Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Fatigue Analyses Under Constant- and Variable-Amplitude Loading Using Small-Crack Theory

Studies on the growth of small cracks have led to the observation that fatigue life of many engineering materials is primarily "crack growth" from micro-structural features, such as inclusion particles, voids, slip-bands or from manufacturing defects. This paper reviews the capabilities of a plasticity-induced crack-closure model to predict fatigue lives of metallic materials using "small-crack theory" under various loading conditions. Constraint factors, to account for three-dimensional effects, were selected to correlate large-crack growth rate data as a function of the effective stress-intensity factor range (delta-Keff) under constant-amplitude loading. Modifications to the delta-Keff-rate relations in the near-threshold regime were needed to fit measured small-crack growth rate behavior. The model was then used to calculate small-and large-crack growth rates, and to predict total fatigue lives, for notched and un-notched specimens under constant-amplitude and spectrum loading. Fatigue lives were predicted using crack-growth relations and micro-structural features like those that initiated cracks in the fatigue specimens for most of the materials analyzed. Results from the tests and analyses agreed well.

Newman, J. C., Jr.↗

An Analysis on Cost Reduction Potential of Vertical Bore Ground Heat Exchangers Used for Ground Source Heat Pump Systems

The cost for installing ground heat exchangers (GHXs) used for ground source heat pump (GSHP) systems usually accounts for more than 30% of the total cost of a GSHP system and it is the biggest contributor to the cost premium of GSHPs compared with conventional HVAC systems. This study evaluates the cost reduction potential of several possible improvements in borehole heat transfer and bore field layout. A detailed cost model for GHX installation was updated and new features were added to account for various GHX designs, geological conditions, and drilling technologies. Coupled with a well-established GHX sizing program, a systematic study was conducted to assess the impacts of these improvements on the needed total drilling length and resulting cost under various geological and loading conditions. Finally, improvements with significant potential to reduce GHX installation cost are recommended.

Liu, Xiaobing↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗

Field Test of Boiler Primary Loop Temperature Controller

Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonproportional loading limit for structures

The design of most structures involves ensuring integrity for several independent loading conditions. Often, it is rational to design these, exploiting the ductility of the materials to reduce structural costs. Then, ensuring integrity evokes the need for nonmonotonic limit analyses. A groundwork is laid for implementing these analyses. An alternate limit load characterization to that of Greenberg is provided, a mathematical statement of the problem leading to both monotonic (proportional) and nonmonotonic limit loads values is formulated, a direct limit load analysis procedure for analysis within a finite-element framework is described, and limit loads for sets of simple structures are evaluated. A direct limit analysis process is described, and monotonic limit loads are characterized. The process furnishes 'exact' values of limit loads with increasing efficiency as the number of structural elements and force redundancy decreases. Tests show that the accuracy of predicting nonmonotonic limit loads is very sensitive to the number of degrees of freedom in the analysis compared with the total number in the model.

Melosh, R. J.↗

Study leading to the refinement of the SRB structural analysis program

The constructed SRB math model was used for the analysis of the 85/32/5(VV/VH/theta) cavity collapse load condition for the aft end of the SRB structure. Linear, nonlinear collapse and bifurcation buckling analyses were performed. The linear and bifurcation buckling analyses showed that structural integrity and positive margins of safety are maintained for the applied maximum load case using a design factor of 1.25. The nonlinear collapse analysis predicts stresses in the skirt above the yield for a load factor of 1.0. Applying the 1.25 design factor gives a negative margin of safety against the material ultimate. The predicted collapse occurs at a load factor higher than 1.25.

Jones, W. E.↗

Control Augmented Structural Synthesis

A methodology for control augmented structural synthesis is proposed for a class of structures which can be modeled as an assemblage of frame and/or truss elements. It is assumed that both the plant (structure) and the active control system dynamics can be adequately represented with a linear model. The structural sizing variables, active control system feedback gains and nonstructural lumped masses are treated simultaneously as independent design variables. Design constraints are imposed on static and dynamic displacements, static stresses, actuator forces and natural frequencies to ensure acceptable system behavior. Multiple static and dynamic loading conditions are considered. Side constraints imposed on the design variables protect against the generation of unrealizable designs. While the proposed approach is fundamentally more general, here the methodology is developed and demonstrated for the case where: (1) the dynamic loading is harmonic and thus the steady state response is of primary interest; (2) direct output feedback is used for the control system model; and (3) the actuators and sensors are collocated.

Lust, Robert V.↗

SSME HPFTP/AT Turbine Blade Platform Featherseal Damper Design

During the Space Shuttle Main Engines (SSM) HPFtP/AT development program, engine hot fire testing resulted in turbine blade fatigue cracks. The cracks were noted after only a few tests and a several hundred seconds versus the design goal of 60 tests and >30,000 seconds. Subsequent investigation attributed the distress to excessive steady and dynamic loads. To address these excessive turbine blade loads, Pratt & Whitney Liquid Space Propulsion engineers designed and developed retrofitable turbine blade to blade platform featherseal dampers. Since incorporation of these dampers, along with other turbine blade system improvements, there has been no observed SSME HPFTP/AT turbine blade fatigue cracking. The high time HPFTP/AT blade now has accumulated 32 starts and 19,200 seconds hot fire test time. Figure #1 illustrates the HPFTP/AT turbine blade platform featherseal dampers. The approached selected was to improve the turbine blade structural capability while simultaneously reducing loads. To achieve this goal, the featherseal dampers were designed to seal the blade to blade platform gap and damp the dynamic motions. Sealing improves the steady stress margins by increasing turbine efficiency and improving turbine blade attachment thermal conditioning. Load reduction was achieved through damping. Thin Haynes 188 sheet metal was selected based on its material properties (hydrogen resistance, elongation, tensile strengths, etc.). The 36,000 rpm wheel speed of the rotor result in a normal load of 120#/blade. The featherseals then act as micro-slip dampers during actual SSME operation. After initial design and analysis (prior to full engine testing), the featherseal dampers were tested in P&W's spin rig facility in West Palm Beach, Florida. Both dynamic strain gages and turbine blade tip displacement measurements were utilized to quantify the featherseal damper effectiveness. Full speed (36,000 rpm), room temperature rig testing verified the elimination of fundamental mode (i.e, modes 1 & 2) resonant response. The reduction in turbine blade dynamic response is shown for a typical turbine blade. This paper discusses the design and verification of these dampers. The numerous benefits associated with this design concept warrants consideration in existing and future turbomachinery applications.

Montgomery, S. K.↗

Analyses of Fatigue and Fatigue-Crack Growth under Constant- and Variable-Amplitude Loading

Studies on the growth of small cracks have led to the observation that fatigue life of many engineering materials is primarily crack growth from micro-structural features, such as inclusion particles, voids, slip-bands or from manufacturing defects. This paper reviews the capabilities of a plasticity-induced crack-closure model to predict fatigue lives of metallic materials using small-crack theory under various loading conditions. Constraint factors, to account for three-dimensional effects, were selected to correlate large-crack growth rate data as a function of the effective stress-intensity factor range (delta K(sub eff)) under constant-amplitude loading. Modifications to the delta K(sub eff)-rate relations in the near-threshold regime were needed to fit measured small-crack growth rate behavior. The model was then used to calculate small- and large-crack growth rates, and to predict total fatigue lives, for notched and un-notched specimens under constant-amplitude and spectrum loading. Fatigue lives were predicted using crack-growth relations and micro-structural features like those that initiated cracks in the fatigue specimens for most of the materials analyzed. Results from the tests and analyses agreed well.

Newman, J. C., Jr.↗

Handbook on dynamics of jointed structures.

The problem of understanding and modeling the complicated physics underlying the action and response of the interfaces in typical structures under dynamic loading conditions has occupied researchers for many decades. This handbook presents an integrated approach to the goal of dynamic modeling of typical jointed structures, beginning with a mathematical assessment of experimental or simulation data, development of constitutive models to account for load histories to deformation, establishment of kinematic models coupling to the continuum models, and application of finite element analysis leading to dynamic structural simulation. In addition, formulations are discussed to mitigate the very short simulation time steps that appear to be required in numerical simulation for problems such as this. This handbook satisfies the commitment to DOE that Sandia will develop the technical content and write a Joints Handbook. The content will include: (1) Methods for characterizing the nonlinear stiffness and energy dissipation for typical joints used in mechanical systems and components. (2) The methodology will include practical guidance on experiments, and reduced order models that can be used to characterize joint behavior. (3) Examples for typical bolted and screw joints will be provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demand Response Potential for California SubLAPs and Local Capacity Planning Areas: An Addendum to the 2025 California Demand Response Potential Study – Phase 2

The 2025 California Demand Response Potential Study Phase 2 Report1 was released on March 1, 2017, and described a range of pathways for Demand Response (DR) to support a clean, stable, and cost-effective electric grid for California. One of the Report’s key findings was that while there appears to be very low future value for untargeted DR Shed aimed at system-wide peak load conditions, there could be significant value for locally focused Shed resources. Although the dynamics of renewable capacity expansion have reduced the pressure to build new thermal generation in general, there are still transmission-constrained areas of the state where load growth needs to be managed with the addition of new local capacity, which could include DERs and/or DR. This Addendum to the Phase 2 Report presents a breakdown of the expected future “Local Shed” DR potential at a finer geographic resolution than what is available in the original report, with results summarized by SubLAP and Local Capacity Area (LCA).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A summary of the Hanford single-shell tank structural analysis of record - 15526

Washington River Protection Solutions, LLC (WRPS), the US DOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009 to better understand the integrity of the single-shell tanks (SSTs). A panel of experts from industry and academia was created to recommend project activities in four main areas: structural integrity, liner degradation, leak integrity and prevention, and contamination migration. One of the panel's primary recommendations was to perform a detailed structural integrity analysis of the SSTs. WRPS and the U.S. Department of Energy, Office of River Protection commissioned the Pacific Northwest National Laboratory (PNNL) to perform this structural integrity analysis of record for the Hanford single shell tanks. This is one of seventeen panel recommendations that form the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order; also known as the Tri-Party Agreement. Finite element analysis was used to predict the structural response of the SSTs to the historical thermal and operating loads, plus design basis seismic loads. Bounding thermal histories were established from waste temperature records and applied to the model to include the thermal degradation of concrete modulus and strength, plus cracking due to differential thermal expansion while under in situ static loading conditions. PNNL contracted with Becht Engineering to evaluate the dynamic response of the tanks to a design basis earthquake. The degraded stiffness of the reinforced concrete was also incorporated in the seismic analysis. The combined response to static and seismic loads was then evaluated against the design requirements of the American Concrete Institute standard, ACI-349-06, for nuclear safety-related concrete structures. Specific analyses were performed for the four major tank designs.This paper presents an overview of the analysis methods used and it summarizes the major analytical findings that are common to the tanks and others that are specific to the individual tank designs. The analyses of record determined that including the bounding effects of their operating histories, each tank design currently satisfies the ACI-349-06 structural integrity design requirements. Although leak tightness is not directly addressed in the structural integrity analysis, this analysis will be a key input in the formal tank integrity assessment due in 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cumulative Axial and Torsional Fatigue: An Investigation of Load-Type Sequencing Effects

Cumulative fatigue behavior of a wrought cobalt-base superalloy, Haynes 188 was investigated at 538 C under various single-step sequences of axial and torsional loading conditions. Initially, fully-reversed, axial and torsional fatigue tests were conducted under strain control at 538 C on thin-walled tubular specimens to establish baseline fatigue life relationships. Subsequently, four sequences (axial/axial, torsional/torsional, axial/torsional, and torsional/axial) of two load-level fatigue tests were conducted to characterize both the load-order (high/low) and load-type sequencing effects. For the two load-level tests, summations of life fractions and the remaining fatigue lives at the second load-level were computed by the Miner's Linear Damage Rule (LDR) and a nonlinear Damage Curve Approach (DCA). In general, for all four cases predictions by LDR were unconservative. Predictions by the DCA were within a factor of two of the experimentally observed fatigue lives for a majority of the cumulative axial and torsional fatigue tests.

Kalluri, Sreeramesh↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

Intense cyclic heating effects on thermo-fracture and thermal shock of solid tungsten and open-cell tungsten foam

Here we investigate here the effects of transient (cyclic) arc-jet plasma and laser heating on fracture behavior of W-foam and solid tungsten. The two key parameters that control the foam thermomechanical response are its density and mean cell size expressed in Pores Per Inch (PPI). Tungsten foam samples were fabricated with Chemical Vapor Deposition (CVD) with variety of PPI and relative density. These were tested under two types of qualitatively different conditions: (1) high-enthalpy arc-jet, and (2) high-power cyclic laser heating. None of the foam samples showed macroscopic through-thickness cracks. However, distributed micro-cracks were observed on ligaments and their triple junctions. Under the same loading conditions, W-foam and solid tungsten showed similar crack network pattern and characteristic length-scale. However, Crack Opening Displacement (COD) was twice as large in solid W as compared to W-foam. Foam samples that have been previously exposed to a low-pressure helium plasma showed significant changes in their surface forming nano-texture fuzz which was removed by subsequent testing in the arc-jet. Extensive fracture and re-crystallization were observed in the thin solid W disk that was fully-constrained from expansion. Thicker and fully-constrained solid W disks did not display recrystallization, grain growth, and extensive cracking. However, thicker disks that were free to expand showed some recrystallization and extensive through-thickness cracks due to less effective cooling and thus higher temperatures. Laser beam testing showed no visible damage formation at 0.19 GW/m 2 and 0.38 GW/m 2 for both low-density (23%) and high-density (43%) foams at low pulses (100-1000). Micro-cracks were observed after 10,000 pulses at 0.19 GW/m 2 in both foams, and in low-density foam after 100,000 at 0.38 GW/m 2 . The nature of thermomechanical damage in W-foam exposed to extreme power (GW/m 2 ) short-duration laser pulses was found to be qualitatively similar to that of high power (MW/m 2 ) long-duration arc-jet.

36 MATERIALS SCIENCE↗

Heat sink structural design concepts for a hypersonic research airplane

Hypersonic research aircraft design requires careful consideration of thermal stresses. This paper relates some of the problems in a heat sink structural design that can be avoided by appropriate selection of design options including material selection, design concepts, and load paths. Data on several thermal loading conditions are presented on various conventional designs including bulkheads, longerons, fittings, and frames. Results indicate that conventional designs are inadequate and that acceptable designs are possible by incorporating innovative design practices. These include nonintegral pressure compartments, ball-jointed links to distribute applied loads without restraining the thermal expansion, and material selections based on thermal compatibility.

Taylor, A. H.↗

Dynamic and Flight Tests on Rubber-Cord and Oleo-Rubber-Disk Landing Gears for an F6C-4 Airplane

The investigation described in this report was conducted for the purpose of comparing an oleo-rubber-disk and a rubber-cord landing gear, built for use on an F6C-4 airplane. The investigation consisted of drop tests under various loading conditions and flight tests on an F6C-4 airplane. In the drop tests the total work done on each gear and the work done on each of the shock-absorbing units were determined. For both drop tests and flight tests the maximum loads and accelerations were determined. The comparative results showed that the oleo gear was slightly superior in reducing the ordinary landing shocks, that it had a greater capacity for work, and that it was very superior in the reduction of the rebound. The results further showed that for drops comparable to very severe landings, the rubber-cord gear was potentially more effective as a shock-reducing mechanism. However, due to the construction of this chassis, which limited the maximum elongation of the cords, this gear was incapable of withstanding as severe tests as the oleo gear. The action of the oleo gear was greatly inferior to the action of an ideal gear. The maximum accelerations encountered during the flight tests for severe landings were 3.64g for the rubber-cord gear and 2.27g for the oleo gear. These were less than those experienced in free drops of 7 inches on either gear.

Peck, William C↗

A concurrent irradiation-mechanics multiscale coupling model

The vast majority of our current knowledge regarding the basic mechanisms controlling irradiation effect on mechanical properties is based almost entirely on the results of post-irradiation experiments or theoretical models. However, the concurrent effects of irradiation, mechanical stress, and thermal damage on the failure phenomena of materials and components remain largely unexplored due to its internal multiscale-multiphysics coupling nature. Here, we present here a concurrent irradiation-mechanics multiscale coupling model. The concurrent evolutions of nanoscale irradiation defect clusters, microscale dislocation configurations, and mechanical responses are well captured based on coupling cluster dynamics, discrete dislocation dynamics, and the finite element methods using an effective time marching scheme. Model predictions of defect densities and size are in general agreement with experimental observations. Irradiation hardening is shown to take place also in samples undergoing concurrent irradiation-mechanical loading, similar to samples tested post-irradiation. However, the occurrence of plastic flow localization and dislocation channel formation is not accompanied with apparent yield drop (softening) under concurrent irradiation-mechanical loading conditions, which is different from the post-irradiation case.

42 ENGINEERING↗