Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Improvements in Modeling Thruster Plume Erosion Damage to Spacecraft Surfaces

Spacecraft bipropellant thrusters impact spacecraft surfaces with high speed droplets of unburned and partially burned propellant. These impacts can produce erosion damage to optically sensitive hardware and systems (e.g., windows, camera lenses, solar cells and protective coatings). On the International Space Station (ISS), operational constraints are levied on the position and orientation of the solar arrays to mitigate erosion effects during thruster operations. In 2007, the ISS Program requested evaluation of erosion constraint relief to alleviate operational impacts due to an impaired Solar Alpha Rotary Joint (SARJ). Boeing Space Environments initiated an activity to identify and remove sources of conservatism in the plume induced erosion model to support an expanded range of acceptable solar array positions  The original plume erosion model over-predicted plume erosion and was adjusted to better correlate with flight experiment results. This paper discusses findings from flight experiments and the methodology employed in modifying the original plume erosion model for better correlation of predictions with flight experiment data. The updated model has been successful employed in reducing conservatism and allowing for enhanced flexibility in ISS solar array operations.

Soares, Carlos↗

MPCV Exercise Operational Volume Analysis

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

mathematical models↗

The Hayabusa2 Sample Return Mission and Its Small Carry-On Impactor Experiment

On December 3, 2014 the Hayabusa2 Spacecraft was launched by JAXA to investigate and return samples from carbonaceous Asteroid (162173) Ryugu. The spacecraft's payload contains several remote sensing instruments that are designed to characterize the asteroid's surface and to help identify scientifically interesting locations from which samples can be obtained safely. The data collected by these instruments will also help place any obtained samples in context with respect to the global characteristics of Ryugu. In addition to the suite of remote sensing instruments and the sampling device, Hayabusa2 also includes a small carry-on impactor (SCI) payload experiment, which is designed to impact the surface of the asteroid and excavate fresh material for subsequent collection. The SCI consists of a 30 cm diameter 2 kg copper disk that is accelerated by an explosive charge into the surface of Ryugu at approximately 2 km/s. The resultant crater formed during this experiment is estimated to be approximately between 2 - 10 meters in diameter with an ejecta blanket extending to 10 - 100 meters on the asteroid. Hayabusa2 will not be able to observe the impact experiment directly due to considerations of spacecraft safety since there is some risk of collisions with debris from the explosion and ejecta from the crater. However, prior to moving safely away, the spacecraft will deploy a small imaging system called Deployable Camera 3 (DCAM3). DCAM3 will detach from Hayabusa2 just before the detonation of the SCI and will image the moment of impact, crater formation, and ejecta propagation. These data will be transmitted to Hayabusa2 and will help constrain the near-surface properties of Ryugu and also impact scaling laws for small bodies in low gravity environments. These data could also be useful for gaining insights into determining asteroid physical properties from higher velocity impact events (e.g., DART and HERA data of Didymos).

Abell, Paul A.↗

WebGeocalc and Cosmographia: Modern Tools to Access OPS SPICE Data

For more than two decades navigation and other ancillary data from most US and international planetary science missions have been packaged using "SPICE" (Spacecraft, Planet, Instrument, Camera-matrix, Events) system data files (a.k.a. SPICE kernels) and, in conjunction with SPICE Toolkit software used by scientists and engineers to compute observation geometry in various ground system tools ranging from mission planning and analysis applications to data production pipelines to science analysis tools. The traditional way for accessing SPICE data is by downloading necessary SPICE kernels to a user’s workstation, installing the SPICE Toolkit software available from NAIF, and writing an application calling APIs from the SPICE Toolkit library to compute numeric geometric parameters of interest. While this approach did and still does provide the greatest flexibility in implementing geometric computations of interest, it proved to be complicated for users with little programming abilities, required data to be always copied to the users’ workstations, and lacked any out-of-the-box visualization capabilities. To address these shortcomings NAIF developed the WebGeocalc (WGC) tool and extended the publicly available Cosmographia program to use SPICE. Employing these two new tools in mission operations enables easier access to SPICE computations and SPICE-based visualizations for a wider variety of mission personnel.

Semenov, Boris V.↗

10-kHz PLIF Thermometry for a Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar laser-induced fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to285.62 nm and 285.67 nm to excite the Q2(12) and P1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

10-kHz PLIF Thermometry for Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar Laser-Induced Fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 nm and 285.67 nm to excite the Q2(12) andP1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

Mars Sample Return Earth Entry System Helicopter Drop Test Reconstruction

The Mars Sample Return campaign conducted four successful helicopter drop tests of the Earth Entry System at the Utah Test and Training Range on October, 2023. The tests acquired data for the 52.5 deg sphere cone geometry that can be used to develop models for the terminal descent aerodynamics and flight dynamics used to model ground impact conditions. The acquired test data included both sensor data outputs from an on-board inertial measurement unit, global positioning system, and video cameras as well as atmospheric measurements from weather balloons. This data was processed using a Kalman filter/smoother to reconstruct the capsule’s trajectory and aerodynamics. An equation-error method was used to reconcile the aerodynamics by solving for a set of dispersions in the aerodynamic database that form a best-fit to the reconstructed aerodynamics. The reconstructed trajectories were compared with flight simulations generated using Program to Optimize Simulated Trajectories II. The results indicate that the simulation underpredicted the vehicle oscillation amplitudes. The reconstruction exhibits a persistent low-amplitude oscillation that does not damp out as predicted.

Chris D Karlgaard↗

Mars Sample Return Earth Entry System Helicopter Drop Test Reconstruction

The Mars Sample Return campaign conducted four successful helicopter drop tests of the Earth Entry System at the Utah Test and Training Range on October, 2023. The tests acquired data for the 52.5 deg sphere cone geometry that can be used to develop models for the terminal descent aerodynamics and flight dynamics used to model ground impact conditions. The acquired test data included both sensor data outputs from an on-board inertial measurement unit, global positioning system, and video cameras as well as atmospheric measurements from weather balloons. This data was processed using a Kalman filter/smoother to reconstruct the capsule’s trajectory and aerodynamics. An equation-error method was used to reconcile the aerodynamics by solving for a set of dispersions in the aerodynamic database that form a best-fit to the reconstructed aerodynamics. The reconstructed trajectories were compared with flight simulations generated using Program to Optimize Simulated Trajectories II. The results indicate that the simulation underpredicted the vehicle oscillation amplitudes. The reconstruction exhibits a persistent low-amplitude oscillation that does not damp out as predicted.

Chris D Karlgaard↗

Method and system for automated plant surveillance and manipulation

A method and a system for automated plant surveillance and manipulation are provided. Pursuant to the method and the system, images of target plants are obtained through a machine vision system having multiple cameras. The obtained images of the target plants are processed to determine tissue candidates of the target plants and to determine a position and an orientation of each tissue candidate. A tool is manipulated, based on the position and the orientation of each tissue candidate, to excise each tissue candidate to obtain tissue samples. The tissue samples are transported for subsequently manipulation including live processing of the tissue samples or destructive processing of the tissue samples.

Kalluri, Udaya C.↗

Low-light-level integrating video system

System consists of television camera using 25 mm SEC vidicon, low dispersion spectrograph, and digital video image system used for buffer storage of video data during tube readout scanning. Six-bit ADC converts video to digital data which are stored on magnetic tape for future evaluation.

Duncan, B. J.↗

Development of robots and application to industrial processes

An algorithm is presented for using a robot system with a single camera to position in three-dimensional space a slender object for insertion into a hole; for example, an electrical pin-type termination into a connector hole. The algorithm relies on a control-configured end effector to achieve the required horizontal translations and rotational motion, and it does not require camera calibration. A force sensor in each fingertip is integrated with the vision system to allow the robot to teach itself new reference points when different connectors and pins are used. Variability in the grasped orientation and position of the pin can be accomodated with the sensor system. Performance tests show that the system is feasible. More work is needed to determine more precisely the effects of lighting levels and lighting direction.

Palm, W. J.↗

Video guidance sensor

A Martin-Marietta study comparing the application of laser, video, or RF sensors was conducted in 1982. The study concluded that video was the most attractive sensor (the video also could be used for operator monitoring). The Retro-Reflector field Tracker from the Solar Array Flight Experiment was chosen as a 'first generation' sensor and integrated with guidance algorithms for evaluation on the air-bearing vehicle. Results indicated that this sensor was not applicable for the noise environment posed by the multi-layer insulation used on most spacecraft. A 'second generation' sensor was developed to be used with a modified RMS target. This sensor utilized two sets of laser diodes to acquire three optically filtered targets. The targets were illuminated first with a 780 nanometer diode, followed by illumination with a 830 nm diode. The second digitized picture was subtracted from the first to get a low-noise image. The centroids of the retroreflectors were used then to uniquely derive target attitude and range. The sensor presently operates to 80 feet and within +/- 40 degrees in pitch and yaw. Sensor operability is a concern if the sun is within a +/- 40 degree cone angle to the target. The present sensor performance characteristics are less than 1 percent range error and less than 1 degree angle error. Future sensor development is anticipated to extend the operating range to 150 feet and reduce the cone angle of sensor inoperability to within +/- 10 degrees of direct sunlight. Performance improvements also are anticipated. TRW currently is developing a system that utilizes dual cameras with simultaneous diode illumination. Although further development is being pursued, the basic system has proven sound, and the sensor is essentially ready for application.

Howard, Richard↗

Utilizing Commercial Hardware and Open Source Computer Vision Software to Perform Motion Capture for Reduced Gravity Flight

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts. To perform validation of these models and to support the Advanced Exercise Concepts Project, several candidate devices have been flown onboard NASAs Reduced Gravity Aircraft. In terrestrial laboratories, researchers typically have available to them motion capture systems for the measurement of subject kinematics. Onboard the parabolic flight aircraft it is not practical to utilize the traditional motion capture systems due to the large working volume they require and their relatively high replacement cost if damaged. To support measuring kinematics on board parabolic aircraft, a motion capture system is being developed utilizing open source computer vision code with commercial off the shelf (COTS) video camera hardware. While the systems accuracy is lower than lab setups, it provides a means to produce quantitative comparison motion capture kinematic data. Additionally, data such as required exercise volume for small spaces such as the Orion capsule can be determined. METHODS: OpenCV is an open source computer vision library that provides the ability to perform multi-camera 3 dimensional reconstruction. Utilizing OpenCV, via the Python programming language, a set of tools has been developed to perform motion capture in confined spaces using commercial cameras. Four Sony Video Cameras were intrinsically calibrated prior to flight. Intrinsic calibration provides a set of camera specific parameters to remove geometric distortion of the lens and sensor (specific to each individual camera). A set of high contrast markers were placed on the exercising subject (safety also necessitated that they be soft in case they become detached during parabolic flight); small yarn balls were used. Extrinsic calibration, the determination of camera location and orientation parameters, is performed using fixed landmark markers shared by the camera scenes. Additionally a wand calibration, the sweeping of the camera scenes simultaneously, was also performed. Techniques have been developed to perform intrinsic calibration, extrinsic calibration, isolation of the markers in the scene, calculation of marker 2D centroids, and 3D reconstruction from multiple cameras. These methods have been tested in the laboratory side-by-side comparison to a traditional motion capture system and also on a parabolic flight.

Biodynamics↗

Development of a model of machine hand eye coordination and program specifications for a topological machine vision system

A unified approach to computer vision and manipulation is developed which is called choreographic vision. In the model, objects to be viewed by a projected robot in the Viking missions to Mars are seen as objects to be manipulated within choreographic contexts controlled by a multimoded remote, supervisory control system on Earth. A new theory of context relations is introduced as a basis for choreographic programming languages. A topological vision model is developed for recognizing objects by shape and contour. This model is integrated with a projected vision system consisting of a multiaperture image dissector TV camera and a ranging laser system. System program specifications integrate eye-hand coordination and topological vision functions and an aerospace multiprocessor implementation is described.

Source record↗

Air jet levitation furnace system for observing glass microspheres during heating and melting

A collimated hole structure air jet levitation system has been developed which can be used to levitate hollow glass microspheres used in inertial confinement fusion studies. An ellipsoidal furnace has been added to the system to provide a heating source. A video camera and a 16 mm movie camera connected to a microsphere system provide real time observation as well as permanent documentation of the experiments. Microspheres have been levitated at temperatures over 1400 C for over 10 minutes at a time.

Ethridge, E. C.↗

Testing of a Methane Cryogenic Heat Pipe with a Liquid Trap Turn-Off Feature for use on Space Interferometer Mission (SIM)

Camera cooling for SIM presents three thermal control challenges; stable operation at 163K (110 C), decontamination heating to +20 C, and a long span from the cameras to the radiator. A novel cryogenic cooling system based on a methane heat pipe meets these challenges. The SIM thermal team, with the help of heat pipe vendor ATK, designed and tested a complete, low temperature, cooling system. The system accommodates the two SIM cameras with a double-ended conduction bar, a single methane heat pipe, independent turn-off devices, and a flight-like radiator. The turn ]off devices consist of a liquid trap, for removing the methane from the pipe, and an electrical heater to raise the methane temperature above the critical point thus preventing two-phase operation. This is the first time a cryogenic heat pipe has been tested at JPL and is also the first heat pipe to incorporate the turn-off features. Operation at 163K with a methane heat pipe is an important new thermal control capability for the lab. In addition, the two turn-off technologies enhance the "bag of tricks" available to the JPL thermal community. The successful test program brings this heat pipe to a high level of technology readiness.

cyrogenic heat pipe↗

Optical Geolocation for Small Unmanned Aerial Systems

This paper presents an airborne optical geolocation system using four optical targets to provide position and attitude estimation for a sUAS supporting the NASA Acoustic Research Mission (ARM), where the goal is to reduce nuisance airframe noise during approach and landing. A large precision positioned microphone array captures the airframe noise for multiple passes of a Gulfstream III aircraft. For health monitoring of the microphone array, the Acoustic Calibration Vehicle (ACV) sUAS completes daily flights with an onboard speaker emitting tones at frequencies optimized for determining microphone functionality. An accurate position estimate of the ACV relative to the array is needed for microphone health monitoring. To this end, an optical geolocation system using a downward facing camera mounted to the ACV was developed. The 3D positioning of the ACV is computed using the pinhole camera model. A novel optical geolocation algorithm first detects the targets, then a recursive algorithm tightens the localization of the targets. Finally, the position of the sUAS is computed using the image coordinates of the targets, the 3D world coordinates of the targets, and the camera matrix. A Real-Time Kinematic GPS system is used to compare the optical geolocation system.

Dolph, Chester V.↗

A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the performance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques.

Toland, Ronald W.↗