Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Modeling of photocurrent and lag signals in amorphous selenium x-ray detectors

A mathematical model for transient photocurrent and lag signal in x-ray imaging detectors has been developed by considering charge carrier trapping and detrapping in the energy distributed defect states under exponentially distributed carrier generation across the photoconductor. The model for the transient and steady-state carrier distributions and hence the photocurrent has been developed by solving the carrier continuity equation for both holes and electrons. The residual (commonly known as lag signal) current is modeled by solving the trapping rate equations considering the thermal release and trap filling effects. The model is applied to amorphous selenium (a-Se) detectors for both chest radiography and mammography. The authors analyze the dependence of the residual current on various factors, such as x-ray exposure, applied electric field, and temperature. The electron trapping and detrapping mostly determines the residual current in a-Se detectors. The lag signal is more prominent in chest radiographic detector than in mammographic detectors. The model calculations are compared with the published experimental data and show a very good agreement.

42 ENGINEERING↗

Visualizing energy transfer between redox-active colloids

Redox-active colloids (RACs) represent a novel class of energy carriers that exchange electrical energy upon contact. Understanding contact-mediated electron transfer dynamics in RACs offers insights into physical contact events in colloidal suspensions and enables quantification of electrical energy transport in nonconjugated polymers. Redox-based electron transport was directly observed in monolayers of micron-sized RACs containing ethyl-viologen side groups via fluorescence microscopy through an unexpected nonlinear electrofluorochromism that is quantitatively coupled to the redox state of the colloid. Via imaging studies, using this electrofluorochromism, the apparent charge transfer diffusion coefficient D CT of the RAC was easily determined. The visualization of energy transport within suspensions of redox-active colloids was also demonstrated. Our work elucidates fundamental mechanisms of energy transport in colloidal systems, informs the development of next-generation redox flow batteries, and may inspire new designs of smart active soft matter including conductive polymers for applications ranging from electrochemical sensors and organic electronics to colloidal robotics.

Qu, Alan Subing [Univ. of Illinois at Urbana-Champ↗

NGEE Arctic Meteorological Data from Instrumented PCDC Stations, Council Site, Seward Peninsula, Alaska, 2018 - 2023

This dataset provides meteorological data collected at two instrumented Power, Communication, and Data Collection (PCDC) Stations, located at Council Road Mile Marker 71 (CN_MM71) and Council Road Mile Marker 68 (Rocky Top). Measurements began in June of 2018 at CN_MM71 and in September 2018 at Rocky Top and ended in 2023. Raw data included. Meteorological data include air temperature, relative humidity, wind speed and direction, and snow depth. Measurements have been aggregated to both 10-minute and 30-minute reporting intervals provided in four comma-separated (*.csv) data files.• The 30-minute data files include only the primary meteorological variables, leaf wetness, and snow depth.. The 30-minute reporting interval matches other coincident site data collections.• The 10-minute files provide the primary meteorological variables and numerous system operational parameters such as battery charge and solar and wind turbine status. This 10-minute data product is valuable for analyzing solar and wind charging system performance in arctic landscapes.Daily photographic images (09:00, 12:00, and 15:00 AKST/AKDT) of the PCDC Stations and the surrounding landscape that are captured by an adjacent web camera, are also provided.The daily 12:00 images from CN_MM71 camera have been compiled into time-lapse movies:• October 2018 – June 12, 2019 = Council_winter_2018_2019.mov• January 2019 – December 2019 = Council_2019.mp4The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Internal image motion compensation system for the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is being designed as a 1-m, cryogenically cooled telescope capable of a thirty-fold improvement over currently available infrared instruments. The SIRTF, mounted in the Orbiter bay on the Instrument Pointing System (IPS), requires that the image at the focal plane be stabilized to better than 0.1 arcsec with an absolute accuracy of 1 arcsec in order to attain this goal. Current estimates of IPS performance for both stability and accuracy indicate that additional stabilization will be necessary to meet the SIRTF requirements. An Image Motion Compensation (IMC) system, utilizing a Charge Coupled Device (CCD) star tracker located at the focal plane and a steerable mirror in the SIRTF optical path, has been designed to work in conjunction with the IPS.

Lorell, K. R.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

Ground-based observations of comets, the Jupiter plasma Torus, and Io

Aspects of cometary and magnetospheric physics were investigated by means of ground-based astronomical spectroscopy. High-throughput, dual-etalon Fabry-Perot spectrometers were used to obtain very high resolution spectra of atomic, molecular, and ionic emission lines from the diffuse gases and plasmas associated with comets and the Jupiter plasma torus. The Fabry-Perot spectrometers were also used with a charge coupled device (CCD) camera to obtain images of these extended emission sources in individual spectral lines at high spectral resolution. A new program using the McMath solar-stellar spectrograph to observe emission lines from Io was recently initiated. The McMath spectrograph has a high resolution mode which allows the detection of narrow, relatively faint emission lines superimposed on Io's reflected solar spectrum.

Scherb, Frank↗

A CCD-based search for very low mass members of the Pleiades cluster

We have obtained deep charge coupled device (CCD)V and I images of a number of fields near the center of the Pleiades open cluster. We have also obtained imaging data for Praesepe, a very similar cluster in terms of distance and richness but nearly 10 times older than the Pleiades. Because brown dwarfs are predicted to become much fainter and cooler between Pleiades and Praesepe ages, this provides a powerful differential technique for placing constraints on the brown dwarf population in open clusters. Combined with our previously reported observations, we now have data for about 0.4 sq deg in the Pleiades, corresponding roughly to 5% of the area of that cluster. We have searched the new CCD frames for additional Pleiades brown dwarf candidates. Two possible candidates are present, the faintest of which has V approximately equal to 22.5, (V-I)(sub K) approximately equal to 4.6. Because we do not have proper motion data and the colors of these objects are not redder than the reddest known field stars, it is possible that some or all of our candidates are somewhat higher mass field stars rather than Pleiades-age brown dwarfs. Even if all six of the proposed brown dwarf candidates in our 0.4 sq deg field are Pleiades members, the relatively small number found suggests that low mass stars or brown dwarfs do not contribute significantly to the total mass of the cluster.

Stauffer, John R.↗

A survey of nebulae around galactic wolf-rayet stars in the southern sky, 2.

We present the second half of a charge coupled device (CCD) narrow-band imaging survey of galactic Wolf-Rayet stars located in the southern hemisphere as listed by van der Hucht et al. (1981). Images of 50 Wolf-Rayet stars were taken using a wide-field CCD and narrowband interference filters centered on H alpha and (O III) 5007 A wavelengths. The first half of the survey (Marston, Chu, & Garcia-Segura 1993, hereafter Paper I) revealed six new ring nebulae residing around Wolf-Rayet stars. Here we reveal a possible 11 new rings and the existence of multiple rings associated with two previously known nebula, RCW 118 and G2.4+1.4 and around the stars WR 16 and WR 43. Combining our results with those of Miller & Chu (1993) and Paper I, 92% of the van der Hucht catalog of Wolf-Rayet stars have now been surveyed. Of the 38 possible ring nebulae found in our surveys to date, 22 reside around WN subtype Wolf-Rayet stars, 13 around WC stars, one around a triplet of Wolf-Rayet stars and one around a WO star (WR 102). One ring exists around a WN/WC star (WR 98). A bias toward rings being observed around W-R + OB binaries is noted. Such pairings are generally bright, and the detection of a ring around them may merely be a function of their combined luminosity. Several Wolf-Rayet stars are shown to be surrounded by multiple rings (two or three) which suggests that a number of ejections of stellar material have taken place during their evolution.

Marston, A. P.↗

Jet Evolution Visualized and Quantified Using Filtered Rayleigh Scattering

Filtered Rayleigh scattering was utilized as a flow diagnostic in an investigation of a method for enhancing mixing in supersonic jets. The primary objectives of the study were to visualize the effect of vortex generating tabs on supersonic jets, to exact quantitative data from these planar visualizations, and to detect the presence of secondary flows (i.e., streamwise vorticity) generated by the tabs. An injection seeded frequency-doubled Nd:YAG was the light source and a 14 bit Princeton Instruments iodine charge coupled display (ICCD) camera recorded the image through an iodine cell. The incident wave length of the laser was held constant for each flow case so that the filter absorbed unwanted background light, but permitted part of the thermally broadened Rayleigh scattering light to pas through. The visualizations were performed for axisymmetric jets (D=1.9 cm) operated at perfectly expanded conditions for Mach 1.0, 1.5, and 2.0. All data were recorded for the jet cross section at x/D=3. One hundred instantaneous images were recorded and averaged for each case, with a threshold set to eliminate unavoidable particulate scattering. A key factor in these experiments was that the stagnation air was heated such that the expansion of the flow in the nozzle resulted in the static temperature in the jet being equal to the ambient temperature, assuming isentropic flow. Since the thermodynamic conditions of the flow were approximately the same for each case, increases in the intensity recorded by the ICCD camera could be directly attributed to the Doppler shift, and hence velocity. Visualizations were performed for Mach 1.5 and Mach 2.0 jets with tabs inserted at the nozzle exit. The distortion of the jet was readily apparent and was consistent with Mie scattering-based visualizations. Asymmetry in the intensities of the images indicate the presence of secondary flow patterns which are consistent with the streamwise vortices measured using more traditional diagnostics in subsonic jets with the same tab configurations. Because each tab causes shocks to form, the assumption of isentropic flow is not valid for these cases. However, within a reasonable first-order estimation,the intensity across the illuminated plane for these cases can be related to a value combining density and velocity.

Reeder, Mark F.↗

Moving Away from Ones and Zeros, Designing a Ground Data System Based on Higher Levels of Abstraction

Previous JPL ground systems have been designed with the Ground Data System (GDS) engineer in mind. The focus on these systems has been on packaging and delivery of low level information (frames, packets, telemetry values) to the end user. It was not that long ago when project teams would be huddled over a workstation, examining crude displays of telemetry bits organized in various ways, trying to determine the status of a spacecraft. Understanding the data often required additional levels of GDS expertise, or worse, transformation of the raw data into alternative formats followed by ingestion into other tools so that the data became meaningful. The primary focus was often to answer these types of questions: "Why did this particular frame fail Reed-Solomon decode? Why did this packet get marked as invalid? Why am I missing a block of telemetry from my query?" -- which are completely valid questions to ask from a GDS Engineer's point of view, and large families of tools have been designed to help answer these questions. But these are not the questions that most users care about - which are more like: "Why is the battery state of charge trending down? Show me a summary image report for the last traverse to the target. Show me a data accountability summary for the last DSN pass." Answers to these questions, which are what users are looking for, requires a higher level of abstraction and supporting tools than mining through ones and zeros. JPL has created a next generation capability called the Mission Data Processing and Control System (MPCS) which is designed to support this higher level of abstraction by providing customizable views of the ground system combining collections of lower level information into more meaningful ways. Instead of examining frames, packets, and individual telemetry data points -- MPCS is capable of providing comprehensive summary reports, product status, overall flight/ground event status, as well as payload health summaries. Based on these higher level views, end users can make tactical or strategic decisions, or drop into detailed analysis as needed. System designers need to continue building systems that support low level GDS troubleshooting - but the basic design of a GDS should be geared towards what end users actually need to see. This paper will describe the capabilities of MPCS that directly support these higher levels of abstraction, and which are being used today in missions such as the Mars Science Laboratory and other NASA missions.

MPCS↗

3D Geolocation of Simulated Lightning Sources from Low-Earth Orbit

The recent removal of the Lightning Imaging Sensor from the International Space Station has left an observational gap in lightning detection from low-Earth orbit (LEO). However, new studies have demonstrated the potential for 3D geolocation of lightning sources using orbiting sensors. The Cubespark mission concept aims to take advantage of these developments by deploying a constellation of satellites with radio frequency (RF) sensors and optical imagers to not only map lightning locations, but also to collect bi-spectral flash images. These new capabilities include mapping storm charge structure, flash channel structure, and distinguishing microphysical processes throughout flash development, helping link microphysics and convective processes with overall flash and storm structure around the globe from LEO. In this study, we simulate lightning RF sources in the very high frequency (VHF) band, extrapolate their signals to space-based detection using an improved ionospheric model, and reconstruct their 3D locations using a time-of-arrival (TOA) minimization algorithm. Various constellation configurations, locations, and atmospheric conditions are considered in order to identify and quantify the three main sources of geolocation error: geometric, ionospheric, and instrumental effects. The promising results of this study emphasize the potential of space-based 3D lightning mapping under diverse conditions. 3D resolution is shown to be better than 1-2 km in many cases, enabling new global applications in meteorology and climate sciences. Here we present a selection of these geolocation results as seen from space alongside recent advancements, paving the way for a future generation of LEO lightning mappers.

CubeSpark↗

Nanometer-scale electrical potential imaging on absorber of CdSeTe solar cells

Here, we report on nm-scale electrical potential imaging throughout As-doped and Cu-doped CdSeTe absorbers using Kelvin probe force microscopy (KPFM). The potential imaging was conducted both laterally and vertically on beveled films using ion milling at small glancing angle. KPFM images electrical potential on the beveled surface and assesses defect charging in the subsurface region within a screening length from the beveled surface. We found that the grain boundaries were positively charged and that there were significant potential fluctuations in both grain boundary versus grain interior and intragrain. We further found that these potential fluctuations decreased significantly toward the front interface. Time of flight secondary ion mass spectrometry imaging shows that Se content increased toward the front interface, consistent with Se passivation of defects. The potential fluctuation was induced by defect charging, and the results elucidate different details of the defect configurations and grain structures of the films with different CdCl 2 treatment temperatures in the As-doped CdSeTe. The defect configurations in the region near the front interface can be a main factor contributing to the device performance difference. Our potential imaging provides insights about the defects throughout the absorber films, and shows that the potential fluctuation has a direct correlation to the V oc deficit.

14 SOLAR ENERGY↗

Microradiography with Semiconductor Pixel Detectors

High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Video Microscope Imaging System Implemented in Colloid Studies

Long description Photographs showing fiber-optic light source, microscope and charge-coupled discharge (CCD) camera head connected to camera body, CCD camera body feeding data to image acquisition board in PC, and Cartesian robot controlled via PC board. The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. CMIS can be used in situ with a minimum amount of user intervention. This system can scan, find areas of interest in, focus on, and acquire images automatically. Many multiple-cell experiments require microscopy for in situ observations; this is feasible only with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control. The software also has a user-friendly interface, which can be used independently of the hardware for further post-experiment analysis. CMIS has been successfully developed in the SML Laboratory at the NASA Glenn Research Center and adapted for use for colloid studies and is available for telescience experiments. The main innovations this year are an improved interface, optimized algorithms, and the ability to control conventional full-sized microscopes in addition to compact microscopes. The CMIS software-hardware interface is being integrated into our SML Analysis package, which will be a robust general-purpose image-processing package that can handle over 100 space and industrial applications.

McDowell, Mark↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗

Proposed Enhanced Imaging Station in the 6-GeV Booster-to-Storage Ring Transport Line for APS Upgrade

The high charge per micropulse of up to 17 nC in the booster to storage ring transport line (BTS) for APS Upgrade will necessitate changes in the imaging station used to evaluate beam emittance in this key region. The original Chromox screen has recently been replaced by a YAG:Ce single crystal for immediate screen spatial resolution improvement down to <10 µm. However, the optical system also needs an upgrade with lenses and a digital camera to take full advantage of this enhancement. In addition, at the high areal charge densities expected, the YAG:Ce scintillator mechanism will saturate, or quench, leading to images larger than the actual beam size. To circumvent this effect, optical transition radiation (OTR) screens will be implemented. A proposed longer-range goal of a non-intercepting beam-size monitor using optical diffraction radiation techniques during top-up injection will also be addressed.

43 PARTICLE ACCELERATORS↗