Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Reburning of Animal Waste Based Biomass with Coal for NO x Reduction, Part I: Feedlot Biomass (FB) and Coal:FB Blends

Cattle biomass (CB or manure from cattle) is proposed as reburn fuel under slightly fuel-rich conditions. The CB includes wastes from cattle feedlots (cattle grown in feedlots to slaughter weights of 450–640 kg) termed as Feedlot Biomass (FB) and cattle wastes from dairy farms termed as Dairy Biomass (DB). NOx emissions from coal-fired power plants can be reduced by using pure CB and Coal:CB mixtures as reburn fuels (10~30% by heat) injected after the primary combustion region. Experiments with Coal:CB mixtures as reburn fuels were performed using the 30 kW burner facility. Part I deals with results from experiments using pure FB and Coal:FB blends as reburn fuels while Part II presents results on extent of NOx reduction using pure DB and Coal:DB blends as reburn fuels (RF). In the current work, results on NOx emission are presented with FB and Coal:FB blends as RF. The parametric studies include: equivalence ratio in reburn zone (ERRBZ), vitiated air, angle of reburn nozzles, presence and absence of heat exchangers (HEXs), and baseline NOx concentration. The optimum operating conditions for FB reburning were found to be conditions with vitiation at ERRBZ = 1.1 with 45° upward counter-current injection in the presence of HEXs. NOx emissions were reduced by as much as 96%.

09 BIOMASS FUELS↗

Engineering-Scale Integrated Energy System Data Projection Demonstration via the Dynamic Energy Transport and Integration Laboratory

The objective of this study is to demonstrate and validate the Dynamic Energy Transport and Integration Laboratory (DETAIL) preliminary scaling analysis using Modelica language system-code Dymola. The DETAIL preliminary scaling analysis includes a multisystem integral scaling package between thermal-storage and hydrogen-electrolysis systems. To construct the system of scaled equations, dynamical system scaling (DSS) was applied to all governing laws and closure relations associated with the selected integral system. The existing Dymola thermal-energy distribution system (TEDS) facility and high-temperature steam electrolysis (HTSE) facility models in the Idaho National Laboratory HYBRID repository were used to simulate a test case and a corresponding scaled case for integrated system HYBRID demonstration and validation. The DSS projected data based on the test-case simulations and determined scaling ratios were generated and compared with scaled case simulations. The preliminary scaling analysis performance was evaluated, and scaling distortions were investigated based on data magnitude, sequence, and similarity. The results indicated a necessity to change the normalization method for thermal storage generating optimal operating conditions of 261 kW power and mass flow rate of 6.42 kg/s and the possibility of reselecting governing laws for hydrogen electrolysis to improve scaling predictive properties. To enhance system-scaling similarity for TEDS and HTSE, the requirement for scaling validation via physical-facility demonstration was identified.

08 HYDROGEN↗

Hydrothermal but Not Mechanical Pretreatment of Wastewater Algae Enhanced Anaerobic Digestion Energy Balance due to Improved Biomass Disintegration and Methane Production Kinetics

This study used pilot-scale high-rate algae ponds to assess algal–bacteria biomass productivity and wastewater nutrient removal as well as the impact of mechanical and hydrothermal pretreatments on biomass disintegration, methane production kinetics, and anaerobic digestion (AD) energy balance. Mechanical pretreatment had a minor effect on biomass disintegration and methane production. By contrast, hydrothermal pretreatment significantly reduced particle size and increased the solubilized organic matter content by 3.5 times. The methane yield and production rate increased by 20–55% and 20–85%, respectively, with the highest values achieved after pretreatment at 121 °C for 60 min. While the 1st-order and pseudo-1st-order reaction equation models fitted methane production from untreated biomass best (R2 > 0.993), the modified Gompertz sigmoidal-type model provided a superior fit for hydrothermally pretreated algae (R2 ≥ 0.99). The AD energy balance revealed that hydrothermal pretreatment improved the total energy output by 25–40%, with the highest values for volume-specific and mass-specific total energy outputs reaching 0.23 kW per digester m3 and 2.3 MW per ton of biomass volatile solids. Additionally, net energy recovery (energy output per biomass HHV) increased from 20% for untreated algae to 32–34% for hydrothermally pretreated algae, resulting in net energy ratio and net energy efficiency of 2.14 and 68%, respectively.

09 BIOMASS FUELS↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Contextualizing Non-Powered Dam Site Selection for Archimedes Screw Turbines: A Methodology for Responsible Archimedes Screw Turbine Conversion at Existing Dams

Non-powered dams represent 97% of dams in the United States and their energy generation potential has not been fully realized. The use of an Archimedes screw turbine to generate power at non-powered dams offers a dual benefit; producing electricity, and acting as downstream fish passage, helping to reconnect previously separated ecosystems. In this study, we assess the technical, environmental, social, and economic feasibility of generating power at non-powered U.S. dam sites using Archimedes screw turbines by integrating mechanical constraints, social impact metrics, proximity to infrastructure, and environmental sensitivity data. Results account for future precipitation predictions and show, between 2024 and 2050, the number of sites where Archimedes screw turbines are viable decreases by one site, but overall generation capacity increases due to increased flow rates across persisting locations. Our analysis identified 82 non-powered dam sites with a mean generation capacity of 49 kW that meet the mechanical requirements for Archimedes screw turbine technology in 2024. Our analysis presents a framework for considering social, environmental, and economic impacts of specific turbine technologies to convert non-powered dams to generate power.

Archimedes screw turbine↗

Experimental Studies on Wood Pellets Combustion in a Fixed Bed Combustor Using Taguchi Method

The combustion of wood pellets in a fixed bed combustor of a 20 kW capacity domestic pellet boiler was tested according to several factors including Power, Excess Air (EA), Primary/Secondary air Split Ratio (SR) and Grate Area (GA). The Taguchi method was applied to program the experimental design. Several parameters were measured, including gas emissions (CO), fuel bed temperature (measured at 4 different heights), and efficiency. The experimental results show that the lower CO emission and the higher efficiency were obtained at medium thermal loads and the highest temperature on the fuel bed was obtained at about ¼ of its height (15 mm). The results obtained from the analysis of variance (ANOVA) show that the SR and the Power are the most important factors contributing to the CO reduction and also increase the fuel bed temperature.

Castro, Carlos↗

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

Investigating a Renewable-Resource-Targeting Mobile Aquaculture System Using Route Optimization Based on Optimal Foraging Theory

Aquaculture systems require careful consideration of location, which determines water conditions, pollution impacts, and hazardous conditions. Mobility may be able to address these factors while also supporting the targeting of renewable energy sources such as wind, wave, and solar power throughout the year. In this paper, a purpose-built mobile aquaculture ship is identified and modeled with a combination of renewable energy harvesting capabilities as a case study with the objective of assessing the potential benefits of targeting high renewable energy potentials to power aquaculture operations. A route optimization algorithm is created and tuned to simulate the mobility of the aquaculture platform and cost-basis comparisons are made to a stationary system. The small spatial variability in renewable energy potential when combining multiple resources significantly limits the benefits of a mobile, renewable-targeting aquaculture system. On the other hand, the consistent energy harvest from a blend of renewable energy types (13 kW installed wind capacity, 661 m 2 installed solar, and 1 m characteristic width wave-energy converter) suggests that the potential benefits of a mobile platform for offshore aquaculture (mitigation of environmental and social concerns, any potential positive impact on yields, hazard avoidance, etc.) can likely be pursued without significant increases in energy harvester costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simultaneous Reduction of NOx and Fuel Consumption for Off-Road Powertrains

Simultaneously reducing criteria pollutants and fuel consumption is important for clean air and improving vehicle total cost of ownership. The goal of this effort was focused on a 90% NOx reduction and 10% fuel savings for an off-road 407 kW diesel engine. The baseline was a production Fiat Powertrain 13L engine and aftertreatment system meeting 0.4 g/kW-hr NOx. The baseline system was quantified over the NRTC, RMC, new low load cycle and five field cycles. A next generation engine was built incorporating several fuel-efficient design features, including a higher compression ratio, increased fuel-rail pressure, low-friction piston rings, and a high-efficiency variable-geometry turbocharger. Cylinder deactivation and EGR pump technologies were added to this engine as well. The combination was optimized prior to adding advanced aftertreatment systems, showing the trade-off of engine out NOx and exhaust temperature. Two next-generation catalyst technologies were employed into a LO-SCR plus main SCR system, both with and without an electric heater upstream of the LO-SCR. These catalysts were hydrothermally aged to simulate significant field use. Dual SCR dosing with newly developed controls played a critical role in achieving the proper split between the upstream LO-SCR and the downstream main SCR. Adding a next generation mixer for the downstream SCR proved essential in obtaining the final results. The optimal configuration required adding an electric heater to elevate the exhaust temperature at the LO-SCR for early cycle NOx reduction. The final results showed a 94.8% NOx reduction and 15.7% fuel savings on the composite NRTC.

McCarthy, James [Eaton Corporation]↗

How wind speed shear and directional veer affect the power production of a megawatt-scale operational wind turbine

Most megawatt-scale wind turbines align themselves into the wind as defined by the wind speed at or near the center of the rotor (hub height). However, both wind speed and wind direction can change with height across the area swept by the turbine blades. A turbine aligned to hub-height winds might experience suboptimal or superoptimal power production, depending on the changes in the vertical profile of wind, also known as shear. Using observed winds and power production over 6 months at a site in the high plains of North America, we quantify the sensitivity of a wind turbine's power production to wind speed shear and directional veer as well as atmospheric stability. We measure shear using metrics such as α (the log-law wind shear exponent), β bulk (a measure of bulk rotor-disk-layer veer), β total (a measure of total rotor-disk-layer veer), and rotor-equivalent wind speed (REWS; a measure of actual momentum encountered by the turbine by accounting for shear). We also consider the REWS with the inclusion of directional veer, REWS θ , although statistically significant differences in power production do not occur between REWS and REWS θ at our site. When REWS differs from the hub-height wind speed (as measured by either the lidar or a transfer function-corrected nacelle anemometer), the turbine power generation also differs from the mean power curve in a statistically significant way. This change in power can be more than 70 kW or up to 5 % of the rated power for a single 1.5 MW utility-scale turbine. Over a theoretical 100-turbine wind farm, these changes could lead to instantaneous power prediction gains or losses equivalent to the addition or loss of multiple utility-scale turbines. At this site, REWS is the most useful metric for segregating the turbine's power curve into high and low cases of power production when compared to the other shear or stability metrics. Therefore, REWS enables improved forecasts of power production.

17 WIND ENERGY↗

X-Band Scanning ARM Precipitation Radar, CF/Radial Formatted, Quality Controlled

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

xsaprcfrqc↗

Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets

This repository contains simulated outputs from superwell – a hydro-economic tool for long-term assessment of groundwater cost and supply – providing globally gridded groundwater extractable volumes and associated unit costs ($/km³) for accessible groundwater production, based on a variety of user-defined depletion and ponded depth scenarios. Key model documentation: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 Find the source code of the superwell model on GitHub: https://github.com/JGCRI/superwell Repository Overview Main output: superwell_outputs.7z contains 6 files (4.5 GB) named as superwell_py_deep_all_0.*PD_0.*DL.csv. These files present superwell outputs of global groundwater extraction volumes and cost estimates on a 0.5° scale for six scenarios with different Ponded Depth (PD; 0.3 and 0.6 m) and Depletion Limit (DL; 5%, 25%, and 40% of available volume) targets over the entire pumping lifetime of a grid cell superwell_py_deep_all_0.3PD_0.25DL_sample_100.csv contains superwell outputs for 100 data points sampled to match the global inputs' distribution superwell_py_deep_all_0.3PD_0.25DL_Grid_72548.csv contains superwell output for a single grid cell concept_v5.png provides an overview of the superwell workflow Outputs Description year_number: year of pumping depletion_limit: set depletion limit (DL) as a volume fraction of total available groundwater Mappings: continent, country, gcam_basin_id, Basin_long_name, grid_id: geographic identifiers and basin information Inputs: grid_area (km²): area of the grid cell whyclass: hydrogeological classification of the aquifer permeability (m/day), porosity (%), total_thickness (m), depth_to_water (m): aquifer properties. The geo-processed input data has been published separately: https://doi.org/10.57931/2307831 Model outputs: orig_aqfr_sat_thickness (m), aqfr_sat_thickness (m): original and remaining/instantaneous saturated thickness of the aquifer hydraulic_conductivity (m/day), transmissivity (m²/day): hydraulic properties of the aquifer radius_of_influence (m), areal_extent (km²): well radius and area of influence from the center of the well number_of_wells (-): number of wells in a grid cell determined by a ratio of well area and grid area max_drawdown (m), drawdown (m), drawdown_interference (m): well and aquifer drawdown during extraction total_head (m): total lift for the groundwater (depth to water plus drawdown) total_well_length (m): total depth of wells drilled well_yield (m³/day): pumping rate or well yield power (kW), energy (kWh): power and energy required for pumping groundwater Volume Outputs: volume_produced_perwell (m³), cumulative_vol_produced_perwell (m³): production volume metrics per well volume_produced_allwells (m³), cumulative_vol_produced_allwells (m³): aggregate extraction volumes for all wells in a grid cell available_volume (m³): available groundwater in storage for the grid cell as determined by aquifer properties depleted_vol_fraction: fraction of total volume pumped over available volumes in a grid cell (same as depletion limit) Cost Outputs: well_installation_cost ($): well installation cost based on the hydrogeological complexity of the aquifer annual_capital_cost, maintenance_cost, nonenergy_cost ($): nonenergy costs energy_cost_rate ($/kWh): electricity rate energy_cost ($): energy cost of pumping groundwater total_cost_perwell ($), total_cost_allwells ($): total annual energy and non-energy cost for each and all wells in a grid cell a unit_cost ($/m³), unit_cost_per_km3 ($/km³), unit_cost_per_acreft ($/acre-ft): total cost of pumping a unit of groundwater, indicated for different spatial units Key Resources Model documentation: Niazi, H., Ferencz, S., Graham, N., Yoon, J., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024; In-prep). Long-term Hydro-economic Assessment Tool for Evaluating Global Groundwater Cost and Supply: Superwell v1. Geoscientific Model Development. Input data: Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MSD-LIVE Data repository. https://doi.org/10.57931/2307831 superwell source code: https://github.com/JGCRI/superwell Cite as Niazi, H., Ferencz, S., Yoon, J., Graham, N., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024). Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets. MSD-LIVE Data repository. https://doi.org/10.57931/2307832 Contact Reach out to Hassan Niazi or Stephen Ferencz or open an issue in the superwell repository for questions or suggestions.

Earth Systems↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Local Air Quality Impacts of a Peak-Shaving Diesel Generator Unit in Waynesville, North Carolina

The Waynesville Electric Department in Waynesville, North Carolina, operates a 2,000-kW diesel generator with a 4% capacity factor, emitting less than 1 ton annually of PM2.5, VOCs, carbon monoxide (CO), and sulfur dioxide (SO2), and approximately 1.8 tons of NO. The National Laboratory of the Rockies (NLR) conducted high-resolution, near-source air-quality modeling to evaluate the generator's impacts. Results indicate minimal effects on ambient pollutant concentrations: annual PM2.5 increases are below 0.0004 microgrm/m3 for local census tracts, while CO and SO2 levels increase by less than 0.00004 ppm and 0.0002 ppb, respectively. Estimated annual premature mortality attributable to PM2.5 exposure is less than 0.001 cases across Haywood County, with an associated economic impact of approximately $12,000. This report complements a separate technoeconomic analysis to inform Waynesville's investment strategies for demand reduction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗