Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Quasiperiodic behavior in beam-driven strong Langmuir turbulence

The evolution of unmagnetized beam-driven strong Langmuir turbulence is studied in two dimensions by numerically integrating the Zakharov equations for systems pumped by monochromatic and broadband negative-damping drivers with nonzero central wavenumber. Long-time statistically steady states are reached for which the dependence of the evolution on the driver wavenumber, growth rate, and bandwidth is examined in detail. For monochromatic drivers, a quasiperiodic cycle is found to develop if the driver wavenumber is sufficiently large. The characteristic frequency of the quasiperiodic cycle and the average system energy are both approximately proportional to the growth rate. Broadening of the driver in wavenumber tends to degrade the system-wide coherence of the cycle, but its main features appear to survive on the scale of the coherence length of the driver.

Robinson, P. A.↗

Low earth simulation and materials characterization

Oxygen plasma ashers and an electron cyclotron resonance (ECR) sources are currently being used for low Earth orbit (LEO) simulation. The suitability of each of these simulation techniques is considered. Thin film coatings are characterized by optical techniques, including variable-angle spectroscopic ellipsometry, optical spectrophotometry, and laser light scatterometry. Atomic force microscopy (AFM) has been used to characterize the surface morphology of thin aluminum films as a function of substrate temperature during deposition. Results on diamondlike carbon (DLC) films show that DLC degrades with simulated atomic oxygen (AO) exposure at a rate comparable to Kapton polyimide. Since DLC is not as susceptible as Kapton to environmental factors such as moisture absorption, it could potentially provide more accurate measurements of AO fluence on short space flights.

Synowicki, R. A.↗

Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics

We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. We also present data on the susceptibility of parts to functional degradation resulting from total ionizing dose at low dose rates (0.003-0.33 Rads(Si)/s). Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog to Digital Converters (ADCs), Digital to Analog Converters (DACs), and DC-DC converters, among others.

OBryan, Martha V.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

Quantitative Prediction of Perovskite Stability Using Accelerated Testing and Machine Learning

PV technologies based on hybrid perovskites offer the potential for reducing solar cell costs, but they are particularly vulnerable to degradation by environmental factors such as moisture, oxygen, and illumination. Commercialization will require not only stable materials and device architectures but also accelerated testing protocols and models that can predict degradation from the accelerated testing data. Here, we report results from in situ photoluminescence (PL) and photoconductivity (PC) measurements during perovskite degradation with simultaneous optical transmittance (Tr) measurements or reflected dark field (DF) imaging. From PL, PC, Tr, and DF, we determine (respectively) the steady-state quasi-Fermi level splitting, the mean effective carrier diffusion length, the extent of conversion of perovskite to higher bandgap degradation products, and the extent of scattering from domains with different orientation or composition, all as a function of time during degradation. Simultaneous measurement of PL-PC-Tr or PL-PC-DF on perovskite absorbers in an environmental chamber over a wide range of humidity, oxygen, temperature, and illumination levels yields a rich data set. We use machine learning to develop a model that accurately predicts (within 10%) the time for the diffusion length to decrease to 85% of its initial value. The model takes the environmental conditions and the first few measurements from the PL-PC-Tr or PL-PC-DF experiment as input. Thus, the model provides a framework to interpret the results of accelerated testing of absorber materials. One of the dominant features in the model of degradation for CH 3 NH 3 PbI 3 is the initial rate at which transmittance increase. For devices with opaque contacts, the pixel-averaged rate of change of the intensity in dark-field images can be used in place of transmittance. Results are also presented on full PV devices with in-situ current-voltage (JV) measurements. Here, the data from simultaneous PL-DF-JV under environmental stresses reveal intimate connection between degradation and shunts and provide a framework to extend accelerated testing to devices. Further, the presentation reveals underlying universal behavior in degradation pathways over a broad range of environmental stresses and perovskite compositions.

14 SOLAR ENERGY↗

Technique to select the optimum modulation indices for suppression of undesired signals for simultaneous range and data operations

An algorithm to search for the optimum set of modulation indices that will optimize a given simultaneous range/command/telemetry communications link is presented. This technique provides a way to suppress the ranging signal in order to limit performance degradation in the data channel due to interference from the ranging channel to a desired level, given a specified ranging accuracy. The link (when optimized) will (1) provide maximum available power to both the data and ranging channels for a specified degradation in the data channel so that it will transmit at the required data rate, (2) achieve a specified ranging accuracy over a maximum distance, under a certain set of conditions, and (3) provide adequate power for carrier tracking without degrading the data-channel thresholds. In addition, both data and ranging channels will fall below the threshold at the same point.

Nguyen, Tien Manh↗

Correction of Path Integrated Attenuation Estimates Considering the Soil Moisture Effect for the Gpm Dual-Frequency Precipitation Radar

Spaceborne precipitation radars, including the Tropical Rainfall Measuring Mission’s Precipitation Radar (PR) and the Global Precipitation Measurement Mission’s Dual-Frequency Precipitation Radar (DPR), measure not only precipitation echoes but surface echoes as well, the latter of which are used to estimate the path-integrated attenuation (PIA) in the surface reference technique (SRT). In our previous study based on analyzing PR measurements, we found that attenuation-free surface backscattering cross sections (denoted by s0e) over land increased in the presence of precipitation. This behavior, called the soil moisture effect, causes an underestimate of the PIA by the SRT as the method does not explicitly consider this effect. In this study, measurements made by Ku-band Precipitation Radar (KuPR) and Ka-band Precipitation Radar (KaPR), which comprise the DPR, were analyzed to examine whether KuPR and KaPR exhibit similar dependencies on the soil moisture as does the PR. For both KuPR and KaPR, an increase in s0e was observed for a large portion of the land area, except for forests and deserts. Results from the Hitschfeld–Bordan (HB) method suggest that s0e increases with the surface precipitation rate for light precipitation events. Meanwhile, for heavy precipitation, owing to the degradation of the HB method, it is difficult to estimate s0e quantitatively. Thus, a correction method for PIA that considers the soil moisture effect was developed and implemented into the DPR standard algorithm. With this correction, the surface precipitation rate estimates increased by approximately 18%for KuPR and 15%for the normal scan of KaPR over land.

Shinta Seto↗

From Cell to System: Accelerated hpc Simulations of BESS Aging under Frequency Regulation and Arbitrage use cases

Lithium-ion battery energy storage systems (BESS) packs have emerged as a leading solution for grid-scale energy storage, enhancing resiliency and balancing load fluctuations. Yet, experimental characterization of large-format LIB packs-particularly to assess performance and degradation over hundreds of cycles - demands substantial hardware investment and multi-year testing campaigns. In this work, we couple a hierarchical, physics-based modeling framework agnostic to electrode chemistries with high-performance computing to accelerate systems level evaluation by upto two orders of magnitude. Building on the open-source liionpack platform, we implement cell, module, and pack-scale electrochemical models enriched with mechanistic aging mechanisms and deploy them on an HPC cluster to simulate 150−200kWh systems over 500 - 1,000 cycles with in days. We subject these virtual B ESS to both constant-current cycling and realistic grid service profiles spanning frequency regulation, ramp-rate support, and energy arbitrage-and quantify the resulting degradation patterns. Our results reveal that localized cell aging can induce substantial nonuniformity at module and pack levels, with service-specific cycling protocols driving distinct aging modes. This rapid, multiscale modeling approach provides a powerful design-space exploration tool for optimizing electrical architecture, control strategies, and operational schedules to prolong pack lifetime and lower total cost of ownership.

Ayalasomayajula, Surya [ORNL] (ORCID:0009000860788↗

Advanced modulation technology development for earth station demodulator applications. Coded modulation system development

A jointly optimized coded modulation system is described which was designed, built, and tested by COMSAT Laboratories for NASA LeRC which provides a bandwidth efficiency of 2 bits/s/Hz at an information rate of 160 Mbit/s. A high speed rate 8/9 encoder with a Viterbi decoder and an Octal PSK modem are used to achieve this. The BER performance is approximately 1 dB from the theoretically calculated value for this system at a BER of 5 E-7 under nominal conditions. The system operates in burst mode for downlink applications and tests have demonstrated very little degradation in performance with frequency and level offset. Unique word miss rate measurements were conducted which demonstrate reliable acquisition at low values of Eb/No. Codec self tests have verified the performance of this subsystem in a stand alone mode. The codec is capable of operation at a 200 Mbit/s information rate as demonstrated using a codec test set which introduces noise digitally. The measured performance is within 0.2 dB of the computer simulated predictions. A gate array implementation of the most time critical element of the high speed Viterbi decoder was completed. This gate array add-compare-select chip significantly reduces the power consumption and improves the manufacturability of the decoder. This chip has general application in the implementation of high speed Viterbi decoders.

Miller, Susan P.↗

Changes in the performance characteristics of a GaAs near infrared light emitting diode when exposed to various current and thermal stresses

The changes that occurred in the optical and electrical characteristics of a near infrared, GaAs light emitting diode, when operated under various levels and combinations of current and thermal stresses are discussed. A total of forty parts were operated for two thousand hours under eight different sets of dc current and ambient temperature conditions. Degradation in the radiant optical power of these devices was thirty-four percent when operated at their rated current and an ambient temperature of 298K (25 C). Derating the current and/or the thermal stress reduced the degradation of this parameter in approximately a linear manner. All degraded devices behaved similarly, exhibiting rapid nonlinear degradation followed by a gradual linear degradation and finally a period of stable operation. An attempt was made to correlate initial device condition to degradation during stress testing, but met with little success.

Thomas, E. F., Jr.↗

Comprehensive Data Analysis and Analytic Method Development for PBX9501 Material (FY2019 Annual Report of Aging and Lifetimes Program)

In the polymer bonded explosive (PBX) 9501, a binder consisting of 2.5 wt% nitroplasticizer (NP) and 2.5 wt% Estane R 5703 (Estane) is combined with 94.9 wt% of the high-explosive HMX and 0.1 wt% stabilizer. Because of its flexibility and tensile strength, this binder lowers the sensitivity and improves the manufacturability of PBX 9501. However, like many plasticizers comprised of low molecular weight components, NP has a tendency to diffuse out of the PBX 9501 matrix and can decompose at moderate temperatures into reactive byproducts, such as NO, NO 2 , H 2 O, and HNO x . Through oxidation and hydrolysis, these molecules can further degrade NP and Estane, ultimately degrading the properties of PBX 9501. While gaseous molecules can readily diffuse out of the PBX 9501 charges, the intermediates with lower volatility are more likely trapped in the condensed phase inside the charges and, in a closed system, will co-exist with Estane for an extended period of time creating an ongoing reactive environment. Understanding the rates of formation for these volatiles and intermediates during the NP degradation is therefore a critical prerequisite for understanding the long-term stability of polymeric binders used in munition systems. To work toward this ultimate goal, in the past year, we have conducted comprehensive studies on the physical properties of NP and finished three-year long aging experiment to understand the aging behavior of NP under thermal treatment. Important results are summarized in this annual report. Although NP is widely used in the DOE complex, their physical properties are rather scattered and inconsistent in the open literature. For example, there are at least two widely different values, 14.5°C and -15°C, for the melting point of NP. Although it is known that NP is a eutectic 50:50 mixture of BDNPA and BDNPF, their eutectic phase diagram is not well documented. Furthermore, the effect of temperature on the miscibility between water and eutectic BDNPA/F mixture is rarely reported. To fill these knowledge gaps, a large set of BDNPA/F mixtures with BDNPA concentration ranging from 0 to 100 wt% was analyzed using DSC techniques. In addition to determining the eutectic melt point as -25°C, a phase diagram of the BDNPA/F system was constructed from -30°C to 45°C. With this phase diagram, the phase transition temperatures and composition can be readily found for the BDNPA/F mixtures with various mass ratios.

36 MATERIALS SCIENCE↗

Polymers Erosion and Contamination Experiment Being Developed

The Polymers Erosion and Contamination Experiment (PEACE) is currently being developed at the NASA Lewis Research Center by the Electro-Physics Branch in conjunction with students and faculty from Hathaway Brown School in Cleveland. The experiment is a Get Away Special Canister shuttle flight experiment sponsored by the American Chemical Society. The two goals of this experiment are (1) to measure ram atomic oxygen erosion rates of approximately 40 polymers that have potential use in space applications and (2) to validate a method for identifying sources of silicone contamination that occur in the shuttle bay. Equipment to be used in this flight experiment is shown in the schematic diagram. Spacecraft materials subjected to attack by atomic oxygen in the space environment experience significant degradation over the span of a typical mission. Therefore, learning the rates of atomic oxygen erosion of a wide variety of polymers would be of great benefit to future missions. PEACE will use two independent techniques to determine the atomic oxygen erosion rates of polymers. Large (1-in.-diameter) samples will be used for obtaining mass loss. Preflight and postflight dehydrated masses will be obtained, and the mass lost during flight will be determined. Small (0.5-in.-diameter) samples will be protected with isolated particles (such as NaCl crystals) and then exposed to the space environment. After flight, the protective particles will be removed (washed off) and atomic force microscopy (AFM) will be used to measure the erosion depth from protected mesas. Erosion depth measurements are more sensitive than traditional mass measurements and are very useful for materials with low erosion yields or with very low fluence missions.

deGroh, Kim K.↗

Sensor Spatial Distortion, Visual Latency, and Update Rate Effects on 3D Tracking in Virtual Environments

Several common defects that we have sought to minimize in immersing virtual environments are: static sensor spatial distortion, visual latency, and low update rates. Human performance within our environments during large amplitude 3D tracking was assessed by objective and subjective methods in the presence and absence of these defects. Results show that 1) removal of our relatively small spatial sensor distortion had minor effects on the tracking activity, 2) an Adapted Cooper-Harper controllability scale proved the most sensitive subjective indicator of the degradation of dynamic fidelity caused by increasing latency and decreasing frame rates, and 3) performance, as measured by normalized RMS tracking error or subjective impressions, was more markedly influenced by changing visual latency than by update rate.

Ellis, S. R.↗

Effects of Strain Rate and Surface Finish on Tensile Properties in High Pressure Hydrogen — A Case Study for LP-DED NASA HR-1

NASA has advanced NASA HR-1 as a solution for liquid rocket engine components that operate in hydrogen rich environments using various AM techniques. The NASA HR-1 for AM applications was specifically formulated for high ductility in high pressure gaseous hydrogen environment in addition to high strength and low cycle fatigue (LCF) resistance. NASA HR-1 meets materials requirements for liquid rocket engine components, including good hydrogen resistance, high conductivity, good LCF performance, and high elongation and strength for components in medium heat flux environments. NASA has completed fabrication of several subscale and full-scale channel wall nozzles in LP-DED NASA HR-1 and completed hot-fire testing. This includes refinement of the process to produce thin-walls and various channel geometries to meet the requirements for channel wall nozzle applications. The main objective of this investigation is to better understand the effects of tensile test strain rate and specimen surface finish on the amount of tensile ductility degradation in high pressure gaseous hydrogen environments. Performing smooth tensile tests in high pressure hydrogen and nitrogen environments can serve as a rapid and economical screening method to determine the relative susceptibility of materials to HEE. This paper presents the tensile test results for LP-DED NASA HR-1 in hydrogen and details the material evaluation on the effects of strain rate and surface finish condition on surface cracking behavior and fracture characteristics. The resistance to HEE for LP-DED NASA HR-1 and the wrought alloy is compared under the same testing conditions. Loss of tensile ductility is quantified in terms of changes in elongation at failure in hydrogen to compare HEE susceptibility. The most suitable strain rate and specimen surface finish condition for future HEE screening testing at MSFC are recommended.

Additive manufacturing↗

"Ultra"-Fast Fracture Strength of Advanced Structural Ceramic Materials Studied at Elevated Temperatures

The accurate determination of inert strength is important in reliable life prediction of structural ceramic components. At ambient temperature, the inert strength of a brittle material is typically regarded as free of the effects of slow crack growth due to stress corrosion. Therefore, the inert strength can be determined either by eliminating active species, especially moisture, with an appropriate inert medium, or by using a very high test rate. However, at elevated temperatures, the concept or definition of the inert strength of brittle ceramic materials is not clear, since temperature itself is a degrading environment, resulting in strength degradation through slow crack growth and/or creep. Since the mechanism to control strength is rate-dependent viscous flow, the only conceivable way to determine the inert strength at elevated temperatures is to utilize a very fast test rate that either minimizes the time for or eliminates slow crack growth. Few experimental studies have measured the elevated-temperature, inert (or "ultra"-fast fracture) strength of advanced ceramics. At the NASA Lewis Research Center, an experimental study was initiated to better understand the "ultra"-fast fracture strength behavior of advanced ceramics at elevated temperatures. Fourteen advanced ceramics - one alumina, eleven silicon nitrides, and two silicon carbides - have been tested using constant stress-rate (dynamic fatigue) testing in flexure with a series of stress rates including the "ultra"-fast stress rate of 33 000 MPa/sec with digitally controlled test frames. The results for these 14 advanced ceramics indicate that, notwithstanding possible changes in flaw populations as well as flaw configurations because of elevated temperatures, the strength at 33 000 MPa/sec approached the room-temperature strength or reached a higher value than that determined at the conventional test rate of 30 MPa/sec. On the basis of the experimental data, it can be stated that the elevated-temperature, inert strength of an advanced ceramic material can be defined as the strength where no slow crack growth takes place at the temperature.

Choi, Sung R.↗

Gamma Radiation-Induced Degradation of Acetohydroxamic Acid (AHA) in Aqueous Nitrate and Nitric Acid Solutions Evaluated by Multiscale Modelling

Acetohydroxamic acid (AHA) has been proposed for inclusion in advanced, single-cycle, used nuclear fuel reprocessing solvent systems for the reduction and complexation of plutonium and neptunium ions. For this application, a detailed description of the degradation of AHA in dilute aqueous nitric acid is required. To this end, we present a comprehensive, multiscale computer model for the coupled radiolytic and hydrolytic degradation of AHA in aqueous sodium nitrate and nitric acid solutions. Rate coefficients for the reactions of AHA and HA with the oxidizing nitrate radical were measured for the first time using pulsed electron radiolysis and used as inputs in the kinetic model. The computer model results are validated by comparison to experimental data from steady state gamma irradiations, for which the agreement is excellent. Here, the presented model accurately predicts the yields of the major degradation products of AHA: acetic acid, hydroxylamine, nitrous oxide, and molecular hydrogen.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characteristics of a gelled liquid hyprogen polyphenylene oxide (PPO) foam open-cell insulation system, phase 1

A large scale gel production and storage facility and a small scale facility, the latter used for detailed visual examination of the gel/PPO foam interface, were developed. A subcontract was given to investigate techniques for the production of gelled liquid hydrogen, develop a process design for scale-up to a 1.89 cu m (500 gallon) gel production and storage facility, determine gel transfer characteristics, determine the solubility rate of gaseous helium in the gel, and investigate the gross gel/PPO foam interfacial phenomena. An inside-tank process for scaled-up production of gelled liquid hydrogen was selected. No detectable gel structure degradation occurred during repeated shearing. The viscosity of gelled liquid hydrogen at shear rates of 300/sec and higher is 2 to 5-fold greater than that of neat liquid hydrogen. No clogging problems were encountered during the transfer of gelled liquid hydrogen through warmed transfer lines. The solubility rate of helium in liquid hydrogen was significantly reduced by the presence of gel structure. The boil-off rates from gelled liquid hydrogen were reduced from 25 to 50 percent compared to those observed for the neat liquid hydrogen under compatible conditions. The polyphenylene oxide (PPO) foam insulation was found to be compatible with liquid ethane.

Source record↗