Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “elastomer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Highly stretchable carbon nanotube transistors enabled by buckled ion gel gate dielectrics

Deformable field-effect transistors (FETs) are expected to facilitate new technologies like stretchable displays, conformal devices, and electronic skins. We previously demonstrated stretchable FETs based on buckled thin films of polyfluorene-wrapped semiconducting single-walled carbon nanotubes as the channel, buckled metal films as electrodes, and unbuckled flexible ion gel films as the dielectric. The FETs were stretchable up to 50% without appreciable degradation in performance before failure of the ion gel film. Here, we show that by buckling the ion gel, the integrity and performance of the nanotube FETs are extended to nearly 90% elongation, limited by the stretchability of the elastomer substrate. The FETs maintain an on/off ratio of >10{sup 4} and a field-effect mobility of 5 cm{sup 2} V{sup −1} s{sup −1} under elongation and demonstrate invariant performance over 1000 stretching cycles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Super-stretchable metallic interconnects on polymer with a linear strain of up to 100%

Metal interconnects in flexible and wearable devices are heterogeneous metal-polymer systems that are expected to sustain large deformation without failure. The principal strategy to make strain tolerant interconnect lines on flexible substrates has comprised of creating serpentine structures of metal films with either in-plane or out-of-plane waves, using porous substrates, or using highly ductile materials such as gold. The wavy and helical serpentine patterns preclude high-density packing of interconnect lines on devices, while ductile materials such as Au are cost prohibitive for real world applications. Ductile copper films can be stretched if bonded to the substrate, but show high level of cracking beyond few tens of % strain. In this paper, we demonstrate a material system consisting of Indium metal film over an elastomer (PDMS) with a discontinuous Cr layer such that the metal interconnect can be stretched to extremely high linear strain (up to 100%) without any visible cracks. Such linear strain in metal interconnects exceeds that reported in literature and is obtained without the use of any geometrical manipulations or porous substrates. Systematic experimentation is carried out to explain the mechanisms that allow the Indium film to sustain the high strain level without failure. The islands forming the discontinuous Cr layer are shown to move apart from each other during stretching without delamination, providing strong adhesion to the Indium film while accommodating the large strain in the system. The Indium film is shown to form surface wrinkles upon release from the large strain, confirming its strong adhesion to PDMS. A model is proposed based upon the observations that can explain the high level of stretch-ability of the Indium metal film over the PDMS substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hugoniot and Dynamic Strength in Polyurea

Polyurea is of interest for blast mitigation of structures, which requires a good understanding of the dynamic properties including the shock Hugoniot and dynamic spall and shear strength. In this study, reverse impact experiments were used to determine the shock Hugoniot, direct impact experiments were used to determine the spall strength, and lateral manganin gauge experiments were used to determine the dynamic shear strength. Reverse impact experiments revealed that the Hugoniot has a linear fit at low pressures and appears to be undergoing a reaction at higher pressures. The spall strength experiments in this study in combination with the literature data showed that the spall strength increases as a function of pressure, which is unusual in polymers and may be attributed to polyurea transforming to a glassy phase. In the shear strength experiments, the shear stress was shown to increase with increasing longitudinal stress in polyurea, similar to estane, another elastomer.

36 MATERIALS SCIENCE↗

Tunable shear thickening, aging, and rejuvenation in suspensions of shape-memory-endowed liquid crystalline particles

The morphological features of particles, notably shape anisotropy, critically influence the rheological properties of dense suspensions, spanning both natural and engineered systems. This work explores the potential of using shape memory particles to dynamically regulate suspension fluid flow through controllable shape transformations. First, we synthesize shape-memory particles with programmable anisotropy from liquid crystal elastomers, such that the stiffness and shapes of the particles can be tuned by manipulating temperature. Our findings reveal that suspensions from such particles exhibit significant tunability in shear thickening behavior, transitioning from discontinuous shear thickening to a Newtonian-like response within a narrow temperature range of 60 ° C. This capability to modulate rheological responses in situ presents an approach for addressing processing challenges in many applications where control over flow behavior is paramount. Furthermore, we also show that suspensions composed of these anisotropic particles can undergo physical aging, and evolve into a glassy state. This state can be escaped upon activation of the shape memory effect. This reversibility underscores the potential for using such materials to engineer systems that can enter or come out of kinetic arrest by leveraging internal mechanical responses to external stimuli. The insights gained here not only broaden our understanding of the interplay between particle geometry and suspension dynamics but also pave the way for leveraging ensembles of stimuli-responsive objects to precisely control collective behaviors in many-body systems.

Science & Technology - Other Topics↗

Mortality, Transmitter Retention, Growth, and Wound Healing in Juvenile Salmon Injected with Micro Acoustic Transmitters

A cylindrical acoustic transmitter (AT; 0.2 g) has been developed for injection into the peritoneum of fish. Laboratory studies can provide tagging guidelines to minimize the effect of implantation techniques and transmitter burden (relative weight of the transmitter to the weight of the fish) in fish before a transmitter is used in field studies. The goal of this study was to examine response variables (mortality, transmitter expulsion, growth, wound area) of juvenile Chinook Salmon (Oncorhynchus tschawytscha; 65–104 mm fork length [FL]) injected with an AT along a wide range of sizes that could lead to a guideline for minimizing tagging effects. The overarching goal was to determine a minimum size threshold for fish that can be injected, while minimizing adverse transmitter effects. Juveniles (n = 700) were separated into four treatments: (1) acoustic transmitter injection (AT), (2) AT and a passive integrated transponder tag injection (AT+PIT), (3) visual implant elastomer injection (Marked control), and (4) unmarked (Unmarked control). Fish were evaluated weekly for four weeks, and again at the end of the study (60 d post-tagging). Fish injected with an AT or an AT+PIT experienced greater mortality than Marked controls. By 60 d post-tagging, transmitter expulsion was 44% for AT fish and 20% for AT+PIT fish. Fish injected with an AT or an AT+PIT grew (FL and weight gain) significantly less than Marked controls, and no minimum size thresholds were detected. Finally, initial size (FL) significantly affected wound area in AT and AT+PIT fish. A size threshold was only identified on Day 7 (85.1 mm) for AT+PIT fish, indicating that wound areas in fish < 85.1 mm were larger than wound areas of fish > 85.1 mm. This research suggests that injecting juveniles with an AT or an AT+PIT had a greater effect on smaller fish than larger fish.

Chinook↗

Investigation of the role of hydrophilic chain length in amphiphilic perfluoropolyether/poly(ethylene glycol) networks: towards high-performance antifouling coatings

The facile preparation of amphiphilic network coatings having a hydrophobic dimethacryloxy-functionalized perfluoropolyether (PFPE-DMA; M{sub w} = 1500 g mol{sup -1}) crosslinked with hydrophilic monomethacryloxy functionalized poly(ethylene glycol) macromonomers (PEG-MA; M{sub w} = 300, 475, 1100 g mol{sup -1}), intended as non-toxic high-performance marine coatings exhibiting antifouling characteristics is demonstrated. The PFPE-DMA was found to be miscible with the PEG-MA. Photo-cured blends of these materials containing 10 wt% of PEG-MA oligomers did not swell significantly in water. PFPE-DMA crosslinked with the highest molecular weight PEG oligomer (ie PEG1100) deterred settlement (attachment) of algal cells and cypris larvae of barnacles compared to a PFPE control coating. Dynamic mechanical analysis of these networks revealed a flexible material. Preferential segregation of the PEG segments at the polymer/air interface resulted in enhanced antifouling performance. The cured amphiphilic PFPE/PEG films showed decreased advancing and receding contact angles with increasing PEG chain length. In particular, the PFPE/PEG1100 network had a much lower advancing contact angle than static contact angle, suggesting that the PEG1100 segments diffuse to the polymer/water interface quickly. The preferential interfacial aggregation of the larger PEG segments enables the coating surface to have a substantially enhanced resistance to settlement of spores of the green seaweed Ulva, cells of the diatom Navicula and cypris larvae of the barnacle Balanus amphitrite as well as low adhesion of sporelings (young plants) of Ulva, adhesion being lower than to a polydimethyl elastomer, Silastic T2.

36 MATERIALS SCIENCE↗

Tritium Effects on Aromatic Carbon–Loaded Polymers

By incorporating carbon nanotubes (CNTs) and graphene nanomaterials with aromatic sp2 carbon structures, we have specifically tuned filled ethylene propylene diene monomer elastomer (EPDM) seal and gasket composite materials for radiation resistance. Our results show that CNTs and graphene have an increased ability to stabilize the EPDM matrix compared to standard carbon black (CB) as a radiation-resistant filler. Here, graphene outperforms both CNT and CB fillers when considering surface damage under conditions where beta exposure is an issue. Both graphene and CNT fillers offer significantly reduced changes in glass transition temperature under prolonged exposure to tritium compared to CB-filled standards, with a 2.5-fold and almost 5-fold reduction, respectively. Thus, CNT- and graphene-filled O-ring materials could be designed that would maintain acceptable seals significantly longer than currently used composites.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cyclic olefin homopolymer-based microfluidics for protein crystallization and in situ X-ray diffraction

A cyclic olefin homopolymer-based microfluidics system has been established for protein crystallization and in situ X-ray diffraction. Microfluidics is a promising technology for the rapid identification of protein crystallization conditions. However, most of the existing systems utilize silicone elastomers as the chip material which, despite its many benefits, is highly permeable to water vapour. This limits the time available for protein crystallization to less than a week. Here, the use of a cyclic olefin homopolymer-based microfluidics system for protein crystallization and in situ X-ray diffraction is described. Liquid handling in this system is performed in 2 mm thin transparent cards which contain 500 chambers, each with a volume of 320 nl. Microbatch, vapour-diffusion and free-interface diffusion protocols for protein crystallization were implemented and crystals were obtained of a number of proteins, including chicken lysozyme, bovine trypsin, a human p53 protein containing both the DNA-binding and oligomerization domains bound to DNA and a functionally important domain of Arabidopsis Morpheus’ molecule 1 (MOM1). The latter two polypeptides have not been crystallized previously. For X-ray diffraction analysis, either the cards were opened to allow mounting of the crystals on loops or the crystals were exposed to X-rays in situ. For lysozyme, an entire X-ray diffraction data set at 1.5 Å resolution was collected without removing the crystal from the card. Thus, cyclic olefin homopolymer-based microfluidics systems have the potential to further automate protein crystallization and structural genomics efforts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Damp Heat Induced Degradation of Silicon Heterojunction Solar Cells With Cu-Plated Contacts

Damp heat exposure is one of the most stringent environments for testing the durability of solar cells in packaged modules. Damp heat stresses and induces a variety of degradation modes in solar cells and modules: for example, moisture-induced corrosion of electrodes and interconnections, deterioration of polymeric materials, and/or thermally activated diffusion processes. To screen for these and other potential degradation modes, we subject one-cell modules containing silicon heterojunction (SHJ) solar cells with Cu-plated contacts to extended damp heat tests at 85 °C/85% relative humidity. SHJ cells were laminated with two common encapsulants: ethylene vinyl acetate (EVA) and polyolefin elastomer (POE), and two constructions: glass-backsheet and glass-glass. We observe degradation in all components of solar cell maximum power (PMP): current, voltage, and fill factor, and find evidence of increased carrier recombination and nonideal diode behavior with increasing stress. For glass-backsheet constructions, EVA samples generally degrade more than POE by a factor of approximately 1.5x PMP, and the different encapsulants produce different degradation patterns. Similar trends are observed in glass-glass modules, but to a lesser degree. In a different experiment, we observe a decrease in effective minority carrier lifetime of nonmetallized SHJ precursors measured after damp heat. This implies that some degradation unrelated to the contacts is to be expected and confirms the observation of increasing recombination.

14 SOLAR ENERGY↗

Investigating the Crosslinking, Degradation, and Adhesion Behavior of Photovoltaic Encapsulants Under Thermal Accelerated Aging

Degradation of photovoltaic (PV) module encapsulant characteristics that lead to mechanical embrittlement and delamination remains a cause of failure in solar installations. A multiscale reliability model connecting the encapsulant mechanical and fracture properties to the degraded molecular structure and interfacial bonding to adjacent solar cell and glass substrates was previously published. The model, developed primarily for poly(ethylene-co-vinyl acetate) acetate (EVA) encapsulants, remains to be experimentally validated. Determining the degradation and crosslinking kinetics of alternative encapsulants, such as polyolefin elastomer (POE) and EVA/POE/EVA composites (EPE), can generalize the model. In this work, we subject fully cured EVA, POE, and EPE encapsulants to accelerated thermal aging to determine how high temperatures impact reaction kinetics. An increase in gel content (crosslinking) and decrease in crystallinity of the encapsulants under hot-aerobic (90 degrees C, 22% RH) and hot-anaerobic (90 degrees C, sealed in N 2 air) aging were observed, even in the absence of UV and crosslinking initiators. Fourier transform infrared spectroscopy (FTIR)-attenuated total reflectance analysis showed insignificant encapsulant degradation, demonstrating the critical role of UV and moisture in accelerating degradation. Adhesion testing performed on coupon-level specimens (cell/encapsulant/glass laminates) showed decreases in adhesion energy, Gc , from 5000 h of hot-dry (90 degrees C, ~1% RH) and hot-humid (90 degrees C, 60% RH) aging. POE coupons demonstrated the best stability, followed by EPE then EVA. For EVA and POE, hot-humid aged coupons experienced a larger decrease in Gc due to enhanced hydrolytic degradation. Hot-dry aging condition demonstrated that thermal degradation of the interface could be significant even if the encapsulant experiences negligible degradation in the absence of UV and elevated humidity.

accelerated aging↗

Sequential Stress Identifies Processing Defects in Bifacial Photovoltaic Modules That Limit Durability

Here, we use sequential stress to investigate hurdles to bifacial photovoltaic (PV) module durability from lamination defects. We test mini-modules with glass/glass (G/G) and glass/transparent-backsheet (G/TB) constructions using either ethylene vinyl acetate or polyolefin elastomer (POE) based encapsulants under a modified IEC 63209-2 sequential stress. This sequence includes multiple iterations of damp heat (DH200), full spectrum light exposure (A3), thermal cycling (TC50), and humidity/freeze (HF10). We compare indoor stress with outdoor exposure. Results show similar relative trends in degradation after a year outdoors compared to our first stress cycle. Subsequent stress cycles impart more severe damage than outdoor exposure for the short outdoor duration used here. Edge-pinch lamination defects in G/G mini-modules limit durability causing delamination and cell cracks. Conversely, we observe greater degradation in G/TB mini-modules compared to G/G in the later stages of the stress sequence when the backsheets are directly exposed to UV-containing light. Our results highlight: 1) the utility of sequential stress testing to uncover degradation modes in bifacial PV, 2) implications of using mini-modules for testing PV quality, and 3) the importance of lamination defects that must be avoided to ensure durability as the industry adopts G/G or G/TB packaging.

14 SOLAR ENERGY↗

Evaluation of the PID-s Susceptibility of Modules Encapsulated in Materials of Varying Resistivity

A common mechanism of potential-induced degradation is by shunting (PID-s) in PV modules, usually associated with the transport of sodium ions (Na+) through the encapsulant and penetrating the front junction of solar cells under voltage stress. Encapsulants with high volume resistivity have been suggested as a potentially cost-effective solution to this degradation mechanism. In this work, we examine three polyolefin elastomer (POE) encapsulants with volume resistivity varying over two orders of magnitude (ranging from 9 x 10^13 to 1 x 10^16 ..omega.. cm) that show equivalent and complete resistance to PID at the damp heat stress test level of 85 degrees C and 85% relative humidity and -1000 V system voltage stress. Performance is compared with a PID-susceptible ethylene vinyl acetate (EVA) encapsulant with resistivity 1 x 10^13 ..omega.. cm. The independence of PID susceptibility with respect to the resistivity of the polyolefin is attributed to the impermeability of POEs to Na + ions. Specific ions (i.e. Na + ), rather than charge-carrying species in general, are responsible for this degradation mechanism.

14 SOLAR ENERGY↗

Mechanistic Insights to Degradation of PERC Minimodules with Differentiated Packaging Materials & Module Architectures

In this paper, we study the degradation behavior of glass-backsheet (GB) and double glass (DG) multicrystalline sil- icon monofacial PERC minimodules, fabricated using polyolefin elastomer (POE) and ethylene vinyl acetate (EVA) encapsulants, undergoing exposures of modified damp-heat (80 °C / 85% RH), with and without full spectrum light. The completed exposure time, at this time, is 1512 hours with each step of 504 hours. Step- wise measurements are conducted throughout exposures including current-voltage (I-V ) curves, Suns-V oc , electroluminescence (EL) images, and four-point proof loading with EL for tracking changes in mechanical properties in encapsulants by cell fracture probability. The results show that GB minimodules of both encapsulants, compared to DG minimodules, experience more changes in features of I-V and Suns-V oc measurements. There is no development of PV cell cracking during proof loading as seen from EL images and the load versus load line displacement plots currently.

14 SOLAR ENERGY↗

Calibrating constitutive models with full‐field data via physics informed neural networks

Abstract The calibration of solid constitutive models with full‐field experimental data is a long‐standing challenge, especially in materials that undergo large deformations. In this paper, we propose a physics‐informed deep‐learning framework for the discovery of hyperelastic constitutive model parameterizations given full‐field surface displacement data and global force‐displacement data. Contrary to the majority of recent literature in this field, we work with the weak form of the governing equations rather than the strong form to impose physical constraints upon the neural network predictions. The approach presented in this paper is computationally efficient, suitable for irregular geometric domains, and readily ingests displacement data without the need for interpolation onto a computational grid. A selection of canonical hyperelastic material models suitable for different material classes is considered including the Neo–Hookean, Gent, and Blatz–Ko constitutive models as exemplars for general non‐linear elastic behaviour, elastomer behaviour with finite strain lock‐up, and compressible foam behaviour, respectively. We demonstrate that physics informed machine learning is an enabling technology and may shift the paradigm of how full‐field experimental data are utilized to calibrate constitutive models under finite deformations.

Hamel, Craig M.↗

Independence of Environmental and Mechanical Damages on Silicone Adhesive Stored in a Thermo-Oxidative Environment

Abstract Elastomeric polymer materials hold a special place in today’s industrial sectors with respect to structural application needs. Low quality materials are detrimental to industries like aerospace, and automotive engineering. Assessment of the durability of elastomers for structural applications has been of much interest among the literary circles for decades and new materials keep outperforming the existing ones. Polymeric adhesives are one of the most abundantly used materials in these industries. All polymeric materials get damaged when in contact with aggressive environments in presence of high temperature and oxygen. Commonly referred to as thermo-oxidation, this environment exposes the material to heat and oxidation reactions in presence of oxygen. Resultantly, during service life, the damage to the polymer matrix is primarily caused by two factors: mechanical damage and environmental aging. Environmental aging is an irreversible phenomenon caused by changes in the molecular structure while mechanical damage maintains the shape of the polymer matrix, and the deterioration is mostly due to polymer chain mobility. Environmental aging can be caused by a single environmental agent or by a synergized impact of several environmental elements. Increasing temperature is found to be proportional to decreasing tensile strength and toughness of material. The rate and extent of degradation can be accessed by scrutinizing the changes in constitutive behavior of material through mechanical and chemical properties. Accelerated thermal aging is among the most common modes of process related degradation, leading generally to chain scission, and crosslinking phenomena and reduced resistance to fracture stress, and strain. In this experimental study, our goal is to separate the environmental degradation from mechanical damage. A silicone-based adhesive was aged in thermo-oxidative at (0%RH) aging environment. The damage and decay mechanisms have been used to draw a distinction between environmental degradation and mechanical damage. Material characterization included uniaxial tensile test (failure and cyclic) and scanning electron microscopy (SEM) tests on as-received and aged samples. Aging was conducted at three different temperatures (60°C, 80°C and 95°C) and six different exposure durations (1, 3, 10, 30, 90 and 200 days). This work confirms that environmental damage is superposed on top of the mechanical damage, and thus, they are separable. The total mechanical and environmental damage is a synergized effect of all exposure conditions and parameters involved i.e., aging time, temperature, and oxygen. The chemistry and mechanics of the polymer degradation were found to be in good agreement with each other.

Alazhary, Sharif↗

Evaluation of Common Thermoplastic Polymers in High-Pressure Cycling Hydrogen Under Ambient and Cold Environments as Applicable to the Hydrogen Infrastructure

Thermoplastic polymers are required to perform unfailingly under stringent conditions of changing pressures (35 MPa to 70 MPa) and temperatures (-40°C to +85°C) in storage and fueling operations. Although diffusivity in glassy polymers appear to be an order of magnitude lower than elastomers, polymer microstructural attributes such as degree of crystallinity and presence of polar and non-polar groups on the main chain with and without branching can play a substantial role in influencing their behaviors in hydrogen environments. In the work described here, the effect of high-pressure hydrogen cycling on PEEK, PTFE, PA11, HDPE, POM (and different commercial grades of these polymers) under ambient and cold (-40°C) conditions is addressed. Ex-situ characterization for polymer changes included density measurements for impact of hydrogen retention, hardness changes using nanoindentation, storage modulus and glass transition changes using dynamic mechanical and thermal analysis (DMTA), degree of crystallization with Differential Scanning Calorimetry (DSC) and tensile testing following ASTM D412. In other evaluations, solid-state nuclear magnetic resonance (NMR), attenuated total reflectance Fourier transform infra-red spectroscopy (ATRFTIR), X-ray diffraction (XRD), and X-ray CT results are presented. The overall impact of these evaluations is to establish a technical basis for the behaviors of common thermoplastics in cycling hydrogen environments under ambient and cold temperatures while establishing the relationship between polymer structure-based properties and hydrogen transport effects.

Menon, Nalini C.↗

TH-C-17A-07: Visualizing and Quantifying Radiation Therapy in Real-Time Using a Novel Beam Imaging Technique

Purpose: Radiation therapy uses invisible high energy X-rays to treat an invisible tumor. Proper positioning of the treatment beam relative to the patient's anatomy during dose delivery is critically important to the success of treatment. We develop and characterize a novel radiation therapy beam visualization technique for real-time monitoring of patient treatment. Methods: Custom made flexible scintillator sheets were fabricated from gadolinium oxysulfide (GOS) particles that had been doped with terbium within a silicone elastomer matrix. Sheets of several thicknesses ranging from 0.3 to 1mm were prepared and tested. Sheets were exposed to megavoltage X-ray and electron beams from a Varian linac and the resulting optical signal was collected by multiple CMOS cameras placed in the treatment room. Real-time images were collected for different beam energies and dose rates. Signal intensity and SNR were calculated by processing the acquired images. Results: All signals were detectable in the presence of full room lighting and at an integration time of 45ms. Average signal intensity and SNR increased with both sheet thickness and dose rate and decreased with beam energy and incident light. For a given sheet thickness and beam energy the correlation between dose rate and signal intensity was highly linear. Increased sheet thickness or dose rate results in a linear increase in the detected signal. All results are consistent with analytical approximations. Conclusion: The technique offers a means of accurately visualizing a radiation therapy beam shape and fluence in real time. The effects of salient parameters have been characterized and will enable further optimization of the technique as it is implemented into the clinical workflow. The project described was supported by the National Center for Advancing Translational Sciences of the National Institutes of Health through UL1 TR001085.

60 APPLIED LIFE SCIENCES↗

Flexible radioluminescence imaging for FDG-guided surgery

Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with the head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.

60 APPLIED LIFE SCIENCES↗