Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Revisiting the Corrosion of the Aluminum Current Collector in Lithium-Ion Batteries

The corrosion of aluminum current collectors and the oxidation of solvents at a relatively high potential have been widely investigated with an aim to stabilize the electrochemical performance of lithium-ion batteries using such components. The corrosion behavior of aluminum current collectors was revisited using a home-build high-precision electrochemical measurement system, and the impact of electrolyte components and the surface protection layer on aluminum foil was systematically studied. The electrochemical results showed that the corrosion of aluminum foil was triggered by the electrochemical oxidation of solvent molecules, like ethylene carbonate, at a relative high potential. The organic radical cations generated from the electrochemical oxidation are energetically unstable, and readily undergo a deprotonation reaction that generates protons and promote the dissolution of Al3+ from the aluminum foil. This new reaction mechanism can also shed light on the dissolution of transitional metal at high potentials.

Environmental Molecular Sciences Laboratory↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

To Duct or Not to Duct: Evaluating the Space Conditioning Impacts of Heat Pump Water Heaters in the PNNL Lab Homes

Heat pump water heaters (HPWH) are a promising technology for substantially reducing water heating-related energy use in the residential sector. However, concerns have been raised regarding the impact of HPWHs on space conditioning energy when installed in conditioned space, primarily in northern climates. For example, the Northwest Energy Efficiency Alliance (NEEA’s) Northern Climate HPWH Specification, which describes the characteristics a HPWH must have to be incentivized in cold climates in the Pacific Northwest (PNW), requires exhaust ducting for their Tier II-specified products and both supply and exhaust ducting for the Tier III-specified product (NEEA 2013). However, these concerns and installation recommendations are based on modeling and comparative field data are not available to verify modeled performance. This study examines the overall performance and operation of two GE GeoSpring HPWHs in conditioned space in the matched pair of PNNL Lab Homes with no ducting, exhaust ducting, and full ducting (supply and exhaust) and explores the interactions between the HPWH and the home’s heating/cooling system. The data collected in this field evaluation suggest that previous modeling may not completely characterize the complex interactions of HPWHs, HVAC systems, and ducting. This report discusses the impact on space conditioning and water heater energy use of configuring an HPWH with exhaust only ducting or full ducting, as compared to an unducted HPWH. Additional cost analysis is necessary to assess the cost effectiveness of ducting and to make formal recommendations regarding appropriate installation of HPWHs in more varied scenarios.

energy efficiency↗

Simulation of high-power electromagnetic wave heating in the ITER burning plasma

The next step toward fusion as a practical energy source is the design and construction of ITER [R. Aymar et al., Nucl. Fusion 41, 1301 (2001)], a device capable of producing and controlling the high-performance plasma required for self-sustaining fusion reactions, i.e., 'burning plasma'. ITER relies in part on ion-cyclotron radio frequency power to heat the deuterium and tritium fuel to fusion temperatures. In order to heat effectively, the radio frequency wave fields must couple efficiently to the dense core plasma. Calculations in this paper support the argument that this will be the case. Three-dimensional full-wave simulations show that fast magnetosonic waves in ITER propagate radially inward with strong central focusing and little toroidal spreading. Energy deposition, current drive, and plasma flow are all highly localized near the plasma center. Very high resolution, two-dimensional calculations reveal the presence of mode conversion layers, where fast waves can be converted to slow ion cyclotron waves. When minority ions such as deuterium or helium-3 are used to damp the launched waves, these ions can be accelerated to high energies, forming suprathermal tails that significantly affect the wave propagation and absorption. By neglecting the toroidal localization of the waves and the finite radial excursion of the energetic particle orbits, the quasilinear evolution of these suprathermal ion tails can be simulated self-consistently in one spatial dimension and two velocity dimensions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A competing risks approach for time estimation of household WEEE disposal

The recent growth in the number of electrical and electronic devices is viewed as one the priority waste streams in European Union waste management policy. This paper presents the findings of a survey to study domestic habits with respect to Waste Electrical and Electronic Equipment (WEEE) in Spain. A specific problem when performing this estimation arises from the fact that consumers quite often store old appliances at home when they are no longer used. Focusing on four different types of appliance, survival analysis (SA) is used to study both the usage span and the reasons for no longer using each device. The time that the discarded products were kept at home before being disposed of was studied using competing risks (CR) analysis. The results of the analysis provide information on the distribution of the studied variables for the different outcomes as well as the influence exerted by the socio-demographic variables considered. Relations between these characteristics and the storage time of the appliances before disposal emerge based on survey data. For instance, the CR model finds that the storage time of the some appliances (i.e. refrigerator) is related to these social-demographics factors. However, other appliances (i.e. microwave oven) are less influenced by these factors. The attitude and motivation of the respondents to the survey as regards the End-of-Life of appliances were also analysed. A majority of respondents do not store discarded appliances at home. The first reason for storing appliances at home is the possibility of it being useful in the future and the second that the respondents did not know what to do with them.

54 ENVIRONMENTAL SCIENCES↗

Durable Airtightness in Single-Family Dwellings - Field Measurementsand Analysis

Here, durability of the building envelope is important to new homes that are increasingly built with improved levels of airtightness. It is also important to weatherized homes such that energy savings from retrofit measures, such as air sealing, are persistent. This paper presents a comparison of air leakage measurements collected in November 2013 through March 2014, with two sets of prior data collected between 2001-2003 from 17 new homes located near Atlanta, GA, and 17 homes near Boise, ID that were weatherized in 2007- 2008. The purpose of the comparison is to determine if there are changes to the airtightness of building envelopes over time. The air leakage increased in all but one of the new homes, with a mean increase of about 25%. The weatherized homes also showed an increase in the mean air leakage (12%). A regression analysis was performed to describe the relationship between prior and current measurements in terms of normalized leakage (NL). The best estimate of the ageing factor predicts a 15% increase in NL over ten years. Further analysis using ResDB data (LBNL’s Residential Diagnostic Database) showed the expected changes in air leakage if ageing were modelled. These results imply the need to examine the causes of increased leakage and methods to avoid them. This increase in leakage with time should be accounted for in long-term population-wide energy savings estimates, such as those used in ratings or energy savings programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploration Challenges: Transferring Ground Repair Techniques to Space Flight Application

Fulfilling NASA's Vision for Space Exploration will demand an extended presence in space at distances from our home planet that exceed our current experience in space logistics and maintenance. The ability to perform repairs in lieu of the customary Orbital Replacement Unit (ORU) process where a faulty part is replaced will be elevated from contingency to routine to sustain operations. The use and cost effectiveness of field repairs for ground based operations in industry and the military have advanced with the development of technology in new materials, new repair techniques and new equipment. The unique environments, accessibility constraints and Extra Vehicular Activity (EVA) issues of space operations will require extensive assessment and evolution of these technologies to provide an equivalent and expected level of assurance to mission success. Challenges include the necessity of changes in design philosophy and policy, extremes in thermal cycling, disruptive forces (such as static charge and wind entrainment) on developed methods for control of materials, dramatically increased volatility of chemicals for cleaning and other compounds due to extremely low pressures, the limits imposed on dexterity and maneuverability by current EVA equipment and practices, and the necessity of unique verification methodology. This paper describes these challenges in and discusses the effects on the established ground techniques for repair. The paper also describes the leading repair methodology candidates and their beneficial attributes for resolving these issues with the evolution of technology.

McLemore, Carole A.↗

Eaglesprings and Waterhaven Communities

This case study describes two David Weekley Homes developments near Houston, Texas, that consist of single-family houses, and feature high performance in a production setting.

Building Science Corporation↗

Veridian Homes: Cold Climate Region 40+% Energy Savings

This case study profiles Veridian builder's Whitman “Welcome Home” prototype based upon Building America practices, which features a solar water heating system, high performance envelope, and high efficiency mechanical equipment.

CARB↗

An in-home study of subjective response to simulated sonic booms

The proposed development of a second-generation supersonic commercial transport has resulted in increased research efforts to provide an environmentally acceptable aircraft. One of the environmental issues is the impact of sonic booms on people. Aircraft designers are attempting to design the transport to produce sonic boom signatures that will have minimum impact on the public. Current supersonic commercial aircraft produce an 'N-wave' sonic boom pressure signature that is considered unacceptable by the public. This has resulted in first-generation supersonic transports being banned from flying supersonically over land in the United States, a severe economic constraint. By tailoring aircraft volume and lift distributions, designers hope to produce sonic boom signatures having specific shapes other than 'N-wave' that may be more acceptable to the public and could possibly permit overland supersonic flight. As part of the effort to develop a second-generation supersonic commercial transport, Langley Research Center is conducting research to study people's subjective response to sonic booms. As part of that research, a system was developed for performing studies of the subjective response of people to the occurrence of simulated sonic booms in their homes. The In-Home Noise Generation/Response System (IHONORS) provides a degree of situational realism not available in the laboratory and a degree of control over the noise exposure not found in community surveys. The computer-controlled audio system generates the simulated sonic booms, measures the noise levels, and records the subjects' rating and can be placed and operated in individuals' homes for extended periods of time. The system was used to conduct an in-home study of subjective response to simulated sonic booms. The primary objective of the study was to determine the effect on annoyance of the number of sonic boom occurrences in a realistic environment.

Mccurdy, David A.↗