Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Optical Instrument Thermal Control on the Large Ultraviolet/Optical/Infrared Surveyor

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a multi-wavelength observatory commissioned by NASA as one of four large mission concept studies for the Astro2020 Decadal Survey. Two concepts are under study which bound a range of cost, risk, and scientific return: an 8-meter diameter unobscured segmented aperture primary mirror and a 15-meter segmented aperture primary mirror. Each concept carries with it an accompanying suite of instruments. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is a near-ultraviolet (NUV) / optical / near-infrared (NIR) coronagraph; the LUVOIR Ultraviolet Multi-object Spectrograph (LUMOS) provides multi-object imaging spectroscopy in the 100-400 nanometer ultraviolet (UV) range; and the High Definition Imager (HDI) is a wide field-of-view near-UV / optical / near-IR camera that can also perform astrometry. The 15-meter concept also contains an additional instrument, Pollux, which is a high-resolution UV spectro-polarimeter. While the observatory is nominally at a 270 Kelvin operational temperature, the requirements of imaging in both IR and UV require separate detectors operating at different temperature regimes, each with stringent thermal stability requirements. The change in observatory size requires two distinct thermal designs per instrument. In this current work, the thermal architecture is presented for each instrument suite. We describe here the efforts made to achieve the target operational temperatures and stabilities with passive thermal control methods. Additional discussion will focus on how these instrument thermal designs impact the overall system-level architecture of the observatory and indicate the thermal challenges for hardware implementation.

Decadal Study↗

Optical Instrument Thermal Control on the Large Ultraviolet/Optical/Infrared Surveyor

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a multi-wavelength observatory commissioned by NASA as one of four large mission concept studies for the Astro2020 Decadal Survey. Two concepts are under study which bound a range of cost, risk, and scientific return: an 8-meter diameter unobscured segmented aperture primary mirror and a 15-meter segmented aperture primary mirror. Each concept carries with it an accompanying suite of instruments. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is a near-ultraviolet (NUV) / optical / near-infrared (NIR) coronagraph; the LUVOIR Ultraviolet Multi-object Spectrograph (LUMOS) provides multi-object imaging spectroscopy in the 100-400 nanometer ultraviolet (UV) range; and the High Definition Imager (HDI) is a wide field-of-view near-UV / optical / near-IR camera that can also perform astrometry. The 15-meter concept also contains an additional instrument, Pollux, which is a high-resolution UV spectro-polarimeter. While the observatory is nominally at a 270 Kelvin operational temperature, the requirements of imaging in both IR and UV require separate detectors operating at different temperature regimes, each with stringent thermal stability requirements. The change in observatory size requires two distinct thermal designs per instrument. In this current work, the thermal architecture is presented for each instrument suite. We describe here the efforts made to achieve the target operational temperatures and stabilities with passive thermal control methods. Additional discussion will focus on how these instrument thermal designs impact the overall system-level architecture of the observatory and indicate the thermal challenges for hardware implementation.

LUVOIR↗

Electronic imaging and scanning system

Frequency-variable illumination has been used previously to provide high resolution imaging in one dimension. The paper extends the results on this imaging by frequency scanning to derive the expression for a two-dimensional image. This is the Fourier transformation, with respect to the angle and frequency of illumination, of the electric field detected in the far-field region of the object. The case is considered of a rough object and it is shown that for roughness finer than the resolution of the imaging system, the image has a granular appearance corresponding to the classical speckle effect. Large scale phase perturbations lead to the elevation displacement effect.

Jain, A.↗

Soft X-ray images of the solar corona with a normal-incidence Cassegrain multilayer telescope

High-resolution images of the sun in the soft X-ray to EUV regime have been obtained with normal-incidence Cassegrain multilayer telescopes operated from a sounding rocket in space. The inherent energy-selective property of multilayer-coated optics allowed distinct groups of emission lines to be isolated in the solar corona and the transition region. The Cassegrain telescopes provided images in bands centered at 173 and 256 A. The bandpass centered at 173 A is dominated by emission from the ions Fe IX and Fe X. This emission is from coronal plasma in the temperature range (8-14) x 10 to the 6th K. The images have angular resolution of about 1.0-1.5 arcsec and show no degradation because of X-ray scattering. Many features of coronal structure, including magnetically confined loops of hot plasma, coronal plumes, polar coronal holes, faint structures on the size scale of supergranulation and smaller, and features due to everlying cool prominences are visible in the images. The density structure of polar plumes, which are thought to contribute to the solar wind, has been derived from the observations out to 1.7 solar radii.

Walker, Arthur B. C., Jr.↗

High speed two-dimensional imaging with an analog interface

A quantitative pulse count (event detection) algorithm with linearity to high count rates is accomplished by combining a high-speed, high frame rate camera with simple logic code run on a massively parallel processor such as a GPU. The parallel processor elements examine frames from the camera pixel by pixel to find and tag events or count pulses. The tagged events are combined to form a combined quantitative event image.

Waugh, Justin↗

In situ melt pool measurements for laser powder bed fusion using multi sensing and correlation analysis

Laser powder bed fusion is a promising technology for local deposition and microstructure control, but it suffers from defects such as delamination and porosity due to the lack of understanding of melt pool dynamics. To study the fundamental behavior of the melt pool, both geometric and thermal sensing with high spatial and temporal resolutions are necessary. This work applies and integrates three advanced sensing technologies: synchrotron X-ray imaging, high-speed IR camera, and high-spatial-resolution IR camera to characterize the evolution of the melt pool shape, keyhole, vapor plume, and thermal evolution in Ti–6Al–4V and 410 stainless steel spot melt cases. Aside from presenting the sensing capability, this paper develops an effective algorithm for high-speed X-ray imaging data to identify melt pool geometries accurately. Preprocessing methods are also implemented for the IR data to estimate the emissivity value and extrapolate the saturated pixels. Quantifications on boundary velocities, melt pool dimensions, thermal gradients, and cooling rates are performed, enabling future comprehensive melt pool dynamics and microstructure analysis. The study discovers a strong correlation between the thermal and X-ray data, demonstrating the feasibility of using relatively cheap IR cameras to predict features that currently can only be captured using costly synchrotron X-ray imaging. Such correlation can be used for future thermal-based melt pool control and model validation.

47 OTHER INSTRUMENTATION↗

Preliminary study of the reliability of imaging charge coupled devices

Imaging CCDs are capable of low light level response and high signal-to-noise ratios. In space applications they offer the user the ability to achieve extremely high resolution imaging with minimum circuitry in the photo sensor array. This work relates the CCD121H Fairchild device to the fundamentals of CCDs and the representative technologies. Several failure modes are described, construction is analyzed and test results are reported. In addition, the relationship of the device reliability to packaging principles is analyzed and test data presented. Finally, a test program is defined for more general reliability evaluation of CCDs.

Beall, J. R.↗

Ballistic-Electron-Emission Microscope

Ballistic-electron-emission microscope (BEEM) employs scanning tunneling-microscopy (STM) methods for nondestructive, direct electrical investigation of buried interfaces, such as interface between semiconductor and thin metal film. In BEEM, there are at least three electrodes: emitting tip, biasing electrode, and collecting electrode, receiving current crossing interface under investigation. Signal-processing device amplifies electrode signals and converts them into form usable by computer. Produces spatial images of surface by scanning tip; in addition, provides high-resolution images of buried interface under investigation. Spectroscopic information extracted by measuring collecting-electrode current as function of one of interelectrode voltages.

Kaiser, William J.↗

Emerging standards for still image compression: A software implementation and simulation study

The software implementation is described of an emerging standard for the lossy compression of continuous tone still images. This software program can be used to compress planetary images and other 2-D instrument data. It provides a high compression image coding capability that preserves image fidelity at compression rates competitive or superior to most known techniques. This software implementation confirms the usefulness of such data compression and allows its performance to be compared with other schemes used in deep space missions and for data based storage.

Pollara, F.↗

BOREAS RSS-16 AIRSAR CM Images: Integrated Processor Version 6.1 Level-3b

The BOREAS RSS-16 team used satellite and aircraft SAR data in conjunction with various ground measurements to determine the moisture regime of the boreal forest. RSS-16 assisted with the acquisition and ordering of NASA JPL AIRSAR data collected from the NASA DC-8 aircraft. The NASA JPL AIRSAR is a side-looking imaging radar system that utilizes the SAR principle to obtain high resolution images that represent the radar backscatter of the imaged surface at different frequencies and polarizations. The information contained in each pixel of the AIRSAR data represents the radar backscatter for all possible combinations of horizontal and vertical transmit and receive polarizations (i.e., HH, HV, VH, and VV). Geographically, the data cover portions of the BOREAS SSA and NSA. Temporally, the data were acquired from 12-Aug-1993 to 31-Jul-1995. The level-3b AIRSAR CM data are in compressed Stokes matrix format, which has 10 bytes per pixel. From this data format, it is possible to synthesize a number of different radar backscatter measurements. The data are stored in binary image-format files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

Back-illuminated imager and method for making electrical and optical connections to same

Methods for bringing or exposing metal pads or traces to the backside of a backside-illuminated imager allow the pads or traces to reside on the illumination side for electrical connection. These methods provide a solution to a key packaging problem for backside thinned imagers. The methods also provide alignment marks for integrating color filters and microlenses to the imager pixels residing on the frontside of the wafer, enabling high performance multispectral and high sensitivity imagers, including those with extremely small pixel pitch. In addition, the methods incorporate a passivation layer for protection of devices against external contamination, and allow interface trap density reduction via thermal annealing. Backside-illuminated imagers with illumination side electrical connections are also disclosed.

Pain, Bedabrata↗

Development Status of Adjustable Grazing Incidence Optics for 0.5 Arcsecond X-Ray Imaging

We describe progress in the development of adjustable grazing incidence X-ray optics for 0.5 arcsec resolution cosmic X-ray imaging. To date, no optics technology is available to blend high resolution imaging like the Chandra X-ray Observatory, with square meter collecting area. Our approach to achieve these goals simultaneously is to directly deposit thin film piezoelectric actuators on the back surface of thin, lightweight Wolter-I or Wolter- Schwarschild mirror segments. The actuators are used to correct mirror figure errors due to fabrication, mounting and alignment, using calibration and a one-time figure adjustment on the ground. If necessary, it will also be possible to correct for residual gravity release and thermal effects on-orbit. In this paper we discuss our most recent results measuring influence functions of the piezoelectric actuators using a Shack-Hartmann wavefront sensor. We describe accelerated and real-time lifetime testing of the piezoelectric material, and we also discuss changes to, and recent results of, our simulations of mirror correction.

Reid, Paul B.↗

The Solar Orbiter SPICE Instrument An Extreme UV imaging spectrometer

Aims. The Spectral Imaging of the Coronal Environment (SPICE) instrument is a high-resolution imaging spectrometer operating at extreme ultraviolet wavelengths. In this paper, we present the concept, design, and pre-launch performance of this facility instrument on the ESA/NASA Solar Orbiter mission. Methods. The goal of this paper is to give prospective users a better understanding of the possible types of observations, the data acquisition, and the sources that contribute to the instrument’s signal. Results. The paper discusses the science objectives, with a focus on the SPICE-specific aspects, before presenting the instrument’s design, including optical, mechanical, thermal, and electronics aspects. This is followed by a characterisation and calibration of the instrument’s performance. The paper concludes with descriptions of the operations concept and data processing. Conclusions. The performance measurements of the various instrument parameters meet the requirements derived from the mission’s science objectives. The SPICE instrument is ready to perform measurements that will provide vital contributions to the scientific success of the Solar Orbiter mission.

M. Anderson↗

High speed techniques for synthetic aperture radar image formation

One possible approach to high speed synthetic aperture radar signal reconstruction involves the utilization of two dimensional real time spatial light modulators as recyclable replacements for photographic film in the input transducer plane of a modified synthetic aperture radar (SAR) coherent optical processor. Leading candidate spatial light modulators include modified Pockels readout optical modulators (PROM), charge coupled devices (CCD) addressed liquid crystal light valves, and CCD addressed membrane light modulators. The fundamental physical limitations affecting SAR processor performance characteristics of such real time devices are under investigation. Current research on PROM is focused on the effects of device operatonal mode, device constitutive parameters, electro-optic crystal orientation, writing wavelength, frame rate/data overwrite/presuming, erasure completeness, and image retention on the overall quality of SAR image formation. Both modulated laser scanning and intensified CRT temporal to spatial input approaches are being examined.

Psaltis, D.↗

Nanoscopic Imaging of Self-Propelled Ultrasmall Catalytic Nanomotors

Ultrasmall nanomotors (<100 nm) are highly desirable nanomachines for their size-specific advantages over their larger counterparts in applications spanning nanomedicine, directed assembly, active sensing, and environmental remediation. While there are extensive studies on motors larger than 100 nm, the design and understanding of ultrasmall nanomotors have been scant due to the lack of high-resolution imaging of their propelled motions with orientation and shape details resolved. Here, we report the imaging of the propelled motions of catalytically powered ultrasmall nanomotors─hundreds of them─at the nanometer resolution using liquid-phase transmission electron microscopy. These nanomotors are Pt nanoparticles of asymmetric shapes (“tadpoles” and “boomerangs”), which are colloidally synthesized and observed to be fueled by the catalyzed decomposition of NaBH4 in solution. Statistical analysis of the orientation and position trajectories of fueled and unfueled motors, coupled with finite element simulation, reveals that the shape asymmetry alone is sufficient to induce local chemical concentration gradient and self-diffusiophoresis to act against random Brownian motion. Our work elucidates the colloidal design and fundamental forces involved in the motions of ultrasmall nanomotors, which hold promise as active nanomachines to perform tasks in confined environments such as drug delivery and chemical sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗