing evidence that the energy transfer from the photoexcited cluster to the embedded oxygen proceeds via the O{sub 2}{sup +} ground state. The O{sub 2}{sup +} decays via dissociative recombination and either reacts with Ar resulting in electronically excited ArO or it recombines to O{sub 2} within the Ar cage. Variation of the Ar layer thickness in O{sub 2}-Ar-Ne core-shell clusters shows that a stable cage is formed by two solvation layers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxygen content tailored magnetic and electronic properties in cobaltite double perovskite thin films

Oxygen content in transition metal oxides is one of the most important parameters to control for the desired physical properties. Recently, we have systematically studied the oxygen content and property relationship of the double perovskite PrBaCo 2 O 5.5+δ (PBCO) thin films deposited on the LaAlO 3 substrates. The oxygen content in the films was varied by in-situ annealing in a nitrogen, oxygen, or ozone environment. Associated with the oxygen content, the out-of-plane lattice parameter progressively decreases with increasing oxygen content in the films. The saturated magnetization shows a drastic increase and resistivity is significantly reduced in the ozone annealed samples, indicating the strong coupling between physical properties and oxygen content. Furthermore, these results demonstrate that the magnetic properties of PBCO films are highly dependent on the oxygen contents, or the film with higher oxygen uptake has the largest magnetization.

36 MATERIALS SCIENCE↗

Strain coupling of oxygen non-stoichiometry in perovskite thin films

The effects of strain and oxygen vacancies on perovskite thin films have been studied in great detail over the past decades and have been treated separately from each other. While epitaxial strain has been realized as a tuning knob to tailor the functional properties of correlated oxides, oxygen vacancies are usually regarded as undesirable and detrimental. In transition metal oxides, oxygen defects strongly modify the properties and functionalities via changes in oxidation states of the transition metals. However, such coupling is not well understood in epitaxial films, but rather deemed as cumbersome or experimental artifact. Only recently it has been recognized that lattice strain and oxygen non-stoichiometry are strongly correlated in a vast number of perovskite systems and that this coupling can be beneficial for information and energy technologies. Recent experimental and theoretical studies have focused on understanding the correlated phenomena between strain and oxygen vacancies for a wide range of perovskite systems. These correlations not only include the direct relationship between elastic strain and the formation energy of oxygen vacancies, but also comprise highly complex interactions such as strain-induced phase transitions due to oxygen vacancy ordering. Therefore, we aim in this review to give a comprehensive overview on the coupling between strain and oxygen vacancies in perovskite oxides and point out the potential applications of the emergent functionalities strongly coupled to oxygen vacancies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Oxygen Inhomogeneity and Reversibility in Single Crystal LaNiO{sub 3-{delta}}.

LaNiO 3− δ single crystals have been obtained via high pressure floating zone growth under 149 bar of oxygen pressure. We find a radial gradient in the magnetic properties of specimens extracted from the as-grown boule, which we correlate with the appearance of ordered oxygen vacancy structures. This radial oxygen inhomogeneity has been characterized systematically using a combination of magnetization and X-ray scattering measurements. We establish the presence of rhombohedral ( R 3 ¯ c ), oxygen stoichiometric specimens at the periphery of the boule and the presence of a dilute concentration of ordered oxygen-deficient orthorhombic La 2 Ni 2 O 5 in the center. Furthermore, we demonstrate that the as-grown, oxygen-deficient central regions of the crystal can be annealed under high oxygen pressure, without loss of crystallinity, into fully oxygenated LaNiO 3 , recovering magnetic properties that are characteristic of stoichiometric specimens from the exterior region of the crystal. Thus, single crystals of LaNiO 3− δ possess oxygen content that can be reversibly modified under oxidizing and reducing conditions.

crystal growth↗

Real-Time Identification of Oxygen Vacancy Centers in LiNbO 3 and SrTiO 3 during Irradiation with High Energy Particles

Oxygen vacancies are known to play a central role in the optoelectronic properties of oxide perovskites. A detailed description of the exact mechanisms by which oxygen vacancies govern such properties, however, is still quite incomplete. The unambiguous identification of oxygen vacancies has been a subject of intense discussion. Interest in oxygen vacancies is not purely academic. Precise control of oxygen vacancies has potential technological benefits in optoelectronic devices. In this review paper, we focus our attention on the generation of oxygen vacancies by irradiation with high energy particles. Irradiation constitutes an efficient and reliable strategy to introduce, monitor, and characterize oxygen vacancies. Unfortunately, this technique has been underexploited despite its demonstrated advantages. This review revisits the main experimental results that have been obtained for oxygen vacancy centers (a) under high energy electron irradiation (100 keV–1 MeV) in LiNbO 3 , and (b) during irradiation with high-energy heavy (1–20 MeV) ions in SrTiO 3 . In both cases, the experiments have used real-time and in situ optical detection. Moreover, the present paper discusses the obtained results in relation to present knowledge from both the experimental and theoretical perspectives. Our view is that a consistent picture is now emerging on the structure and relevant optical features (absorption and emission spectra) of these centers. One key aspect of the topic pertains to the generation of self-trapped electrons as small polarons by irradiation of the crystal lattice and their stabilization by oxygen vacancies. What has been learned by observing the interplay between polarons and vacancies has inspired new models for color centers in dielectric crystals, models which represent an advancement from the early models of color centers in alkali halides and simple oxides. The topic discussed in this review is particularly useful to better understand the complex effects of different types of radiation on the defect structure of those materials, therefore providing relevant clues for nuclear engineering applications.

36 MATERIALS SCIENCE↗

Forearm muscle oxygenation decreases with low levels of voluntary contraction

The purpose of our investigation was to determine if the near infrared spectroscopy technique was sensitive to changes in tissue oxygenation at low levels of isometric contraction in the extensor carpi radialis brevis muscle. Nine subjects were seated with the right arm abducted to 45 degrees, elbow flexed to 85 degrees, forearm pronated 45 degrees, and wrist and forearm supported on an armrest throughout the protocol. Altered tissue oxygenation was measured noninvasively with near infrared spectroscopy. The near infrared spectroscopy probe was placed over the extensor carpi radialis brevis of the subject's right forearm and secured with an elastic wrap. After 1 minute of baseline measurements taken with the muscle relaxed, four different loads were applied just proximal to the metacarpophalangeal joint such that the subjects isometrically contracted the extensor carpi radialis brevis at 5, 10, 15, and 50% of the maximum voluntary contraction for 1 minute each. A 3-minute recovery period followed each level of contraction. At the end of the protocol, with the probe still in place, a value for ischemic tissue oxygenation was obtained for each subject. This value was considered the physiological zero and hence 0% tissue oxygenation. Mean tissue oxygenation (+/-SE) decreased from resting baseline (100% tissue oxygenation) to 89 +/- 4, 81 +/- 8, 78 +/- 8, and 47 +/- 8% at 5, 10, 15, and 50% of the maximum voluntary contraction, respectively. Tissue oxygenation levels at 10, 15, and 50% of the maximum voluntary contraction were significantly lower (p < 0.05) than the baseline value. Our results indicate that tissue oxygenation significantly decreases during brief, low levels of static muscle contraction and that near infrared spectroscopy is a sensitive technique for detecting deoxygenation noninvasively at low levels of forearm muscle contraction. Our findings have important implications in occupational medicine because oxygen depletion induced by low levels of muscle contraction may be directly linked to muscle fatigue.

NASA Center ARC↗

Ground Test Stand Development for One-step Electrochemical Production of High-Pressure Oxygen

NASA designed a test rig, High-Pressure Oxygen Generation Assembly (HPOGA) to test a novel method of electrolysis as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) currently on the International Space Station (ISS). This approach involves utilizing a specialized electrolysis cell stack designed to both generate and compress high-pressure oxygen up to 3600 PSIG. The design eliminates the need for an external compressor and hydrogen separator, streamlining the oxygen generation process. HPOGA tests the viability of an electrolysis cell stack for extended life usage. Within the system, there are several key subsystems: nitrogen, high/low pressure oxygen, hydrogen, water recirculation, and water injection. The water injection subsystem supplies deionized (DI) water to a centralized reservoir for consumption. Subsequently, a water recirculation loop transfers the DI water across the cathode side of the electrolysis cell stack with constant flow rate. The result is a supply of hydrogen in the water loop and oxygen accumulation on the anode side of the cell stack. Hydrogen is evaporated out as part of the hydrogen sub-system which also measures hydrogen/oxygen concentration for safety. The oxygen subsystem is responsible for managing high pressure oxygen, O2 exhaust, and conducting hydrogen/oxygen concentration measurements. The nitrogen subsystem serves dual functions, purging the hydrogen/oxygen subsystems, and regulating pressure in both high/low-pressure O2 sections via pneumatic back pressure regulators. Various sensors monitor pressure, temperature, humidity, gas concentration and flow rate in each subsystem. This paper presents the design and testing of a comprehensive test stand, which serves to operate and functionally verify the performance of the electrolysis cell while offering valuable lessons learned.

electrolysis↗

Optimal interpolation of global dissolved oxygen: 1965–2015

Oxygen inventory of the global ocean has declined in recent decades potentially due to the warming-induced reduction in solubility as well as the circulation and biogeochemical changes associated with ocean warming and increasing stratification. Earth System Models predict continued oxygen decline for this century with profound impacts on marine ecosystem and fisheries. Observational constraint on the rate of oxygen loss is crucial for assessing the ability of models to accurately simulate these changes. There are only a few observational assessments of the global oceanic oxygen inventory reporting a range of oxygen loss. This study develops a gridded data set of dissolved oxygen for the global oceans using optimal interpolation method. The resulting gridded product includes full-depth map of dissolved oxygen as 5-year moving average from 1965 to 2015 with uncertainty estimates. The uncertainty can come from unresolved small-scale and high-frequency variability and mapping errors. The multi-decadal trend of global dissolved oxygen is in the range of -281 to -373 Tmol/decade. This estimate is more conservative than previous works. In this study, the grid points far from the observations are essentially set equal to zero anomaly from the climatology. Calculating global inventory with this approach produces a relatively conservative estimate; thus, the results from this study likely provide a useful lower bound estimate of the global oxygen loss.

54 ENVIRONMENTAL SCIENCES↗