Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Instrumentation for one-way satellite PTTI applications

A review of general principles and operational procedures illustrates how the typical passive user and omni receiving antenna can recover Precise Time and Time Interval (PTTI) information from a low altitude navigation satellite system for clock calibration and synchronization. Detailed discussions of concepts and theory of the receiver design are presented. The importance of RF correlation of the received and local PN encoded sequences is emphasized as a means of reducing delay uncertainties of the instrumentation to values compatible with nanosecond to submicrosecond PTTI objectives. Two receiver configurations were fabricated for use in satellite-to-laboratory experiments. In one receiver the delay-locked loop for PN signals synchronization used a dithered amplitude detection process while the second receiver used a complex sums phase detection method for measurement of delay error. The necessity for compensation of Doppler shift is discussed. Differences in theoretical signal acquisition and tracking performance of the design concepts are noted.

Osborne, A. E.↗

Integrated source and channel encoded digital communication system design study

The results of several studies Space Shuttle communication system are summarized. These tasks can be divided into the following categories: (1) phase multiplexing for two- and three-channel data transmission, (2) effects of phase noise on the performance of coherent communication links, (3) analysis of command system performance, (4) error correcting code tradeoffs, (5) signal detection and angular search procedure for the shuttle Ku-band communication system, and (6) false lock performance of Costas loop receivers.

Huth, G. K.↗

Minimum acquisition time detection

Two different methods of target detection when the return signal is contaminated with noise are discussed and compared. The first method uses Neyman-Pearson detection philosophy and selects the threshold level to give a desired false alarm probability. The maximum probability of false alarm is constrained by the target cross scan velocity component. The second method (minimum acquisition time detection), which is similar to the ideal observer, selects the threshold level to minimize the expected target acquisition time. The probabilities of false alarm and missed detection are selected so that the errors produced by these effects produce the minimum acquisition time. Three different scan techniques - linear, spiral and two-mode scan - are studied and compared.

Brock, H. I.↗

Ozone Trend Detectability

The detection of anthropogenic disturbances in the Earth's ozone layer was studied. Two topics were addressed: (1) the level at which a trend in total ozoning is detected by existing data sources; and (2) empirical evidence in the prediction of the depletion in total ozone. Error sources are identified. The predictability of climatological series, whether empirical models can be trusted, and how errors in the Dobson total ozone data impact trend detectability, are discussed.

Campbell, J. W.↗

Einstein Observatory solid state spectrometer observations of M87 and the Virgo cluster

X-ray observations of the galaxy M87 and of a region in the Virgo cluster displaced 7 arcmin from the center of M87 are reported. X-ray spectra were obtained at these two locations with the Solid State Spectrometer onboard the Einstein Observatory. Emission lines were observed in both locations, indicating the presence of heavy elements at abundances near solar. There is no strong abundance gradient, within the errors. A temperature gradient has been detected: T increases from about 1.4 keV at the position of M87 to about 3.35 keV 7 arcmin away. There is lower temperature thermal emission at the center of M87 with T about 0.6 keV, consistent with models for cooling flows in this cluster. A mass infall rate of nearly 20 solar masses/yr has been obtained. In addition to the thermal emission, a power-law component has been detected in the spectrum of M87, consistent with that observed by HEAO 1, indicating that this component probably originates in the galaxy itself. Comparison of the results with those of other observers and with theoretical models for this source indicates the presence of intracluster gas having density near 1/1000 per cu cm and temperature of about 30,000,000 K.

Lea, S. M.↗

Ultraviolet observations of the transient X-ray sources A0535 + 26 and A0620-00

Observations of A0535+26 (HDE 245770) by the ANS in September 1975 and March 1976 when it was at the X-ray low state are discussed. Also observed were 58 early-type stars lying within 10 deg of HDE 245770; these stars are used to derive a localized extinction curve. On the basis of the depth of the 2200 A interstellar absorption feature observed in the ANS flux distribution of HDE 245770 and the shape of the localized extinction curve, an E(B-V) = 0.72 is derived for HDE 245770. Observations were made of this system during its X-ray flare-up (October 1980) and quiescent (November 1981) states by the IUE. It is noted that the fine error sensor on board the IUE detected an increase in the optical brightness of HDE 245770 during the X-ray outburst. This greatly corroborates the identification of HDE 245770 as the optical counterpart of A0535+26. No significant change in the absorption-line profiles during the X-ray high and low periods is found, indicating that there was no significant increase in the stellar wind density when the X-ray flare-up occurred. The UV continuum level increased by less than 6 percent when it was near peak X-ray luminosity. The UV spectrum of HDE 245770 suggests that it is a B0 V or a B0 III star with its dereddened continuum slope slightly in favor of being a giant.

Wu, C.-C.↗

Bit Error Rate of Coherent M-ary PSK

The bit error rate (BER) for the coherent detection of M-ary PSK signals with Gray code bit mapping is considered. A closed-form expression for the exact BER of M-ary PSK is presented. Tight upper and lower bounds on BER are also obtained for M-ary PSK with larger M.

Lee, P. J.↗

Impact of random pointing and tracking errors on the design of coherent and incoherent optical intersatellite communication links

Given the rms transmitter pointing error and the desired probability of bit error (PBE), it can be shown that an optimal transmitter antenna gain exists which minimizes the required transmitter power. Given the rms local oscillator tracking error, an optimum receiver antenna gain can be found which optimizes the receiver performance. The impact of pointing and tracking errors on the design of direct-detection pulse-position modulation (PPM) and heterodyne noncoherent frequency-shift keying (NCFSK) systems are then analyzed in terms of constraints on the antenna size and the power penalty incurred. It is shown that in the limit of large spatial tracking errors, the advantage in receiver sensitivity for the heterodyne system is quickly offset by the smaller antenna gain and the higher power penalty due to tracking errors. In contrast, for systems with small spatial tracking errors, the heterodyne system is superior because of the higher receiver sensitivity.

Chen, Chien-Chung↗

Checking Automated-Welder Programs By Computer

Computer system detects and displays actual and potential errors in programs for computer-controlled electron-beam welder. Uses personal computer, separate from welding computer. Programmed specifically to highlight errors in welding program. Eliminates need for preweld full-power test run reducing checkout time to about half hour. Assures much higher quality, damage-free welding. Used to create and edit new programs for welder. Control computer thereby free for production. Useful for checking programs for such other computer-controlled equipment as inertia welders, robots, machine tools, and heat treaters.

Damicone, L. O.↗

COS-B gamma ray sources beyond the predicted diffuse emission

COS-B data were reanalyzed using for background subtraction the modeled galactic diffuse gamma-ray emission based on HI- and CO-line surveys and the gamma-ray data itself. A methodology was developed for this purpose with the following three features: automatic generation of source catalogs using correlation analysis, simulation of trials to derive significance thresholds for source detection, and bootstrap sampling to drive error boxes and confidence intervals for source parameters. The analysis shows that about half of the 2CG sources are explained by concentrations in the distribution of molecular hydrogen. Indication for a few weak new sources is also obtained.

Mayer-Hasselwander, H. A.↗

Combined trellis coding and feedforward processing for MSS applications

The idea of using a multiple (more than two) symbol observation interval to improve error probability performance is applied to differential detection of trellis coded MPSK over a mobile satellite (fading) channel. Results are obtained via computer simulation. It is shown that only a slight increase (e.g., one symbol) in the length of the observation interval will provide a significant improvement in bit error probability performance both in AWGN and fading environments.

Divsalar, D.↗

A luminous X-ray binary in M82

Optical CCD imaging at the position of a bright X-ray point source just off the visible disk of the nearby irregular galaxy M82 constrain it to be an X-ray binary with a 0.2-4 keV X-ray luminosity of not less than 9 x 10 exp 38 ergs/sec. Assuming that the X-ray emission is due to a single object, then by asumming an Eddington limit appropriate for pure electron scattering, this luminosity requires a minimum primary mass of not less than 15 solar masses; thus, this X-ray source is a black hole candidate. If the brightest optical object detected inside the X-ray error circle at B about 22.2 is the secondary to the X-ray emitter, it is most likely an early type star making this system the most luminous massive X-ray binary system known.

Stocke, John T.↗

The ParaScope parallel programming environment

The ParaScope parallel programming environment, developed to support scientific programming of shared-memory multiprocessors, includes a collection of tools that use global program analysis to help users develop and debug parallel programs. This paper focuses on ParaScope's compilation system, its parallel program editor, and its parallel debugging system. The compilation system extends the traditional single-procedure compiler by providing a mechanism for managing the compilation of complete programs. Thus, ParaScope can support both traditional single-procedure optimization and optimization across procedure boundaries. The ParaScope editor brings both compiler analysis and user expertise to bear on program parallelization. It assists the knowledgeable user by displaying and managing analysis and by providing a variety of interactive program transformations that are effective in exposing parallelism. The debugging system detects and reports timing-dependent errors, called data races, in execution of parallel programs. The system combines static analysis, program instrumentation, and run-time reporting to provide a mechanical system for isolating errors in parallel program executions. Finally, we describe a new project to extend ParaScope to support programming in FORTRAN D, a machine-independent parallel programming language intended for use with both distributed-memory and shared-memory parallel computers.

Cooper, Keith D.↗

Optical system storage design with diffractive optical elements

Optical data storage systems are gaining widespread acceptance due to their high areal density and the ability to remove the high capacity hard disk from the system. In magneto-optical read-write systems, a small rotation of the polarization state in the return signal from the MO media is the signal which must be sensed. A typical arrangement used for detecting these signals and correcting for errors in tracking and focusing on the disk is illustrated. The components required to achieve these functions are listed. The assembly and alignment of this complex system has a direct impact on cost, and also affects the size, weight, and corresponding data access rates. As a result, integrating these optical components and improving packaging techniques is an active area of research and development. Most designs of binary optic elements have been concerned with optimizing grating efficiency. However, rigorous coupled wave models for vector field diffraction from grating surfaces can be extended to determine the phase and polarization state of the diffracted field, and the design of polarization components. A typical grating geometry and the phase and polarization angles associated with the incident and diffracted fields are shown. In our current stage of work, we are examining system configurations which cascade several polarization functions on a single substrate. In this design, the beam returning from the MO disk illuminates a cascaded grating element which first couples light into the substrate, then introduces a quarter wave retardation, then a polarization rotation, and finally separates s- and p-polarized fields through a polarization beam splitter. The input coupler and polarization beam splitter are formed in volume gratings, and the two intermediate elements are zero-order elements.

Kostuk, Raymond K.↗

Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: 7 HIRS (High-resolution Infrared Sounder) and 4 AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging, In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models, Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

Garand, L.↗

Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: seven HIRS (High-resolution Infrared Sounder) and four AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor, and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging. In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models. Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

Garand, L.↗

Fluorescence Imaging of Rotational and Vibrational Temperature in a Shock Tunnel Nozzle Flow

Two-dimensional rotational and vibrational temperature measurements were made at the nozzle exit of a free-piston shock tunnel using planar laser-induced fluorescence. The Mach 7 flow consisted predominantly of nitrogen with a trace quantity of nitric oxide. Nitric oxide was employed as the probe species and was excited at 225 nm. Nonuniformities in the distribution of nitric oxide in the test gas were observed and were concluded to be due to contamination of the test gas by driver gas or cold test gas.The nozzle-exit rotational temperature was measured and is in reasonable agreement with computational modeling. Nonlinearities in the detection system were responsible for systematic errors in the measurements. The vibrational temperature was measured to be constant with distance from the nozzle exit, indicating it had frozen during the nozzle expansion.

Palma, Philip C.↗

Sptrace

Sptrace is a general-purpose space utilization tracing system that is conceptually similar to the commercial Purify product used to detect leaks and other memory usage errors. It is designed to monitor space utilization in any sort of heap, i.e., a region of data storage on some device (nominally memory; possibly shared and possibly persistent) with a flat address space. This software can trace usage of shared and/or non-volatile storage in addition to private RAM (random access memory). Sptrace is implemented as a set of C function calls that are invoked from within the software that is being examined. The function calls fall into two broad classes: (1) functions that are embedded within the heap management software [e.g., JPL's SDR (Simple Data Recorder) and PSM (Personal Space Management) systems] to enable heap usage analysis by populating a virtual time-sequenced log of usage activity, and (2) reporting functions that are embedded within the application program whose behavior is suspect. For ease of use, these functions may be wrapped privately inside public functions offered by the heap management software. Sptrace can be used for VxWorks or RTEMS realtime systems as easily as for Linux or OS/X systems.

Burleigh, Scott C.↗