Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

RHIC 12x150A current lead temperature controller: design and implementation

There are 60 12 x 150A current leads distributed in six RHIC service buildings; each lead delivers power supply current from room temperature to cryogenic temperature in RHIC. Due to the humid environment, condensation occurs frequently and ice forms quickly during operation, especially during an extensive storage period. These conditions generate warnings and alarms to which personnel must respond and establish temporary solutions to keep the machine operating. In here, we designed a temperature control system to avoid such situations. This paper discusses its design, implementation, and some results. There are six service buildings in the RHIC complex; each building has two valve boxes that transfer room-temperature current cables from the power supplies into superconducting leads, and then transport them into the RHIC tunnel. In there, the transition between the room-temperature lead into superconducting lead is critical and essential; smooth running during the physics store is crucial for the machine's continuing operation. One of the problems that often occurred previously was the icing of these current leads that could result in a potential leakage current onto ground, thereby preventing a continuous supply of physics store. Fig. 1 illustrates a typical example on a power lead. Among the modifications of the design of the valve box, we list below the new requirements for designing the temperature controller to prevent icing occurring: (1) Remotely control, monitor, and record each current lead's temperature in real time. Prevent icing or overheating of a power lead. (2) Include a temperature alarm for the high/low level threshold. In this paper we discuss the design, implementation, upgrades to, and operation of this new system.

43 PARTICLE ACCELERATORS↗

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Testing of 3-meter Prototype Fault Current Limiting Cables

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation on Effect of Magnetic Field Dependency Coefficient of Critical Current Density on the AC Magnetizing Loss in HTS Tapes Exposed to External Field

High-temperature superconducting (HTS) technology is the most promising, advanced, and beneficial technological developments of the last two decades in terms of fabricating more efficient, compact, and reliable electrical power apparatus. The second-generation HTS wires are now quite competitive with traditional conductors from the cost point of view. In addition, they are of high interest in electrical machine manufacturing due to their unique merits such as high current density, high magnetic field, and low loss. The most significant issue for any superconducting devices which work with alternating current or magnetic field is the AC loss of the HTS tapes. Since HTS tapes are always exposed to an external magnetic field in electrical machine applications, it is vital to consider the effect of this external field on their AC magnetizing (ACMG) loss. It is well-known that external magnetic field decreases the current carrying capability of the wire. In real life, critical current density of HTS tapes is dependent to magnetic field but this dependency sometime was not considered in modeling stage in order to make it faster and simple. In this paper, the electromagnetic properties of HTS tapes for use in superconducting electric machines have been investigated with a particular focus on the ACMG loss of YBCO tapes. For this purpose, a two-dimensional finite element model has been implemented based on the H formulation in order to study the effect of dependency of critical current density to magnetic field on the variation of ACMG loss. The modeling results will be helpful for electrical machine designers to have a better understanding about this effect and have a more accurate estimate of ACMG loss in design stage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scaling ability of the counter-current flow limitation (CCFL) correlations for application to reactor thermal hydraulics

The limitation of gas-liquid counter-current flow is important for getting coolant to the core preventing heat-up. To illustrate the scaling dependence of counter-current flow in the downcomer, the upper core tie plate and the hot leg, some results are presented. Based on a derivation of the counter-current flow equations for vertical and horizontal flows, the scaling ability of existing correlations is shown for homogeneous vertical counter-current flow (Kutateladze-type equation) and separated horizontal flow in the hot leg during reflux-condenser conditions (Wallis equation). The large reactor scale heterogeneous counter-current flow in the downcomer and at the upper core tie-plate needed an extension of the Kutateladze-type equation. Finally, Bankoff suggested that for CCFL in perforated plates such as upper tie plate, a parameter that is a combination of actual length scale (Wallis parameter) and Laplace constant (Kutateladze parameter) will be required.

36 MATERIALS SCIENCE↗

Electron beam current in high power cylindrical diode

Intense electron beam generation studies were carried out in high power cylindrical diode to investigate the effect of the accelerating gap and diode voltage on the electron beam current. The diode voltage has been varied from 130 to 356 kV, whereas the current density has been varied from 87 to 391 A/cm{sup 2} with 100 ns pulse duration. The experimentally obtained electron beam current in the cylindrical diode has been compared with the Langmuir-Blodgett law. It was found that the diode current can be explained by a model of anode and cathode plasma expanding toward each other. However, the diode voltage and current do not follow the bipolar space-charge limited flow model. It was also found that initially only a part of the cathode take part in the emission process. The plasma expands at 4.2 cm/mus for 1.7 cm anode-cathode gap and the plasma velocity decreases for smaller gaps. The electrode plasma expansion velocity of the cylindrical diode is much smaller as compared with the planar diode for the same accelerating gap and diode voltage. Therefore, much higher voltage can be obtained for the cylindrical diodes as compared with the planar diodes for the same accelerating gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced diamagnetic perturbations and electric currents observed downstream of the high power helicon

The high power helicon (HPH) is capable of producing a high density plasma (10{sup 17}-10{sup 18} m{sup -3}) and directed ion energies greater than 20 eV that continue to increase tens of centimeters downstream of the thruster. In order to understand the coupling mechanism between the helicon antenna and the plasma outside the immediate source region, measurements were made in the plasma plume downstream from the thruster of the propagating wave magnetic field and the perturbation of the axial bulk field using a type 'R' helicon antenna. This magnetic field perturbation ({Delta}B) peaks at more than 15 G in strength downstream of the plasma source, and is 3-5 times larger than those previously reported from HPH. Taking the curl of this measured magnetic perturbation and assuming azimuthal symmetry suggests that this magnetic field is generated by a (predominantly) azimuthal current ring with a current density on the order of tens of kA m{sup -2}. At this current density the diamagnetic field is intense enough to cancel out the B{sub 0} axial magnetic field near the source region. The presence of the diamagnetic current is important as it demonstrates modification of the vacuum fields well beyond the source region and signifies the presence of a high density, collimated plasma stream. This diamagnetic current also modifies the propagation of the helicon wave, which facilitates a better understanding of coupling between the helicon wave and the resultant plasma acceleration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE ELECTRICAL CURRENT DENSITY VECTOR IN THE INNER PENUMBRA OF A SUNSPOT

We determine the entire electrical current density vector in a geometrical three-dimensional volume of the inner penumbra of a sunspot from an inversion of spectropolarimetric data obtained with Hinode/SP. Significant currents are seen to wrap around the hotter, more elevated regions with lower and more horizontal magnetic fields that harbor strong upflows and radial outflows (the intraspines). The horizontal component of the current density vector is 3-4 times larger than the vertical; nearly all previous studies only obtain the vertical component J{sub z} , thus strongly underestimating the current density. The current density J-vector and the magnetic field B-vector form an angle of about 20{sup 0}. The plasma {beta} at the 0 km level is larger than 1 in the intraspines and is one order of magnitude lower in the background component of the penumbra (spines). At the 200 km level, the plasma {beta} is below 0.3, nearly everywhere. The plasma {beta} surface as well as the surface optical depth unity is very corrugated. At the borders of intraspines and inside, B-vector is not force-free at deeper layers and nearly force-free at the top layers. The magnetic field of the spines is close to being potential everywhere. The dissipated ohmic energy is five orders of magnitudes smaller than the solar energy flux and thus negligible for the energy balance of the penumbra.

79 ASTRONOMY AND ASTROPHYSICS↗

Induced fermionic current in toroidally compactified spacetimes with applications to cylindrical and toroidal nanotubes

The vacuum expectation value of fermionic current is evaluated for a massive spinor field in spacetimes with an arbitrary number of toroidally compactified spatial dimensions in the presence of a constant gauge field. By using the Abel-Plana type summation formula and the zeta-function technique we present the fermionic current in two different forms. Nontrivial topology of the background spacetime leads to the Aharonov-Bohm effect for the fermionic current induced by the gauge field. The current is a periodic function of the magnetic flux with the period equal to the flux quantum. In the absence of gauge field it vanishes for special cases of untwisted and twisted fields. Applications of general formulas to Kaluza-Klein type models and to cylindrical and toroidal carbon nanotubes are given. In the absence of magnetic flux the total fermionic current in carbon nanotubes vanishes, due to the cancellation of contributions from two different sublattices of the hexagonal lattice of graphene.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attainment of the Pease-Braginskii current in an ultra-high-pressure discharge

Results are presented from experimental studies of the contraction of the channels of discharges in hydrogen and helium at current amplitudes of 0.5-1.6 MA and initial gas pressures of 5-35 MPa. The observed decrease in the brightness temperature of the discharge channel with increasing deposited energy is caused by the heating of the ambient gas. The channel contraction observed near the maximum of the discharge current is due to the attainment of the Pease-Braginskii critical current. Previously, it was shown that megampere discharges operate in a fully metallic plasma of the eroded electrodes. The theoretical value of the Pease-Braginskii current for discharges in vacuum is {approx}100-200 kA. The observed increase in the critical current to {approx}1 MA is attributed to the absorption of channel radiation in the dense ambient gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of a high-current relativistic electron beam

The dynamics of a high-current relativistic electron beam is studied experimentally and by numerical simulation. The beam is formed in a magnetically insulated diode with a transverse-blade explosive-emission cathode. It is found experimentally that the radius of a 500-keV beam with a current of 2 kA and duration of 500 ns decreases with time during the beam current pulse. The same effect was observed in numerical simulations. This effect is explained by a change in the shape of the cathode plasma during the current pulse, which, according to calculations, leads to a change in the beam parameters, such as the electron pitch angle and the spread over the longitudinal electron momentum. These parameters are hard to measure experimentally; however, the time evolution of the radial profile of the beam current density, which can be measured reliably, coincides with the simulation results. This allows one to expect that the behavior of the other beam parameters also agrees with numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the plasma current quench during disruptions in the National Spherical Torus Experiment

A detailed analysis of the plasma current quench in the National Spherical Torus Experiment [M.Ono, et al Nuclear Fusion 40, 557 (2000)] is presented. The fastest current quenches are fit better by a linear waveform than an exponential one. Area-normalized current quench times down to .4 msec/m2 have been observed, compared to the minimum of 1.7 msec/m2 recommendation based on conventional aspect ratio tokamaks; as noted in previous ITPA studies, the difference can be explained by the reduced self-inductance at low aspect ratio and high-elongation. The maximum instantaneous dIp/dt is often many times larger than the mean quench rate, and the plasma current before the disruption is often substantially less than the flat-top value. The poloidal field time-derivative during the disruption, which is directly responsible for driving eddy currents, has been recorded at various locations around the vessel. The Ip quench rate, plasma motion, and magnetic geometry all play important roles in determining the rate of poloidal field change.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fundamental Understanding of “Fresh” Lithium Nucleation and Growth in Sulfide-Based Anode-Free Solid-State Batteries: Effects of Substrate, Current Density, and Li + Supply

Understanding the electrochemical extraction and deposition of lithium (Li) from cathode is crucial for advancing anode-free solid-state batteries (AFSSBs). Herein, cryo-transmission electron microscopy (cryo-TEM) and electrochemical studies are employed to investigate how current collector surface properties, current densities, and cathode loadings influence the morphology of fresh electrochemically deposited Li and the electrochemical performance in sulfide-based AFSSBs. Cryo-TEM reveals that Cu current collectors induce irregular, dendritic Li deposits due to their lithiophobic nature and reactivity with Li 5.4 PS 4.4 Cl 1.6 (LPSC), while Ni and Au facilitate more uniform, planar-like Li growth. The morphology of the deposited Li also depends on current density: higher rates produce smaller, porous particles versus larger, denser deposits at lower rates. Importantly, for the first time, we discovered that low cathode loadings lead to poor cycling stability due to insufficient Li + supply for complete anode coverage, contrary to conventional solid-state batteries with preloaded Li metal anodes. This finding establishes a design principle where adequate cathode Li + reservoirs are essential for anode interface stability in AFSSBs. Overall, this work elucidates the interplayed effect of current collectors, current densities, and cathode loadings on Li morphology and cycle stability, offering fundamental insights into cathode-derived Li behavior and practical guidelines for optimizing AFSSBs performance through nucleation control and interface engineering.

25 ENERGY STORAGE↗

A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources

Corona discharge ionization sources are often used in ion mobility spectrometers (IMS) when a non-radioactive ion source with high ion currents is required. Typically, the corona discharge is followed by a reaction region where analyte ions are formed from the reactant ions. In this work, we present a simple yet sufficiently accurate model for predicting the ion current available at the end of this reaction region when operating at reduced pressure as in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) or most IMS-MS instruments. It yields excellent qualitative agreement with measurement results and is even able to calculate the ion current within an error of 15%. Additional interesting findings of this model are the ion current at the end of the reaction region being independent from the ion current generated by the corona discharge and the ion current in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) growing quadratically when scaling down the length of the reaction region. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient current induced in thin film diamonds by swift heavy ions

Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5 + and 45 MeV Si 7 + ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

36 MATERIALS SCIENCE↗

Structural and magnetic characterization of electro-crystallized magnetite nanoparticles under constant current

Graphical abstract: Structural and magnetic properties of electro-crystallized magnetite nanoparticles under constant current were studied. All samples were characterized using XRD, SEM, VSM, and Mössbauer spectrometry. - Highlights: • The effect of applied current on morphology and properties of Fe{sub 3}O{sub 4} is studied. • The particle size and morphology are controllable by adjusting the current. • The magnetization depends on particle size, type of surfactant and applied current. • The clear correlation between magnetization and the mean particle size is observed. - Abstract: The effect of applied current on the morphology, particle size, structure, and magnetic properties of magnetite nanoparticles prepared by electro-crystallization method was studied. The synthesis was performed in an electrochemical cell containing two iron electrodes and an aqueous solution of sodium sulfate, and either thiourea, sodium butanoate, or β-cyclodextrine as organic stabilizer. All the samples were characterized by XRD, SEM, VSM, and Mössbauer spectroscopy. X-ray diffraction patterns, clearly confirmed that all products have the cubic spinel Fe{sub 3}O{sub 4} crystal structure. Electron microscope images of the samples showed that their mean particle size is in the range 20–80 nm, and depends critically on the applied current and type of the organic additives. Specific magnetization of the samples at room temperature ranges from 60 to 90 A m{sup 2} kg{sup −1}, depending on the growth conditions. Room temperature Mössbauer spectra are typical of nonstoichiometric Fe{sub 3−δ}O{sub 4}, with a small excess of Fe{sup 3+}, 0.06 ≤ δ ≤ 0.17.

77 NANOSCIENCE AND NANOTECHNOLOGY↗