Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grazing incidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The X-Ray Polarimeter Instrument on Board the Polarimeter for Relativistic Astrophysical X-Ray Sources (PRAXyS) Mission

The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study. The PRAXyS observatory carries an X-ray Polarimeter Instrument (XPI) capable of measuring the linear polarization from a variety of high energy sources, including black holes, neutron stars, and supernova remnants. The XPI is comprised of two identical mirror-Time Projection Chamber (TPC) polarimeter telescopes with a system effective area of 124 sq cm at 3 keV, capable of photon limited observations for sources as faint as 1 mCrab. The XPI is built with well-established technologies. This paper will describe the performance of the XPI flight mirror with the engineering test unit polarimeter

polarization↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview II

The Imaging X-ray Polarimetry Explorer (IXPE) will add polarization to the properties (time, energy, and position) observed in x-ray astronomy. A NASA Astrophysics Small Explorer (SMEX) in partnership with the Italian Space Agency (ASI), IXPE will measure the 2–8-keV polarization of a few dozen sources during the first 2 years following its 2021 launch. The IXPE Observatory includes three identical x-ray telescopes, each comprising a 4-m-focal-length (grazingincidence) mirror module assembly (MMA) and a polarization-sensitive (imaging) detector unit (DU), separated by a deployable optical bench. The Observatory’s Spacecraft provides typical subsystems (mechanical, structural, thermal, power, electrical, telecommunications, etc.), an attitude determination and control subsystem for 3-axis stabilized pointing, and a command and data handling subsystem communicating with the science instrument and the Spacecraft subsystems.

X-ray astronomy↗

A Review of Variable-impedance Acoustic Liner Concepts Developed at NASA

This paper presents results attained in the NASA Langley Research Center test rigs using acoustic liners for which the impedance varies over the liner surface. These liners are typically designed for significant sound absorption over a wide frequency range, but it is also possible to design them to achieve increased absorption at selected frequencies. A brief review is provided regarding a number of variable-impedance concepts. The first is a modified version of a conventional two-layer liner, in which the embedded septum location and flow resistance are different for adjacent core chambers. Two concepts employ core chambers with different lengths, one with bent chambers to allow packaging within a limited volume, and the other with shared inlet ports to reduce the surface porosity. The last employs a perforated facesheet in which the hole diameter and porosity are varied over the surface of the liner. Data acquired in the NASA normal incidence and grazing flow impedance tubes are used to demonstrate the capabilities of these concepts. Impedance prediction models are also presented for comparison with these measured data.

Michael G. Jones↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview IV

Scheduled to launch in late 2021,the Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission designed to open up a new window of investigation --X-ray polarimetry. The IXPE observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging x-ray detector at its focus. An extending boom, deployed on orbit, provides the necessary 4 m focal length. The payload sits atop a 3-axis stabilized spacecraft which, among other things, provides power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of x-ray sources, with follow-on observations of selected targets. IXPE is a partnership between NASA and the Italian Space Agency (ASI).

X-ray polarimetry↗

Initial Findings in Full-Shell Active Optics

The realization of active full-shell x-ray optics will provide ground-breaking capability for future missions. Future X-ray missions, such as Lynx, require high angular-resolution, large effective area, and as wide a field of view(FOV) as possible. It is currently not possible to perform high-resolution imaging of both wide and narrow FOVs with a single X-ray telescope. In this paper, we discuss the use of actuators to switch the optical surface of full-shell x-ray optics between prescriptions optimized for narrow-field and wide-field viewing, as well as correct for low-spatial-frequency errors in the optics. Previously, a pathfinder was developed using finite-element modeling(FEM). Using a combination of the model’s influence functions, the capacity of active full-shell optics was shown to switch between prescriptions with 92% accuracy. Another benefit of the analytical pathfinder was its ability to correct low-spatial frequency errors, which comprise a large percentage of the MSFC full-shell x-ray optics root-mean-square (RMS) slope error. In order to verify the pathfinder, a surface-parallel actuator was bonded to a nickel-replicated coupon. After the actuator was bonded to the coupon, the slope of the surface was measured while the actuator was activated. The proof-of-concept demonstrator development, the influence function data, and the resulting implications on the analytical pathfinder are reported and discussed.

X-ray optics↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Multilayer X-ray mirrors - Interfacial roughness, scattering, and image quality

Scattering of the multilayer coatings used for our normal incidence soft X-ray telescope at a wavelength of 63.5 A has been measured at 1.54 A and grazing angles of incidence and at soft X-rays near normal incidence. Furthermore, the edge of the moon is used as a known test target to estimate the amount of scattering in the arcsec range from images obtained on the date of the solar eclipse on July 11, 1991. The internal surfaces of the coating are inspected by high-resolution electron microscopy. A theoretical model describing the evolution and replication of roughness from layer to layer throughout the structure, which is in agreement with all experimental data, is presented. We find that practically all roughness caused by the growth of the multilayer structure occurs at spatial frequencies which are too high to produce scattering. The substrate roughness is replicated at lower spatial frequencies which might produce scattering within the field of view of an instrument. However, roughness in this range is below the 0.5 A level, again resulting in insignificant amounts of scatter.

Spiller, Eberhard↗

Effects of Liner Geometry on Acoustic Impedance

Current aircraft engine nacelles typically contain acoustic liners consisting of perforated sheets bonded onto honeycomb cavities. Numerous models have been developed to predict the acoustic impedance of these liners in the presence of grazing flow, and to use that information with aeroacoustic propagation codes to assess nacelle liner noise suppression. Recent efforts have provided advances in impedance education methodologies that offer more accurate determinations of acoustic liner properties in the presence of grazing flow. The current report provides the results of a parametric study, in which a finite element method was used to assess the effects of variations of the following geometric parameters on liner impedance, with and without the presence of grazing flow: percent open area, sheet thickness, sheet thickness-to-hole diameter ratio and cavity depth. Normal incidence acoustic impedances were determined for eight acoustic liners, consisting of punched aluminum facesheets bonded to hexcell honeycomb cavities. Similar liners were tested in the NASA Langley Research Center grazing incidence tube to determine their response in the presence of grazing flow. The resultant data provide a quantitative assessment of the effects of these perforate, single-layer liner parameters on the acoustic impedance of the liner.

Jones, Michael G.↗

The effects of particle size on the optical properties and surface roughness of a glass-balloon-filled black paint

The effects of particle size on the optical properties and surface roughness of a glass-balloon-filled, carbon-pigmented paint were studied in order to develop a diffuse-reflecting, low-total-reflectance, low-outgassing black paint. Particle sizes ranged between 20 microns and 74 microns. Surface roughness was found to increase with increasing particle size. Relative total reflectance at near-normal incidence (MgO standard) of the filled paints was less than for the unfilled paint between 230 nm and 1800 nm. Total absolute reflectance at 546 nm decreased with increasing particle size at grazing angles of incidence. Near-normal, total emittance was greater for the filled paints than for the unfilled paint. Specularity decreased with increasing particle size over the range studied.

Heslin, T.↗

Effects of surface undulations on asymmetric X-ray diffraction: a rocking-curve topography study

The results are reported of an X-ray diffraction study of an Si crystal designed and fabricated for very asymmetric diffraction from the 333 reflection for X-ray energies of 8.100 and 8.200 keV. A crystal with an asymmetry angle of 46 ± 0.1° between the surface and the (111) planes was studied. The grazing angles of incidence were near 1.08 and 0.33° for these two energies, respectively. Features arising from surface undulations were not observed at 8.100 keV, but were observed at 8.200 keV. The results at 8.100 keV allow an alternative explanation based on strain near the surface to be ruled out. Topographic images were obtained as a function of rocking angle, and in the case of 8.200 keV the surface morphology is evident. Finally, the results are found to be in agreement with dynamical X-ray diffraction calculations made with the Takagi–Taupin equations specialized to a surface having convex or concave features, as reported in the accompanying paper [Macrander (2020). J. Appl. Cryst. 53 , 793–799].

36 MATERIALS SCIENCE↗

Radiative property investigation

Measurements of the bidirectional reflections of NASA paints Z-93 and S-13G were made for 0.5, 1.78, and 2.5 microns, source incidence angles of 0, 30, 60, and 75 deg, and four detector azimuth positions. The bidirectional reflectance distribution was found to be near Lambert for azimuth positions not to close to 180 deg from the source incident azimuth. The reflectance distribution at an azimuth of 180 deg from the source is close to Lambert for near normal source incidents angles, and becomes much larger than Lambert as the source incident angle approach grazing. The reflectance deviates from Lambert as the wavelength increases. Comparison of data for the paints shows Z-93 reflectance is much closer to Lambert than S-13G. When there is a peak in the reflectance distribution it occurred at the specular angle or an angle larger than the specular angle.

Scott, R. L., Jr.↗

Diffractoid grating configuration for X-ray and ultraviolet focusing

An aspheric grating is described which is operable to image local or distant point sources sharply in a designated wavelength, i.e., produce a perfectly stigmatic image in the given wavelength at grazing angles of incidence. The grating surface comprises a surface of revolution defined by a curve which does not have a constant radius of curvature but is defined by a nonlinear differential equation.

Kastner, S. O.↗