Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

We evaluated thermal noise (Brownian motion) in a rigid reference cavity used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with t.he direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency- reference cavity of order 1 Hz/square root Hz(0.01 Hz/square root Hz) at 10 mHz (100 Hz) at room temperature. This level coincides with the world-highest level stabilization results.

Numata, Kenji↗

Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

We evaluated thermal noise (Brownian motion) in a rigid reference cavity Used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with the direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency-reference cavity of order 1 Hz/rtHz at 10mHz at room temperature. This level coincides with the world-highest level stabilization results.

Numata, Kenji↗

Mirror Birefringence in a Fabry-Perot Cavity and the Detection of Vacuum Birefringence in a Magnetic Field

We discuss the effect of mirror birefringence in two optical schemes designed to detect the quantum-electrodynamics (QED) predictions of vacuum birefringence under the influence of a strong magnetic field, B. Both schemes make use of a high finesse Fabry-Perot cavity (F-P) to increase the average path length of the light in the magnetic field. The first scheme, which we called the frequency scheme, is based on measurement of the beat frequency of two orthogonal polarized laser beams in the cavity. We show that mirror birefringence contributes to the detection uncertainties in first order, resulting in a high susceptibility to small thermal disturbances. We estimate that an unreasonably high thermal stability of ~10-9 K is required to resolve the effect to 0.1%. In the second scheme, which we called the polarization rotation scheme, laser polarized at 45 relative to the B field is injected into the cavity.

Vacuum Birefringence↗

Semi-monolithic cavity for external resonant frequency doubling and method of performing the same

The fabrication of an optical cavity for use in a laser, in a frequency doubling external cavity, or any other type of nonlinear optical device, can be simplified by providing the nonlinear crystal in combination with a surrounding glass having an index of refraction substantially equal to that of the nonlinear crystal. The closed optical path in this cavity is formed in the surrounding glass and through the nonlinear crystal which lies in one of the optical segments of the light path. The light is transmitted through interfaces between the surrounding glass in the nonlinear crystal through interfaces which are formed at the Brewster-angle to minimize or eliminate reflection.

Hemmati, Hamid↗

Discrete wavelength-locked external cavity laser

An external cavity laser (and method of generating laser light) comprising: a laser light source; means for collimating light output by the laser light source; a diffraction grating receiving collimated light; a cavity feedback mirror reflecting light received from the diffraction grating back to the diffraction grating; and means for reliably tuning the external cavity laser to discrete wavelengths.

Pilgrim, Jeffrey S.↗

Correlations for Boundary-Layer Transition on Mars Science Laboratory Entry Vehicle Due to Heat-Shield Cavities

The influence of cavities (for attachment bolts) on the heat-shield of the proposed Mars Science Laboratory entry vehicle has been investigated experimentally and computationally in order to develop a criterion for assessing whether the boundary layer becomes turbulent downstream of the cavity. Wind tunnel tests were conducted on the 70-deg sphere-cone vehicle geometry with various cavity sizes and locations in order to assess their influence on convective heating and boundary layer transition. Heat-transfer coefficients and boundary-layer states (laminar, transitional, or turbulent) were determined using global phosphor thermography.

Hollis, Brian R.↗

Blackbody Cavity for Calibrations at 200 to 273 K

A laboratory blackbody cavity has been designed and built for calibrating infrared radiometers used to measure radiant temperatures in the range from about 200 to about 273 K. In this below-room-temperature range, scattering of background infrared radiation from room-temperature surfaces could, potentially, contribute significantly to the spectral radiance of the blackbody cavity, thereby contributing a significant error to the radiant temperature used as the calibration value. The present blackbody cavity is of an established type in which multiple reflections from a combination of conical and cylindrical black-coated walls are exploited to obtain an effective emissivity greater than the emissivity value of the coating material on a flat exposed surface.

Howell, Dane↗

Thermal Protection System Cavity Heating for Simplified and Actual Geometries Using Computational Fluid Dynamics Simulations with Unstructured Grids

Thermal Protection System (TPS) Cavity Heating is predicted using Computational Fluid Dynamics (CFD) on unstructured grids for both simplified cavities and actual cavity geometries. Validation was performed using comparisons to wind tunnel experimental results and CFD predictions using structured grids. Full-scale predictions were made for simplified and actual geometry configurations on the Space Shuttle Orbiter in a mission support timeframe.

McCloud, Peter L.↗

Hollow waveguide cavity ringdown spectroscopy

Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

Dreyer, Chris↗

Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter

The 3D Automated Thermal Tool for Damaged Acreage Tile Math Model builder was developed to perform quickly and accurately 3D thermal analyses on damaged lower surface acreage tiles and structures beneath the damaged locations on a Space Shuttle Orbiter. The 3D model builder created both TRASYS geometric math models (GMMs) and SINDA thermal math models (TMMs) to simulate an idealized damaged cavity in the damaged tile(s). The GMMs are processed in TRASYS to generate radiation conductors between the surfaces in the cavity. The radiation conductors are inserted into the TMMs, which are processed in SINDA to generate temperature histories for all of the nodes on each layer of the TMM. The invention allows a thermal analyst to create quickly and accurately a 3D model of a damaged lower surface tile on the orbiter. The 3D model builder can generate a GMM and the correspond ing TMM in one or two minutes, with the damaged cavity included in the tile material. A separate program creates a configuration file, which would take a couple of minutes to edit. This configuration file is read by the model builder program to determine the location of the damage, the correct tile type, tile thickness, structure thickness, and SIP thickness of the damage, so that the model builder program can build an accurate model at the specified location. Once the models are built, they are processed by the TRASYS and SINDA.

Belknap, Shannon↗

Temperature Sensitivity of an Atomic Vapor Cell-Based Dispersion-Enhanced Optical Cavity

Enhancement of the response of an optical cavity to a change in optical path length, through the use of an intracavity fast-light medium, has previously been demonstrated experimentally and described theoretically for an atomic vapor cell as the intracavity resonant absorber. This phenomenon may be used to enhance both the scale factor and sensitivity of an optical cavity mode to the change in path length, e.g. in gyroscopic applications. We study the temperature sensitivity of the on-resonant scale factor enhancement, S(sub o), due to the thermal sensitivity of the lower-level atom density in an atomic vapor cell, specifically for the case of the Rb-87 D(sub 2) transition. A semi-empirical model of the temperature-dependence of the absorption profile, characterized by two parameters, a(sub o)(T) and gamma(sub a)(T) allows the temperature-dependence of the cavity response, S(sub o)(T) and dS(sub o)/dT to be predicted over a range of temperature. We compare the predictions to experiment. Our model will be useful in determining the useful range for S(sub o), given the practical constraints on temperature stability for an atomic vapor cell.

Myneni, K.↗

Meander-Like Shape Optimization of the Stator-Rotor Platform Cavity

Recent progress in additive manufacturing has enabled opportunities to explore novel stator rim geometries which can be implemented to improve cooling strategies in turbomachinery. This paper presents a simplified stationary geometry optimization strategy to produce enhanced stator-rotor cavity sealing and highlights main driving mechanisms.The stator and rotor rims were designed using a design strategy based on inspiration from the meandering of rivers. A minimum thickness of 2 millimeters was maintained throughout the cavity to ensure a practical implementation. The computational domain comprised of the stator outlet, hub disk leakage cavity, and rotor platform was meshed using NUMECA Int. package, Hexpress. The numerical analysis required 3D Unsteady Reynolds Average Navier-Stokes to replicate vorticial structures using Ansys Fluent. The operating conditions were representative of engine-like conditions, exploring a wide range of mass flow ratios from 1 to 3 percent. The optimization yielded designs that provide 30 percent reduction in rear platform temperature while minimizing coolant mass flow. The applicability of the design was compared against 3D sector in both stationary and in rotation.

Shape Optimization↗

Material Response Modeling of MMOD Cavities

An arc-jet test campaign is used as a baseline to computationally model the flow and material response of cavities. A parametric study is designed around the baseline to study geometric effects on parameters of interest. The US3D flow solver is used to simulate the arc-jet flow in the Aerodynamic Heating Facility (AHF) at NASA Ames and generate the heating environment over material samples with cavities. The Icarus material response code is then used to simulate the multi-dimensional heating under the above conditions of samples of FiberForm with cavities.

EDL↗

A Portable Nitrogen Dioxide Instrument Using Cavity-Enhanced Absorption Spectroscopy

The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent, broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ~520 m. Our precision was measured as 94 pptv (1 s). To date, we have flown this instrument on 3 balloon and 1 UAV test flights. This instrument records data to an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.

TROPOMI↗

STUDY OF HARMONIC CRAB CAVITY IN EIC BEAM-BEAM SIMULATIONS

In the Electron-Ion Collider (EIC) design, crab cavities are adopted to compensate the geometric luminosity loss from the crossing angle. From previous studies, higher-order synchro-betatron resonances are excited since the hadron beam is long and the crossing angle is large. To reduce the luminosity degradation rate, different combinations of harmonic crab cavities are studied with both weak-strong and strong-strong simulation methods. The frequency map analysis (FMA) is also used for comparison. This study helps determine the crab cavity parameters for the future EIC.

43 PARTICLE ACCELERATORS↗

The Role of Oxygen Concentration in Enabling High Gradients in Niobium SRF Cavities

We studied the role of O concentration with depth in the performance of Nb SRF cavities. An ensemble of electropolished 1.3 GHz cavities, which initially showed high field Q-slope (HFQS), was subjected to sequential testing and treatment with in-situ low temperature baking at various temperatures. We find that increasing the bake duration causes (i) an increase in the onset of HFQS until it is absent up to quench (ii) a non-monotonic relationship with the quench field (iii) an evolution of the RBCS toward a non-equilibrium behavior that drives anti-Q slope. Our data is qualitatively explained by assuming an O diffusion model and suggests that the mitigation of HFQS that arises from 120 C in-situ LTB is mediated by the diffusion of O from the native oxide which prevents the precipitation of proximity-coupled Nb nano-hydrides, in turn enabling higher quench fields. The decrease in quench field for cavities in which O has been diffused >90 nm from the RF surface may be due to a reduction of the field limit in the SS bilayer structure. We also suggest that the evolution of the RBCS occurs due to the absence of proximity coupled inclusions, bringing about non-equilibrium effects.

Bafia, D.↗

Qualifying AL-800 Garnet For The Fermilab Booster Perpendicular Biased 2nd Harmonic RF Cavity

Al-800 garnet was evaluated for the perpendicular biased 2nd harmonic cavity for the Fermilab Booster accelerator. A test apparatus was designed to evaluate the magnetic permeability and batch consistency of small witness samples of Al-800. Fully assembled AL-800 garnet rings were tested on the garnet ring test stand to measure the resonant frequency and quality factor of each ring. The garnet witness samples and assembled garnet rings showed acceptable consistency within the parameters set by the cavity design team. Based on the test results, AL-800 garnet was deemed suitable for use in the perpendicular biased 2nd harmonic cavity.

Kuharik, John C.↗

Searches for New Particles, Dark Matter, and Gravitational Waves with SRF Cavities

This is a Snowmass white paper on the utility of existing and future superconducting cavities to probe fundamental physics. Superconducting radio frequency (SRF) cavity technology has seen tremendous progress in the past decades, as a tool for accelerator science. With advances spear-headed by the SQMS center at Fermilab, they are now being brought to the quantum regime becoming a tool in quantum science thanks to the high degree of coherence. The same high quality factor can be leveraged in the search for new physics, including searches for new particles, dark matter, including the QCD axion, and gravitational waves. We survey some of the physics opportunities and the required directions of R&D. Given the already demonstrated integration of SRF cavities in large accelerator systems, this R&D may enable larger scale searches by dedicated experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗