Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Many-body Nuclear Dynamics

The principal goal of this work was to better understand the fusion of neutron-rich nuclei a topic relevant to the fields of both nuclear physics and nuclear astrophysics. The work provides insight into the structure and reactions of neutron-rich nuclei namely the extent of their neutron density distribution and its polarizability. By comparing the fusion excitation functions for a chain of isotopes with a common target nucleus changes in the attractive nuclear potential are assessed. This change in the attractive potential is related to changes in the neutron density distribution with increasing number of neutrons or changes in fusion dynamics with increasing neutron number. The impact of the pairing of valence neutrons and protons on the fusion cross-section is also examined. Measurement of an isotopic chain is a powerful tool to address this topic. The experimental program made use of several different accelerator facilities. The core of the experimental work involved experiments at the ReA3 accelerator and the Facility for Rare Isotope Beams (FRIB) situated at Michigan State University, at GANIL, the French national nuclear physics laboratory, and the University of Notre Dame. At ReA3 the degree to which α-clusters associated with fusion of 28,30,32 Si + 28 Si result from the collision dynamics or reflect an initial α-cluster structure was explored. Alpha clusters observed in fusion reactions exceed the predictions of the standard statistical model. This experiment provides a measure of how clusterization is impacted by the increasing neutron-richess of the system. In the experiment at GANIL we investigated fusion in 19 O + 12 C and 20 O + 12 C. This experiment utilized the recently developed active-target detector MuSIC@Indiana. Using this proven, highly efficient, active-target detector we measured the fusion excitation function for these neutron-rich systems. Grounded by these experimental measurements, theoretical models were used to examine the role of unpaired valence neutrons on the fusion cross-section at energies just above the fusion barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Geant4 HEP Examples

Geant4 is a widely used simulation toolkit in high-energy physics (HEP), enabling precise modeling of particle interactions with matter. It plays a crucial role in the development and optimization of detector concepts for future HEP programs. With a structured set of examples ranging from basic to advanced, Geant4 provides a comprehensive set of concrete examples for users at different expertise levels. As a critical tool for the HEP community, Geant4 continues to evolve, adapting to emerging computational paradigms and experimental requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next Generation Sensor Development (CRADA Final Report)

B. Project Scope This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS), as manager and operator of Lawrence Livermore National Laboratory (LLNL) and The Federal Reserve Bank of San Francisco ("FRBSF" or "Participant"), to research and develop advanced processing techniques to measure the fitness and authenticity of U.S. currency. The FRBSF previously partnered with LLNL to evaluate end-of-life predictions, review sensor requirements, develop communications protocols, and perform thermal analysis. These Strategic Partnership Projects (SPP) included SPP No. L20960 - Federal Reserve Currency Technology Office Studies, SPP No. L15900 - Development of a Common Detector Interface (CDI 2.0) Specification and Hardware Simulators, and SPP No. L15610 - Limited Design Review of a Second-Generation E-Material Authentication Sensor (EMAS2).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Versatile Link+ Transceiver Production Readiness

The Versatile Link + project is about to enter its production phase, ready for the Phase 2 HL-LHC detector upgrades. We present the status of the front-end part of the Versatile Link$^+$ project: the Versatile Link$^+$ Transceiver, which provides a low-mass, radiation tolerant, optical transmit- and receive module for tight integration in the upgrading HL-LHC detectors. We describe the development and thorough testing carried out with the transceiver prototypes and their sub-components and the design decisions that have led to the final production-ready prototype. The planned production schedule is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Fundamental principles of absolute radiometry and the philosophy of this NBS program (1968 to 1971)

A description is given work performed on a program to develop an electrically calibrated detector (also called absolute radiometer, absolute detector, and electrically calibrated radiometer) that could be used to realize, maintain, and transfer a scale of total irradiance. The program includes a comprehensive investigation of the theoretical basis of absolute detector radiometry, as well as the design and construction of a number of detectors. A theoretical analysis of the sources of error is also included.

Geist, J.↗

On charged particle tracks in cellulose nitrate and Lexan

Investigations were performed aimed at developing plastic nuclear track detectors into quantitative tools for recording and measuring multicharged, heavy particles. Accurate track etch rate measurements as a function of LET were performed for cellulose nitrate and Lexan plastic detectors. This was done using a variety of incident charged particle types and energies. The effect of aging of latent tracks in Lexan in different gaseous atmospheres was investigated. Range distributions of high energy N-14 particle bevatron beams in nuclear emulsion were measured. Investigation of charge resolution and Bragg peak measurements were carried out using plastic nuclear track detectors.

Benton, E. V.↗

The spectrum of cosmic electron with energies between 6 and 100 GeV

This experiment was carried out during three balloon flights which provided a total exposure of 3500 + or - 60 sq m sec sterad at an average depth of 4.8 g/sq cm The detector, in which the development of cascade showers in a 33.7 rl absorber was sampled by 10 scintillation counters and 216 Geiger-Muller tubes, was calibrated at the Cornell Electron Synchrotron, the separation of cosmic electrons from the nuclear background was confirmed by extensive analysis of data from the flights, from the calibration and from ground level exposure. The spectral intensity of primary cosmic ray electrons were found in particles/sq m sec sterad GeV. Similarly, the ground level spectrum of secondary cosmic ray electrons was also found. The steepness of the spectrum of cosmic electrons relative to that of nuclei implies one of the following conclusions: either the injection spectrum of electrons is steeper than that of nuclei, or the electron spectrum has been steepened by Compton/synchrotron losses in the energy range covered by the experiment.

Meegan, C. A.↗

Instrumentation for solar spectrophotometry at extreme ultraviolet and soft X-ray wavelengths

The solar extreme ultraviolet and soft X-ray (XUV) spectrum at wavelengths between 20 and 300 A contains a wealth of emission lines from ions formed at temperatures from 10 to the 5th K to greater than 2 x 10 to the 7th K. The requirements for high resolution spectrophotometric instrumentation are discussed in the light of data obtained with extreme ultraviolet and X-ray telescopes flown on Skylab. The design of a grazing-incidence spectroheliometer for active region and flare studies over the wavelength range from 40 to 630 A is presented and recently developed high-efficiency detectors and detector-arrays for use at XUV wavelengths are described.

Timothy, J. G.↗

Chemical Analysis of Outgassing Contaminants on Spacecraft Surfaces

Samples of S-13 paint on aluminum, reflection grating anomalies as affected by dielectric coatings, and rocket effluents were analyzed along with Skylab window scrapings and a gas activated semiconductor. Development of an HCl detector is also discussed. Results are briefly summarized.

Mcnutt, R. C.↗

Report of Optical Radiometric Instruments and Calibration Panel

Measurement and accuracy needs for remote sensing are analyzed. Topics discussed include: (1) in orbit performance degradation due to contamination; (2) increased radiometric accuracy required for detecting small changes over long periods of time in environmental parameters; (3) references for verifying calibration in orbit; (4) high attenuation neutral density filters; (5) the sun as a radiation source for testing; (6) rejection of stray light; (7) development of spectrally flat detectors for flight sensors; and (8) long term stability of sensor components.

Source record↗

Develop real-time dosimetry concepts and instrumentation for long term missions

The development of a rugged portable dosimetry system, based on microdosimetry techniques, which will measure dose and evaluate dose equivalent in a mixed radiation field is described. Progress in the desired dosimetry system can be divided into three distinct areas: development of the radiation detector, and electron system are presented. The mathematical techniques required are investigated.

Braby, L. A.↗

A computer controlled television detector for light, X-rays and particles

A versatile, high resolution, software configurable, two-dimensional intensified vidicon quantum detector system has been developed for multiple research applications. A thin phosphor convertor allows the detection of X-rays below 20 keV and non-relativistic particles in addition to visible light, and a thicker scintillator can be used to detect X-rays up to 100 keV and relativistic particles. Faceplates may be changed to allow any active area from 1 to 40 mm square, and active areas up to 200 mm square are possible. The image is integrated in a digital memory on any software specified array size up to 4000 x 4000. The array size is selected to match the spatial resolution, which ranges from 10 to 100 microns depending on the operating mode, the active area, and the photon or particle energy. All scan and data acquisition parameters are under software control to allow optimal data collection for each application.

Kalata, K.↗

Cosmic X-ray physics

A progress report of research activities carried out in the area of cosmic X-ray physics is presented. The Diffuse X-ray Spectrometer DXS which has been flown twice as a rocket payload is described. The observation times proved to be too small for meaningful X-ray data to be obtained. Data collection and reduction activities from the Ultra-Soft X-ray background (UXT) instrument are described. UXT consists of three mechanically-collimated X-ray gas proportional counters with window/filter combinations which allow measurements in three energy bands, Be (80-110 eV), B (90-187 eV), and O (e84-532 eV). The Be band measurements provide an important constraint on local absorption of X-rays from the hot component of the local interstellar medium. Work has also continued on the development of a calorimetric detector for high-resolution spectroscopy in the 0.1 keV - 8keV energy range.

Mccammon, D.↗