Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

X-Ray Polarimetry with the Polarization Spectroscopic Telescope Array (PolSTAR)

This paper describes the Polarization Spectroscopic Telescope Array (PolSTAR), a mission proposed to NASA's 2014 Small Explorer (SMEX) announcement of opportunity. PolSTAR measures the linear polarization of 3-50 keV (requirement; goal: 2.5-70 keV) X-rays probing the behavior of matter, radiation and the very fabric of spacetime under the extreme conditions close to the event horizons of black holes, as well as in and around magnetars and neutron stars. The PolSTAR design is based on the technology developed for the Nuclear Spectroscopic Telescope Array (NuSTAR) mission launched in June 2012. In particular, it uses the same X-ray optics, extendable telescope boom, optical bench, and CdZnTe detectors as NuSTAR. The mission has the sensitivity to measure approx. 1% linear polarization fractions for X-ray sources with fluxes down to approx. 5 mCrab. This paper describes the PolSTAR design as well as the science drivers and the potential science return.

Krawczynski, Henric S.↗

Optical gyroscope system

Light beams pass in opposite directions through a single mode fiber optic wave guide that extends in a circle or coil in an optical gyroscope system which measures the rotation rate of the coil by measuring the relative phase shifts of the beams by interferometric techniques. Beam splitting and phase shifting of the light are facilitated by utilizing brief pulses of light and by using light-controlling devices which are operated for a brief time only when the light pulse passes in one direction through the device but not at a different time when the pulse is passing in the opposite direction through the device. High accuracy in rotation measurement is achieved at both very slow and very fast rotation rates, by alternately operating the system so that at zero rotation the interfering waves are alternately 90 out of phase and in phase. Linear polarization of the light beams is maintained by coiling the full length of the optic fiber in a single plane.

Goss, W. C.↗

Method for extracting long-equivalent wavelength interferometric information

A process for extracting long-equivalent wavelength interferometric information from a two-wavelength polychromatic or achromatic interferometer. The process comprises the steps of simultaneously recording a non-linear sum of two different frequency visible light interferograms on a high resolution film and then placing the developed film in an optical train for Fourier transformation, low pass spatial filtering and inverse transformation of the film image to produce low spatial frequency fringes corresponding to a long-equivalent wavelength interferogram. The recorded non-linear sum irradiance derived from the two-wavelength interferometer is obtained by controlling the exposure so that the average interferogram irradiance is set at either the noise level threshold or the saturation level threshold of the film.

Hochberg, Eric B.↗

Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly

This system was one of the test methods considered for measuring the radius of curvature of one or more of the 18 segmented mirrors that form the 6.5 m diameter primary mirror (PM) of the James Webb Space Telescope (JWST). The assembled telescope will be tested at cryogenic temperatures in a 17-m diameter by 27-m high vacuum chamber at the Johnson Space Center. This system uses a Leica Absolute Distance Meter (ADM), at a wavelength of 780 nm, combined with beam-steering and beam-shaping optics to make a differential distance measurement between a ring mirror on the reflective null assembly and individual PM segments. The ADM is located inside the same Pressure-Tight Enclosure (PTE) that houses the test interferometer. The PTE maintains the ADM and interferometer at ambient temperature and pressure so that they are not directly exposed to the telescope s harsh cryogenic and vacuum environment. This system takes advantage of the existing achromatic objective and reflective null assembly used by the test interferometer to direct four ADM beamlets to four PM segments through an optical path that is coincident with the interferometer beam. A mask, positioned on a linear slide, contains an array of 1.25 mm diameter circular subapertures that map to each of the 18 PM segments as well as six positions around the ring mirror. A down-collimated 4 mm ADM beam simultaneously covers 4 adjacent PM segment beamlets and one ring mirror beamlet. The radius, or spacing, of all 18 segments can be measured with the addition of two orthogonally-oriented scanning pentaprisms used to steer the ADM beam to any one of six different sub-aperture configurations at the plane of the ring mirror. The interferometer beam, at a wavelength of 687 nm, and the ADM beamlets, at a wavelength of 780 nm, pass through the objective and null so that the rays are normally incident on the parabolic PM surface. After reflecting off the PM, both the ADM and interferometer beams return to their respective instruments on nearly the same path. A fifth beamlet, acting as a differential reference, reflects off a ring mirror attached to the objective and null and returns to the ADM. The spacings between the ring mirror, objective, and null are known through manufacturing tolerances as well as through an in situ null wavefront alignment of the interferometer test beam with a reflective hologram located near the caustic of the null. Since total path length between the ring mirror and PM segments is highly deterministic, any ADM-measured departures from the predicted path length can be attributed to either spacing error or radius error in the PM. It is estimated that the path length measurement between the ring mirror and a PM segment is accurate to better than 100 m. The unique features of this invention include the differential distance measuring capability and its integration into an existing cryogenic and vacuum compatible interferometric optical test.

Merle, Cormic↗

Influence of Comptonization region over the ambiance of accretion disc in active galactic nucleus

ABSTRACT Understanding the radiative and physical structures of inner region of a few 100 pc of active galactic nucleus (AGNs) is important to constrain the causes of their activities. Although the X-ray emission from the Comptonization region/corona and the accretion disc regulates the broad-line emission regions and torus structures, the exact mutual dependency is not understood well. We performed correlation studies for X-ray, mid-infrared, and different components of Balmer emission lines for the selected sample of AGNs. Almost 10 different parameters and their interdependencies were explored in order to understand the underlying astrophysics. We found that the X-ray luminosity has a linear dependency on the various components of broad Balmer emission lines (e.g. L$_{\text{2-10 keV}}\, \propto$ L$^{0.78}_{\text{H}\beta ^{\text{B}}}$) and found a strong dependency on the optical continuum luminosity (L$_{\text{2-10 keV}}\, \propto$ L$^{0.86}_{5100\, \mathring{\rm A}}$). For a selected sample, we also observed a linear dependency between X-ray and mid-infrared luminosity (L$_{\text{2-10 keV}}\, \propto$ L$^{0.74}_{6\, \mu \text{m}}$). A break point was observed in our correlation studies for X-ray power-law index, Γ, and mass of black hole at ∼ log (M/M⊙) = 8.95. Similarly, the relations between Γ and full width at half-maximum (FWHM) of H α and H β broad components show breaks at FWHMH α = 7642 ± 657 km s−1 and FWHMH β = 7336 ± 650 km s−1. However, more data are required to confine the breaks locations exactly. We noted that Γ and Eddington ratios are negatively correlated to Balmer decrements in our selected sample. We analysed and discussed about the implications of new findings in terms of interaction AGN structures.

79 ASTRONOMY AND ASTROPHYSICS↗

PACE OCI Short-Wave Infrared Detection Assembly frequency-dependent linearity characterization and uncertainty analysis

The Ocean Color Instrument (OCI), the primary payload of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE)observatory, will collect data to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared(SWIR) Detection Assembly (SDA) was built and characterized by the Utah State University Space DynamicsLaboratory (SDL) and is a subsystem of OCI. The SDA measures seven bands centered at 940, 1038, 1250, 1378,1615, 2130, and 2260 nm, with standard- and high-gain varieties for the 1250 and 1615 nm bands, resulting in nine total detection configurations in the SWIR. The delivery of high-quality science data is critically dependent upon accurately characterizing the linearity of the SDA. Two metrology techniques were employed to measure the linearity and characterize the frequency-dependent linearity uncertainty of the system. The first technique used superposition linearity measurements to determine the DC linearity, and the second technique involved an oscillating small-signal response at seven frequencies to determine the frequency-dependent linearity. Discrepancies between the DC and frequency-dependent linearities constrain the uncertainty between the two. Examining the difference between these two methods for all SDA channels, we find most channels experience an uncertainty below0.2% with a worst-case measurement uncertainty of 0.31%. Averaging SDA channels with similar detectors, optical filters, and electronics to simulate the flight-like data products yields a worst-case frequency-dependence linearity uncertainty of 0.12%, demonstrating minimal frequency dependence, implying an excellent linearity knowledge.Detailed performance knowledge, including linearity performance, verifies data quality and builds confidence in the success of the PACE mission.

PACE↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

Autonomous sputter synthesis of thin film nitrides with composition controlled by Bayesian optimization of optical plasma emission

Autonomous experimentation has emerged as an efficient approach to accelerate the pace of material discovery. Although instruments for autonomous synthesis have become popular in molecular and polymer science, solution processing of hybrid materials, and nanoparticles, examples of autonomous tools for physical vapor deposition are scarce yet important for the semiconductor industry. Here, we report the design and implementation of an autonomous workflow for sputter deposition of thin films with controlled composition, leveraging a highly automated sputtering reactor custom-controlled by Python, optical emission spectroscopy (OES), and a Bayesian optimization algorithm. We modeled film composition, measured by x-ray fluorescence, as a linear function of plasma emission lines monitored during co-sputtering from elemental Zn and Ti targets in an N 2 and Ar atmosphere. A Bayesian control algorithm, informed by OES, navigates the space of sputtering power to fabricate films with user-defined compositions by minimizing the absolute error between desired and measured optical emission signals. We validated our approach by autonomously fabricating Zn x Ti 1-x N y films that deviate from the targeted cation composition by a relative ±3.5%, even for 15 nm thin films, demonstrating that the proposed approach can reliably synthesize thin films with a specific composition and minimal human interference. Moreover, the proposed method can be extended to more difficult synthesis experiments where plasma intensity lines depend non-linearly on pressure, or the elemental sticking coefficients strongly depend on the substrate temperature.

36 MATERIALS SCIENCE↗

Association of optical, ultraviolet, and soft X-ray excess emissions in AGNs

Soft X-ray emission (0.5–2.0 keV) plays a pivotal role in regulating the optical and ultraviolet (UV) emission in the active galactic nuclei (AGNs). We collected a sample of 1811 AGNs from the SDSS database and obtained various parameters of Balmer lines, optical continuum, Mg ii line & UV continuum and studied their dependencies on soft X-ray luminosity. Based on the linear regression analysis, we found that FWHM$_{\rm {Mg\,\,\small {II}}}$ ∝ FWHM$_{\text{H}\beta }^{0.554}$ suggesting that UV emission is arising from a region relatively outside the broad-line region (BLR) associated to the Hβ emission and found a strong correlation between optical and UV luminosities (L$_{\rm {Mg\,\,\small {II}}}$ ∝ $L_{\rm {H}\beta }^{0.822}$). It was noticed that the dependency of optical continuum luminosities on soft excess changes with the redshift (L X ∝ L$^{0.596}_{5100\, \mathring{\rm A}}$ for z < 0.5 and L X ∝ L$^{0.429}_{5100\, \mathring{\rm A}}$ for z > 0.5). The full width at half-maximum components of Hβ and Mg II core components were found to be virialized and is not affected by the soft excess emission whereas the wings of Mg II display a dependency. We estimated a relation viz. L X ∝L$^{0.520}_{3000\, \mathring{\rm A}}$ FWHM$^{0.525}_{\rm {Mg\,\,\small {II}}}$ and found to be well in agreement with a proposed physical scenario. All the derived relations were used to understand the intermodulating association of the BLR and disc in the AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Implementation of Matching Pursuit for Image Representation

We have developed a technique for image analysis, representation, and decomposition. This technique was motivated by Stephane Mallat's matching-pursuit algorithm. We've altered and simplified the mechanics of his algorithm to enable an extremely fast implementation via optical processing. Initial computer simulations show that our algorithm is capable of decomposing and representing a 2-D image as a linear combination of basis images with both high speed and high fidelity.

matching pursuit adaptive wavelet transform image ↗

Linear Covariance Analysis for a Lunar Lander

A next-generation lunar lander Guidance, Navigation, and Control (GNC) system, which includes a state-of-the-art optical sensor suite, is proposed in a concept design cycle. The design goal is to allow the lander to softly land within the prescribed landing precision. The achievement of this precision landing requirement depends on proper selection of the sensor suite. In this paper, a robust sensor selection procedure is demonstrated using a Linear Covariance (LinCov) analysis tool developed by Draper.

Jang, Jiann-Woei↗

iSPECTRON: a simulation interface for linear and nonlinear spectra with ab-initio quantum chemistry software

We introduce iSPECTRON, an open source (under the Educational Community License version 2.0) program that parses data from common quantum chemistry software (NWChem, OpenMolcas, Gaussian, Cobramm, etc.), produces the input files for the simulation of linear and nonlinear spectroscopy of molecules with the Spectron code, and analyzes the spectra with a broad range of tools. Vibronic spectra are expressed in term of the electronic eigenstates, obtained through quantum chemistry computations, and vibrational/bath effects are incorporated in the framework of the displaced harmonic oscillator model, where all required quantities are computed at the Franck-Condon point. The code capabilities are illustrated by simulating linear absorption, transient absorption and two dimensional electronic spectra of the pyrene molecule. Two levels of electronic structure theory, TDDFT (with NWChem) and RASSCF/RASPT2 (with OpenMolcas), are compared where possible. Acknowledgements: F.S., A.N., D.R.N., N.G., S.M, M.G. acknowledge support from the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Chemical Sciences, Geosciences, and Biosciences Division under Award Nos. DE-SC0019484, KC-030103172684. The Spectron code was developed with support from the National Science Foundation (Grant CHE- 1953045). This research benefited from computational resources provided by EMSL, a DOE Office of Science User Facility sponsored by the Office of Biological and Environmental Research and located at PNNL. PNNL is operated by Battelle Memorial Institute for the United States Department of Energy under DOE Contract No. DE-AC05-76RL1830.

Segatta, Francesco↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Ultrafast pulse pumping of topological nanospaser

Here, we theoretically examine a topological nanospaser that is optically pumped using an ultra-fast circularly-polarized pulse. The spasing system consists of a silver nanospheroid, which supports surface plasmon (SP) excitations, and a transition metal dichalcogenide (TMDC) monolayer nanoflake. The silver nanospheroid screens the incoming pulse and creates a non-uniform spatial distribution of electron excitations in the TMDC nanoflake. These excitations decay into the localized SPs, which can be of two types with the corresponding magnetic quantum number ±1. The amount and the type of the generated SPs depend on the intensity of the optical pulse. For small pulse amplitude, only one plasmonic mode is predominantly generated, resulting in far-field elliptically polarized radiation. For large amplitude of the optical pulse, both plasmonic modes are generated in almost the same amount, resulting in linearly polarized far-field radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗