Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “commissioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of CLIQ on Training of HL-LHC Quadrupole Magnets

The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb 3 Sn magnets to be used in any large particle accelerator. At development stages, many Nb 3 Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based de-vices can affect Nb 3 Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. Here, the present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.

43 PARTICLE ACCELERATORS↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of a Superconducting “Direct Wind” R&D Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) [1] requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced.\r\nA value engineering effort is underway as part of the EIC Project to construct and test a Direct Wind magnet [2] (coil comprised of NbTi conductor deposited directly onto a support tube, in this instance tapered, and secured mechanically against Lorentz forces afterwards) to replace two Rutherford cable collared magnets. This magnet exceeds the combination of aperture, number of coil \r\nlayers, and magnetic field, as compared to existing accelerator and R&D Direct Wind magnets to date. Furthermore, construction has been completed using a newly commissioned winding machine, upgraded in anticipation of the upcoming EIC production coil fabrication. Design, analysis, construction issues, lessons learned and accomplishments to date shall be discussed, including the \r\nachieved corrections to multipoles made to successive coil layers based on warm magnetic measurements of preceding layers.

43 PARTICLE ACCELERATORS↗

Performance Testing and Assessment of Protection Scheme Using Real-Time Hardware-in-the-Loop and IEC 61850 Standard

The main challenge of the microgrid is to design a suitable protection scheme due to the complexity of the architecture of the microgrid. The importance of the proposed protection technique is threefold. First, it presents a co-simulation platform to integrate between a simulated model on power system computer aided design (PSCAD)/real time digital simulator computer aided design (RSCAD) software’s and physical devices schweitzer engineering laboratories (SEL) 421-7 relays to protect the microgrid that includes different resources connected based on inverter interface. Second, it presents a comprehensive hardware/software setup to test the protective relays in a closed loop system and shows how to configure the protective relay’s International Electrotechnical Commission 61850 communications. Third, IEEE 1588 standard is used to provide sub nanoseconds latency between the simulated model that emulated on real time digital simulator (RTDS) and the external devices. Also, the measurement signals are synchronized between RTDS and the external devices using giga-transceiver synchronization card (GTSYNC) interface card and SEL-2488 satellite-synchronized network clock. The results showed that the co-simulation infrastructure introduces a highly dependable design, analysis, and testing environment for cyber and physical data flow in the system. Besides that, the voltages at ac/dc sides and frequency at fault condition were maintained due to the energy storage device contributions at different modes of operation.

42 ENGINEERING↗

The Mu2e Crystal and SiPM Calorimeter: Construction Status

The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with an energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large-area UV-extended silicon photomultipliers (SiPMs). It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this article, we present the status of construction and the quality control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Comparison of CCM- and CRM-Based Boost Parallel Active Power Decoupler for PV Microinverter

Single-phase inverter or rectifier systems often make use of an active power decoupler (APD) to balance the mismatch between constant dc power and fluctuating ac power. This article deals with the comparison of continuous conduction mode (CCM) and critical conduction mode (CRM) operation-based design of a parallel boost-type APD for photovoltaic microinverter applications. From a design perspective, multiobjective analysis of efficiency, volume, and cost is explored within a decision space including planar inductors, gallium nitride based devices, film capacitors, switching frequency, and modulation (CCM vs. CRM). The theoretical study analyzes all possible design configurations within CCM and CRM and identifies Pareto-optimal designs, from which the selected CRM design can achieve reduced system volume and lower cost with the use of smaller inductor core, while operating with similar California Energy Commission efficiency drop as the selected CCM design. From a control perspective, a pulsewidth modulation based control strategy is proposed to implement closed-loop CRM modulation that does not rely on zero-crossing detection. Furthermore, closed-loop systems are designed for the optimal CCM and CRM realizations, and the final system characteristics are compared. Experimental results, obtained using two separate 40-V, 400-W hardware prototypes for CCM and CRM, are presented to verify the analyses.

42 ENGINEERING↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Assessment of Additively Manufactured Cooling Channel Performance for Helium-Cooled Blanket Concepts

Sufficient cooling of the blanket first wall remains a critical challenge for the design and deployment of fusion power plants. Helium has been targeted as a potential blanket coolant due to its inertness and low neutron interactivity, among other advantages. However, the low thermal mass of helium creates a need for heat transfer enhancements in coolant channels to provide adequate cooling to the blanket’s first wall. Toward this end, a series of ribbed flow channels of various rib cross sections and configurations has been produced via additive manufacturing (AM) to study the efficacy of AM for first wall heat transfer enhancement and the optimization of heat transfer geometries. Helium cooling performance is studied in AM test articles at 4 MPa operating pressure, Reynolds numbers up to 197 000, and outer surface heat fluxes up to 42 kW/m 2 in the recently commissioned helium flow loop experiment (HFLE). Preliminary results of this study are presented herein. Heat transfer performance of nominally smooth (i.e., featureless) AM channels is quantified via measured Nusselt numbers and friction factors and compared to off-the-shelf smooth pipe experiments. Results are compared to existing correlations and used to discuss the effects of the AM processes on thermal-hydraulic performance. It is seen that the inherent roughness of the AM channels leads to an increase in both heat transfer coefficient and pressure drop when compared to the conventional pipe. In conclusion, recommendations are made for future studies based on these findings and additional considerations for the deployment of AM blanket cooling components.

36 MATERIALS SCIENCE↗

The need for an integrated multi-OMICs approach in microbiome science in the food system

Microbiome science as an interdisciplinary research field has evolved rapidly over the past two decades, becoming a popular topic not only in the scientific community and among the general public, but also in the food industry due to the growing demand for microbiome-based technologies that provide added-value solutions. Microbiome research has expanded in the context of food systems, strongly driven by methodological advances in different -omics fields that leverage our understanding of microbial diversity and function. However, managing and integrating different complex -omics layers are still challenging. Within the Coordinated Support Action MicrobiomeSupport (https://www.microbiomesupport.eu/), a project supported by the European Commission, the workshop “Metagenomics, Metaproteomics and Metabolomics: the need for data integration in microbiome research” gathered 70 participants from different microbiome research fields relevant to food systems, to discuss challenges in microbiome research and to promote a switch from microbiome-based descriptive studies to functional studies, elucidating the biology and interactive roles of microbiomes in food systems. A combination of technologies is proposed. This will reduce the biases resulting from each individual technology and result in a more comprehensive view of the biological system as a whole. Although combinations of different datasets are still rare, advanced bioinformatics tools and artificial intelligence approaches can contribute to understanding, prediction, and management of the microbiome, thereby providing the basis for the improvement of food quality and safety.

60 APPLIED LIFE SCIENCES↗

Characterization of the Finite Element Computational Fluid Dynamics Capabilities in the Multiphysics Object Oriented Simulation Environment

We report the multiphysics object-oriented simulation environment (moose) is a code package that couples a variety of physics modules, allowing for highly accessible multiphysics simulations. The physics modules include a finite element Navier–Stokes (N–S) module that is designed to solve laminar fluid dynamics problems. The usage of this module in multiple recent studies coupled with the growing interest in moose for usage in nonlight water reactor safety studies by the Nuclear Regulatory Commission (NRC) prompted the authors to investigate the computational fluid dynamics capabilities of moose. A two-dimensional laminar flow past a circular cylinder scenario is simulated in the moose framework to investigate the effectiveness of the N–S module. Simulations assumed an unsteady laminar flow with a Reynolds number of 200. To verify the results from moose, similar simulations were conducted using the well-utilized simulation of turbulent flow in arbitrary regions—computational continuum mechanics C++ (star-ccm + ) finite volume code. Results from both codes are also compared to some results from literature. Velocity and pressure profiles of both transient simulations were compared. The numerical and input errors in moose are also visualized with contour plots to qualitatively understand the evolution of the errors across time and space. The comparisons between moose and star-ccm + showed nearly perfect agreement between the codes for velocity and pressure, especially after the development of the vortex street in later time-steps. The force coefficients showed excellent agreement after the development of the vortex street, but demonstrated notable discrepancies prior to the vortex street development, which is likely due to how each code simulated the approach to the vortex street in earlier time-steps.

97 MATHEMATICS AND COMPUTING↗

Review and Gap Analysis of Heliostat Components and Controls

This investigation provides a comprehensive literature review pertaining to heliostat components and controls as part of the U.S. Department of Energy (DOE), Heliostat Consortium (Heliocon) program. Here, this work presents a detailed assessment of subcomponents, controls and wireless communications elements that comprise various designs of helisotats within concentrating solar power (CSP) installations. Additionally, this work also provides the results of an industry survey, intended to compliment the literature discussion, to provide a gap analysis of the primary technology and cost areas that need to be addressed to help improved to spur concentrating solar power (CSP) bankability. Although the results of the study determined several key areas for development, three strategic areas identified were: (1) the use of advanced composite materials to replace a need for expensive steel within the structure and mirror substrate, (2) employment of closed-loop controls for automated calibration, reduction of commissioning time and O&M hours, reduction of drive requirements, as well as overall cost reduction, and (3) the need for more Heliostat-centric codes and standards to facilitate engineering confidence in the development of new features, cost reductions, or other design iterations to be seamlessly introduced without optical performance problems.

14 SOLAR ENERGY↗

Design, Analysis, and Experimental Testing of Hydrogen Lean Direct Injection Nozzles at Elevated Pressure

Abstract There are many challenges of commissioning a hydrogen combustor into future gas turbine engines; especially regarding achieving emissions goals. Previously, Escudero et al. and Tran et al. conducted a study to adapt the liquid fuel Lean Direct Injection (LDI) concept from Jet-A to gaseous natural gas-hydrogen blends and pure hydrogen [1], [2]. Experimental data was collected at atmospheric conditions using a Box Behnken design of experiments. The design of experiments suggested that biasing the air split in favor of the inner air circuit and increasing the swirl strength of this inner air passage resulted in improved NOx emissions, while the inverse was true for stability, which was quantified by studying the lean blowoff point (LBO) [1], [2]. The trends revealed by the original experiment [1], [2] provided a design direction for further iterations of the experimental hardware. The study presented herein describes the further investigation of such LDI injectors through experimental methods and computational fluid dynamic (CFD) simulations at atmospheric conditions, which were used to identify potential flow behaviors driving enhanced emissions performance. Further evaluation of select injectors from both studies was then conducted at elevated pressures up to 6 atmospheres. The results from both experiments are presented in this study, which include flame observations, emissions measurements, and operational challenges. NOx emissions results are reported on a volume basis in ppmvd corrected to 15% O2 and corrected for fuel. A predictive model for relating NOx emissions to test conditions at atmospheric conditions show high significance to adiabatic flame temperature while little to no significance to fuel composition for the best performing configurations. The results illustrate the connection between atmospheric testing and testing elevated pressures. The design direction indicated by the initial tests and CFD results in promising configurations for implementation into a Multi-point LDI array.

08 HYDROGEN↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Incorporating FLEX Strategies in Multi-Unit Probabilistic Risk Assessment

The catastrophic Fukushima nuclear accident reminded nuclear community about the possibilities of extreme accident scenarios, including those involving multiple reactor units on the same site. As the responses to the Fukushima accident, the nuclear power industry developed and implemented a series of strategies, including the Diverse and Flexible Coping Strategies (FLEX), to enhance the coping capacities of nuclear power plants (NPPs) under extreme accidents. This study intends to examine the impact of FLEX strategies on the risk from all the reactor units on the same NPP site, including risks from accidents involving a single unit and from accidents involving multiple units. The fundamental, methodological element of this study is Multi-Unit Probabilistic Risk Assessment (MUPRA), which requires a shift in Probabilistic Risk Assessment (PRA) from a “one-reactor-at-a-time” mindset to a “considering all reactors sharing a site as a unity” one. An integrated modeling approach for multi-unit event sequence development will be leveraged to develop MUPRA model and address the intra-unit and inter-unit dependencies. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), a PRA software developed and maintained by Idaho National Laboratory (INL) for the U.S. Nuclear Regulatory Commission (NRC), will serve as the platform for MUPRA modeling. This study selects Loss Of Offsite Power (LOOP) as a representative initiating event, which may occur on a generic two-unit NPP site and impacts both reactor units on the site. First, an MUPRA model, including multi-unit event trees, will be developed to obtain single-unit and multi-unit accident scenarios. Next, different FLEX strategies will be assumed, including FLEX equipment for a unit cannot be used for another unit, FLEX equipment for multiple units can be used in a cross-connected manner, etc. Lastly, the effectiveness of each postulated FLEX strategy will be evaluated by incorporating the corresponding FLEX equipment and deployment logic in the MUPRA model.

99 GENERAL AND MISCELLANEOUS↗

Structural Analysis Approach for the Defense Programs Package 3 (DPP-3)

The Pacific Northwest National Laboratory (PNNL) is the design authority for a new Type B hazardous materials transportation package designated as the Defense Programs Package 3 (DPP-3) for the U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA). The DPP-3 has been developed using similar materials and fabrication methods employed in previous U.S. Nuclear Regulatory Commission (NRC), DOE, and NNSA certified packages. The DPP-3 design criteria are derived from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), NNSA guidance and NRC regulatory guides in order to safely and securely transport a variety of payloads. Final regulatory approval by the NNSA will require physical testing to demonstrate that the containment vessel (CV) remains leaktight after enduring the entire regulatory testing sequence prescribed in Title 10 of the Code of Federal Regulations Part 71 (10 CFR 71). In order to gain confidence that the DPP-3 will remain leaktight after testing, the DPP-3 has been structurally analyzed using the Finite Element Analysis (FEA) software LS-DYNA. The FEA analyses serve two general purposes: first, they aid in design and development of the package, and second, they advise as to which drop orientations are expected to cause the most damage during regulatory testing. This paper will discuss how the design criteria are incorporated into analytical techniques needed to evaluate the FEA structural simulation results for 10 CFR 71 conditions to give confidence the DPP-3 testing campaign will be successful.

Sakalaukus Jr., Peter J.↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗