Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A comparison of probabilistic generative frameworks for molecular simulations

Generative artificial intelligence is now a widely used tool in molecular science. Despite the popularity of probabilistic generative models, numerical experiments benchmarking their performance on molecular data are lacking. Here, in this work, we introduce and explain several classes of generative models, broadly sorted into two categories: flow-based models and diffusion models. We select three representative models: neural spline flows, conditional flow matching, and denoising diffusion probabilistic models, and examine their accuracy, computational cost, and generation speed across datasets with tunable dimensionality, complexity, and modal asymmetry. Our findings are varied, with no one framework being the best for all purposes. In a nutshell, (i) neural spline flows do best at capturing mode asymmetry present in low-dimensional data, (ii) conditional flow matching outperforms other models for high-dimensional data with low complexity, and (iii) denoising diffusion probabilistic models appear the best for low-dimensional data with high complexity. Our datasets include a Gaussian mixture model and the dihedral torsion angle distribution of the Aib9 peptide, generated via a molecular dynamics simulation. We hope our taxonomy of probabilistic generative frameworks and numerical results may guide model selection for a wide range of molecular tasks.

Artificial intelligence↗

UNF-ST&DARDS Unified Database and the Automatic Document Generator

The U.S. Department of Energy, Office of Nuclear Energy is sponsoring development of a database to store information related to spent nuclear fuel (SNF) in support of its Spent Fuel and Waste Disposition efforts. This database, referred to as the Unified Database (UDB), is part of a larger engineering analysis tool, the Used Nuclear Fuel Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). The UDB provides a comprehensive, controlled source of SNF information, including dry cask attributes, assembly data, economic attributes, transportation infrastructure attributes, potential future facility attributes, and federal government radioactive waste attributes. There are a number of existing and envisioned data reports that can be expected to use data stored within the UDB; however, previously, there was not a streamlined method to couple the database to such data reports. Therefore, to streamline the creation of these reports, two methods were developed to generate documents from information in the database automatically. The first method used Java and LaTeX for automatically generating the report, and the second method used the Python programming language along with Sphinx, a Python documentation generator. There are some advantages and disadvantages to both approaches, but both methods produced equally high-quality, automatically generated reports that were directly coupled to the database. Finally, this study describes data currently available in the UDB; explains the two different methods for automatically generating reports from these data; and shows examples of inline text, figures, and tables automatically generated using both approaches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generation of magnetic field on the accretion disk around a proto-first-star

The generation process of a magnetic field around a proto-first-star is studied. Utilizing the recent numerical results of proto-first-star formation based on radiation hydrodynamics simulations, we assess the magnetic field strength generated by the radiative force and the Biermann battery effect. We find that a magnetic field of ∼10{sup –9} G is generated on the surface of the accretion disk around the proto-first-star. The field strength on the accretion disk is smaller by two orders of magnitude than the critical value, above which the gravitational fragmentation of the disk is suppressed. Thus, the generated seed magnetic field hardly affect the dynamics of on-site first star formation directly, unless an efficient amplification process is taken into consideration. We also find that the generated magnetic field is continuously blown out from the disk on the outflows to the poles, that are driven by the thermal pressure of photoheated gas. The strength of the diffused magnetic field in low-density regions is ∼10{sup –14}-10{sup –13} G at n {sub H} = 10{sup 3} cm{sup –3}, which could play an important role in the next generation star formation, as well as the seeds of the magnetic field in the present-day universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation mechanism of the slowly drifting narrowband structure in the type IV solar radio bursts observed by AMATERAS

We investigate the type IV burst event observed by AMATERAS on 2011 June 7, and reveal that the main component of the burst was emitted from the plasmoid eruption identified in the EUV images of the Solar Dynamics Observatory (SDO)/AIA. We show that a slowly drifting narrowband structure (SDNS) appeared in the burst's spectra. Using statistical analysis, we reveal that the SDNS appeared for a duration of tens to hundreds of milliseconds and had a typical bandwidth of 3 MHz. To explain the mechanism generating the SDNS, we propose wave-wave coupling between Langmuir waves and whistler-mode chorus emissions generated in a post-flare loop, which were inferred from the similarities in the plasma environments of a post-flare loop and the equatorial region of Earth's inner magnetosphere. We assume that a chorus element with a rising tone is generated at the top of a post-flare loop. Using the magnetic field and plasma density models, we quantitatively estimate the expected duration of radio emissions generated from coupling between Langmuir waves and chorus emissions during their propagation in the post-flare loop, and we find that the observed duration and bandwidth properties of the SDNS are consistently explained by the proposed generation mechanism. While observations in the terrestrial magnetosphere show that the chorus emissions are a group of large-amplitude wave elements generated naturally and intermittently, the mechanism proposed in the present study can explain both the intermittency and the frequency drift in the observed spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Full suppression of runaway electron generation by the mode penetration of resonant magnetic perturbations during disruptions on J-TEXT

The avoidance and suppression of runaway electron (RE) generation during disruptions is of great importance for the safe operation of tokamaks. Massive gas injection is enacted to suppress the generation of REs, but the poor gas mixing efficiency and extremely high density required to suppress RE generation make the full RE suppression unreliable. The magnetic perturbations provide an alternative RE suppression during disruptions. The use of mode penetration induced by resonant magnetic perturbations (RMPs) to suppress RE generation has been investigated on the J-TEXT tokamak. For a sufficiently long mode penetration duration, robust runaway suppression has been reached during the disruptions. The m/n = 2/1 mode RMP with high amplitude excites large magnetic islands inside the plasma and leads to the large-scale destruction of magnetic surfaces during disruptions, which results in RE loss and runaway-free disruptions. The essential island width required for runaway suppression is estimated to be larger than 0.16 as the minor radius. This value might be slightly underestimated because of the misalignment between the electron cyclotron emission diagnostic and the island O-point. NIMROD simulations are used to investigate the effect of magnetic islands on RE generation during disruption, showing that the large magnetic islands have the ability to enhance RE seed loss during disruptions. RMP can excite large magnetic islands in the target plasma without tearing mode and might be a way to prevent RE generation during disruptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DCTRGAN: improving the precision of generative models with reweighting

Significant advances in deep learning have led to more widely used and precise neural network-based generative models such as Generative Adversarial Networks (Gans). We introduce a post-hoc correction to deep generative models to further improve their fidelity, based on the Deep neural networks using the Classification for Tuning and Reweighting (Dctr) protocol. The correction takes the form of a reweighting function that can be applied to generated examples when making predictions from the simulation. We illustrate this approach using Gans trained on standard multimodal probability densities as well as calorimeter simulations from high energy physics. We show that the weighted Gan examples significantly improve the accuracy of the generated samples without a large loss in statistical power. This approach could be applied to any generative model and is a promising refinement method for high energy physics applications and beyond.

47 OTHER INSTRUMENTATION↗

Shaping attosecond pulses by controlling the minima in high-order harmonic generation through alignment of CO 2 molecules

In this paper, we report a simple method for generating shaped attosecond pulses by using a CO 2 molecule. Unlike most other molecules, owing to its unique energy and angle dependence and the presence of deep minima in the photoionization transition dipole moment, the shape of harmonic spectra, especially the position and depth of minima, can be readily controlled by tuning the degree of alignment. The sensitive alignment dependence of the minima is due to the coherent interference of a laser-induced dipole from each molecule when CO 2 molecules are moderately aligned, but not when they are well aligned or when they are isotropically distributed. Such a sensitivity offers a simple way of controlling the spectral amplitude and phase of the generated harmonics and thus shaping the generated attosecond pulses, for example, producing structured attosecond pulses by splitting a single burst into two. We illustrate how such pulses are generated and how to characterize them. This method offers a simple way to shape attosecond pulses at the generation step. It can be easily implemented experimentally to generate attosecond pulses with strong phase variations for unique applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

PV Generation Enhancement with a Virtual Inertia Emulator to Provide Inertial Response to the Grid

With high-penetration levels of renewable generating sources being integrated into the existing electric power grid, conventional generators are being replaced and grid inertial response is deteriorating. This technical challenge is more severe with photovoltaic (PV) generation than with wind generation because PV generation systems cannot provide inertial response unless special countermeasures are adopted. To enhance the inertial response, this paper proposes to synthesize a virtual inertia emulator (VIE) by using a battery energy storage system (BESS) and a three-phase grid-tied inverter to simulate a traditional generator such that the inertial response can be appropriately enhanced without sacrificing energy efficiency. Control systems for the VIE are presented in this paper, along with simulation results from PSCAD and MATLAB to validate the effectiveness of the proposed scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FL-DISCO: Federated Generative Adversarial Network for Graph-based Molecule Drug Discovery: Special Session Paper

The outbreak of the global COVID-19 pandemic emphasizes the importance of collaborative drug discovery for high effectiveness; however, due to the stringent data regulation, data privacy becomes an imminent issue needing to be addressed to enable collaborative drug discovery. In addition to the data privacy issue, the efficiency of drug discovery is another key objective since infectious diseases spread exponentially and effectively conducting drug discovery could save lives. Advanced Artificial Intelligence (AI) techniques are promising to solve these problems: (1) Federated Learning (FL) is born to keep data privacy while learning data from distributed clients; (2) graph neural network (GNN) can extract structural properties of molecules whose underlying architecture is the connected atoms; and (3) generative adversarial network (GAN) can generate novel molecules while retaining the properties learned from the training data. In this work, we make the first attempt to build a holistic collaborative and privacy-preserving FL framework, namely FL- DISCO, which integrates GAN and GNN to generate molecular graphs. Experimental results demonstrate the effectiveness of FL- DISCO on: (1) IID data for ESOL and QM9, where FL-DISCO can generate highly novel compounds with high drug-likeliness, uniqueness and LogP scores compared to the baseline; (2) non- IID data for ESOL and QM9, where FL-DISCO generates 100% novel compounds with high validity and LogP scores compared to the baseline. We also demonstrate how different fractions of clients, generator and discriminator architectures affect our evaluation scores.

Manu, Daniel↗

Structured Neural Network Modeling for Developing Digital Twins Models of Hydropower Generation Units

Dynamic modeling is a key part in the development of digital twin (DT) for dynamic systems. This is true for hydropower systems, where whole system modeling including penstock, turbine and generators, etc is important in realizing actuate modeling for the real systems. On the other hand, in response to the large variations of the power demand due to increased penetration of renewables such as wind and solar, hydropower systems are now required to operate in a large power generation range. This situation triggers the nonlinear characteristics of the generation unit with respect to its models. As such, it is imperative to use data driven modeling such as neural networks to learn the nonlinear dynamics of the hydropower generation unit. To achieve this objective, this study constructs a modeling and learning algorithm integrated with multiple structured neural network models for the modeling of turbine shaft speed, penstock pressure, and generator power output based on the generator power control setpoint, field current, and field voltage. In addition, the study uses the hydropower data from Tacoma Public Utilities to train and validate the proposed neural network algorithm. The results have shown that this structured neural network modeling approach can learn the system dynamics effectively by using the real-time data collected from the hydropower system with the desired modeling results.

Wang, Hong↗

Understanding SYCL Portability for Pseudorandom Number Generation: a Case Study with Gene-Expression Connectivity Mapping

Towards the goal of improving functional and performance portability of SYCL, we study a bioinformatics application that has been accelerated with CUDA and fast pseudorandom number generation on a GPU. We describe the experience of migrating pseudorandom number generation from CUDA to SYCL, evaluate the performance of pseudorandom number generators using the CUDA random number generation library, suggest the support of the XORWOW pseudorandom number generator in the oneAPI math kernel library (oneMKL) interface for performance portability, and identify the performance gap using the MKL interface in SYCL that supports pseudorandom number generation with third-party libraries. We hope that the results are valuable for the development of the SYCL ecosystem.

Jin, Zheming↗

Model-free Load Control for High Penetration of Solar Photovoltaic Generation

This paper presents a new model-free control (MFC) mechanism that enables the local distribution level circuit consumption of the photovoltaic (PV) generation by local building loads, in particular, distributed heating, ventilation and air conditioning (HVAC) units. The local consumption of PV generation will help minimize the impact of PV generation on the distribution grid, reduce the required battery storage capacity for PV penetration, and increase solar PV generation penetration levels. The proposed MFC approach with its corresponding intelligent controllers does not require any precise modeling for buildings, where their reliable modeling is a demanding task. Even when assuming the availability of a good model, the various building architectures would compromise the performance objectives of any model-based control strategy. The objective is to consume most of the PV generation locally while maintaining occupants comfort and physical constraints of HVAC units. That is, by enabling proper scheduling of responsive loads temporally and spatially to minimize the difference between demand and PV production, it would be possible to reduce voltage variations and two-way power flow. Computer simulations show promising results where a significant proportion of the PV generation can be consumed by building HVAC units with the help of intelligent control.

Bara, Ouassim↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

MO-G-304-04: Generating Well-Dispersed Representations of the Pareto Front for Multi-Criteria Optimization in Radiation Treatment Planning

Purpose: To present a novel multi-criteria optimization (MCO) solution approach that generates well-dispersed representation of the Pareto front for radiation treatment planning. Methods: Different algorithms have been proposed and implemented in commercial planning software to generate MCO plans for external-beam radiation therapy. These algorithms consider convex optimization problems. We propose a grid-based algorithm to generate well-dispersed treatment plans over Pareto front. Our method is able to handle nonconvexity in the problem to deal with dose-volume objectives/constraints, biological objectives, such as equivalent uniform dose (EUD), tumor control probability (TCP), normal tissue complication probability (NTCP), etc. In addition, our algorithm is able to provide single MCO plan when clinicians are targeting narrow bounds of objectives for patients. In this situation, usually none of the generated plans were within the bounds and a solution is difficult to identify via manual navigation. We use the subproblem formulation utilized in the grid-based algorithm to obtain a plan within the specified bounds. The subproblem aims to generate a solution that maps into the rectangle defined by the bounds. If such a solution does not exist, it generates the solution closest to the rectangle. We tested our method with 10 locally advanced head and neck cancer cases. Results: 8 objectives were used including 3 different objectives for primary target volume, high-risk and low-risk target volumes, and 5 objectives for each of the organs-at-risk (OARs) (two parotids, spinal cord, brain stem and oral cavity). Given tight bounds, uniform dose was achieved for all targets while as much as 26% improvement was achieved in OAR sparing comparing to clinical plans without MCO and previously proposed MCO method. Conclusion: Our method is able to obtain well-dispersed treatment plans to attain better approximation for convex and nonconvex Pareto fronts. Single treatment plan can be achieved when given bounds on the objectives.

60 APPLIED LIFE SCIENCES↗

WE-D-303-02: Applications of Volumetric Images Generated with a Respiratory Motion Model Based On An External Surrogate Signal

Purpose: Respiratory motion can vary significantly over the course of simulation and treatment. Our goal is to use volumetric images generated with a respiratory motion model to improve the definition of the internal target volume (ITV) and the estimate of delivered dose. Methods: Ten irregular patient breathing patterns spanning 35 seconds each were incorporated into a digital phantom. Ten images over the first five seconds of breathing were used to emulate a 4DCT scan, build the ITV, and generate a patient-specific respiratory motion model which correlated the measured trajectories of markers placed on the patients’ chests with the motion of the internal anatomy. This model was used to generate volumetric images over the subsequent thirty seconds of breathing. The increase in the ITV taking into account the full 35 seconds of breathing was assessed with ground-truth and model-generated images. For one patient, a treatment plan based on the initial ITV was created and the delivered dose was estimated using images from the first five seconds as well as ground-truth and model-generated images from the next 30 seconds. Results: The increase in the ITV ranged from 0.2 cc to 6.9 cc for the ten patients based on ground-truth information. The model predicted this increase in the ITV with an average error of 0.8 cc. The delivered dose to the tumor (D95) changed significantly from 57 Gy to 41 Gy when estimated using 5 seconds and 30 seconds, respectively. The model captured this effect, giving an estimated D95 of 44 Gy. Conclusion: A respiratory motion model generating volumetric images of the internal patient anatomy could be useful in estimating the increase in the ITV due to irregular breathing during simulation and in assessing delivered dose during treatment. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc. and Radiological Society of North America Research Scholar Grant #RSCH1206.

60 APPLIED LIFE SCIENCES↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗