Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Waste Generator Instructions: Key to Successful Implementation of the US DOE's 435.1 for Transuranic Waste Packaging Instructions (LA-UR-12-24155) - 13218

In times of continuing fiscal constraints, a management and operation tool that is straightforward to implement, works as advertised, and virtually ensures compliant waste packaging should be carefully considered and employed wherever practicable. In the near future, the Department of Energy (DOE) will issue the first major update to DOE Order 435.1, Radioactive Waste Management. This update will contain a requirement for sites that do not have a Waste Isolation Pilot Plant (WIPP) waste certification program to use two newly developed technical standards: Contact-Handled Defense Transuranic Waste Packaging Instructions and Remote-Handled Defense Transuranic Waste Packaging Instructions. The technical standards are being developed from the DOE O 435.1 Notice, Contact-Handled and Remote-Handled Transuranic Waste Packaging, approved August 2011. The packaging instructions will provide detailed information and instruction for packaging almost every conceivable type of transuranic (TRU) waste for disposal at WIPP. While providing specificity, the packaging instructions leave to each site's own discretion the actual mechanics of how those Instructions will be functionally implemented at the floor level. While the Technical Standards are designed to provide precise information for compliant packaging, the density of the information in the packaging instructions necessitates a type of Rosetta Stone that translates the requirements into concise, clear, easy to use and operationally practical recipes that are waste stream and facility specific for use by both first line management and hands-on operations personnel. The Waste Generator Instructions provide the operator with step-by-step instructions that will integrate the sites' various operational requirements (e.g., health and safety limits, radiological limits or dose limits) and result in a WIPP certifiable waste and package that can be transported to and emplaced at WIPP. These little known but widely productive Waste Generator Instructions (WGIs) have been used occasionally in the past at large sites for treatment and packaging of TRU waste. The WGIs have resulted in highly efficient waste treatment, packaging and certification for disposal of TRU waste at WIPP. For example, a single WGI at LANL, combined with an increase in gram loading, resulted in a mind boggling 6,400% increase in waste loading for {sup 238}Pu heat source waste. In fact, the WGI combined with a new Contact Handled (CH) TRU Waste Content (TRUCON) Code provided a massive increase in shippable wattage per Transuranic Package Transporter-II (TRUPACT-II) over the previously used and more restrictive TRUCON Code that have been used previously for the heat source waste. In fact, the use of the WGI process at LANL's TA-55 facility reduced non-compliant drums for WIPP certification and disposal from a 13% failure rate down to a 0.5% failure rate and is expected to further reduce the failure rate to zero drums per year. The inherent value of the WGI is that it can be implemented in a site's current procedure issuance process and it provides documented proof of what actions were taken for each waste stream packaged. The WGI protocol provides a key floor-level operational component to achieve goal alignment between actual site operations, the WIPP TRU waste packaging instructions, and DOE O 435.1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

K-25 D and D Challenges - 12170

Decontamination and decommissioning (D and D) of the K-25 former gaseous diffusion plant provides lessons learned applicable to other D and D projects in the DOE Complex. The 175,000- square-meter, 1.6-kilometer-long building is contaminated with highly enriched uranium (HEU), Tc-99, trace quantities of other fission products, asbestos, PCBs, and other hazardous wastes. Safety challenges include deteriorated electrical systems, significant structural degradation, and criticality and exposure risks. The project completely revised the D and D approach after a worker fell through an operating floor and was seriously injured. For protection from deteriorated building conditions, the project reduced the number of workers in the facility, limited their hours in the building, and installed nets and barriers to protect them from falls through weakened floors and from falling material. The new plan involved removing high-risk components, removing motors and compressors, and demolishing the building from the outside with heavy equipment with most of the piping and components inside the building during demolition. The team provided temporary electrical power; reconfigured the criticality alarm system; upgraded security; performed sampling and analysis to locate and characterize HEU deposits and Tc-99; and, to establish 'criticality incredible' conditions, conducted a nondestructive assay program and injected foam into equipment and piping as a contamination fixative. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radon Vapor Intrusion Screening Level Calculator - 17041

The U.S. Environmental Protection Agency has produced a web-based calculator for the assessment of cancer risk from radon in soil, soil gas, and pore water seeping into above-ground buildings. Like the chemical vapor intrusion screening level (VISL) calculator, the radon VISL (RVISL) provides screening levels in subsurface soil and water that are protective of preliminary remediation goals (PRGs) for radon in air that are based on either cancer risk or Applicable or Relevant and Appropriate Requirements (ARARs). In addition to the screening levels calculated, the RVISL can also calculate the risk from radon concentrations in soil, water, and air. The exposure routes evaluated in the RVISL are inhalation and external exposure from submersion in radon. Two source term options are provided for the user: one without radioactive decay and one with decay. Sources continually generating radon (Rn-222 and Rn-220), such as below ground uranium, would best be modeled with the 'without decay' models. Radon is the second leading cause of lung cancer. Radon is released from the normal decay of uranium, thorium, and radium in rocks and soil. It is an invisible, odorless, tasteless gas that seeps up through the ground and diffuses into the air. In areas without adequate ventilation, such as underground mines, radon can accumulate to levels that substantially increase the risk of lung cancer. Radon can enter homes through cracks in floors, walls, or foundations, and collect indoors. It can also be released from building materials, or from water obtained from wells that contain radon. Radon levels can be higher in homes that are well insulated, tightly sealed, and/or built on soil rich in the elements uranium, thorium, and radium. Basement and first floors typically have the highest radon levels because of their closeness to the ground. The RVISL will also allow for the calculation of screening levels for thoron (Rn-220) and Rn-219. The RVISL will be useful in assessing the final cleanup goals for subsurface soils where direct contact is not assumed. These sites can be landfills, buried waste cells or naturally occurring. By calculating protective levels of radon in subsurface soils, the likelihood of exceeding CERCLA protective standards (either risk range or ARARs) can be reduced. (authors)

54 ENVIRONMENTAL SCIENCES↗

Remediation of 130 mSv/hr. Soil Contamination Under a Hot Cell - 17301

Department of Energy (DOE) contractor CH2M HILL Plateau Remediation Company (CH2M) is currently engineering a system to safely remove and dispose of highly contaminated soil underneath Building 324 located adjacent to the Columbia River on the Hanford Site in Washington State. Cleaning up the waste site will allow for the eventual demolition of the building, which is a top priority for DOE and CH2M due to the proximity of the Columbia River and City of Richland. Building 324 at Hanford was originally constructed in 1966 and was operated for a number of years serving various missions. One of the missions involved development of treatment processes for liquid high activity waste. As of result of one particular mission, liquid high activity waste was spilled in one of the building's hot cells (known as 'B' Cell) and the liquid leaked from a breach in a sump and through construction joints in the hot cell floor and into the soil. Sampling efforts using borehole technology revealed significant under-building contamination with dose rates measuring has high as 130 mSv/hr (13,000 R/hr.). The Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) between the Washington State, Department of Ecology (Ecology), the U.S. Environmental Protection Agency and the DOE has established a 2021 milestone for demolition and removal of the Building 324. Before building demolition can be undertaken, the highly contaminated soil must be removed from beneath the hot cell while the hot cell structure remains in place to provide shielding and containment during the soil remediation. CH2M will fabricate and install remotely operated equipment that will remove debris and grout in the cell, the floor of the hot cell, and the contaminated soil beneath the hot cell and package that soil for disposal. To ensure that the structure remains intact and does not shift during soil removal, support for the building structure must also be constructed as a prerequisite for the planned work. CH2M will use a full-scale mock-up of the Building 324 B Cell and airlock area to assist in the testing of the remotely operated equipment and the training of the soil removal team in a contamination-free environment to ensure efficient and safe performance of the challenging work of the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vapor Intrusion Mitigation Beneath an Occupied Industrial Building at the Young - Rainey Science, Technology, and Research Center Largo, Florida - 17463

Groundwater contamination, consisting of chlorinated solvents, was identified in the southeastern portion of the Pinellas Site in Largo, Florida. The contamination is beneath Building 100, an 11-acre building that housed manufacturing facilities during US Department of Energy (DOE) operations at the site. Because the building was constructed in phases over a period of decades, it is comprised of approximately 20 different buildings, each with a separate foundation, all of which are now connected under a single roof. Based on the results of a pilot test that indicated the presence of volatile organic compounds beneath the floor slab and, in the absence of state regulations or guidance, DOE elected to proactively address the potential for release of these compounds into the facility by designing and installing a vapor intrusion (VI) mitigation system. To ventilate vapors from beneath the building, piping was installed from beneath the concrete floor slab through the roof, and negative pressure was created using electric blowers. The system design was complicated by foundation walls supporting each of the various sections of Building 100 and by special requirements due to the sensitive nature of the tenant's manufacturing activities and the heightened need for security. This paper addresses significant aspects of the design and construction of a VI mitigation system beneath a large, occupied industrial production facility, including technical, logistical, and environmental challenges; community relations; and regulatory relations. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a contaminated facility and associated soils in support of D and D and subsequent soil remediation - 15292

Before starting any D and D field work at a United States Department of Energy (DOE) facility such as the Savannah River Site (SRS), it is recommended that a complete review and understanding of the full nature and extent of any contamination located in or previously associated with that facility is known. An integral aspect of this review and research entails a complete characterization of that facility, including, but not limited to, Toxic Substances Control Act (TSCA) limits for Polychlorinated Biphenyl (PCB), radiological, Resource Conservation and Recovery Act of 1976 (RCRA) and other hazardous chemicals, etc. A thorough characterization of a facility and its underlying soils supports: - establishment of safe working conditions to protect human health and environment - Deactivation and Decommissioning (D and D) methodology - cost estimates to support future budget planning for D and D and soil cleanup A prime example of this is documented in the characterization of the 690-N, Process Heat Exchanger Repair Facility that had a history of PCB and radioactive contamination. Characterization of 690-N included the sampling and analysis of concrete and underlying soils for radiological, PCB and hazardous contaminants. In addition, a sump, the walls of the facility, expansion joint material and the metal base of a drill press were characterized. Results of this comprehensive characterization of the 690-N Building are provided in a detailed report. Analytical results indicate minimal radiological, PCB, or RCRA hazardous contamination is present in the concrete floor slab (industrial exposure levels) and on the steel hut walls. Soils below the concrete floor slab show only trace amounts of radiological contamination and are well below TSCA and RCRA limits. Subsequent decommissioning/demolition activities can be performed safely without harming people or the environment, and cost estimates to perform building demolition can be developed for future budget planning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Erosion and corrosion analysis of waste transfer components in the POR104 valve box at Hanford - 15715

At the United States Department of Energy Hanford Site in Richland, Washington, waste is being transferred to storage tanks in preparation for treatment at the Waste Treatment and Immobilization Plant. Regulatory committees have concerns regarding the structural integrity of the waste transfer components being used. Washington River Protection Solutions (WRPS) has employed a Fitness-for-Service program, which is a multi-disciplinary engineering approach that is used to determine if equipment is fit to remain in operation for a specified projected period. An approach to monitor aging equipment is to take thickness measurements of components when feasible, to evaluate if there is any appreciable degradation in the integrity of the components. The thickness measurements can be used to determine if erosion or corrosion is occurring and predict the remaining lifespan of the components. These predictions can also be used to develop design modifications for new piping and pipe jumpers. Analysis of thickness measurements have been conducted on four floor nozzles in the POR104 valve box located in the C-Tank Farm at Hanford. The data for the floor nozzles of the valve box does not show signs of wear, but there are variations in thicknesses which are likely due to manufacturing processes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Savannah River Site Defense Waste Processing Facility Melt Cell Remote Cleanup - 18037

This paper documents experiences at Savannah River Site (SRS) related to both the modification and use of a commercial remote vehicle to remove years of process-related litter (glass and various objects) from a hot cell floor during a production outage. The outage was necessary to replace a Department of Energy Environmental Management (DOE-EM) remotely-operated glass melter that had vitrified waste for 14 years at the Defense Waste Processing Facility. Both chunks of waste glass and numerous items littered the floor of the cell all associated with the long production run. The presence of litter become problematic as it could eventually impede movement or placement of items necessary to continue facility operation. The cleanup also reduces radiation rates within the hot cell which is beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation protection at the SwissFEL free electron laser facility: Beam stopping devices - Paper 53

The new large-scale facility SwissFEL (Swiss Free Electron Laser) is currently under construction at the Paul Scherrer Institute. The facility is situated underground in the ground floor of a two-floor building, partly integrated in a recreation area. This results into new challenges for radiation protection related tasks, in particular for the design of beam-stopping devices. The design of each beam-stopping device has to ensure that the dose rate during operation outside of the accelerator vault is in compliance with the legal limits defined by the Swiss radiation protection ordinance. In this work, the final design of the dumps is presented with the description of the underlying operational and legal constraints. Reuse of activated material as concrete, lead and steel is included in the main design criteria. As a result, four beam stopping devices consist for more than 90 % of material already available at PSI. In addition, routine operation and maintenance scenarios are discussed from a radiation protection point of view. (authors)

42 ENGINEERING↗

Reactivity effects at the Mayak production association, January 2, 1958 criticality accident using serpent 2 and openFOAM - 14444

The process nuclear criticality accident that occurred at the Mayak Production Association (Chelyabinsk-40) on January 2, 1958 involving a vessel of uranyl nitrate solution claimed the lives of three workers and left a fourth worker with continuing health problems. There are a myriad of uncertain parameters involved with this accident: What was the molarity of the solution? How much solution was in the vessel at the time of the accident? In what position was the vessel and the solution when it went critical? How important was the impact of reflection due to the workers and/or the floor? These uncertain parameters have made this accident particularly difficult to analyze in the past. This work aims to lower the uncertainty on some of these parameters. A most-probable solution composition is determined by comparing literature on the physical properties of uranyl nitrate solutions to those presented in LA-13638 [1], which describes the accident in question. Using this most-probable solution, the main contributions to the reactivity of the system and hence the eventual accident, are identified through Serpent 2 and OpenFOAM analyses. Serpent 2, a Monte Carlo software tool, is used to perform calculations of the reactivity effects of lowering the vessel toward the floor and the reactivity added by the close proximity of workers. OpenFOAM, a C++ partial differential equation solver toolkit, is used to simulate the fluid inside the vessel as the vessel is tipped. This is done by treating the solution and air inside the vessel as two incompressible, isothermal, and immiscible fluids using a volume of fluid (VoF) approach. The goal of this approach is simply to track the interface between the two fluids, and hence give an accurate description of the geometrical structure of the solution as the vessel is tipped. These two unique tools are then coupled to provide a time-dependent flow simulation to study the effect that the changing geometrical structure had on the criticality of the system, which is novel to the criticality safety field. This work provides a more accurate picture of the accident going forward. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method of installing a hybrid foundation for offshore wind turbines

A method of installing a hybrid foundation for an offshore wind turbine, the method includes providing a monopile, friction wheel, and suction bucket; installing the friction wheel and suction bucket in the sea floor; and inserting the monopile through the opening into the sea floor.

Zeng, Xiangwu↗

ECAR-8823 Rev 0 Structural Evaluation of the MARVEL Support Frame in Dry Critical Configuration

The purpose of this ECAR is to structurally evaluate the MARVEL reactor support frame during the dry critical (DryCrit) start-up testing. The ECAR includes evaluation of the DryCrit configuration for tip-over of the frame during a seismic event, floor loading of the frame on the MFC-720 (TREAT) operating floor, stress analysis of the adapter ring, and stress analysis of the frame itself for gravity and seismic loads.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

The Indian Ocean, its supra-subduction history, and implications for ophiolites

We report Ophiolite complexes represent fragments of ocean crust and mantle formed at spreading centers and emplaced on land. The setting of their origin, whether at mid-ocean ridges, back-arc basins, or forearc basins has been debated. Geochemical classification of many ophiolite extrusive rocks reflect an approach interpreting their tectonic environment as the same as rocks with similar compositions formed in various modern oceanic settings. This approach has pointed to the formation of many ophiolitic extrusive rocks in a supra-subduction zone (SSZ) environment. Paradoxically, structural and stratigraphic evidence suggests that many apparent SSZ-produced ophiolite complexes are more consistent with mid-ocean ridge settings. Compositions of lavas in the southeastern Indian Ocean resemble those of modern SSZ environments and SSZ ophiolites, although Indian Ocean lavas clearly formed in a mid-ocean ridge setting. These facts suggest that an interpretation of the tectonic environment of ophiolite formation based solely on their geochemistry may be unwarranted. New seismic images revealing extensive Mesozoic subduction zones beneath the southern Indian Ocean provide one mechanism to explain this apparent paradox. Cenozoic mid-ocean-ridge–derived ocean floor throughout the southern Indian Ocean apparently formed above former sites of subduction. Compositional remnants of previously subducted mantle in the upper mantle were involved in generation of mid-ocean ridge lavas. The concept of historical contingency may help resolve the ambiguity on understanding the environment of origin of ophiolites. Many ophiolites with “SSZ” compositions may have formed in a mid-ocean ridge setting such as the southeastern Indian Ocean.

58 GEOSCIENCES↗

Conference Discussion of the Nuclear Force

Discussion of the nuclear force, lead by a round table consisting of T. Cohen, E. Epelbaum, R. Machleidt, and F. Gross (chair). After an invited talk by Machleidt, published elsewhere in these proceedings, brief remarks are made by Epelbaum, Cohen, and Gross, followed by discussion from the floor moderated by the chair. The chair asked the round table and the participants to focus on the following issues: (1)What does each approach (chiral effective field theory, large Nc, and relativistic phenomenology) contribute to our knowledge of the nuclear force? Do we need them all? Is any one transcendent? (2) How important for applications (few body, nuclear structure, EMC effect, for example) are precise fits to the NN data below 350 MeV? How precise do these fits have to be? (3) Can we learn anything about nonperturbative QCD from these studies of the nuclear force? The discussion presented here is based on a video recording made at the conference and transcribed afterward.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of the relationship between remotely sensed anthropogenic heat discharge and building energy use

This paper examined the relationship between remotely sensed anthropogenic heat discharge and energy use from residential and commercial buildings across multiple scales in the city of Indianapolis, Indiana, USA. Anthropogenic heat discharge was estimated based on a remote sensing-based surface energy balance model, which was parameterized using land cover, land surface temperature, albedo, and meteorological data. Building energy use was estimated using a GIS-based building energy simulation model in conjunction with Department of Energy/ Energy Information Administration survey data, Assessor's parcel data, GIS floor areas data, and remote sensing-derived building height data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

Very low temperature radiant heating/cooling indoor end system for efficient use of renewable energies

Solar or solar-assisted space heating systems are becoming more and more popular. The solar energy utilization efficiency is high when the collector is coupled with indoor radiant heating suppliers, since in principle, lower supply temperature means lower demand temperature and then the system heat loss is less. A new type radiant end system is put forward for even lower supply temperature compared to the conventional radiant floor heating systems. A three dimensional model was established to investigate its energy supply capacities. Simulation results show that 50 W per meter length tube can be achieved with the medium temperature of 30 C for heating and 15 C for cooling. The predicted results agree well with the actual data from a demonstration building. Furthermore, it is demonstrated that a supply temperature of 22 C in winter and of 17 C in summer already met the indoor requirements. The new end system has good prospects for effective use of local renewable resources. (author)

14 SOLAR ENERGY↗