Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Development of a Rotary Micro-filter for Radioactive Waste Applications

The processing rates of Savannah River Site (SRS) high-level waste decontamination processes are limited by the flow rate of the solid-liquid separation. The baseline process, using a 0.1 micron cross-flow filter, produces {approx}1.36 x 10{sup -5} m/s ({approx}0.02 gpm/ft{sup 2}) of filtrate under expected operating conditions. Savannah River National Laboratory (SRNL) demonstrated significantly higher filter flux for actual waste samples using a small-scale rotary filter. With funding from the U. S. Department of Energy Office of Cleanup Technology, SRNL personnel are evaluating and developing the rotary micro-filter for radioactive service at SRS. The authors improved the design for the disks and filter unit to make them suitable for high-level radioactive service. They procured two units using the new design, tested them with simulated SRS wastes, and evaluated the operation of the units. Work to date provides the following conclusions and program status. - The authors modified the design of the filter disks to remove epoxy and Ryton{sup R}. The new design includes welding both stainless steel and ceramic coated stainless steel filter media to a stainless steel support plate. The welded disks were tested in the full-scale unit. They showed good reliability and met filtrate quality requirements. - The authors modified the design of the unit, making installation and removal easier. The new design uses a modular, one-piece filter stack that is removed simply by disassembly of a flange on the upper (inlet) side of the filter housing. All seals and rotary unions are contained within the removable stack. - While it is extremely difficult to predict the life of the seal, the vendor representative indicates a minimum of one year in present service conditions is reasonable. Changing the seal face material from silicon-carbide to a graphite-impregnated silicon-carbide is expected to double the life of the seal. Replacement of the current seal with an air seal could increase the lifetime to 5 years and is undergoing testing in the current work. - The bottom bushing showed wear due to a misalignment during the manufacture of the filter tank. Replacing the graphite bushing with a more wear resistant material such as a carbide material will increase the lifetime of the bushing. This replacement requires a more wear resistant part or coating to prevent excessive wear of the shaft. The authors are currently conducting testing with the more wear resistant bushing. - The project team plans to use the rotary micro-filter as a filter in advance of an ion exchange process under development for potential deployment in SRS waste tank risers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Westinghouse Small Modular Reactor nuclear steam supply system design

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the first in a series of four papers which describe the design and functionality of the Westinghouse SMR. Also described in this series are the key drivers influencing the design of the Westinghouse SMR and the unique passive safety features of the Westinghouse SMR. Several critical motivators contributed to the development and integration of the Westinghouse SMR design. These design driving motivators dictated the final configuration of the Westinghouse SMR to varying degrees, depending on the specific features under consideration. These design drivers include safety, economics, AP1000{sup R} reactor expertise and experience, research and development requirements, functionality of systems and components, size of the systems and vessels, simplicity of design, and licensing requirements. The Westinghouse SMR NSSS consists of an integral reactor vessel within a compact containment vessel. The core is located in the bottom of the reactor vessel and is composed of 89 modified Westinghouse 17x17 Robust Fuel Assemblies (RFA). These modified fuel assemblies have an active core length of only 2.4 m (8 ft) long, and the entirety of the core is encompassed by a radial reflector. The Westinghouse SMR core operates on a 24 month fuel cycle. The reactor vessel is approximately 24.4 m (80 ft) long and 3.7 m (12 ft) in diameter in order to facilitate standard rail shipping to the site. The reactor vessel houses hot and cold leg channels to facilitate coolant flow, control rod drive mechanisms (CRDM), instrumentation and cabling, an intermediate flange to separate flow and instrumentation and facilitate simpler refueling, a pressurizer, a straight tube, recirculating steam generator, and eight reactor coolant pumps (RCP). The containment vessel is 27.1 m (89 ft) long and 9.8 m (32 ft) in diameter, and is designed to withstand pressures up to 1.7 MPa (250 psi). It is completely submerged in a pool of water serving as a heat sink and radiation shield. Housed within the containment are four combined core makeup tanks (CMT)/passive residual heat removal (PRHR) heat exchangers, two in-containment pools (ICP), two ICP tanks and four valves which function as the automatic depressurization system (ADS). The PRHR heat exchangers are thermally connected to two different ultimate heat sink (UHS) tanks which provide transient cooling capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transportation Package Seal Performance in Beyond Design Basis Thermal Exposures - 12472

The Nuclear Regulatory Commission (NRC) technical report, NUREG/CR-6886, 'Spent Fuel Transportation Package Response to the Baltimore Tunnel Fire Scenario', describes, in detail, an evaluation of the potential for a theoretical release of radioactive material from three different spent nuclear fuel (SNF) transportation packages, had they been exposed to the Baltimore tunnel fire that occurred in July of 2001. This evaluation determined the temperatures of various components of the packages, including the seals, using temperatures resulting from models of the Baltimore tunnel fire (as boundary conditions) and finite element models of the SNF packages. For two of the packages evaluated, the analyses indicated that the seals used would have exceeded their continuous-use rated service temperatures, meaning the release of radioactive material could not be ruled out with available information; However, for both of the packages evaluated, the analysis determined, by a bounding calculation, that the maximum potential release was well below the regulatory requirements for releases from a SNF package during the hypothetical accident condition (HAC) sequence of events in 10CFR Part 71. The NRC is investigating the performance of seals in SNF transportation packages exposed to fires that could exceed the HAC fire described in 10CFR Part 71, such as the Baltimore Tunnel Fire that occurred in 2001. The performance of package seals is important for determining the potential release of radioactive material from a package during a beyond-design-basis accident. The seals have lower temperature limits than other package components and are the containment barrier between the environment and the cask contents. The NRC Office of Nuclear Regulatory Research contracted the National Institute of Standards and Technology (NIST) to conduct small-scale thermal testing to obtain experimental data of the performance of seals during extreme temperature exposures. The experimental testing consisted of several small-scale pressure vessels fabricated with a modified ASME flange design and tested metallic and elastomeric seals, similar to those that might be used on an actual SNF transportation package. The vessels were heated in an electrical oven to temperatures as high as 800 deg. C (1472 deg. F), exceeding the rated temperatures of the seals in question. This paper will provide a summary of the testing conducted and present test results and conclusions. Fifteen metallic and elastomeric seal performance tests including two shakedowns were performed under beyond-design-basis thermal exposure conditions; twelve tests used metallic seals, two used ethylene-propylene seals, and one used a Teflon seal. Of the five repeat metallic-seal tests (Tests No.2, 3, 4, 8, and 9), leakage (decreasing vessel pressure) was observed in three of the tests (Tests No.3, 4, and 8) during the 9 h 800 deg. C (1472 deg. F) exposure. The times when the leakage occurred (the vessel pressure started to decrease) varied in the three tests performed. The two shakedown tests were conducted using a 30 min and 4 h exposure to 800 deg. C (1472 deg. F), respectively, and the seal appeared to hold vessel pressure. No leakage (unchanged vessel pressure within the pressure measurement uncertainty) was also observed in the two metallic seal tests that used 100 deg. C incremental heating from 427 deg. C (800 deg. F) to 627 deg. C (1160 deg. F) and from 427 deg. C (800 deg. F) to 727 deg. C (1340 deg. F), respectively, with at least 9 h exposure to each temperature increment. Three repeat metallic seal tests were also conducted at the seal maximum operating temperature of 427 deg. C (800 deg. F) for 9 h. The seal maintained vessel pressure within the measurement of the pressure transducer in all three tests. No leakage was observed in one ethylene-propylene seal tested at 300 deg. C (572 deg. F) for more than 20 hours; however, leakage was found in another ethylene-propylene seal tested at 450 deg. C (842 deg. F) for more than 20 hours (Test No.15). Leakage was also observed in the test (Test No.12) that used a TFE seal subject to 300 deg. C (572 deg. F) exposure. In these fifteen tests the temperature and time exposure variables were changed to map the performance of the metallic and polymeric seals at elevated temperatures beyond the rated operating temperatures. Both the metallic and polymeric seals were able to hold pressure even after leaks were detected and no catastrophic seal failure (i.e., a rapid release of pressure to atmospheric) occurred. Further testing on the polymeric seals would need to be performed to confirm the results in these tests.(authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material Investigation and Long-term Sealing Behavior of Helicoflex{sup R} Metal Seals used in Containers for Spent Nuclear Fuel - 17135

In Germany spent nuclear fuel is stored and transported in casks that possess bolted lid systems equipped with double jacket metal seals of Helicoflex{sup R} type in order to enable safe enclosure of the radioactive inventory. A dry interim storage period of 40 years was planned and the casks are licensed for that time span. However, due to political reasons and delayed disposal projects this time span is expected to increase significantly. It is therefore necessary to evaluate the long-term sealing behavior of the casks exceeding 40 years of operating time. In this paper, we discuss our approach to investigate the aging behavior of such metal seals, and to predict the long-term sealing behavior. Accelerated aging component tests with seals are performed at temperatures up to 150 deg. C to investigate the course of seal force, usable resilience and leakage rate. Even though these tests have already shown a significant decrease in seal force and usable resilience after aging times of less than 1 year, for most seals the leakage rate stayed better than the specified value. However, observation of the leakage rate has to be continued to determine the aging effect on the seal properties. As a main influence on the seal long-term behavior the increasing permanent deformation of the outer jacket has been recognized. It is made of aluminum or silver which means that the temperatures that are relevant for the aforementioned application in casks lead to creep deformation. For further investigation of seal behavior a comprehensive research program concerning the material characteristics and aging behavior of the individual seal components, with an emphasis on the outer jacket material, has been launched. The aim is to get a better understanding of the time and temperature dependent creep mechanisms and deformation. The examinations are separated into tests on seal segments and tests on standardized specimen. In order to be able to study the aging process, seal segments are compressed in flanges and stored at temperatures ranging from room temperature to 150 deg. C. After defined time intervals the segments are analyzed by using standardized tests including structure investigation and creep tests. The results are compared with the behavior of the specimen basic raw material. This is done to ensure comparability of the thin jacket material and additional sheet material used for standardized tests. Thus, the prediction of component changes after different aging times at different temperatures can be made. As a result forecasts on the long term seal behavior are intended. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NitroJet{sup R}'s Verification Test of Contaminated Water Storage Tank Decontamination in Fukushima Daiichi Nuclear Power Plant - 16489

After the Fukushima Daiichi nuclear disaster, much radioactively contaminated water has generated and has been stored into tanks in the site. Therefore, these contaminated water storage tanks (flange-type) are severely required to be decontaminated in order to be dismantled or to be reused to store cleaner water with less radioactive liquid waste and exposure of workers. Then, IHI Corporation (hereinafter, IHI) have verified that NitroJet{sup R} had capability to decontaminate these tanks under governmental grant (the Validation of technologies for contaminated water management project in the FY2013 Supplementary Budget). For this verification, IHI achieved acquiring DF (decontamination factor) by fabricating radioactive partial mock-ups with Rb-86. Moreover, IHI have demonstrated remote operation of decontamination work by using tank's partially full-scale mock up. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Activation in injection area of J-PARC 3-GeV rapid cycling synchrotron and its countermeasures - 25344

The 3-GeV rapid cycling synchrotron in Japan Proton Accelerator Research Complex aims to deliver a 1-MW proton beam to the neutron target and the main ring synchrotron. The existing beam power of the Rapid Cycling Synchrotron is up to 500 kW, and higher radiation doses are concentrated in the injection area. These activations are caused by the interaction between the foil and the beam. To reduce dose exposure to workers near the injection point, we study a new design of the injection scheme to secure sufficient space for radiation shielding and bellows. Experience has shown that eddy currents are generated in the metal flange near the magnet owing to the effect of the pulsed magnetic field used for injection, and the temperature exceeds 100 deg. C. The shield installed in the new injection system needs to have a layer structure, in which an insulator is inserted between iron shields to reduce the eddy current. From the results of the shielding calculation, even if 1 mm of polyethylene was inserted between two 9-mm-thick SUS 316 plates, which serve as shielding material, the shielding performance was reduced only about 5%, and we confirmed that it would function well. (authors)

43 PARTICLE ACCELERATORS↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial PIP-II Beam Current Monitor Fault Case Analyses & Beam Position Monitor Linearity Studies in CST Studio Suite

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time beam data while minimizing negative effects on beam quality. To ensure that one can be reasonably confident these sensors will behave as desired upon be-ing implemented within the beamline, simulations pre-dicting the performance of these sensors under beamline conditions can be used as a valuable tool for checking sensor functionality without a physical test bench. This paper details the design, testing, and results of two sensor models developed using CST Studio Suite soft-ware designed to mimic two sensors to be implemented within the PIP-III beamline: an elliptical, large-aperture beam position monitor (BPM) for which vertical & hori-zontal position signal linearity was analyzed, and an AC current transformer (ACCT) beam current monitor (BCM) used to search for potential fault cases within the BCM and beam pipe flange gaps. Special focus is given to the discovery of linearity variations within the BPM and the use of frequency domain techniques in the BCM fault case analyses.

Rouzky, A. R.↗

Passive and no-loss weather cap for protection of wind induced downdraft in sensitive exhaust system

The invention provides a device for removing heat from a building, the device having: a first tubular member defining a first cavity; a second tubular member defining a second cavity, whereby said second tubular member resides within the first cavity and is coaxial to the first tubular member; a double conic body coaxially residing in the first cavity and coaxially positioned with the second tubular member; and a flange dimensioned to extend over at least a portion of the periphery of the existing flue so as to aid in supporting the device on the flue.

Lisowski, Darius D.↗

Enhancing the ATR Primary Coolant System: A 3D Modeling Approach

The project consisted in system inspections to the ATR Primary Coolant System involving welds, fittings, motors, pumps, flanges, and heat exchangers to enhance Inservice Inspection program as required by DOE orders. NOTE: This article is to be published as "DOE & DOE Contractors Only" in the OPEXShare application, which means it will be available for viewing to DOE & DOE Contractor registered users only. This article can also be used by CAES for their training and safety meetings.

42 - ENGINEERING↗

ECAR-7547 Rev 0 MARVEL Intermediate Heat Exchanger Liner ASME Analysis

This ECAR analyzes the Secondary Coolant System liner, otherwise known as the Intermediate Heat Exchanger (IHX) Liner, as an ASME Section VIII, Division 1 pressure vessel. This analysis is only necessary in the event of a failure of the primary coolant boundary, in which case the IHX liner acts as a secondary confinement boundary to prevent primary coolant leakage. The liner main body or vessel is analyzed, as well as the liner flange ring.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

PERFORMANCE TESTING OF SPRING ENERGIZED C-RINGS FOR USE IN RADIOACTIVE MATERIAL PACKAGINGS CONTAINING TRITIUM

This paper describes the sealing performance testing and results of silver-plated inconel Spring Energized C-Rings used for tritium containment in radioactive shipping packagings. The test methodology used follows requirements of the American Society of Mechanical Engineers (ASME) summarized in ASME Pressure Vessel Code (B&PVC), Section V, Article 10, Appendix IX (Helium Mass Spectrometer Test - Hood Technique) and recommendations by the American National Standards Institute (ANSI) described in ANSI N14.5-1997. The tests parameters bound the predicted structural and thermal responses from conditions defined in the Code of Federal Regulations 10 CFR 71. The testing includes an evaluation of the effects of pressure, temperature, flange deflection, surface roughness, permeation, closure torque, torque sequencing and re-use on performance of metal C-Ring seals.

42 ENGINEERING↗

Nanograting-based compact VUV spectrometer and beam profiler for in-situ characterization of high-order harmonic generation light sources

A compact, versatile device for VUV beam characterization is presented. It combines the functionalities of a VUV spectrometer and a VUV beam profiler in one unit and is entirely supported by a standard DN200 CF flange. The spectrometer employs a silicon nitride transmission nanograting in combination with a micro-channel plate based imaging detector. This enables the simultaneous recording of wavelengths ranging from 10 nm to 80 nm with a resolution of 0.25 nm to 0.13 nm. Spatial beam profiles with diameters up to 10 mm are imaged with 0.1 mm resolution. The setup is equipped with an in-vacuum translation stage that allows for in situ switching between the spectrometer and beam profiler modes and for moving the setup out of the beam. The simple, robust design of the device is well suited for non-intrusive routine characterization of emerging laboratory- and accelerator-based VUV light sources. Operation of the device is demonstrated by characterizing the output of a femtosecond high-order harmonic generation light source.

42 ENGINEERING↗

Longitudinal Wakefield Study in SLAC Rotatable Collimator Design for the LHC Phase II Upgrade

SLAC proposed a rotatable collimator design for the LHC Phase II collimation upgrade. There are 20 facet faces on each cylindrical jaw surface and two jaws are rotatable in order to introduce a clean surface in case of a beam hitting a jaw during operation. When the beam crosses the collimator, it will excite broad-band and narrow-band modes. The longitudinal modes can contribute to beam energy loss and power dissipation on the vacuum chamber wall. In this paper, the parallel finite element eigensolver Omega3P is used to search for all the longitudinal trapped modes in the SLAC collimator design. The power dissipation generated by the beam in collimators with different vacuum chamber and RF contact designs is discussed. It is found that a wider RF foil connecting the jaw and the vacuum flange can reduce efficiently the beam heating caused by the longitudinal modes.

43 PARTICLE ACCELERATORS↗

CH Packaging Operations Manual

This procedure provides instructions forassembling the following CH packaging payload: Drum payload assembly Standard Waste Box (SWB) assembly Ten-Drum Overpack (TDOP)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CH Packaging Operations Manual

This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing SWB Payload Assembly; and 1.7, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CH Packaging Operations Manual

This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-Gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing Shielded Container Payload Assembly; 1.7, Preparing SWB Payload Assembly; and 1.8, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence, except as noted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CH Packaging Operations Manual (Rev. 10)

This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-Gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing Shielded Container Payload Assembly; 1.7, Preparing SWB Payload Assembly; and 1.8, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence, except as noted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗