Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “commissioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Photoelectron spectroscopy and computational investigations of the electronic structures and noncovalent interactions of cyclodextrin-closo-dodecaborate anion complexes x-CD·B12X122- (x = a, ß, y; X = H, F)

We report a joint negative ion photoelectron spectroscopy (NIPES) and computational study on the electronic structures and noncovalent interactions of a series of cyclodextrin-closo-dodecaborate dianion complexes, ?-CD·B12X122- (? = a, ß, ?; X = H, F). The measured vertical / adiabatic detachment energies (VDEs / ADEs) are 1.15/0.93, 3.55/3.20, 3.90/3.60, and 3.85/3.60 eV for B12H122- and its a-, ß-, ?-CD complexes, respectively; while the corresponding values are 1.90/1.70, 4.00/3.60, 4.33/3.95, and 4.30/3.85 eV for the X = F case. These results show that the inclusion of B12X122- into the CD cavities greatly increase the electronic stability of the dianions. The effect of electronic stabilization for ß-CD is roughly the same as for ?-CD, both being considerably stronger than that for a-CD. Density functional theory (DFT) based geometry optimization reveals that B12X122- are inserted into CDs increasingly deeper from a-CD to ?-CD. The calculated VDEs and ADEs agree with the experiments well, particularly, reproducing the electron binding energy (EBE) trends. The molecular orbital analyses indicate that the most loosely bound photodetached electrons origin from the guest B12X122- moieties. In addition to a shift of all signals to larger EBE, significant changes in the signal patterns are observed. At low EBE, this is due to the splitting of highly degenerate B12X122- orbitals, while at high EBE, photodetachment from CD oxygens contributes to the new bands. The guest B12X122- and host CD nocovalent, size-specific interaction based on the independent gradient model (IGM) and energy decomposition analysis (EDA), is dominated by electrostatic interactions. The analysis further unravels unambiguiously the existence of dihydrogen bonding and how it affects the total energy that stabilizes the host-guest complexes of CDs·B12H122- compared to the general hydrogen bonding interaction in CDs·B12F122-. This work clearly exhibits strong influences on the electronic structures of dodecaborates upon clustering with CDs, with both size (a-, ß-, ?-) and molecular (X = H or F) specificities, thus providing critical molecular-level information on the cyclodextrin-closo-dodecaborate interactions of interest to medical applications, e.g. Boron neutron capature therapy. The NIPES experiments done at PNNL were supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Bioscience (X.-B.W.) and was performed at the EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. H.S. and Z.S. acknowledge the funding support of National Natural Science Foundation of China (Nos.11727810, 61720106009 and 21603074), the Science and Technology Commission of Shanghai Municipality (Nos. 19JC1412200), and the Program of Introducing Talents of Discipline to Universities 111 project (B12024). Z. L. thanks the China Scholarship Council (CSC) for financial support. We acknowledge the ECNU Multifunctional Platform for Innovation (001) and HPC Research Computing Team for providing computational and storage resources. J.W. acknowledges support from the Alexander von Humboldt foundation (Feodor Lynen Fellowship and Rückkehrerstipendium), a Freigeist fellowship of the Volkswagenfoundation and Prof. Vladimir A. Azov for helpful discussions.

Li, Zhipeng↗

Determinants for proton location and electron coupled proton transfer in hydrogen bonded pentafluorophenol-anion clusters

This work aims to reveal the determinant factors for proton locations and electron coupled proton transfer (ECPT) in biologically relevant hydrogen bonded systems. Pentafluorophenol-anion clusters [C6F5O-•H+•A-]- are chosen to model active sites of biological functions, with the anion A- being systematically varied to ensure the proton affinities (PAs) of the anions well cover the referenced PA of C6F5O- from being appreciably smaller, similar, and to significantly larger. Negative ion photoelectron spectroscopy of these clusters provides spectroscopic evidence showing that proton location in the anionic state is largely following the PA prediction, while ECPT is observed only for the clusters with the anion possessing the electron binding energy (EBE) significantly larger than that of the referenced C6F5O-. Theoretical calculations suggest these clusters are stabilized by forming single strong hydrogen bond between donor and acceptor, and the associated charge and MO analyses fully support the experimental observations. The current holistic cluster model study indicates that PA is the right determinant that can be used to predict the proton location and describe hydrogen bonding structures, while both PA and EBE of anionic groups play important roles in facilitating ECPT process. This work was supported by U.S. Department of Energy (DOE), Office of Basic Energy Sciences, Division of Chemical Science, Geosciences, and Biosciences (X.-B.W.), and performed using EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory, which is operated by Battelle Memorial Institute for the DOE. Part of this work was supported by the National Natural Science Foundation of China (No-11604046 for JZ; No. 11727810 for ZRS), as well as “Chenguang Program” by Shanghai Education Development Foundation, Shanghai Municipal Education Commission (No. 16CG38) and Natural Science Foundation of Shanghai (No. 16ZR1448100) (JZ).

Zhang, Jian↗

Feasibility of carbon foam-based sorbents for the abatement of gaseous mercury and iodine

The U.S. Department of Energy Hanford Site in Washington State is in the process of commissioning the Waste Treatment and Immobilization Plant to process a portion of the 54 million gallons of radioactive and chemical waste from cold war weapon production. Technologies for the capture of volatile species of concern are still being assessed, and new methods and materials are developed as operational and flowsheet mission risks are identified. One such area still being assessed is the abatement efficacy of the Carbon Adsorber units to retain gaseous mercury and 129 I released during processing. It is challenging to predict the mercury chemistry due to the variability of the feed, and different methods/materials are required for the capture of gaseous Hg 0 and Hg II compounds. In this study, the feasibility of using developmental carbon foam (CF) sorbents for the capture of iodine and mercury was assessed using static and dynamic flow testing and compared against a commercially available sorbent, BATII-37. Both CF and CF functionalized with bismuth particles (CF-Bi) chemisorbed iodine, and CF-Bi had similar mercury capture performance to BATII-37 in dynamic flow tests. While species loading concentrations were measurable, limitations in achieving a mass balance prevented a full evaluation of capture efficacy. Nonetheless, the results serve as an important first step in demonstrating the potential for simultaneous iodine and mercury capture.

Hanford site↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

First polarization study of the M87 jet and active galactic nuclei at submillimeter wavelengths with ALMA

We investigated the polarization and Faraday properties of Messier 87 (M87) and seven other radio-loud active galactic nuclei (AGNs) at λ0.87 mm (345 GHz) using the Atacama Large Millimeter/submillimeter Array (ALMA). Our goal was to characterize the linear polarization (LP) fractions, measure Faraday rotation measures (RMs), and examine the magnetic field structures in the emission regions of these AGNs. We conducted full-polarization observations as part of the ALMA Band 7 very long baseline interferometry (VLBI) commissioning during the April 2021 Event Horizon Telescope (EHT) campaign. We analyzed the LP fractions and RMs to assess the nature of Faraday screens and magnetic fields in the submillimeter emission regions. We find LP fractions between 1% and 17% and RMs exceeding 10 5 rad m −2 , which are 1–2 orders of magnitude higher than typically observed at longer wavelengths (λ>3 mm). This suggests denser Faraday screens or stronger magnetic fields. Additionally, we present the first submillimeter polarized images of the M87 jet and the observed AGNs, revealing RM gradients and sign reversals in the M87 jet indicative of a kiloparsec-scale helical magnetic field structure. Our results provide essential constraints for calibrating, analyzing, and interpreting VLBI data from the EHT at 345 GHz, representing a critical step toward submillimeter VLBI imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SECAR: A recoil separator for nuclear astrophysics

Proton-and alpha-capture reactions on unstable proton-rich nuclei power astrophysical explosions like novae and X-ray bursts. Direct measurements of these reactions are crucial for understanding the mechanisms behind these explosions and the nucleosynthesis at such sites. The recoil mass separator, SECAR (SEparator for CApture Reactions) at the National Superconducting Cyclotron Laboratory (NSCL) and the Facility for Rare Isotope Beams (FRIB), has been designed with the required sensitivity to study (p,γ) and (α,γ) reactions, directly at astrophysical energies in inverse kinematics, with radioactive beams of masses up to about A = 65. The complete SECAR system, including two Wien Filters for high mass resolution, has been installed at Michigan State University and is currently being commissioned. The present article introduces the SECAR concept, its scientific goals, and provides an update of the current status of the project.

Tsintari, P↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring Future Storage Options for ATLAS at the BNL/SDCC facility

The ATLAS experiment is expected to deliver an unprecedented amount of scientific data in the High Luminosity(HL-LHC) era. As the demand for disk storage capacity in ATLAS continues to rise steadily, the BNL Scientific Data and Computing Center (SDCC) faces challenges in terms of cost implications for maintaining multiple disk copies and adapting to the coming ATLAS storage requirements. To address these challenges, the SDCC Storage team has undertaken a thorough analysis of the ATLAS experiment's requirements, matching them to suitable storage options and strategies, and has explored alternatives to enhance or replace the current storage solution. This paper aims to present the main challenges encountered while supporting big data experiments such as ATLAS. We describe the experiment's specific requirements and priorities, particularly focusing on the critical storage system characteristics of the high-luminosity run and how the key storage components provided by the Storage team work together: the dCache disk storage system; its archival back-end, HPSS; and its OS-level backend Storage. Specifically, we investigate a novel approach to integrate Lustre and XRootD. In this setup, Lustre serves as backend storage and XRootD acts as an access layer frontend, supporting various grid access protocols. Additionally, we also describe the validation and commissioning tests, including the performance comparison between dCache and XRootd. Furthermore, we provide a performance and cost analysis comparing OpenZFS and LINUX MD RAID, evaluate different storage software stacks, and showcase stress tests conducted to validate Third Party Copy (TPC) functionality.

99 GENERAL AND MISCELLANEOUS↗

Repurposing of the Run 2 CMS High Level Trigger Infrastructure as a Cloud Resource for Offline Computing

The former CMS Run 2 High Level Trigger (HLT) farm is one of the largest contributors to CMS compute resources, providing about 25k job slots for offline computing. This CPU farm was initially employed as an opportunistic resource, exploited during inter-fill periods, in the LHC Run 2. Since then, it has become a nearly transparent extension of the CMS capacity at CERN, being located on-site at the LHC interaction point 5 (P5), where the CMS detector is installed. This resource has been configured to support the execution of critical CMS tasks, such as prompt detector data reconstruction. It can therefore be used in combination with the dedicated Tier 0 capacity at CERN, in order to process and absorb peaks in the stream of data coming from the CMS detector. The initial configuration for this resource, based on statically configured VMs, provided the required level of functionality. However, regular operations of this cluster revealed certain limitations compared to the resource provisioning and use model employed in the case of WLCG sites. A new configuration, based on a vacuum-like model, has been implemented for this resource in order to solve the detected shortcomings. This paper reports about this redeployment work on the permanent cloud for an enhanced support to CMS offline computing, comparing the former and new models’ respective functionalities, along with the commissioning effort for the new setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

sPHENIX Highlights: First Results from sPHENIX at RHIC

First results from the sPHENIX experiment on the π 0 v 2 and dE T =dη in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV using detector commissioning data during the RHIC 2023 Run are presented. These results are shown across a large centrality range, and compared to previous PHENIX and STAR results. These measurements demonstrate the sPHENIX capabilities towards accomplishing the sPHENIX jet physics program. From the ongoing RHIC 2024 Run, p + p collisions at $\sqrt{s}$ = 200 GeV, a first glimpse of the measurements K S 0 and Λ 0 obtained by the sPHENIX Time Projection Chamber (TPC) detector are shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

Preparation of the Multi-Site Data Processing at the Vera C. Rubin Observatory

The Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Camera is scheduled to start taking data in the summer of 2025. The Data Release Production will run the LSST Science Pipe software at data facilities in the US, France and the UK. The LSST Science Pipeline consists of complex directed acyclic graphs (DAGs) of tasks. Rubin will use the Production and Distributed Analysis (PanDA) workflow and workload management system to orchestrate this complex workflow and the distribution of workloads to the data facilities. When run end-to-end by a team of data production staff, this processing (the Science Pipelines, distributed by the workflow and workload management system) is referred to as a 'campaign'. This paper describes the central services and data facility specific services that support this multi-site data process model, including the service deployment infrastructure, the workload and workflow system, the Campaign Management tools, and connection to Rubin Data Management. This paper will also mention the experience of processing the Rubin Commissioning Camera data. All these are part of the effort to scale up the processing capabilities for the expected very large data volume from the LSST Camera.

Yang, Wei [SLAC]↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗

The design of a line velocity interferometer for any reflector for inertial confinement experiments on the Z-machine

A line VISAR (Velocity Interferometer System for Any Reflector) has been designed and commissioned at the Sandia National Laboratory’s Z-machine. The instrument consists of an F/2 collection system, beam transport, and an interferometer table that contains two Mach–Zehnder type interferometers and an eight channel Gated Optical Imaging (GOI) system. The VISAR probe laser operates at the 532 nm wavelength, and the GOI bandpass is 540–600 nm. The output of each interferometer is passed to an optical streak camera with four selectable sweep speeds. The system is designed with three interchangeable optics modules to select a full field of view of 1 mm, 2 mm, or 4 mm. The optical beam transport system connects the target image plane to the interferometers and the gated optical imagers. The target is integrated into a sacrificial final optics assembly that is integral to the transport beamline.

Datte, P.↗

Liquid-phase mega-electron-volt ultrafast electron diffraction

The conversion of light into usable chemical and mechanical energy is pivotal to several biological and chemical processes, many of which occur in solution. To understand the structure–function relationships mediating these processes, a technique with high spatial and temporal resolutions is required. Here, we report on the design and commissioning of a liquid-phase mega-electron-volt (MeV) ultrafast electron diffraction instrument for the study of structural dynamics in solution. Limitations posed by the shallow penetration depth of electrons and the resulting information loss due to multiple scattering and the technical challenge of delivering liquids to vacuum were overcome through the use of MeV electrons and a gas-accelerated thin liquid sheet jet. To demonstrate the capabilities of this instrument, the structure of water and its network were resolved up to the 3rd hydration shell with a spatial resolution of 0.6 Å; preliminary time-resolved experiments demonstrated a temporal resolution of 200 fs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrasonication-assisted trace amount solvent synthesis of Cs 4 PbBr 6 crystal with ultra-bright green light emission

Cs 4 PbBr 6 crystals have been synthesized by an ultrasonication-assisted trace amount polar solvent method. The prepared green Cs 4 PbBr 6 material was found to have high photoluminescence (PL) brightness and 10 ns PL lifetime. The prepared green light emitting device can achieve the maximum brightness of 3.8 × 10 9 cd/m 2 , which is nearly 100 times higher than a wick. The white light emitting device based on Cs 4 PbBr 6 crystals has better performance than commercial products, which can cover 32.3% of the color gamut and achieves 107.3% coverage for International Commission on Illumination (CIE)1931 and 84.8% coverage for CIE1976.

36 MATERIALS SCIENCE↗