Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Distribution Substation Planning Toolkit (dsp-toolkit) v1.0

The Distribution Substation Planning Toolkit (DSP Toolkit) is a software suite designed to streamline the planning and optimization of distribution substations. This toolkit offers a comprehensive set of tools and APIs for data curation, short-term electric load forecasting, and weather-sensitive load adjustment, making it an essential resource for utility companies, engineers, and researchers. Features • Data Preprocessing and Curation: Efficiently manage and preprocess large datasets to ensure high-quality input for analysis. • Short-Term Load Forecasting: Utilize data-driven models to predict short-term electric loads accurately. • Weather-Sensitive Modeling: Automatically adjust load forecasts based on weather data to predict future peak demands more precisely. Uses The DSP Toolkit is ideal for planning and optimizing distribution substations, providing a user-friendly interface and comprehensive documentation. It is suitable for both novice and experienced users, facilitating efficient and accurate planning processes. Advantages • Efficiency: Automates complex planning tasks, reducing manual effort and minimizing errors. • Scalability: Handles large datasets and complex models, making it suitable for large-scale projects. • Community and Support: Open-source with active community contributions, ensuring continuous improvement and support. • Extensibility: Easily extendable with custom modules and plugins, allowing users to tailor the toolkit to their specific needs. The DSP Toolkit stands out by offering a robust, flexible, and user-friendly solution for distribution substation planning. Public Abstract

Li, Han [Lawrence Berkeley National Laboratory (LB↗

NILM Applications for the Energy-Efficient Home

We present a forecast for systems-focused applications of non-intrusive load monitoring (NILM), which meet the needs of homeowners, the technology sector, the service sector, and/or utilities. We discuss both near- and long-term applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

Ghosh, Soumyadip↗

Data-Driven Network Reduction and Aggregation with DERs for Outage Management

A novel approach exploiting the growing number of Distributed Energy Resources (DERs) to enhance distribution system resiliency is presented. After a power outage, DERs and loads are aggregated into switch-level equivalent models, preserving, at the same time, controllability information to enable real-time outage management analysis. Pre-fault smart-meters measurements are used as inputs for Artificial Neural Networks and Cold Load Pick-Up (CLPU) modeling to obtain short-term load forecast, while an optimal restoration analysis is carried out to determine restored network topology and utility-controlled loads and DERs set-points

Menazzi, Matteo↗

Advances in Glass Formulations for Hanford High-Alumimum, High-Iron and Enhanced Sulphate Management in HLW Streams - 13000

The current estimates and glass formulation efforts have been conservative in terms of achievable waste loadings. These formulations have been specified to ensure that the glasses are homogenous, contain essentially no crystalline phases, are processable in joule-heated, ceramic-lined melters and meet Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract terms. The WTP?s overall mission will require the immobilization of tank waste compositions that are dominated by mixtures of aluminum (Al), chromium (Cr), bismuth (Bi), iron (Fe), phosphorous (P), zirconium (Zr), and sulphur (S) compounds as waste-limiting components. Glass compositions for these waste mixtures have been developed based upon previous experience and current glass property models. Recently, DOE has initiated a testing program to develop and characterize HLW glasses with higher waste loadings and higher throughput efficiencies. Results of this work have demonstrated the feasibility of increases in waste loading from about 25 wt% to 33-50 wt% (based on oxide loading) in the glass depending on the waste stream. In view of the importance of aluminum limited waste streams at Hanford (and also Savannah River), the ability to achieve high waste loadings without adversely impacting melt rates has the potential for enormous cost savings from reductions in canister count and the potential for schedule acceleration. Consequently, the potential return on the investment made in the development of these enhancements is extremely favorable. Glass composition development for one of the latest Hanford HLW projected compositions with sulphate concentrations high enough to limit waste loading have been successfully tested and show tolerance for previously unreported tolerance for sulphate. Though a significant increase in waste loading for high-iron wastes has been achieved, the magnitude of the increase is not as substantial as those achieved for high-aluminum, high-chromium, high-bismuth or sulphur. Waste processing rate increases for high-iron streams as a combined effect of higher waste loadings and higher melt rates resulting from new formulations have been achieved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Agent-based microgrid architecture for generation following protocols

A system for predicting power and loads over a single, relatively short time horizon. More specifically, a system comprising a Storage Agent (S-agent) Cohort within a grid control society, wherein the system expands G and L intra-cohort protocols to allow the S-cohort to participate in power management of the grid by scheduling storage components in source or load roles as determined by the time-varying state of the power imbalance and by the risk-adjusting capacity margin relationship between the G and L cohorts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NRIC Final Water Management Options

The purpose of this paper is to inform advanced reactor developers of the conditions and requirements needed to manage the water used to reject heat from advanced reactor demonstrations at the INL. While there are many advanced reactor concepts, all of them require heat rejection, and some plan to use water for hear rejection. Cooling water for heat rejection is frequently the largest fresh-water load for a nuclear reactor, and therefore the focus of water management. The type of reactor and its purpose, the physical conditions at the INL, and the regulatory structure of the demonstration also influence the optimal method of heat rejection. Choosing the best method of rejecting heat will significantly influence the cost and probability of success for any advanced reactor demonstration. One of the important considerations in the deployment of demonstration plants at the INL site is water use and its implications. Advanced reactor developers need to consider the limitations of the water consumption based on the state and federal regulations. The water consumption may become a limitation when the demonstration reactor capacities reach to conventional nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Efficient Heterogeneous Execution on Large Multicore and Accelerator Platforms: Case Study Using a Block Tridiagonal Solver

The algorithmic and implementation principles are explored in gainfully exploiting GPU accelerators in conjunction with multicore processors on high-end systems with large numbers of compute nodes, and evaluated in an implementation of a scalable block tridiagonal solver. The accelerator of each compute node is exploited in combination with multicore processors of that node in performing block-level linear algebra operations in the overall, distributed solver algorithm. Optimizations incorporated include: (1) an efficient memory mapping and synchronization interface to minimize data movement, (2) multi-process sharing of the accelerator within a node to obtain balanced load with multicore processors, and (3) an automatic memory management system to efficiently utilize accelerator memory when sub-matrices spill over the limits of device memory. Results are reported from our novel implementation that uses MAGMA and CUBLAS accelerator software systems simultaneously with ACML for multithreaded execution on processors. Overall, using 940 nVidia Tesla X2090 accelerators and 15,040 cores, the best heterogeneous execution delivers a 10.9-fold reduction in run time relative to an already efficient parallel multicore-only baseline implementation that is highly optimized with intra-node and inter-node concurrency and computation-communication overlap. Detailed quantitative results are presented to explain all critical runtime components contributing to hybrid performance.

Park, Alfred J↗

S-Hybrid Step-Down DC-DC Converter-Analysis of Operation and Design Considerations

This paper presents a new highly integrable hybrid step-down converter that merges switched-inductor (SI) and switched-capacitor (SC) operations and significantly reduces onboard loss by using the input cable's parasitic inductance as its main inductor. This converter has the inductor placed at the input with a smaller voltage swing, leading to possible use of a smaller inductor and low-voltage rating switches that generally translate to reduced conduction losses. Analyses of converter operation and losses to reveal its original characteristics and design guidelines are presented to facilitate the components optimization. The converter architecture is verified by a proof-of-concept 15-W inductor-less lithium-ion battery charger prototype that uses a 1-m USB 3.0 cable as inductor. The converter, switched at 2 MHz from a 5-V input, experimentally achieves 89.7% peak efficiency and 6% higher efficiency at full load than a Buck converter counterpart. This high efficiency and zero onboard inductor yield a relative 45.7% onboard loss reduction at full load, promising excellent integration feasibility and superior system thermal management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Lifecycle Framework

The Battery Lifecycle (BLC) Framework is an open-source platform that provides tools to visualize and share battery data from material characterization, cell testing, manufacturing, and field testing through the technology development cycle. BLC has three components: data importers, a front-end for querying the data and creating visualizations, and an application programming interface to provide access to the data from Python. BLC has been deployed for tracking the development of a battery from the lab to a manufacturing line and systems installed in the field and for comparing studies of multiple cells of the same battery chemistry and configuration. The code was developed around Redash, a robust open-source extract-transform-load engine. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-4546 O

De Angelis, Valerio↗

Roadrunner

SAND2026-17073O Roadrunner software provides a comprehensive platform for simulating the mechanical behavior of crystalline materials under various loading conditions, allowing users to investigate the effects of dislocation slip hardening and damage evolution. Developed as a fork of the Multiphysics Object Oriented Simulation Environment (MOOSE) software from Idaho National Laboratory, Roadrunner is optimized for high-performance computing and can simulate large-scale problems, enabling researchers to explore complex scenarios. Its applications include material design and optimization in aerospace and automotive industries, investigation of failure mechanisms in structural materials, and development of predictive models for crystalline materials under various loading conditions. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Lim, Hojun [Sandia National Lab. (SNL-CA), Livermo↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

Smart Charging for Electric Ride-Hailing Vehicles using Renewables: A San Francisco Case Study

Charging large fleets of electric ride-hailing vehicles (ERVs) is a complex matter that could serve different objectives: lower carbon dioxide emissions, lower monetary expenditures, or maximize solar photovoltaics (PV) energy consumption. Currently, it is unclear how each of those objectives could impact the business and performance of a ride-hailing fleet. In order to fill this gap, this article employs a dynamic transportation model: a smart charging simulation that combines agent-based, discrete-event, and system dynamic modelling by comparing the above-mentioned objectives in separate scenarios. The results show that each scenario successfully manages to shift between 34% and 87% of all load to hours of the day when the objectives of those scenarios are met. Therefore, in comparison to the baseline, smart charging can save between 5% and 26% of monthly emissions and between 4% and 57% of monthly expenditures. The solar PV scenario, however, results in the highest savings, while ensuring profitable economics via net metering in the short- as well as long term. Finally, the sensitivity analysis points to important trade-offs between several fleet performance metrics. The article concludes by giving business and policy recommendations for maximising the economic, energy and environmental efficiency of large ERV fleets.

ADVANCED PROPULSION SYSTEMS,SOLAR ENERGY↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

RH-72B Packaging Plan Slides for University of Washington [Slides]

This report describes the Shipping Package RH-72B, specially in terms of why this container should be used, its features, how it will be utilized for the shipment of radiation and radioactive material from the University of Washington, and the placement of the 72B for loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗