Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “numerical modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Comparison of Surface Tension Generation Methods in Smoothed Particle Hydrodynamics for Dynamic Systems

Developing robust numerical models of dynamic surface tension dominated multiphase systems is an ongoing challenge, especially in scenarios with large density and viscosity ratios. This is critical to the design and understanding of various physical and engineering systems, such as fluidized beds, fuel injectors, and drug delivery schemes. Much of the computational work in surface tension dominated multiphase flows has employed the continuum surface force method (CSF) of Brackbill et al. [1], which recasts surface tension from a surface force to a volumetric force that can be imposed in the vicinity of an interface. The CSF method produces accurate results across a variety of systems, however it relies on the identication of surface normals, which can be unreliable under certain conditions. Alternative methods of simulating surface tension have been proposed. Here the advantages and disadvantages of the CSF method in comparison to a pairwise forces (PF) method proposed by Tartakovsky and Panchenko [2] are explored. The CSF and PF methods are used in a smoothed particle hydrodynamics (SPH) framework to model dynamic systems. Results are compared to existing test cases from the literature and to analytic solutions derived from fundamental normal mode behavior of bubbles and droplets. A physical system for which the PF method is more stable and physically appropriate than the CSF method is identied.

smoothed particle hydrodynamics, multiphase flow↗

Numerical framework for integrated additive manufacturing-compression molding (AM-CM) of thermoplastic composites

Additive manufacturing-compression molding (AM-CM) has emerged as a transformative technology in advanced composite manufacturing. Additive manufacturing (AM) offers high design flexibility and the ability to produce complex geometries with precisely aligned fibers in the preferred orientation. Compression molding (CM) enhances composite materials by providing excellent dimensional stability, reduced porosity, high production rates, and a smooth surface finish. Despite these advantages, extensive integrated analysis is required to optimize processing conditions for improved fiber orientation distribution (FOD) and porosity control. Here, this study develops a comprehensive numerical model to simulate the AM-CM manufacturing process. The model isolates the effects of both the AM and CM phases while also capturing their integration. Additionally, it accounts for heat transfer, temperature-dependent viscosity, and fiber orientation in the extruded fiber-filled polymer, accurately representing material behavior during processing. This approach enables the analysis of interactions between deposited beads of complex strand shapes and their interface regions after full compression. Moreover, the model predicts key parameters such as polymer flowability, fiber orientation, and temperature evolution in AM-CM parts. By optimizing processing conditions, it facilitates a controlled and predictable microstructure.

36 MATERIALS SCIENCE↗

Simulation of lithium transport using the BOUT++ framework

A numerical model that calculates the collisional interactions between the lithium atoms from a lithium pellet and the background plasmas has been upgraded. The ion density ($N_t$), electron temperature ($T_e$), ion temperature ($T_i$) and parallel ion velocity ($V_{∥, i}$) are used to characterize the background plasmas. The lithium atom density ($N^{a}_{Li}$) and parallel velocity ($V_{∥,a}$) of lithium atoms evolve with time. For each lithium ion, the density ($N_{Li^{n+}}$), temperature ($T_{Li^{n+}}$) and parallel velocity ($V_{∥, Li^{n+}}$) are self-consistently calculated. A C-mod lower single null equilibrium is used to generate the grid for the BOUT++ simulation. The lithium atoms can be fully ionized to $Li^{3+}$ in ~2 μs. The rapid radial and poloidal expansion of the lithium ions are found in the simulation. After the collision interaction process, the electron temperature rapidly decreases at the pellet location; then, it rapidly poloidally expands, and the temperature at the pellet location starts to recover. The electron pressure increases at the pellet location despite the decrease in electron temperature because of the extra electrons from the lithium ionization. The ion pressure profile decreases in the pellet location due to the decrease in ion temperature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Superhydrophobic composite asymmetric electrospun membrane for sustainable vacuum assisted air gap membrane distillation

Membrane distillation (MD) relies on superhydrophobic membranes that must achieve the competing goals of high liquid entry pressure (LEP) and high permeability. Here, in this study, we developed the first superhydrophobic composite electrospun asymmetric membrane using fluorinated graphite (FG). We also provided among the first comparisons of the relative benefits of membrane asymmetry and composite coatings via 3D electrospinning and spraying. FG particles increased the roughness and reduced the zeta potential of the membranes. Superhydrophobic composite membranes had a contact angle of 157° (sliding angle of 7°) and an LEP of 327 kPa. Long-term MD testing revealed that FG particles could increase MD's sustainability while decreasing membrane wetting. Vacuum-assisted air gap membrane distillation (V-AGMD) showed that the composite asymmetric membrane outperformed the non-asymmetric version (composite nanofiber) membrane by 21 % in average water flux and 25 % in average thermal efficiency because of the asymmetric structure of the membrane. The numerical model developed for the V-AGMD system also successfully predicted the water flux generated experimentally from the composite nanofiber and composite asymmetric membranes. Our results confirmed that electrospun asymmetric FG membranes with high contact angle, low sliding angle, high permeability, and high gained output ratio (GOR) would be promising candidates for sustainable MD.

36 MATERIALS SCIENCE↗

Record-breaking 2020 summer marine heatwaves in the western North Pacific

Record-breaking marine heatwaves (MHWs) occurred in the western North Pacific during the summer of 2020. These unprecedented MHWs were consistent with favorable large-scale conditions that are linked to an anomalous western North Pacific subtropical high (WNPSH), resulting mainly from sea surface temperature (SST) anomalies across the tropical oceans. In addition, a moderate La Niña-like pattern was also conducive to transporting warm seawater to the western North Pacific. Mixed-layer heat budgets suggest that surface heat flux contributed to the SST anomaly in the western subtropical Pacific. In contrast, oceanic heat advection dominanted in the South China Sea and the western equatorial Pacific. Numerical model experiments indicated that the tropical Indian Ocean SST anomalies were responsible for the enhanced WNPSH. The increased zonal SST gradient across the tropical Pacific also played an important role. Inter-ocean interactions can modulate climate variability through ocean-atmospheric coupling and deserve more attention when predicting MHWs within the context of global warming. Additionally, it is critical to consider MHWs as a powerful tool in detecting acute, intense thermal stress events in the coral bleaching pre-warning system.

Coral bleaching↗

Geologic hydrogen: From natural occurrences to anthropogenic generation – A review of fundamentals, potential, challenges and prospects

Growing demand for hydrogen is exposing the environmental and economic limits of reforming-based and carbon-managed supply chains, while the scale-up of electrolytic capacity remains capital-constrained. Geologic hydrogen, defined as molecular H₂ generated and stored within the Earth's crust offers a complementary, potentially lower-cost resource, yet exploration is still ad hoc. This review (1) revisits a global inventory of confirmed hydrogen seeps and subsurface occurrences; (2) analyzes the controlling reactions, migration pathways, and trapping conditions governing these occurrences; (3) proposes a process-based geologic hydrogen system concept analogous to, yet distinct from, the petroleum system; and (4) evaluates potential geologic hydrogen systems within the United States as a representative case study. Here, we contrast natural systems powered by serpentinization, mantle degassing or radiolysis with anthropogenic systems that stimulate the same reactions or convert in-situ hydrocarbons. Stable hydrogen accumulations require generation rates that outpace combined physical, chemical and microbial losses; the Bourakébougou field (Mali) exemplifies a self-recharging, free-gas reservoir sustained by meteoric-water serpentinization beneath an efficient caprock. Prospective geologic hydrogen resources are likely to occur in regions where iron-rich lithologies, deep-seated faults, and low-permeability sealing formations coexist. Applying this principle, we highlight three promising hydrogen play types in U.S. geological terrains: ophiolite belts (Appalachian and Californian regions), the Midcontinent Rift and the Lake Superior banded‑iron formations. Multiphysics numerical models and positive-unlabeled machine-learning workflows help to accelerate play screening and de-risk future production; yet, reaction kinetics, stimulation strategies, and full techno-economic and life-cycle assessments remain pivotal knowledge gaps.

Anthropogenic hydrogen generation↗

Uniform secondary current distribution at disk electrodes under Tafel kinetics enabled by concentric current-shielding rings

Non-uniform secondary current distribution at rotating disk electrodes (RDE) is a common problem when using resistive electrolyte media or large applied currents. In a recent publication, we have shown that auxiliary electrodes such as the ring of a rotating ring disk electrode (RRDE) can help suppress current non-uniformities at the disk enabling reliable electroanalytical measurements. However, this previous work considered linear kinetics where current distribution non-uniformities were moderate. In the present contribution, we consider current distribution non-uniformities encountered under Tafel kinetics. We show, for the case of 2,5-dihydroxy-1,4-benzoquinone (DHBQ) reduction, that optimally chosen ring conditions serve to provide effective shielding at the disk edge rendering the overall disk current distribution to be uniform. Numerical modeling and scaling analysis (using the Wagner number) are presented to aid a user in determining the optimal ring current density for achieving uniform disk current distribution under Tafel kinetics. This approach is especially useful when studying soluble-soluble redox transitions for which, unlike deposit distribution in electrodeposition, the current distribution non-uniformity is not visually apparent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance augmentation of domestic refrigerators with microchannel condensers

Refrigerators are one of the most extensively used household appliances, accounting for approximately 4% of total household electricity consumption. Enhancing their energy performance can significantly reduce residential energy demand. As a result, this study focuses on reducing the energy consumption of a French-door, bottom-mount refrigerator using isobutane (R600a) as the working fluid. Here, the performance improvement of the refrigerators has been obtained mainly through improving the vapor compression refrigeration cycle, with a particular emphasis on condenser design. This study explores the impact of three-pass serpentine microchannel condenser on energy performance, along with the effects of two distinct fan combinations. Charge optimization experiments were conducted to identify the optimal refrigerant mass for the refrigerator unit with microchannel condenser. Additionally, a comprehensive numerical model was developed to analyze the behavior of vapor compression cycle under various refrigerant charges. The experimental findings revealed that the refrigerator unit with the three-pass microchannel condenser reduces the energy consumption of isobutane-based domestic refrigerators up to 16% while reducing the refrigerant charge by 11% in comparison to the refrigerator unit with conventional wire-and-tube condenser.

Charge optimization↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of enhanced CO 2 storage in deep saline aquifers by WAG and brine extraction in the Minnelusa sandstone, Wyoming

Geological CO 2 sequestration in deep saline aquifers has been extendedly investigated to reach the goal of carbon neutral as large amount of CO 2 can be reduced in a short time. Here, this study investigates the feasibility of water-alternating-gas (WAG) injection and brine extraction on enhancing CO 2 storage in a target deep saline aquifer, Minnelusa Sandstone in the Powder River Basin (PRB) of Wyoming. An integrated numerical model is developed to account for four scenarios: (1) CO 2 continuous injection (CI) through one injection well, (2) WAG injection through one injection well, (3) CO 2 CI through one injection well and brine extraction through one producer, (4) WAG injection through one injection well and brine extraction through one producer. Simulation results suggest that WAG injection and brine extraction corporately make it possible to enhance CO 2 injectivity while securing CO 2 storage safety. For instance, WAG injection considerably reduces structural trapping contribution while enhances dissolved and residual trapping contributions. As for brine extraction, it can decrease the maximum averaged reservoir pressure by 37% and 22% for CI and WAG injection, respectively. Besides, sensitive analyses of the operational parameters for the fourth scenarios are performed. Results reveal that, when the amount of total CO 2 injection has been predetermined, CO 2 injection time and rate within each period of WAG should be small whereas it is preferable to have large water injection time and rate. This is to secure desirable dissolved and residual trapping contributions (store CO 2 with safety). Sensitive degree results confirm that CO 2 injection rate, water injection time, and CO 2 injection time of WAG injection exhibit significant effects on CO 2 storage whereas the impacts of producer bottom-hole pressure (BHP), water injection rate, and CO 2 -water injection time are relatively weaker. This study not only sheds light on achieving double-win goal: enhance CO 2 injectivity and store CO 2 with safety, but also can be a critical reference for other CO 2 storage in deep saline aquifers.

58 GEOSCIENCES↗

Thermal energy storage in concrete utilizing a thermosiphon heat exchanger

The performance of a lab-scale concrete thermal energy storage (TES) module with a 2-kWh thermal capacity is evaluated at temperatures up to 400 °C. The TES module uses conventional normal weight concrete with thermal and mechanical properties that are tailored for use as a solid thermal energy storage media. A thermosiphon heat exchanger is used to provide rapid heat transfer into the concrete module, which is reinforced with a steel pipe outer shell. The charging and discharging cycles are examined to assess the thermal performance of the concrete and thermosiphon. Based on the results of testing, the thermosiphon is able to repeatably charge the concrete module from 300 to 400 °C over a 4-h period. After 2250 total hours of charge and discharge cycles, there was no observed delamination between the concrete and the thermosiphon or the steel jacket reinforcement. Non-destructive measurements of the concrete indicated no significant degradation of the solid storage media. The experimental results are then used to validate a numerical model of the concrete TES module for parametric study. Finally, varying insulation conditions were analyzed using this model to determine practical configurations for regular operation of the proposed concrete TES module.

25 ENERGY STORAGE↗

System efficiency of packed bed TES with radial flow vs. axial flow – Influence of aspect ratio

Here, this paper compares the net system efficiency, including thermal efficiency and pressure drop effects, of radial versus axial flow packed beds for thermal energy storage. The traditional packed bed system is a cylindrical geometry where fluid flows axially from one end to another. However, issues of thermal stratification and high-pressure drop have led to recent studies on radial flow systems. One potential benefit is the reduced pressure drop in a radial flow system. This paper compares the performance of radial flow and axial flow systems at a range of aspect ratios (AR = H/D bed ) from 0.21 to 1.92 using a numerical model where the storage volume is held constant in all cases. When the radial flow bed is at a low aspect ratio (short/wide), the thermal front is improved but the pressure drop is high. At a high aspect ratio, the velocity is reduced in radial flow, leading to decreased pressure drop but an increased spreads in the thermal front that lowers thermal efficiency. The opposite trends are noted in axial flow. Thermal efficiencies of 83–91 % were noted for radial flow, while they ranged from 85 to 94 % in axial flow. Net efficiencies including pressure drop ranged from 74 to 82 % for radial flow and 80–87 % for axial flow. In both systems, a peak net efficiency was noted between the highest and lowest aspect ratio. While some aspect ratios with radial flow outperform axial flow from a net efficiency perspective, the results show that the highest net efficiency from axial flow is higher than that from radial flow. Overall, this paper highlights the importance of innovative TES designs and their potential to improve energy efficiency.

25 ENERGY STORAGE↗

Experimental and numerical investigation of proppant embedment and conductivity reduction within a fracture in the Caney Shale, Southern Oklahoma, USA

The current worldwide energy supply is insufficient to meet the rising demand. As a result, the energy prices are expected to keep soaring despite the recent increases in a variety of renewable energy resources. Although not renewable, shale oil and gas — “unconventional” hydrocarbon resources are relatively clean forms of energy resources, which still hold a vast share of the energy market. For many oil and gas companies, meeting profitable production goals from shale reservoirs is sometimes challenging, due to the loss of fracture conductivity and premature declines in the production. In this paper we investigate the stress-dependent changes in the hydraulic conductivity of proppant-filled fractures and mechanical fracture–proppant interactions in Caney Shale, a calcareous, organic-rich mudrock, through laboratory experiments and numerical modeling. American Petroleum Institute (API) fracture conductivity tests were conducted using 2% KCl on five locations within the Caney Shale that consisted of selecting three brittle (reservoir) zones and two ductile zones. Confining pressures ranged from 1,000 psi to 12,000 psi at 210 °F. Conductivity, permeability as well as embedment were measured during the test. Also, an additional, laboratory in-situ visualization test was conducted to examine the detailed proppant-shale matrix interaction under elevated stress (3,920 psi effective stress) and temperature (252 °F), with a synthetic reservoir fluid. Our experimental results have confirmed that improved fracture conductivity is attributed to proppant size, and that the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress.

04 OIL SHALES AND TAR SANDS↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing the efficacy of active pressure management as a tool to mitigate induced seismicity

Manipulation of subsurface stresses through fluid injection/extraction may induce seismicity through modulation of overpressure along faults. Globally, most industrial operations do not induce significant earthquakes. However, the possibility of inducing moderate to large earthquakes is recognized as a significant risk for basin-scale carbon dioxide (CO 2 ) storage operations (Niass et al., 2017). One possible method to reduce the occurrence of induced seismicity is to maintain only small (or zero) fluid overpressure changes in the subsurface through extraction of formation brine. For active pressure management (APM), operators may employ different procedures including extraction of various brine volumes and different configurations of injection/extraction well locations. However, the impact each these operational procedures on induced seismicity must be understood in order to develop management strategies. Here, we describe a numerical modeling workflow to evaluate the efficacy of APM techniques, that when applied to a specific site may be used to inform operational management strategies. We couple the multiphase reservoir model, NUFT, with the earthquake simulator, RSQSim and simulate seismicity induced by CO 2 injection into a hypothetical brine saturated reservoir. Reservoir overpressure is modified by co-extraction of brine at various fractions of the injected CO 2 volume from five potential wells. Our goal is to understand how the well-pair configuration and the extracted brine volume impact the total number and the maximum event magnitude. Additionally, the performance of each scenario is also evaluated in terms of the volume of CO 2 that can be stored before an earthquake above a tolerance threshold is induced.

58 GEOSCIENCES↗

An assessment of controlled source EM for monitoring subsurface CO 2 injection at the wyoming carbonSAFE geologic carbon storage site

Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.

58 GEOSCIENCES↗

Experimental measurements of fluid flow in an 84-pin hexagonal rod bundle with spacer grid for a gas-cooled fast modular reactor

A 50 MW e helium-cooled fast modular reactor (FMR) is under development, and as part of the Department of Energy Integrated Research Project (IRP), Texas A&M University is conducting the thermal-hydraulic characterization of its baseline core configuration. Here, we experimentally investigated the axial and cross flow fields characteristics in the hexagonal fuel rod bundle composed of 84 rods, a central rod, and spacer grids at a Reynolds number of 12,000. A fully transparent experimental facility resembling of one unit of the fuel assembly was constructed. Time-resolved particle image velocimetry (TR-PIV) measurements were performed to characterize hydraulic behavior downstream the spacer grid. Velocity measurements were conducted in the axial and radial direction of the rod bundle. From the PIV velocity vector fields, the full-field flow statistics were computed for the mean velocity, vorticity, and Reynolds stresses. An analysis of the energy decay downstream of the spacer grid was conducted with calculations of secondary-flow intensities, turbulent kinetic energy, power spectrum, and spatial-temporal velocity cross correlations. The vorticity field was obtained and pairs of counter-rotating vortexes were identified using a 3D reconstruction of several measurement planes. The data from this experimental campaign will be used to validate numerical models based on Computational Fluid Dynamics and other codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗