Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The structure of cockpit management attitudes

A revised version of the Cockpit Management Attitudes Questionnaire (CMAQ) is introduced. Factor analyses of responses from 3 different samples reveal comparable factor structure (previous attempts to factor analyze this measure had produced equivocal results). Implications for the measurement of attitudes and the assessment of attitude change are discussed. It is argued that the CMAQ will benefit both special training programs and efforts to explore attitude-performance linkages in air-transport operations.

NASA Program Space Human Factors↗

Dynamically Multiplexed Ion Mobility Time-of-Flight Mass Spectrometry

Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity high-throughput platform for e.g. proteomics applications. In this work, we have developed and integrated three advanced technologies, enabling (1) efficient ion accumulation in the ion funnel trap prior to IMS separation, (2) multiplexing (MP) of ion packet introduction into the IMS drift tube and (3) signal detection with an analog-to-digital converter (ADC), into the IMS-TOFMS system for the high-throughput analysis of highly complex proteolytic digests of e.g. blood plasma. To better address variable sample complexity, we have additionally developed and rigorously evaluated a new dynamic MP approach that ensures correlation of the analyzer performance with an ion source function, and provides the improved dynamic range and sensitivity. The MP IMS-TOF MS instrument has been shown to reliably detect peptides at a concentration of 1 nM in a highly complex matrix, as well as to provide a four orders of magnitude dynamic range and a mass measurement accuracy of better than 5 ppm. When matched against human blood plasma database, the detected IMS-TOF features yielded ~ 700 unique peptide identifications at a false discovery rate (FDR) of ~ 7.5 %. Accounting for IMS information gave rise to a projected FDR of ~ 4 %. Signal reproducibility was found to be greater than 80 %, while the variations in the number of unique peptide identifications were < 15 %. A single sample analysis was completed in 15 min, corresponding to approximately an order of magnitude improvement compared to a more conventional LC-MS approach.

Belov, Mikhail E.↗

Automated defect analysis in electron microscopic images

Electron microscopy and defect analysis are a cornerstone of materials science, as they offer detailed insights on the microstructure and performance of a wide range of materials and material systems. Building a robust and flexible platform for automated defect recognition and classification in electron microscopy will result in the completion of analysis orders of magnitude faster after images are recorded, or even online during image acquisition. Automated analysis has the potential to be significantly more efficient, accurate, and repeatable than human analysis, and it can scale with the increasingly important methods of automated data generation. Herein, an automated recognition tool is developed based on a computer vison–based approach; it sequentially applies a cascade object detector, convolutional neural network, and local image analysis methods. We demonstrate that the automated tool performs as well as or better than manual human detection in terms of recall and precision and achieves quantitative image/defect analysis metrics close to the human average. The proposed approach works for images of varying contrast, brightness, and magnification. Furthermore, these promising results suggest that this and similar approaches are worth exploring for detecting multiple defect types and have the potential to locate, classify, and measure quantitative features for a range of defect types, materials, and electron microscopic techniques.

47 OTHER INSTRUMENTATION↗

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),↗

SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and qualitative assessment, the proposed approach has superior noise reduction and anatomical structures preservation capabilities over existing noise removal methods. Senior Author Dr. Deshan Yang received research funding form ViewRay and Varian.

60 APPLIED LIFE SCIENCES↗

Steady state and transient temperature distributions in the human thigh covered with a cooling pad

An analytical and experimental study was done on the performance of cooling pads attached to a human thigh. Each cooling pad consisted of a long, water cooled tube formed into a serpentine shape with uniform spacing between the parallel sections. The analytical work developed a cylindrical model for the human thigh. The transient times predicted by this model ranged from 25 to 80 minutes, which is reasonably close to the experimental results. Calculated and measured steady state temperature profiles were in fair agreement. The transient times associated with a change from a high metabolic rate of 1800 Btu/hr (528 w) to a low level of 300 Btu/hr (88 w), were found to be about 120 minutes. A change from 300 Btu/hr (264 w) to 300 Btu/hr (88 w) resulted in 90 to 100 minute transients. However, the transient times for a change in metabolic rate in the opposite direction from 300 Btu/hr (88 w) to 1800 Btu/hr (528 w) were 40 to 60 minutes.

Leo, R. J.↗

Principled halftoning based on human vision models

When models of human vision adequately measure the relative quality of candidate halftonings of an image, the problem of halftoning the image becomes equivalent to the search problem of finding a halftone that optimizes the quality metric. Because of the vast number of possible halftones, and the complexity of image quality measures, this principled approach has usually been put aside in favor of fast algorithms that seem to perform well. We find that the principled approach can lead to a range of useful halftoning algorithms, as we trade off speed for quality by varying the complexity of the quality measure and the thoroughness of the search. High quality halftones can be obtained reasonably quickly, for example, by using as a measure the vector length of the error image filtered by a contrast sensitivity function, and, as the search procedure, the sequential adjustment of individual pixels to improve the quality measure. If computational resources permit, simulated annealing can find nearly optimal solutions.

Mulligan, Jeffrey B.↗

Identifying Planetary Transit Candidates in TESS Full-frame Image Light Curves via Convolutional Neural Networks

The Transiting Exoplanet Survey Satellite(TESS)mission measured light from stars in∼75% of the sky throughout its 2 yr primary mission, resulting in millions of TESS 30-minute-cadence light curves to analyze in the search for transiting exoplanets. To search this vast data trove for transit signals, we aim to provide an approach that both is computationally efficient and produces highly performant predictions. This approach minimizes the required human search effort. We present a convolutional neural network, which we train to identify planetary transit signals and dismiss false positives. To make a prediction for a given light curve, our network requires no prior transit parameters identified using other methods. Our network performs inference on a TESS 30-minute-cadence light curve in∼5 ms on a single GPU, enabling large-scale archival searches. We present 181 new planet candidates identified by our network, which pass subsequent human vetting designed to rule out false positives.Our neural network model is additionally provided as open-source code for public use and extension

Gregory Olmschenk↗

Urine Radiobioassay Intercomparison Results From The Intercomparison Studies Program At Oak Ridge National Laboratory

The Intercomparison Studies Program (ISP) at the Oak Ridge National Laboratory (ORNL, Oak Ridge, TN USA) provides natural-matrix human urine quality-assurance/quality-control (QA/QC) samples to radiobioassay analysis laboratories. Samples are provided to these laboratories as 'single-blind' or 'double-blind' unknowns, spiked with radioactive-solution standards at 'low' levels (e.g., 0-250 mBq {center_dot} kg{sup -1} for alpha-emitters). Participants use the results as a tool for self-evaluation and a measure of performance. In this paper, sample preparation and the results of testing during the years 2000-2004 for the radionuclides natural uranium (U-nat), {sup 238}Pu, {sup 239}Pu, and {sup 241}Am are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A comparison of digital radiography systems in terms of effective detective quantum efficiency

Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human exercise capabilities in space

Maintenance of rest and exercise performance are prime requirements for all astronauts during flight, not only for maintaining day-to-day productivity, but also for coping with unlikely emergencies. Indirect estimates of submaximal work capacity (oxygen uptake) made from changes in the heart rates of 27 Apollo astronauts (less than 15-day flights) indicated a reduction in work capacity (maximal oxygen uptake) of 17 to 21 percent. This percentage decrease was similar to that measured in middle-aged men after 21 to 30 days of -6 deg head-down bed-rest deconditioning without exercise training. Heart-rate changes during submaximal exercise in the nine Skylab astronauts suggested that they were better able to maintain their work capacity because of longer and more intensive in-flight exercise training. The strength of the flexor and extensor muscle groups decreased by 2 to 9 percent in the elbow and by 6 to 20 percent in the knee in the Skylab astronauts, also similar to the decreases in men undergoing 30 days of bed-rest deconditioning. Exercise protocols have been devised that result in maintenance of work capacity and muscular strength during 30 to 49 days of bed-rest deconditioning.

Greenleaf, John E.↗

Presound: UAV Diagnostic System Enabled by Vibration-Based Machine Learning

A low-weight, inexpensive small unmanned aerial system (sUAS) that takes off, performs a mission, lands, and safely stows and recharges itself has myriad future applications ranging from agricultural imaging to last-mile package delivery. Likewise, Urban Air Mobility (UAM) systems will enable people to take air taxis from point to point in cities, rapidly moving commuters long distances without concern for road traffic and congestion. Fully electric aviation systems will be cleaner and quieter than ground transport. Cities could eliminate cars and buses, and convert roads to higher capacity bike and pedestrian throughways. Yet, for sUAS as well as UAM, system reliability and assurance is a limiting factor to deploying affordable autonomous flight systems. For this bright future of aviation to be realized, aircraft must be able to autonomously and accurately self-diagnose health issues both before takeoff and during flight. The GreenSight PreSound system is designed to identify defects on aircraft through intelligent analysis of vibration. It accomplishes this by measuring structural vibrations induced by the vehicle’s own propellers, and analyzing that data using a machine learning model that determines whether a defect is present. The PreSound system is designed to require no human oversight, and to operate across a wide array of vehicles through re-training of the model for each target aircraft. PreSound has been developed and seen limited early success using data collected from the GreenSight Dreamer sUAS, a 5lb quadrotor vehicle designed for aerial imaging applications. The final detection model, trained on data with props spinning at 50% throttle, achieves excellent performance with over 99% average accuracy in detecting blade damage using a single FFT vector input. It demonstrates the ability to generalize to new types of blade damage, correctly classifying a different type of blade damage with 98% accuracy. Full test pulses were classified with 100% accuracy, and in live testing, all sets of data during blade movement were classified accurately with over 95% confidence. When trained on in-flight data, the same model achieves an average accuracy of 85% in distinguishing between undamaged and blade-damaged states in flight. The authors believe that these accuracies show significant potential of this approach to expand unmanned flight safety, with significant potential benefits in accelerating Advanced Aerial Mobility (AAM) and UAM aviation applications.

UAS↗

Biophysical and biological meanings of healthspan from C. elegans cohort

Highlights: • We focus on a third factor, noise, as well as on genetic and environmental factors. • C. elegans fed a healthy food had an extended healthspan as compared to those fed a conventional diet. • An amplification of ATP noise was clearly evident from around the onset of biodemographic aging. • The extension of timing of noise amplification may contribute to effectively extending the healthspan. • The same mechanism of the mean lifespan extension in C. elegans may be realized in humans. - Abstract: Lifespan among individuals ranges widely in organisms from yeast to mammals, even in an isogenic cohort born in a nearly uniform environment. Needless to say, genetic and environmental factors are essential for aging and lifespan, but in addition, a third factor or the existence of a stochastic element must be reflected in aging and lifespan. An essential point is that lifespan or aging is an unpredictable phenomenon. The present study focuses on elucidating the biophysical and biological meanings of healthspan that latently indwells a stochastic nature. To perform this purpose, the nematode Caenorhabditis elegans served as a model animal. C. elegans fed a healthy food had an extended healthspan as compared to those fed a conventional diet. Then, utilizing this phenomenon, we clarified a mechanism of healthspan extension by measuring the single-worm ATP and estimating the ATP noise (or the variability of the ATP content) among individual worms and by quantitatively analyzing biodemographic data with the lifespan equation that was derived from a fluctuation theory.

60 APPLIED LIFE SCIENCES↗

Risk-informed Physical Security Using Dynamic Force-on-Force Modelling Tools (ABSTRACT)

Physical security requirement of nuclear power plants (NPPs) in the US is regulated in a mainly prescriptive manner. This “one size fits all” approach may consequently overlook plant-specific characteristics which are beneficial for the inherent safety and security of the plant. Although a performance-based security measure has been promulgated in 10 CFR 73.55(r), current evaluation methods generally emphasize static and conservative assumptions on physical security uncertainties. This conservatism contributes to the overall operational and maintenance costs, which account to 70% of total operating expenditures for an NPP. This paper describes an ongoing work at the Idaho National Laboratory within the Light Water Reactor Sustainability pathway, which aims to optimize physical protection system with regards to system effectiveness and dollar costs. To achieve this goal, a risk-informed approach to physical security is proposed. This approach leverages the Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool to model facility infiltration and Force-on-Force (FoF) engagement in a dynamic manner. The dynamic FoF analysis was conducted by coupling human performance uncertainties modeled in EMRALD to existing commercial 3-dimensional FoF software, i.e. SCRIBE3D, AVERT and Simajin. Meanwhile, risk analysis was accomplished by coupling the attack outcomes to existing plant Probabilistic Risk Assessment (PRA) model with FLEX strategy. This approach reduces the conservatisms in security modeling and further acknowledges the possibility for plant operators to mitigate the attack outcomes. A sabotage attack on a hypothetical NPP facility was devised to demonstrate the proposed methodology. Dynamic FoF rules were implemented in EMRALD coupled to SCRIBE3D. This dynamic evaluation revealed an additional 21% system effectiveness in protecting the target set relative to the static modelling approach. Furthermore, the conditional core damage probability could be reduced by up to 46% by crediting operator actions in mitigating the sabotage outcomes. We evaluated the relative importance of each component of the physical security posture included in the model and assessed tradeoffs between components to identify potential opportunities for cost reduction while maintaining a specific level of system effectiveness. Results of the cost analysis will be presented in the conference. This study is expected to help NPP operators in allocating resources optimally to satisfy the security requirements.

97 MATHEMATICS AND COMPUTING↗

Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.

Wood, Scott J.↗

A long-term three dimensional liver co-culture system for improved prediction of clinically relevant drug-induced hepatotoxicity

Drug-induced liver injury (DILI) is the major cause for liver failure and post-marketing drug withdrawals. Due to species-specific differences in hepatocellular function, animal experiments to assess potential liabilities of drug candidates can predict hepatotoxicity in humans only to a certain extent. In addition to animal experimentation, primary hepatocytes from rat or human are widely used for pre-clinical safety assessment. However, as many toxic responses in vivo are mediated by a complex interplay among different cell types and often require chronic drug exposures, the predictive performance of hepatocytes is very limited. Here, we established and characterized human and rat in vitro three-dimensional (3D) liver co-culture systems containing primary parenchymal and non-parenchymal hepatic cells. Our data demonstrate that cells cultured on a 3D scaffold have a preserved composition of hepatocytes, stellate, Kupffer and endothelial cells and maintain liver function for up to 3 months, as measured by the production of albumin, fibrinogen, transferrin and urea. Additionally, 3D liver co-cultures maintain cytochrome P450 inducibility, form bile canaliculi-like structures and respond to inflammatory stimuli. Upon incubation with selected hepatotoxicants including drugs which have been shown to induce idiosyncratic toxicity, we demonstrated that this model better detected in vivo drug-induced toxicity, including species-specific drug effects, when compared to monolayer hepatocyte cultures. In conclusion, our results underline the importance of more complex and long lasting in vitro cell culture models that contain all liver cell types and allow repeated drug-treatments for detection of in vivo-relevant adverse drug effects. - Highlights: ► 3D liver co-cultures maintain liver specific functions for up to three months. ► Activities of Cytochrome P450s remain drug- inducible accross three months. ► 3D liver co-cultures recapitulate drug-induced liver toxicity observed in vivo. ► 3D liver co-cultures can detect species-specific drug toxicity observed in vivo. ► This in vitro model may improve assessment of human relevance of preclinical findings.

60 APPLIED LIFE SCIENCES↗

Integrated nonlinear optical imaging microscope for on-axis crystal detection and centering at a synchrotron beamline

Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3 –10 4 -fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.

bio-inspired↗

Introducing Human Mandible Identification [(hu)MANid]: A Free, Web‐Based GUI to Classify Human Mandibles

Abstract Statistical programs have revolutionized the way in which forensic anthropologists conduct casework by allowing practitioners to use computationally complex analytics at the click of a button. Importantly, the products of these statistical programs are reproducible and contain measures of error or uncertainty, thereby strengthening conclusions. This paper is an introduction to (hu) MAN id, a free, web‐based application that uses linear and mixture discriminant function analyses to classify human mandibles into one of many worldwide and/or periodic reference groups. The mechanics, development, and use of the application will be discussed. Further, the program was tested against other software to compare model performances and classifications. Total correct classifications among the test cases and programs were identical. Ten mandibles were tested using both statistical procedures. Mixture discriminant analysis improved classification by an average of 9.3% and correctly identified three more mandibles than LDA . Therefore, we believe (hu) MAN id will be an asset to the anthropological community.

Berg, Gregory E.↗