Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital image correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

An Automated Mapping Processor Using C-Band Interferometric SAR Data

We present the description of a processor which has been implemented to generate map products starting from C-band interferometric data. The first stage of the processor consists of the conventional interferometric SAR processing producing a Digital Elevation Model (DEMs) and a SAR brightness image in sensor coordinates. In the second stage of processing, a land use classification map is obtained by using the DEM, brightness, and interferometric correlation layers. Auxiliary layers which include a drainage layer, a height gradient layer, a height error layer, an estimated penetration layer, and a shaded relief layer are also computed. In the final step, all UTM collocated layers are combined in a GIS system which allows for both hard copy map products and for digital applications.

Rodriguez, E.↗

An Automated Mapping Processor using C-Band Interferometric SAR Data

We describe a processor which has been implemented to generate map products starting from C-band interferometric data. The first stage of the processor consists of the conventional interferometric synthetic aperture radar (SAR) processing producing a digital elevation model (DEM) and a SAR brightness image in sensor coordinates. In the second stage of processing, a land use classification map is obtained by using the DEM, brightness, and interferometric correlation layers. Auxiliary layers which include a drainage layer, a height gradient layer, a height error layer, an estimated penetration layer, and a shaded relief layer are also computed. In the final step, all UTM collocated layers are combined in a geographical information system (GIS) which allows for both hard copy map products and digital applications.

Rodriguez, E.↗

Evaluation of lunar rocks and soils for resource utilization: Detailed image analysis of raw materials and beneficiated products

The rocks and soils of the Moon will be the raw materials for fuels and construction needs at a lunar base. This includes sources of materials for the generation of hydrogen, oxygen, metals, and other potential construction materials. For most of the bulk material needs, the regolith, and its less than 1 cm fraction, the soil, will suffice. But for specific mineral resources, it may be necessary to concentrate minerals from rocks or soils, and it is not always obvious which is the more appropriate feedstock. Besides an appreciation of site geology, the mineralogy and petrography of local rocks and soils is important for consideration of the resources which can provide feedstocks of ilmenite, glass, agglutinates, anorthite, etc. In such studies, it is very time-consuming and practically impossible to correlate particle counts (the traditional method of characterizing lunar soil petrography) with accurate modal analyses and with mineral associations in multi-mineralic grains. But x ray digital imaging, using x rays characteristic of each element, makes all this possible and much more (e.g., size and shape analysis). An application of beneficiation image analysis, in use in our lab (Oxford Instr. EDS and Cameca SX-50 EMP), was demonstrated to study mineral liberation from lunar rocks and soils. Results of x ray image analysis are presented.

Taylor, Lawrence A.↗

Decay Spectroscopy of {sup 45}Fe

In an experiment performed at the NSCL/MSU A1900 separator the decay of {sup 45}Fe was investigated in detail. Two-proton radioactivity channel was clearly identified and for the first time the correlations between two protons emitted from the nuclear ground state were determined. The comparison with a theoretical model indicates the genuine three-body character of this decay and sheds light on the shell structure of this exotic nucleus. The {beta} decay channels of {sup 45}Fe, followed by one-, two-, and three-proton emission, were also identified. The {beta}3p decay channel was observed for the first time. The half-life of {sup 45}Fe was found to be 2.6{+-}0.2 ms and the 2p decay branching ratio is 70{+-}4%. In the experiment a new type of gaseous detector has been applied in which a technique of digital imaging was used to record tracks of charged particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanoadaptive strain and functional osseointegration of dental implants in rats

Spatiotemporal implant-bone biomechanics and mechanoadaptive strains in peri-implant tissue are poorly understood. Physical and chemical characteristics of an implant-bone complex (IBC) were correlated in three-dimensional space (along the length and around a dental implant) to gather insights into time related integration of the implant with the cortical portion of a jaw bone in a rat. Rats (N = 9) were divided into three experimental groups with three rats per time point; 3-, 11-, and 24-day. All rats were fed crumbled hard pellets mixed with water (soft-food diet) for the first 3 days followed by a hard-food diet with intact hard-food pellets (groups of 11- and 24-day only). Biomechanics of the IBCs harvested from rats at each time point was evaluated by performing mechanical testing in situ in tandem with X-ray imaging. The effect of physical association (contact area) of a loaded implant with adapting peri-implant tissue, and resulting strain within was mapped by using digital volume correlation (DVC) technique. The IBC stiffness at respective time points was correlated with mechanical strain in peri-implant tissue. Results illustrated that IBC stiffness at 11-day was lower than that observed at 3-day. However, at 24-day, IBC stiffness recovered to that which was observed at 3-day. Furthermore, correlative microscopy and spectroscopy illustrated that the lower IBC stiffness was constituted by softer and less mineralized peri-implant tissue that contained varying expressions of osteoconductive elements. Lower IBC stiffness observed at 11-day was constituted by less mineralized peri-implant tissue with osteoconductive elements that included phosphorus (P) which was co-localized with higher expression of zinc (Zn), and lower expression of calcium (Ca). Higher IBC stiffness at 24-day was constituted by mineralized peri-implant tissue with higher expressions of osteoconductive elements including Ca and P, and lower expressions of Zn. These spatiotemporal correlative maps of peri-implant tissue architecture, heterogeneous distribution of mineral density, and elemental colocalization underscore mechanoadaptive physicochemical properties of peri-implant tissue that facilitate functional osseointegration of an implant. These results provided insights into 1) plausible "prescription" of mechanical loads as an osteoinductive "therapeutic dose" to encourage osteoconductive elements in the peri-implant tissue that would facilitate functional osseointegration of the implant; 2) a "critical temporal window" between 3 and 11 days, and perhaps it is this acute phase during which key candidate regenerative molecules can be harnessed to accelerate osseointegration of an implant under load.

60 APPLIED LIFE SCIENCES↗

Task-based weights for photon counting spectral x-ray imaging

Purpose: To develop a framework for taking the spatial frequency composition of an imaging task into account when determining optimal bin weight factors for photon counting energy sensitive x-ray systems. A second purpose of the investigation is to evaluate the possible improvement compared to using pixel based weights. Methods: The Fourier based approach of imaging performance and detectability index d' is applied to pulse height discriminating photon counting systems. The dependency of d' on the bin weight factors is made explicit, taking into account both differences in signal and noise transfer characteristics across bins and the spatial frequency dependency of interbin correlations from reabsorbed scatter. Using a simplified model of a specific silicon detector, d' values for a high and a low frequency imaging task are determined for optimal weights and compared to pixel based weights. Results: The method successfully identifies bins where a large point spread function degrades detection of high spatial frequency targets. The method is also successful in determining how to downweigh highly correlated bins. Quantitative predictions for the simplified silicon detector model indicate that improvements in the detectability index when applying task-based weights instead of pixel based weights are small for high frequency targets, but could be in excess of 10% for low frequency tasks where scatter-induced correlation otherwise degrade detectability. Conclusions: The proposed method makes the spatial frequency dependency of complex correlation structures between bins and their effect on the system detective quantum efficiency easier to analyze and allows optimizing bin weights for given imaging tasks. A potential increase in detectability of double digit percents in silicon detector systems operated at typical CT energies (100 kVp) merits further evaluation on a real system. The method is noted to be of higher relevance for silicon detectors than for cadmium (zink) telluride detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radar image preprocessing

Standard image processing techniques are not applicable to radar images because of the coherent nature of the sensor. Therefore there is a need to develop preprocessing techniques for radar images which will then allow these standard methods to be applied. A random field model for radar image data is developed. This model describes the image data as the result of a multiplicative-convolved process. Standard techniques, those based on additive noise and homomorphic processing are not directly applicable to this class of sensor data. Therefore, a minimum mean square error (MMSE) filter was designed to treat this class of sensor data. The resulting filter was implemented in an adaptive format to account for changes in local statistics and edges. A radar image processing technique which provides the MMSE estimate inside homogeneous areas and tends to preserve edge structure was the result of this study. Digitally correlated Seasat-A synthetic aperture radar (SAR) imagery was used to test the technique.

Frost, V. S.↗

Macromolecular Topography Leaps into the Digital Age

A low-cost, real-time digital topography system is under development which will replace x-ray film and nuclear emulsion plates. The imaging system is based on an inexpensive surveillance camera that offers a 1000x1000 array of 8 im square pixels, anti-blooming circuitry, and very quick read out. Currently, the system directly converts x-rays to an image with no phosphor. The system is small and light and can be easily adapted to work with other crystallographic equipment. Preliminary images have been acquired of cubic insulin at the NSLS x26c beam line. NSLS x26c was configured for unfocused monochromatic radiation. Six reflections were collected with stills spaced from 0.002 to 0.001 degrees apart across the entire oscillation range that the reflections were in diffracting condition. All of the reflections were rotated to the vertical to reduce Lorentz and beam related effects. This particular CCD is designed for short exposure applications (much less than 1 sec) and so has a relatively high dark current leading to noisy raw images. The images are processed to remove background and other system noise with a multi-step approach including the use of wavelets, histogram, and mean window filtering. After processing, animations were constructed with the corresponding reflection profile to show the diffraction of the crystal volume vs. the oscillation angle as well as composite images showing the parts of the crystal with the strongest diffraction for each reflection. The final goal is to correlate features seen in reflection profiles captured with fine phi slicing to those seen in the topography images. With this development macromolecular topography finally comes into the digital age.

Lovelace, J.↗

An image-based technique to assess the perceptual quality of clinical chest radiographs

Purpose: Current clinical image quality assessment techniques mainly analyze image quality for the imaging system in terms of factors such as the capture system modulation transfer function, noise power spectrum, detective quantum efficiency, and the exposure technique. While these elements form the basic underlying components of image quality, when assessing a clinical image, radiologists seldom refer to these factors, but rather examine several specific regions of the displayed patient images, further impacted by a particular image processing method applied, to see whether the image is suitable for diagnosis. In this paper, the authors developed a novel strategy to simulate radiologists' perceptual evaluation process on actual clinical chest images. Methods: Ten regional based perceptual attributes of chest radiographs were determined through an observer study. Those included lung grey level, lung detail, lung noise, rib-lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm-lung contrast, and subdiaphragm area. Each attribute was characterized in terms of a physical quantity measured from the image algorithmically using an automated process. A pilot observer study was performed on 333 digital chest radiographs, which included 179 PA images with 10:1 ratio grids (set 1) and 154 AP images without grids (set 2), to ascertain the correlation between image perceptual attributes and physical quantitative measurements. To determine the acceptable range of each perceptual attribute, a preliminary quality consistency range was defined based on the preferred 80% of images in set 1. Mean value difference ({mu}{sub 1}-{mu}{sub 2}) and variance ratio ({sigma}{sub 1}{sup 2}/{sigma}{sub 2}{sup 2}) were investigated to further quantify the differences between the selected two image sets. Results: The pilot observer study demonstrated that our regional based physical quantity metrics of chest radiographs correlated very well with their corresponding perceptual attributes. The distribution comparisons, mean value difference estimations, and variance ratio estimations of each physical quantity between sets of images from two different techniques matched our expectation that the image quality of set 1 should be better than that of set 2. Conclusions: The measured physical quantities provide a robust reflection of perceptual image quality in clinical images. The methodology can be readily applied for automated evaluation of perceptual image quality in clinical chest radiographs.

60 APPLIED LIFE SCIENCES↗

Interdisciplinary applications and interpretations of EREP data within the Susquehanna River Basin

The author has identified the following significant results. Photography from the S190A and S190B sensors was compared, for terrain analysis. The S190B photographs were used for terrain mapping of three test areas selected as being representative of major physiographic regions in Pennsylvania. Skylab photography was superior to both LANDSAT imagery and high altitude aircraft photography for purposes of accurate location of lineaments. Analysis of Skylab imagery has shown that long lineaments originally plotted on LANDSAT images are actually made up of shorter segments. Correlation of lineaments with ore deposits was determined following the preparation of a Pennsylvania mineral deposit map. Digital wave number analysis (spatial filtering) was attempted to determine if it can be used to enhance certain subtle features, and in particular, to locate and verify lineaments. Various spectral bands and channels of the MSS digital data were evaluated for their value in the classification and thematic mapping.

Mcmurtry, G. J.↗

A Preliminary Analysis of LANDSAT-4 Thematic Mapper Radiometric Performance

The NASA raw (BT) product, the radiometrically corrected (AT) product, and the radiometrically and geometrically corrected (PT) product of a TM scene were analyzed examine the frequency distribution of the digital data; the statistical correlation between the bands; and the variability between the detectors within a band. The analyses were performed on a series of image subsets from the full scence. Results are presented from one 1024 c 1024 pixel subset of Realfoot Lake, Tennessee which displayed a representative range of ground conditions and cover types occurring within the full frame image. From this cursory examination of one of the first seven channel TM data sets, it would appear that the radiometric performance of the system is most satisfactory and largely meets pre-launch specifications. Problems were noted with Band 5 Detector 3 and Band 2 Detector 4. Differences were observed between forward and reverse scan detector responses both for the BT and AT products. No systematic variations were observed between odd and even detectors.

Justice, C.↗

A novel approach to assess the treatment response using Gaussian random field in PET

Purpose: The assessment of early therapeutic response to anticancer therapy is vital for treatment planning and patient management in clinic. With the development of personal treatment plan, the early treatment response, especially before any anatomically apparent changes after treatment, becomes urgent need in clinic. Positron emission tomography (PET) imaging serves an important role in clinical oncology for tumor detection, staging, and therapy response assessment. Many studies on therapy response involve interpretation of differences between two PET images, usually in terms of standardized uptake values (SUVs). However, the quantitative accuracy of this measurement is limited. This work proposes a statistically robust approach for therapy response assessment based on Gaussian random field (GRF) to provide a statistically more meaningful scale to evaluate therapy effects. Methods: The authors propose a new criterion for therapeutic assessment by incorporating image noise into traditional SUV method. An analytical method based on the approximate expressions of the Fisher information matrix was applied to model the variance of individual pixels in reconstructed images. A zero mean unit variance GRF under the null hypothesis (no response to therapy) was obtained by normalizing each pixel of the post-therapy image with the mean and standard deviation of the pretherapy image. The performance of the proposed method was evaluated by Monte Carlo simulation, where XCAT phantoms (128{sup 2} pixels) with lesions of various diameters (2–6 mm), multiple tumor-to-background contrasts (3–10), and different changes in intensity (6.25%–30%) were used. The receiver operating characteristic curves and the corresponding areas under the curve were computed for both the proposed method and the traditional methods whose figure of merit is the percentage change of SUVs. The formula for the false positive rate (FPR) estimation was developed for the proposed therapy response assessment utilizing local average method based on random field. The accuracy of the estimation was validated in terms of Euler distance and correlation coefficient. Results: It is shown that the performance of therapy response assessment is significantly improved by the introduction of variance with a higher area under the curve (97.3%) than SUVmean (91.4%) and SUVmax (82.0%). In addition, the FPR estimation serves as a good prediction for the specificity of the proposed method, consistent with simulation outcome with ∼1 correlation coefficient. Conclusions: In this work, the authors developed a method to evaluate therapy response from PET images, which were modeled as Gaussian random field. The digital phantom simulations demonstrated that the proposed method achieved a large reduction in statistical variability through incorporating knowledge of the variance of the original Gaussian random field. The proposed method has the potential to enable prediction of early treatment response and shows promise for application to clinical practice. In future work, the authors will report on the robustness of the estimation theory for application to clinical practice of therapy response evaluation, which pertains to binary discrimination tasks at a fixed location in the image such as detection of small and weak lesion.

61 RADIATION PROTECTION AND DOSIMETRY↗

Long-term Study of the Solar Filaments from the Synoptic Maps as Derived from H{sub α} Spectroheliograms of the Kodaikanal Observatory

The century long (1914–2007) H{sub α} (656.28 nm) spectroheliograms from the Kodaikanal Solar Observatory (KSO) have been recently digitized. Using these newly calibrated, processed images we study the evolution of dark elongated on-disk structures called filaments, which are potential representatives of magnetic activities on the Sun. To our knowledge, this is the oldest uniform digitized data set with daily images available today in H{sub α}. We generate Carrington maps for the entire time duration and try to find the correlations with maps of the same Carrington rotation from the Ca ii K KSO data. Filaments are segmented from the Carrington maps using a semi-automated technique and are studied individually to extract their centroids and tilts. We plot the time-latitude distribution of the filament centroids, producing a butterfly diagram which clearly shows the presence of poleward migration. We separate polar filaments for each cycle and try to estimate the delay between the polar filament number cycle and the sunspot number cycle peaks. We correlate this delay with the delay between polar reversal and sunspot number maxima. This provides new insight on the role of polar filaments on polar reversal.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility study consisting of a review of contour generation methods from stereograms

A review of techniques for obtaining contour information from stereo pairs is given. Photogrammetric principles including a description of stereoscopic vision are presented. The use of conventional contour generation methods, such as the photogrammetric plotting technique, electronic correlator, and digital correlator are described. Coherent optical techniques for contour generation are discussed and compared to the electronic correlator. The optical techniques are divided into two categories: (1) image plane operation and (2) frequency plane operation. The description of image plane correlators are further divided into three categories: (1) image to image correlator, (2) interferometric correlator, and (3) positive negative transparencies. The frequency plane correlators are divided into two categories: (1) correlation of Fourier transforms, and (2) filtering techniques.

Kim, C. J.↗

Geometric and rediametric distortion in spaceborne SAR imagery

Distortions inherent on synthetic aperture radio (SAR) imagery and the development to date of unsupervised postprocessing rectification techniques are described. The geometric distortion can be divided into two categories: (1) distortion derived from the radar viewing geometry, this includes such effects as ground range nonlinearities, radar foreshortening and radar layover; (2) distortion introduced during the data processing, these distortions result from approximations made during the correlation such as in estimation of the target phase history, or compensation for the earth rotation. The processor induced distortions depends on the specific correlation algorithm used for image formation. The effects are addressed on the image product resulting from assumptions during the processing and it specifically considers distortions inherent in digital imagery produced by the digital image processor.

Curlander, J. C.↗

Antimisting kerosene atomization and flammability

Various parameters found to affect the flammability of antimisting kerosene (Jet A + polymer additive) are investigated. Digital image processing was integrated into a technique for measurement of fuel spray characteristics. This technique was developed to avoid many of the error sources inherent to other spray assessment techniques and was applied to the study of engine fuel nozzle atomization performance with Jet A and antimisting fuel. Aircraft accident fuel spill and ignition dynamics were modeled in a steady state simulator allowing flammability to be measured as a function of airspeed, fuel flow rate, fuel jet Reynolds number and polymer concentration. The digital imaging technique was employed to measure spray characteristics in this simulation and these results were related to flammability test results. Scaling relationships were investigated through correlation of experimental results with characteristic dimensions spanning more than two orders of magnitude.

Fleeter, R.↗

Integrated-Circuit Active Digital Filter

Pipeline architecture with parallel multipliers and adders speeds calculation of weighted sums. Picture-element values and partial sums flow through delay-adder modules. After each cycle or time unit of calculation, each value in filter moves one position right. Digital integrated-circuit chips with pipeline architecture rapidly move 35 X 35 two-dimensional convolutions. Need for such circuits in image enhancement, data filtering, correlation, pattern extraction, and synthetic-aperture-radar image processing: all require repeated calculations of weighted sums of values from images or two-dimensional arrays of data.

Nathan, R.↗

Digital simulation of the SIR-C sensor electronics

In this paper software for simulation of the response of the SIR-C sensor to a point target is described. Synthetic SAR data is generated by passing successive chirps through a simulation of the transmitter electronics, propagation path and receiver electronics. This result is then processed with a digital correlator to yield the point target response of the system. This allows an accurate assessment of the effect of the radar design on the final image product.

Klein, Jeffrey D.↗