Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A Cold Moderator For Sub-Thermal Neutron Flux Enhancement at the RPI-LINAC

The importance of high-quality thermal neutron scattering kernels coupled with a lack of accurate sub-thermal total cross section data prompted researchers at Rensselaer Polytechnic Institute (RPI) to design a cold moderation system to enhance sub-thermal neutron flux (defined as flux below 5 meV), for nuclear data measurements at the RPI Gaerttner LINAC facility. Using a series of neutronic and heat transfer simulations obtained with MCNP and COMSOL, an optimized final design was produced. The final design exceeded current target sub-thermal neutron producing capabilities by a factor of 8 in the sub-thermal region and is easily configurable with existing neutron producing targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sandia 7uPCX Critical Experiments Exploring the Effects of Fuel-to-Water Ratio Variations

The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The LEUCOMP-THERM-078 and LEU-COMP-THERM-080 evaluations from the handbook provide similar cases for reference. The set of experiments described here were performed using the Seven Percent Critical Experiment (7uPCX) fuel to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by using fuel loading patterns to effectively increase the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva Experiments for the Nuclear Criticality Safety Program (NCSP)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5 percent molybdenum for strength. Godiva is one of the last such critical assemblies in the United States, and can be used for studies of super-prompt critical behavior as well as irradiations and demonstrations. A demonstration of a Godiva burst is usually performed as a highlight of the hands-on portion of the Criticality Safety Training Classes taught at the National Criticality Experiment Research Center (NCERC). The Godiva burst is used to demonstrate the concept of super-prompt critical and the time-scale of a criticality accident. In addition, several NCSP projects have been conducted on Godiva IV over the past two years. One experiment focused on collecting data to support multiphysics simulations using Photo-Doppler Velocimetry (PDV) to measure surface movement and gamma detectors to measure the burst output as the burst develops from background to peak over ten orders of magnitude. Another experiment was performed to demonstrate the functionality of the Criticality Accident Alarm System (CAAS) system developed for installation in the Y-12 Uranium Processing Facility (UPF). The system must not only respond to a criticality event and alarm, but must also be shown to operate in a high dose environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seeing through nuclear fuel: Three-dimensional, nondestructive X-ray microscopy and volumetric analyses of neutron-irradiated TRISO-coated fuel kernels

The three-dimensional (3D) characterization of nuclear fuel with X-ray microscopy has historically proven difficult, due to uranium’s high attenuation of easily accessible X-rays, both in a laboratory setting and at a synchrotron user facility. However, this imaging modality provides nondestructive information that can be used to investigate morphological changes arising from external stimuli (e.g., neutron irradiation, high-temperature testing). Using an appropriate X-ray energy spectrum and an adequate X-ray filter, suitable transmissions through properly sized nuclear fuel specimens can be achieved. Here, in this study, we present the methods and results of using a commercially available, laboratory-based X-ray microscope (XRM) to examine the extent of 3D morphological changes of tristructural isotropic (TRISO)-coated fuel particles, specifically uranium oxide/uranium carbide fuel kernels, after high-temperature neutron irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online and Offline Monitoring of the ICARUS Detector

In preparation for the launch of the ICARUS -T600 far detector in the Short Baseline Neutrino program, (SBN), it is important to monitor the performance of the detector and quality of the data in real-time. Particularly important to monitor are noise levels of the TPC readout electronics, and the purity of the liquid argon in the TPC, as these can affect the overall sensitivity of the detector to detecting and reconstructing neutrino interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) LNK3DNT Capability in SENSMG Tested with Transport Correction

The SENSMG multigroup neutron sensitivity code can read materials and geometry from redoin and lnk3dnt files written by the PARTISN multigroup discrete ordinates code or the MCNP6 Monte Carlo code. Reference 5 described an initial version of this capability. Reference 6 introduced two important extensions: 1) Reaction-rate ratios are now allowed as responses with redoin/lnk3dnt inputs; and 2) Sensitivities of reaction-rate ratios to mass densities and interface locations are now calculated (for all problems, not just redoin/lnk3dnt problems). In this report, we document the testing of the redoin/lnk3dnt capability when used with transport correction. PARTISN’s transport corrections are described in Ref. 3, and Refs. 7 and 8 discuss the calculation of cross-section sensitivities when transport corrections are applied. References 7 and 8 verify SENSMG for problems with transport correction using central differences. This report verifies the capability with redoin/lnk3dnt inputs by comparison with regular SENSMG inputs. Unlike Refs. 5 and 6, in this report we use a spherical test problem because the sensitivity of the response with respect to the highest-order scattering is zero in cylinders due to the use of flux moments in the inner products.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MHD-240 Neutron Detection Efficiency and Sensitivity Calibration

The neutron detection efficiency of the MHD-240 scintillation detector was measured at Ohio University Edwards Accelerator Laboratory. Pulsed broad-spectrum sources from the 27 Al(d,n) and 9 Be(d,n) reactions were used to produce the neutrons. The neutron time-of-flight technique was used to make an energy-differential efficiency measurement. The measurements were made in a low rate pulse mode. The pulse height distribution was also recorded, and the data were used to derive a neutron sensitivity that would be applicable in a high rate environment such as a critical assembly where the detector would be expected to operate in a current mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive Assay for Nuclear Safeguards [Slides]

The objective of safeguards is the timely detection of diversion of significant quantities of nuclear material from peaceful nuclear activities to the manufacture of nuclear weapons. Currently, the IAEA is working to achieve universal acceptance of the AP, safeguards-by-design, unattended monitoring & data integration, and state-level concept/approach. We are trying to verify special nuclear material (SNM) is where it should be, and in the proper amount.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of γ-ray branching ratios for ⁹⁵Zr and ¹⁴⁷Nd

For many fission products, the γ rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields (FPYs), provided sufficiently accurate information on the γ-ray branching ratio is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure the γ-ray branching ratios in the decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β -decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the γ-ray branching ratios of the strongest transitions following the decay of ⁹⁵Zr and decay-daughter ⁹⁵Nb and determined these branching ratios to fractional precisions of 1%. We then applied this approach to determine the γ-ray branching ratios for the β decay of ¹⁴⁷Nd. The results for the γ-ray branching ratios are presented here and compared to previous results and evaluations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗