Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Air-stable, earth-abundant molten chlorides and corrosion-resistant containment for chemically-robust, high-temperature thermal energy storage for concentrated solar power

A dramatic reduction in man-made CO 2 emissions could be achieved if the cost of electricity generated from concentrated solar power (CSP) plants could become competitive with fossil-fuel-derived electricity. The solar heat-to-electricity conversion efficiency of CSP plants may be significantly increased (and the associated electricity cost decreased) by operating CSP turbines with inlet temperatures ≥750 °C instead of ≤550 °C, and by using thermal energy storage (TES) at ≥750 °C to allow for rapidly dispatchable and/or continuous electricity production. Unfortunately, earth-abundant MgCl 2 -KCl-based liquids currently being considered as low-cost media for large-scale, high-temperature TES are susceptible to oxidation in ambient air, with associated undesired changes in liquid composition and enhanced corrosion of metal alloys in pipes and tanks containing such liquids. In this paper, alternative high-temperature, earth-abundant molten chlorides that are resistant to oxidation in ambient air are identified via thermodynamic calculations. Here, the oxidation resistance, and corrosion-resistant containment, of such molten chlorides at 750 °C are then demonstrated. Such an air-tolerant strategy, involving chemically-robust, low-cost TES media paired with effective containment materials, provides a critical advance towards the higher-temperature operation of, and lower-cost electricity generation from, CSP plants.

14 SOLAR ENERGY↗

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

Costs of Exposure to Industrial Livestock Operations

Concentrated animal feeding operations, particularly hog and poultry farms, have expanded rapidly in North Carolina in recent decades. The air pollution and water contamination they generate cause many environmental and health problems for local communities. Using the universe of farm characteristics and housing transaction data in North Carolina, we recover hedonic estimates of property value impacts from exposure to these industrial livestock operations. Furthermore, our results show large and significant negative impacts on nearby home values, particularly when those properties depend on private wells.

Concentrated Animal Feeding Operation↗

Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

25 ENERGY STORAGE↗

Optimal Design Approaches for Cost-Effective Manufacturing and Deployment of Chemical Process Families with Economies of Numbers

Developing methods for rapid, large-scale deployment of carbon capture systems is critical for meeting climate change goals. Optimization-based decisions can be employed at the design and manufacturing phases to minimize costs of deployment and operation. Manufacturing standardization results in significant cost savings due to economies of numbers. Building off previous work, we present a process family design approach to design a set of carbon capture systems while explicitly including economies of numbers savings within the formulation. Our formulation optimizes both the number and characteristics of the common components in the platform and simultaneously designs the resulting set of carbon capture systems. Savings from economies of numbers are explicitly included in the formulation to determine the number of components in the platform. We show and discuss the savings we gain from economies of numbers.

Stinchfield, Georgia↗

Research Highlight - Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

We highlight our work from our previous publication titled "Dispatch Optimization, System Design, and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage" published in MDPI Energies 2022 (doi.org/10.3390/en15103599). Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

97 MATHEMATICS AND COMPUTING↗

Accessing and Understanding REopt's Federal Assumptions

REopt is a techno-economic analysis platform accessible as a user-friendly web tool that facilitates life cycle cost analysis of distributed energy resources. It is typically used for preliminary assessments to identify the least-cost technology mix, system sizing, and operations strategies towards agency cost savings and resilience goals. This guide identifies and explains REopt inputs for federal life cycle cost analyses, modified from their commercial default values. These federal input defaults are based on statutory requirements for life cycle cost analyses of energy conservation measures at federal facilities per 10 CFR 436 Subpart A.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Expedited desalination permitting enables adaptive planning and water system cost reduction

Seawater desalination is a drought-proof water supply for coastal cities, but widespread development of desalination plants in the U.S. has been limited by both cost and the complexity of permitting processes designed to minimize environmental impact . This work estimates the value of accelerating the permitting timeline without changing environmental or social standards. On average, faster permitting reduces the frequency of desalination plant construction and operation, the overall costs of robust water system operation, the environmental impacts of drought-tolerant water supplies due to shorter duration of plant operation. Expedited permitting allows fundamental changes in how water infrastructure is deployed, facilitating a transition from anticipatory construction and continuous operation of seawater desalination capacity as a redundant drought buffer to just-in-time (i.e. adaptive) deployment of seawater desalination capacity when critical drought thresholds are crossed. We demonstrate the value of expedited desalination permitting in enabling adaptive planning and reducing water system costs using a simple case study in Santa Barbara, CA. We discuss additional forms of adaptive water infrastructure planning as enabled by faster permitting and address their challenges and opportunities. Lastly, we identify synergies between innovation in adaptive planning, innovation in expedited permitting practices, and innovation in water technology.

adaptive planning↗

Enhancing Lifetime and Reducing Costs for Fish Diversion Netting Structures (Final Report)

In this effort Pacific Northwest National Laboratory (PNNL) developed and demonstrated an anti-fouling coating that is effective on fish diversion structures. The coating was based on a previously developed superhydrophobic lubricant infused composite (SLIC) coating but modified for application to flexible substrates. We showed that the new reformulated coating – FlexiSLIC – can be applied to flexible fibrous structures to significantly reduce biofouling of netting and anchor lines, to enable longer operational lifetimes, reduced costs, and more reliable operations. The coating developed in this effort was tested on relevant fish diversion structural netting and rope materials (e.g. nylon, Dyneema, polypropylene) to reduce biofouling. Engagement with industry in the development and demonstration further supported progress toward commercialization of the materials.

36 MATERIALS SCIENCE↗

Levelized Cost of CO 2 Captured Using Five Physical Solvents in Pre-combustion Applications

Aspen Plus v8.8 was used to perform techno-economic analysis (TEA) of a CO 2 capture process from a typical fuel gas stream in a 543-MW pre-combustion power plant using five different physical solvents (Selexol, PEGPDMS-1, NMP, [aPy][Tf 2 N] and [hmim][Tf 2 N]). The process included a countercurrent packed-bed absorber operating under high-pressure over a wide range of temperatures and three pressure-swing flash drums for solvent regeneration. Furthermore, two packings, Mellapak 250Y and IMTP50, were used and the Levelized costs of CO 2 captured (LCOC) were calculated. The simulation results indicated that using Mellapak 250Y exhibited lower LCOC values than those when using IMTP50 for the five solvents under all conditions used as it offered better mass transfer. The CO 2 capture process carried out at low temperatures showed lower LCOC values than those at higher temperatures due to the increased CO 2 solubility in the solvents at lower temperatures, requiring smaller absorber diameter and lower solvent circulation rates, which offset the cooling requirements. Comparing the lowest LCOC values for the five solvents, the hydrophobic PEGPDMS-1 solvent was the most promising one compared to the other four solvents, due to its lowest capital and operating costs and noncorrosive, which enabled using less expensive materials for the process equipment.

42 ENGINEERING↗

Wireless Interrogation of High Temperature Surface Acoustic Wave Dynamic Strain Sensor

Dynamic strain sensing is necessary for high-temperature harsh-environment applications, including powerplants, oil wells, aerospace, and metal manufacturing. Monitoring dynamic strain is important for structural health monitoring and condition-based maintenance in order to guarantee safety, increase process efficiency, and reduce operation and maintenance costs. Sensing in high-temperature (HT), harsh-environments (HE) comes with challenges including mounting and packaging, sensor stability, and data acquisition and processing. Wireless sensor operation at HT is desirable because it reduces the complexity of the sensor connection, increases reliability, and reduces costs. Surface acoustic wave resonators (SAWRs) are compact, can operate wirelessly and battery-free, and have been shown to operate above 1000°C, making them a potential option for HT HE dynamic strain sensing. This paper presents wirelessly interrogated SAWR dynamic strain sensors operating around 288.8MHz at room temperature and tested up to 400°C. The SAWRs were calibrated with a high-temperature wired commercial strain gauge. The sensors were mounted onto a tapered-type Inconel constant stress beam and the assembly was tested inside a box furnace. The SAWR sensitivity to dynamic strain excitation at 25°C, 100°C, and 400°C was .439 μV/με, 0.363μV/με, and .136 μV/με, respectively. Furthermore, the experimental outcomes verified that inductive coupled wirelessly interrogated SAWRs can be successfully used for dynamic strain sensing up to 400°C.

47 OTHER INSTRUMENTATION↗

Exploring the fusion power plant design space: comparative analysis of positive and negative triangularity tokamaks through optimization

The optimal configuration choice between positive triangularity (PT) and negative triangularity (NT) tokamaks for fusion power plants hinges on navigating different operational constraints rather than achieving specific plasma performance metrics. This study presents a systematic comparison using constrained multi-objective optimization with the integrated FUsion Synthesis Engine (FUSE) framework. Over 200 000 integrated design evaluations were performed exploring the trade-offs between capital cost minimization and operational reliability (maximizing q 95 ) while satisfying engineering constraints including 250 ± 50 MW net electric power, tritium breeding ratio > 1.1, power exhaust limits and an hour flattop time. Both configurations achieve similar cost-performance Pareto fronts through contrasting design philosophies. PT, while demonstrating resilience to pedestal degradation (compensating for up to 40% reduction), are constrained to larger machines (R 0 > 6.5 m) by the narrow operational window between L–H threshold requirements and the research-established power exhaust limit (P sol /R < 15 MW m –1 ). This forces optimization through comparatively reduced magnetic field (∼8 T). NT configurations exploit their freedom from these constraints to access compact, high-field designs (R 0 ~ 5.5 m, B 0 >12 T), creating natural synergy with advancing HTS technology. Sensitivity analyses reveal that PT’s economic viability depends critically on uncertainties in L–H threshold scaling and power handling limits. Notably, a 50% variation in either could eliminate viable designs or enable access to the compact design space. These results suggest configuration selection should be risk-informed: PT offers the lowest-cost path when operational constraints can be confidently predicted, while NT is robust to large variations in constraints and physics uncertainties.

FUSE framework↗

Deep Reinforcement Learning for Residential HVAC Control with Consideration of Human Occupancy

The Artificial Intelligence (AI) development described herein uses model-free Deep Reinforcement Learning (DRL) to minimize energy cost during residential heating, ventilation, and air conditioning (HVAC) operation. Building cooling loads and HVAC operation are difficult to accurately model due to complexity, lack of measurements and data, and model specific performance, so online machine learning is used to allow for real-time readjustment in performance. Energy costs for the multi-zone cooling unit shown in this work are minimized by scheduling on/off commands around dynamic prices. By taking advantage of precooling events that take place when the price is low, the agent is able to reduce operational cost without violating user comfort. The DRL controller was tested in simulation where the learner achieved a 43.89% cost reduction when compared to traditional, fixed-setpoint operation. The system is now ready for the next phase of testing in a live, real-time home environment.

Mckee, Evan↗

Cooperative Transmission Expansion Planning Experiment Data and Results

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within GO WEST framework. In this sense, TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. TEP minimizes the total cost of the system which comprises the operational cost of satisfying electricity demand (i.e., generation cost), cost of loss of load (i.e., unserved energy), cost of power flow, and cost of new transmission capacity additions (i.e., investment cost). In order to use TEP model, users need to create scenarios with GO WEST framework. In this analysis, outputs from several models are used to create future inputs to GO WEST and TEP models, including GCAM-USA, TELL, CERF and reV. This dataset includes experiment inputs and outputs from three different transmission expansion scenarios (cooperative, intermediate, and individual) for 2019 and 2059. For 2019, a base scenario to illustrate the default (i.e., historical) power grid operations is also included. This study utilizes rcp45hotter_ssp3 scenario from a previous version of GCAM-USA simulations. Sources of the shapefiles in supplementary data are HIFLD Open and U.S. Energy Atlas. Please see the README file for a detailed description of the main and supplementary data.

Capacity Expansion Model↗