Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Observations of joule and particle heating in the auroral zone

Observational data from the Chatanika, Alaska incoherent scatter radar have been used to deduce atmospheric heating rates associated with particle precipitation and joule dissipation. During periods when Chatanika is in the vicinity of the auroral oval the height-integrated heat input to the lower thermosphere can be as large as 100 ergs per sq cm per sec with joule and particle heating rates of comparable magnitude. Altitude profiles of these heat inputs are also obtained, showing that the energy liberated by joule dissipation tends to peak at a substantially higher altitude (about 130 km) than that due to particles (100-120 km). As a consequence, it follows that joule heating can be expected to provide a rapid means for creating thermospheric disturbances. It is also pointed out that joule and particle heating are permanent features of the auroral oval and polar cap. As such, expansion of the auroral oval leads to an increase in the total global heating and, hence, to the close relationship between magnetic disturbances and thermospheric perturbation.

Banks, P. M.↗

A structured surface for high performance evaporative heat transfer

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open faced screw thread surfaces. With a groove density of 12.6/cm and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm K have been measured, along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm K at 20 W/sq cm was measured with a 37.8/cm hybrid surface.

Saaski, E. W.↗

Study of a high performance evaporative heat transfer surface

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open-faced screw thread surfaces. With a groove density of 12.6 cm/1 and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm have been measured along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm was measured with a 37.8 cm/1 hybrid surface.

Saaski, E. W.↗

The SRB heat shield: Aeroelastic stability during reentry

Wind tunnel tests of a 3% scale model of the aft portion of the SRB equipped with partially scaled heat shields were conducted for the purpose of measuring fluctuating pressure levels in the aft skirt region. During these tests, the heat shields were observed to oscillate violently, the oscillations in some instances causing the heat shields to fail. High speed films taken during the tests reveal a regular pattern of waves in the fabric starting near the flow stagnation point and progressing around both sides of the annulus. The amplitude of the waves was too great, and their pattern too regular, for them to be attributed to the fluctuating pressure levels measured during the tests. The cause of the oscillations observed in the model heat shields, and whether or not similar oscillations will occur in the full scale SRB heat shield during reentry were investigated. Suggestions for modifying the heat shield so as to avoid the oscillations are provided, and recommendations are made for a program of vibration and wind tunnel tests of reduced-scale aeroelastic models of the heat shield.

Ventres, C. S.↗

Heat pipes in space and on earth

The performance of heat pipes used in the thermal control system of spacecraft such as OAO-III and ATS-6 is discussed, and applications of heat pipes to permafrost stabilization on the Alaska Pipeline and to heat recovery systems are described. Particular attention is given to the ATS-6, launched in 1974, which employs 55 heat pipes to carry solar and internal power loads to radiator surfaces. In addition, experiments involving radiative cooling based on cryogenic heat pipes have been planned for the Long Duration Exposure Facility spacecraft and for Spacelab. The role of heat pipes in Space Shuttle heat rejection services is also mentioned.

Ollendorf, S.↗

Prediction of orbiter RSI tile gap heating ratios from NASA/Ames double wedge model test

In-depth gap heating ratios for Orbiter RSI tile sidewalls were predicted based on near steady state temperature measurements obtained from double wedge model tests. An analysis was performed to derive gap heating ratios which would result in the best fit of test data; provide an assessment of open gap response, and supply the definition of gap filler requirements on the Orbiter. A comparison was made of these heating ratios with previously derived ratios in order to verify the extrapolation of the wing glove data to Orbiter flight conditions. The analysis was performed with the Rockwell TPS Multidimensional Heat Conduction Program for a 3-D, 2.0-inch thick flat RSI tile with 255 nodal points. The data from 14 tests was used to correlate with the analysis. The results show that the best-fit heating ratios at the station farthest upstream on the model for most gap depths were less than the extrapolated values of the wing glove model heating ratios. For the station farthest downstream on the model, the baseline heating ratios adequately predicted or over-predicted the test data.

Source record↗

Prediction of in-depth gap heating ratios from wing glove model test data

In-depth gap heating ratios were predicted down RSI tile sidewalls based on temperature measurements obtained from the JSC arc-jet Wing Glove model tests in order to develop gap heating ratios which resulted in the best possible fit of test data and to produce a set of engineering verification heating ratios similar in shape to one another which could be used at various body points on the Orbiter during reentry. The Rockwell TPS Multidimensional heat conduction program was used to perform 3-D thermal analyses using a 3.0 in. thick section of a curved RSI tile with 283 nodal points. Correlation with test data shows that the predicted heating ratios were significantly higher down in the gap than the zero pressure values for T/C stacks 39 and 38 on the Wing Glove model. For stack 37 (in a low pressure region), the baseline heating ratio overpredicted the temperature data. This analysis, which showed that the heating ratios were a strong function of the product of pressure and pressure gradient, will be used to compare with recent Gap/Step and Ames Double Wedge test/analysis results in the effort to identify the Orbiter gap response to high delta P flight environment.

Source record↗

A Conceptual Design Study on the Application of Liquid Metal Heat Transfer Technology to the Solar Thermal Power Plant

Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.

Zimmerman, W. F.↗

Depriming of arterial heat pipes: An investigation of CTS thermal excursions

Four thermal excursions of the Transmitter Experiment Package (TEP) were the result of the depriming of the arteries in all three heat pipes in the Variable Conductance Heat Pipe System which cooled the TEP. The determined cause of the depriming of the heat pipes was the formation of bubbles of the nitrogen/helium control gas mixture in the arteries during the thaw portion of a freeze/thaw cycle of the inactive region of the condenser section of the heat pipe. Conditions such as suction freezeout or heat pipe turn-on, which moved these bubbles into the active region of the heat pipe, contributed to the depriming mechanism. Methods for precluding, or reducing the probability of, this type of failure mechanism in future applications of arterial heat pipes are included.

Antoniuk, D.↗

Radiator heat rejection options for Shuttle payloads

The paper describes four separate advanced space radiator concepts that have been pursued in an integrated effort to develop multipayload use, low-cost heat rejection systems which can overcome the limitations of current radar systems. These four concepts are the following: (1) a wide heat load range, modularized space radiation system; (2) a heat rejection subsystem designed as a compact self-contained heat rejection module which provides a refrigeration cycle to accomodate a wide variation in payload heat loads and cooling temperature requirements; (3) a lightweight flexible fin radiator system with heat rejection capability; and (4) a radiator which does not require a circulating coolant on the radiator panel with heat pipes and thus particularly applies to very-long-duration free-flying payloads where long life reliability is an overriding design parameter. The Orbiter active thermal control system is briefly described.

Ellis, W. E.↗

Photocell heat engine solar power systems

A combined photocell heat engine concept is proposed for high efficiency solar energy conversion in space. In this concept the short wavelength portion of the solar spectrum is split by a dichroic filter and sent to a bank of photocells. The long wave-length remainder of the spectrum is used by the heat engine. This technique allows the photocells to operate with the minimum amount of waste heat, increasing their efficiency and reducing the amount of cooling required. The heat engine operates by direct absorption in a working fluid containing broadband absorber molecules or particulates. A window in the heat engine admits the long wave-lengths from the solar spectrum. The window may also reflect a portion of the internal gaseous reradiation spectrum (e.g., a heat mirror) to help reduce radiation losses. Flow-induced thermal gradients may also reduce reradiation losses in the case of optically thick working fluids. The efficiencies computed for the photocell heat engine solar energy converter can be as high as 42 percent.

Taussig, R. T.↗

A new method of efficient heat transfer and storage at very high temperatures

A unique, high temperature (1000-2000 K) continuously operating capacitive heat exchanger system is described. The system transfers heat from a combustion or solar furnace to a working gas by means of a circulating high temperature molten refractory. A uniform aggregate of beads of a glass-like refractory is injected into the furnace volume. The aggregate is melted and piped to a heat exchanger where it is sprayed through a counter-flowing, high pressure working gas. The refractory droplets transfer their heat to the gas, undergoing a phase change into the solid bead state. The resulting high temperature gas is used to drive a suitable high efficiency heat engine. The solidified refractory beads are delivered back to the furnace and melted to continue the cycle. This approach avoids the important temperature limitations of conventional tube-type heat exchangers, giving rise to the potential of converting heat energy into useful work at considerably higher efficiencies than currently attainable and of storing energy at high thermodynamic potential.

Shaw, D.↗

Electromagnetic heating of Io

The electromagnetic heating of the Io interior is considered as an alternative to tidal dissipation to account for the observed volcanic activity. The characteristics of the time-varying magnetic field of Jupiter as seen from Io are discussed, and the range of possible rock conductivities is examined. Interior heating due to the transverse electric and transverse magnetic modes is calculated. It is found that the TM mode appears to be insignificant as a heating source due to the high conductivity of the ionosphere, even when TM heating is concentrated in local hot regions. The TE mode is a more promising source of heating, although electromagnetic heating by either mode does not appear significant in comparison with other heat sources at present.

Colburn, D. S.↗

Anomalous heating of the polar E region by unstable plasma waves. II - Theory

It is found that anomalous electron temperatures in the disturbed high-latitude E region can be quantitatively explained in terms of heating by unstable plasma waves. The electron temperatures at 110 km have been measured to be as high as 1500 K instead of the expected value of about 300 K. It is shown that by using quasi-linear theory there is an ample source of heat in the unstable waves and that the measured electron temperature profiles have a shape very similar to what is expected from plasma wave heating by the modified two-stream instability. It is found that there is even more heating going to the ion gas, but that the resulting effect on the ion temperature may be difficult to measure. The best estimate of the wave heating rates leads to the conclusion that wave heating can be as much as 50% of the Joule heating for dc electric field strengths of the order of 45 mV/m or greater.

St.-Maurice, J. P.↗

Experimental Study of Fuel Heating at Low Temperatures in a Wing Tank Model, Volume 1

Scale model fuel heating systems for use with aviation hydrocarbon fuel at low temperatures were investigated. The effectiveness of the heating systems in providing flowability and pumpability at extreme low temperature when some freezing of the fuel would otherwise occur is evaluated. The test tank simulated a section of an outer wing tank, and was chilled on the upper and lower surfaces. Turbine engine lubricating oil was heated, and recirculating fuel transferred the heat. Fuels included: a commercial Jet A; an intermediate freeze point distillate; a higher freeze point distillate blended according to Experimental Referee Broadened Specification guidelines; and a higher freeze point paraffinic distillate used in a preceding investigation. Each fuel was chilled to selected temperature to evaluate unpumpable solid formation (holdup). Tests simulating extreme cold weather flight, without heating, provided baseline fuel holdup data. Heating and recirculating fuel increased bulk temperature significantly; it had a relatively small effect on temperature near the bottom of the tank. Methods which increased penetration of heated fuel into the lower boundary layer improved the capability for reducing holdup.

Stockemer, F. J.↗

A heat exchanger computational procedure for temperature-dependent fouling

A novel heat exchanger computational procedure is described which provides a means of rapidly calculating the distributions of fluid and wall temperatures, deposit formation, and pressure loss at various points in a heat exchanger. The procedure is unique in that it is capable of treating wide variations in heat exchanger geometry without recourse to restrictive assumptions concerning heat exchanger type (e.g., co-flow, counterflow, cross flow devices, etc.). The analysis has been used extensively to predict the performance of cross-counterflow heat exchangers in which one fluid behaves as a perfect gas (e.g., air) while the other fluid is assumed to be a distillate fuel. The model has been extended to include the effects on heat exchanger performance of time varying inflow conditions. Heat exchanger performance degradation due to deposit formation with time can be simulated, making this procedure useful in predicting the effects of temperature-dependent fouling.

Chiappetta, L. M.↗

On the theory of coronal heating mechanisms

The present state-of-the-art of two classes of theories of coronal heating is examined: (1) heating by acoustic processes in the 'nonmagnetic' parts of the atmosphere (the shock-wave theory is an example); and (2) heating by electrodynamic processes in the magnetic regions of the corona (beta much less than 1) either by MHD waves or current heating in regions with high electric current densities (flare-type heating). It is concluded that the mechanism of the heating of the solar chromosphere and corona remains an open question, especially in explaining detailed atmospheric structures. The acoustic theory might be correct with little modification for most of the chromosphere, but as soon as the atmosphere shows a high degree of structure as in the corona and transition layer the magnetic field must play a dominant role. It appears that the current heating theories have a small range of applicability, while the MHD-wave theories are the most promising.

Kuperus, M.↗

A study of aerodynamic heating distributions on a tip-fin controller installed on a Space Shuttle Orbiter model

The aerodynamic heating of a tip-fin controller mounted on a Space Shuttle Orbiter model was studied experimentally in the Calspan Advanced Technology Center 96 inch Hypersonic Shock Tunnel. A 0.0175 scale model was tested at Mach numbers from 10 to 17.5 at angles of attack typical of a shuttle entry. The study was conducted in two phases. In phase 1 testing a thermographic phosphor technique was used to qualitatively determine the areas of high heat-transfer rates. Based on the results of this phase, the model was instrumented with 40 thin-film resistance thermometers to obtain quantitative measurements of the aerodynamic heating. The results of the phase 2 testing indicate that the highest heating rates, which occur on the leading edge of the tip-fin controller, are very sensitive to angle of attack for alpha or = 30 deg. The shock wave from the leading edge of the orbiter wing impinges on the leading edge of the tip-fin controller resulting in peak values of h/h(Ref) in the range from 1.5 to 2.0. Away from the leading edge, the heat-transfer rates never exceed h/h(Ref) = 0.25 when the control surface, is not deflected. With the control surface deflected 20 deg, the heat-transfer rates had a maximum value of h/h(Ref) = 0.3. The heating rates are quite nonuniform over the outboard surface and are sensitive to angle of attack.

Wittliff, C. E.↗