Mechanical characterization of parts produced by ceramic on-demand extrusion process
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
High Cr 2 O 3 containing Monofrax ™ K‐3 is a robust refractory that is used in radioactive waste glass melters worldwide. Monofrax ™ K‐3 contains highly reduced phases. Conversely, many of the radioactive feeds being processed are highly oxidizing. The K‐3 refractory corrosion rates in oxidizing (high nitrate) feeds were ~1.8–2.8 times higher than the rates determined using reducing feeds. The corrosion product formed is a mixture of spinel and glass (slag) that can accumulate on the melter floor. A methodology to calculate the depth of slag deposits from refractory corrosion is presented and verified with slag measurements from the Defense Waste Processing Facility ( DWPF ) melter after it had processed oxidized feeds for 1.75 years. The calculations show that had the facility continued to process oxidized feeds the melter lifetime (based on when the deposits could have reached and blocked the pour spout riser) would have been ~4.5 years. The DWPF changed to a reducing flow sheet after ~3 years of operation. The lifetimes of Melter #1 and Melter #2, assuming a failure due to pour spout blockage, are calculated as 7.7–12 years based on corrosion rates measured with reducing feeds. Lifetimes of 9 and >11 years have actually been achieved.
High Cr 2 O 3 containing Monofrax ™ K‐3 is a robust refractory that is used in the fiberglass industry and used in radioactive waste glass melters worldwide. Monofrax ™ K‐3 is tolerant of transition metal oxides but contains highly reduced solid solutions of spinels, that is, (Mg,Fe 2+ )(Al,Cr) 2 O 3 . Conversely, many of the waste feeds being processed are highly oxidizing. The K‐3 refractory corrosion was tested in sealed crucibles starting with slurried melter feed instead of prereacted glass called for by ASTM C621. Testing the refractory coupon during the feed‐to‐glass conversion exposes the refractory to the oxidizing and reducing species being released during vitrification, for example, NO 3 − , NO 2 − , CO 2 , CO , O 2 . Corrosion rates measured in highly oxidizing (high nitrate) feeds were ~1.8–2.8 times higher than those determined using prereacted glass or reduced feeds. Confirmatory corrosion rates were measured on Monofrax ™ K‐3 coupons immersed in oxidizing feed in a 1/100th‐scale HLW pilot‐scale melter. Corrosion is heterogeneous or incongruent as Ni and Fe in the waste glass exchange with Mg and Al in the refractory. An insoluble NiFe 2 O 4 spinel corrosion product is formed that can build up a protective layer along the refractory walls or spall and settle to the melter floor depending on melt pool convection/agitation.
Abstract Not Provided
Not provided.
Not provided.
Not provided.
Explore the source record for details and available documents.
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it - this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacelle through a series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.
Abstract not provided.
Presentation from ASME Turbo Expo 2021
Conference paper for the ASME 2022 Turbomachinery Technical Conference & ExpositionJune 13-17, 2022, Rotterdam, The Netherlands<br>
Polymeric materials are commonplace in the natural gas infrastructure as distribution pipes, coatings, seals, and gaskets. Under the auspices of the U.S. Department of Energy HyBlend program, one of the means to reduce greenhouse gas emissions is with replacing natural gas, either partially or completely, with hydrogen. This approach makes it imperative that we conduct near-term and long-term materials compatibility research in these relevant environments. Insights into the effects of hydrogen and hydrogen gas blends on polymer integrity can be gained through both ex-situ and in-situ analytical methods. Our work represented here highlights a study of the behavior of pipeline polyethylene (PE) materials, including HDPE (Dow 2490 and GDB50) and MDPE (Ineos and legacy Dupont Aldyl A), when exposed to hydrogen by means of in-situ X-ray scattering and ex-situ Raman spectroscopy techniques. Samples were tested in ex-situ hydrogen and argon gas environments and in-situ hydrogen environments to identify differences due to permeation and solubility of these gases. These methods complemented each other because Raman spectroscopy could capture permanent effects after materials were removed from gaseous environments, and in-situ X-ray scattering analysis collected real-time data to elucidate the impact of the gas environment on polymer microstructure. Data collected revealed that the aforementioned polymers did not show significant changes in crystallinity and microstructure under the exposure conditions tested. Our findings from these studies will help establish real-time effects caused by hydrogen gas transport through pipeline polyethylenes by way of its influence on polymer structure and chemistry, which is directly related to pipeline mechanical strength and longevity of service.
A study is reported comparing the electrical and optical properties of CdTe solar cells, prepared using CdS and CdSe buffer layers, to investigate defects in the bulk and interface, carrier transport, and recombination. Temperature dependent capacitance-voltage measurement and admittance spectroscopy were used to extract carrier concentration, resistivity, charge carrier mobility, and their temperature dependence. We identify the presence of two defect signatures corresponding to carrier freeze-out and the formation of a Schottky back-contact barrier. The back-contact barrier height (≈ 300 meV) extracted from the temperature dependent current density-voltage (JVT) experiment was confirmed by conventional admittance spectroscopy. The activation energies of mobility (resistivity) are 101.2 ± 2.5 meV (92.6 ± 2.3 meV) and 84.7 ± 2.7 meV (77.6 ± 4.5 meV) for CdS and CdSe buffer layers, respectively. Intensity dependent photoluminescence analysis demonstrates that the CdSe/CdTe device exhibits lower radiative efficiency than the CdS/CdTe device. This confirms the presence of higher defects in CdSe/CdTe device corroborated by temperature-dependent V OC analysis. Here, the comparative electrical and optical analysis provides insight to improving the performance of CdTe solar cell device by selenization.
The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.
Abstract not provided
Explore the source record for details and available documents.