Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

FOC SV support and science data analysis

The main activity of NASA grant NAG5-1733 has been the study of Planetary Nebulae in the Magellanic Clouds through observations using the ESA Faint Object Camera conducted during Hubble Space Telescope (HST) Observing Cycles 1 and 2 in the pre-Costar era and in Cycle 4 with Costar and the FOC. A table of the observations obtained during these observing periods is attached along with figures showing the final images. Both the table and the figures are intended for publication later this year in the Astrophysical journal. Work that had been carried out under this grant included: astrometric measurement of ground-based images and preparation of detailed observing proposals; re-calibration of FOC images; deconvolution; and data analysis and measurement. The work has resulted in two papers, the first already published and the second in preparation by Blades, Osmer and Barlow. A reprint of the first paper is attached. The second paper will enlarge upon the results described in the first paper, bearing in mind the much larger sample of objects. Finally, the recently acquired images in Cycle 4 with the corrected optics will allow us to make direct and quantitative comparison between the pre- and post-correction for FOC. This work will be carried out under a separate grant. All the observations concerning Planetary Nebulae as described in an earlier status report have been collected and measured. In addition, a preliminary study of the photometric response of the FOC was begun under this grant but not completed because the analysis of the Cycle 2 Planetary Nebulae took much longer and was much more difficult than originally envisaged (due to the spherical aberration problem). However, because our data covers a long time period, we shall be able to deduce the photometric properties now using the actual PN themselves. This work will be carried out under a separate grant.

Blades, J. Chris↗

Lunar Reconnaissance Orbiter (LRO) Guidance, Navigation and Control (GN&C) Overview

The National Aeronautics and Space Administration s (NASA) Lunar Reconnaissance Orbiter (LRO) launched on June 18, 2009 from the Cape Canaveral Air Force Station aboard an Atlas V launch vehicle and into a direct insertion trajectory to the oon. LRO, which was designed, built, and operated by the NASA Goddard Space Flight Center in Greenbelt, MD, is gathering crucial data on the lunar environment that will help astronauts prepare for long-duration lunar expeditions. The mission has a nominal life of 1 year as its seven instruments find safe landing sites, locate potential resources, characterize the radiation environment, and test new technology. To date, LRO has been operating well within the bounds of its requirements and has been collecting excellent science data images taken from the LRO Camera Narrow Angle Camera of the Apollo landing sites appeared on cable news networks. A significant amount of information on LRO s science instruments is provided at the LRO mission webpage. LRO s Guidance, Navigation and Control (GN&C) subsystem is made up of an onboard attitude control system (ACS) and a hardware suite of sensors and actuators. The LRO onboard ACS is a collection of algorithms based on high level and derived requirements, and reflect the science and operational events throughout the mission lifetime. The primary control mode is the Observing mode, which maintains the lunar pointing orientation and any offset pointing from this baseline. It is within this mode that all science instrument calibrations, slews and science data is collected. Because of a high accuracy requirement for knowledge and pointing, the Observing mode makes use of star tracker (ST) measurement data to determine an instantaneous attitude pointing. But even the star trackers alone do not meet the tight requirements, so a six-state Kalman Filter is employed to improve the noisy measurement data. The Observing mode obtains its rate information from an inertial reference unit (IRU) and in the event of an IRU failure, the rate data is be derived from the star tracker, but with degraded pointing performance. The Delta-V control mode responsibility is to maintain attitude pointing during the cruise trajectory, insertion burns and lunar orbit maintenance by adjustments made to the spacecraft s velocity magnitude and vector direction. The ACS also provides for a thruster based system momentum management algorithm (known as Delta-H) to maintain the system and wheel momentum to within acceptable levels. In the event an anomaly causes the LRO spacecraft to lose the ability to maintain its current attitude pointing, a Sun Safe mode is included in the ACS for the purpose of providing a known power and thermally safe coarse inertial sun attitude for an indefinite period of time, within the manageable limits of the reaction wheels. The Sun Safe mode is also the initial spacecraft control mode off of the launch vehicle and provides for a means to null tip-off rates immediately after separation. The nominal configuration is to use the IRU for rate information in the controller. In the event of a gyro failure a gyroless control mode was developed that computes rate information from the CSS data.

Garrick, Joseph↗

Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System

As shown by the Phoenix Mars Lander's Thermal and Electrical Conductivity Probe (TECP), contact measurements of thermal conductivity and diffusivity (using a modified flux-plate or line-source heat-pulse method) are constrained by a number of factors. Robotic resources must be used to place the probe, making them unavailable for other operations for the duration of the measurement. The range of placement is also limited by mobility, particularly in the case of a lander. Placement is also subject to irregularities in contact quality, resulting in non-repeatable heat transfer to the material under test. Most important from a scientific perspective, the varieties of materials which can be measured are limited to unconsolidated or weakly-cohesive regolith materials, rocks, and ices being too hard for nominal insertion strengths. Accurately measuring thermal properties in the laboratory requires significant experimental finesse, involving sample preparation, controlled and repeatable procedures, and, practically, instrumentation much more voluminous than the sample being tested (heater plates, insulation, temperature sensors). Remote measurements (infrared images from orbiting spacecraft) can reveal composite properties like thermal inertia, but suffer both from a large footprint (low spatial resolution) and convolution of the thermal properties of a potentially layered medium. In situ measurement techniques (the Phoenix TECP is the only robotic measurement of thermal properties to date) suffer from problems of placement range, placement quality, occupation of robotic resources, and the ability to only measure materials of low mechanical strength. A spacecraft needs the ability to perform a non-contact thermal properties measurement in situ. Essential components include low power consumption, leveraging of existing or highly-developed flight technologies, and mechanical simplicity. This new in situ method, by virtue of its being non-contact, bypasses all of these problems. The use of photons to both excite and measure the thermal response of any surface material to a high resolution (estimated footprint = 10 square centimeters) is a generational leap in physical properties measurements. The proposed method consists of spot-heating the surface of a material with a low (less than 1 W) power laser. This produces a moderate (5-10 K) temperature increase in the material.

Hudson, Troy L.↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

First Annual Report on Pulsed Thermal Tomography Nondestructive Evaluation of Additively Manufactured Reactor Materials and Components: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This report provides results of preliminary performance evaluation of PTT capability in detection of flaws in metallic structures, as well imaging complex geometry AM structures. Performance of PTT was investigated through modeling and experiments, Computer models of PTT were developed using COMSOL Heat Transfer module. Defects were modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface. Preliminary experimental studies were performed to evaluate PTT performance in detecting calibrated flaws using metallic specimens with AM defects simulated as drilled-in FBH’s. High strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The diameters of FBH’s varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanical drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. Finally, PTT capability in imaging several AM structures fabricated from Inconel 718 (IN718) powder feedstock was investigated. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of AM IN718 nozzle plate and a particle filter plate. It was shown that PTT can scan through 2/3in-thick Inconel 718 plates in approximately 15s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages. The results demonstrate the capability of PTT in 3-D imaging of complex geometry AM structures. Intermediate results demonstrated in this report will be developed further to investigate detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stellar photometry in the inner bulge of M31 using the Hubble Space Telescope wide field camera

We present photometry of two fields in the M31 bulge imaged with the Hubble Space Telescope (HST) Wide-Field Camara (WFC). The nuclear field (r less than 40 arcsecs = 150 pc) giant branch extends to I = 19.5, M(sub I) = -5 (Cousins system), a full 0.9 mag brighter than the giant-branch tips of metal-poor Galactic globular clusters and M31 halo fields. This is also approximately = 1.5 mag brighter than the giant branches of metal-rich Galactic globular clusters, but is no brighter than Mould's (1986) M31 bulge field 1 kpc from the nucleus. The data also suggest that the brighter stars may be preferentially concentrated to the center. The 648 luminous stars detected in 2 x 10(exp 9) solar luminosity is approximately = 25% that expected from a hypothetical population of evolved asymptotic giant branch (AGB) stars with lifetimes approximately = 10(exp 5) yr, with the cautionary note that we are near the detection limit. The number of bright stars is also consistent with the progeny of blue stragglers, if one uses a lifetime for the thermal-pulsing AGB of 2 x 10(exp 6) yr. We strongly caution that incompleteness becomes severe below I = 19.9 mag and that future surveys are likely to find numbers of bright stars too large to accomodate the blue straggler progeny hypothesis. We have imaged an additional field 2 arcmin = 500 pc south of the nucleus. The brightest stars in this field are also I = 19.5, but bright stars appear less numerous than in the nuclear field. If the population resembles that of the Galactic bulge, then M(sub bol) = -4.5 is a lower limit to the giant-branch tip luminosity; infrared studies should reveal stars 0.5 mag or more brighter. Either high-metallicity or (more likely) age approximately = 10 Gyr may be responsible for the presence of these luminous AGB stars. These observations confirm that previous ground-based infrared studies (e.g., Rich & Mould 1991) very likely detect an extended giant branch and not spurious luminous stars caused by crowding or disk contamination. However, published integrated colors for the M31 bulge/nucleus are extremely red, making it difficult to accomodate a young or intermediate-age population.

Rich, R. M.↗

Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

Danehy, Paul M.↗

TPSAS-NF1676L-32020-DND

The Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) satellite has a constant unique view of the sunlit disk of the Earth from the Lagrange-1 (L1) point nearly a million miles away from the Earth. The DSCOVR EPIC team released the version 2 dataset last year which included many enhancements, such as improved navigation, stray-light correction, and flat-fielding. Since there is no on-board calibration for EPIC, its 10 spectral channels must be calibrated using other methods, such as inter-calibrating with sensors with on-board calibration hardware. VIIRS is a well-calibrated instrument with similar spectral channels as EPIC. Spectral band induced radiance differences between VIIRS and EPIC are mitigated using Spectral Band Adjustment Factor (SBAF). We will extend the previous calibrations from prior studies to include more recent data by ray-matching EPIC with VIIRS over all-sky tropical ocean (ATO) and deep convective cloud (DCC) conditions. In addition to ATO and DCC ray-matching, we will validate these results by utilizing DCC as invariant targets to monitor sensor degradation. DCC behave as solar diffusers in the tropics and when collectively analyzed can be used to monitor the degradation of the EPIC sensor. Improvement to our dynamic navigation adjustment algorithm, as well as exploring the view angle response of the EPIC CCD array, will be examined for their effectiveness and presented at the conference.

C O Haney↗

Quantitatively Monitoring Bubble-Flow at a Seep Site Offshore Oregon: Field Trials and Methodological Advances for Parallel Optical and Hydroacoustical Measurements

Two lander-based devices, the Bubble-Box and GasQuant-II, were used to investigate the spatial and temporal variability and total gas flow rates of a seep area offshore Oregon, United States. The Bubble-Box is a stereo camera–equipped lander that records bubbles inside a rising corridor with 80 Hz, allowing for automated image analyses of bubble size distributions and rising speeds. GasQuant is a hydroacoustic lander using a horizontally oriented multibeam swath to record the backscatter intensity of bubble streams passing the swath plain. The experimental set up at the Astoria Canyon site at a water depth of about 500 m aimed at calibrating the hydroacoustic GasQuant data with the visual Bubble-Box data for a spatial and temporal flow rate quantification of the site. For about 90 h in total, both systems were deployed simultaneously and pressure and temperature data were recorded using a CTD as well. Detailed image analyses show a Gaussian-like bubble size distribution of bubbles with a radius of 0.6–6 mm (mean 2.5 mm, std. dev. 0.25 mm); this is very similar to other measurements reported in the literature. Rising speeds ranged from 15 to 37 cm/s between 1- and 5-mm bubble sizes and are thus, in parts, slightly faster than reported elsewhere. Bubble sizes and calculated flow rates are rather constant over time at the two monitored bubble streams. Flow rates of these individual bubble streams are in the range of 544–1,278 mm 3 /s. One Bubble-Box data set was used to calibrate the acoustic backscatter response of the GasQuant data, enabling us to calculate a flow rate of the ensonified seep area (~1,700 m 2 ) that ranged from 4.98 to 8.33 L/min (5.38 × 10 6 to 9.01 × 10 6 CH 4 mol/year). Such flow rates are common for seep areas of similar size, and as such, this location is classified as a normally active seep area. For deriving these acoustically based flow rates, the detailed data pre-processing considered echogram gridding methods of the swath data and bubble responses at the respective water depth. The described method uses the inverse gas flow quantification approach and gives an in-depth example of the benefits of using acoustic and optical methods in tandem.

54 ENVIRONMENTAL SCIENCES↗

Switched Band-Pass Filters for Adaptive Transceivers

Switched band-pass filters are key components of proposed adaptive, software- defined radio transceivers that would be parts of envisioned digital-data-communication networks that would enable real-time acquisition and monitoring of data from geographically distributed sensors. Examples of sensors to be connected to such networks include security cameras, radio-frequency identification units, and geolocation units based on the Global Positioning System. Through suitable software configuration and without changing hardware, these transceivers could be made to operate according to any of a number of complex wireless-communication standards that could be characterized by diverse modulation schemes, bandwidths, and data-handling protocols. The adaptive transceivers would include field-programmable gate arrays (FPGAs) and digital signal-processing hardware. In the receiving path of a transceiver, the incoming signal would be amplified by a low-noise amplifier (LNA). The output spectrum of the LNA would be processed by a band-pass filter operating in the frequency range between 900 MHz and 2.4 GHz. Then a down-converter would translate the signal to a lower frequency range to facilitate analog-to-digital conversion, which would be followed by baseband processing by one or more FPGAs. In the transmitting path, a digital stream would first be converted to an analog signal, which would then be up-converted to a selected frequency band before being applied to a transmitting power amplifier. The aforementioned band-pass filter in the receiving path would be a combination of resonant inductor-and-capacitor filters and switched band-pass filters. The overall combination would implement a switch function designed mathematically to exhibit desired frequency responses and to switch the signal in each frequency band to an analog-to-digital converter appropriate for that band to produce a digital intermediate-frequency signal for digital signal processing.

Wang, Ray↗

High-Resolution UV/Optical/IR Imaging of Jupiter in 2016–2019

Imaging observations of Jupiter with high spatial resolution were acquired beginning in 2016, with a cadence of 53 days to coincide with atmospheric observations of the Juno spacecraft during each perijove pass. The Wide Field Camera 3 (WFC3) aboard the Hubble Space Telescope (HST) collected Jupiter images from 236 to 925 nm in 14 filters. The Near-Infrared Imager (NIRI) at Gemini North imaged Jovian thermal emission using a lucky-imaging approach (co-adding the sharpest frames taken from a sequence of short exposures), using the M' filter at 4.7 μm. We discuss the data acquisition and processing and an archive collection that contains the processed WFC3 and NIRI data (doi:10.17909/T94T1H). Zonal winds remain steady over time at most latitudes, but significant evolution of the wind profile near 24°N in 2016 and near 15°S in 2017 was linked with convective superstorm eruptions. Persistent mesoscale waves were seen throughout the 2016–2019 period. We link groups of lightning flashes observed by the Juno team with water clouds in a large convective plume near 15°S and in cyclones near 35°N–55°N. Thermal infrared maps at the 10.8 micron wavelength obtained at the Very Large Telescope show consistent high brightness temperature anomalies, despite a diversity of aerosol properties seen in the HST data. Both WFC3 and NIRI imaging reveal depleted aerosols consistent with downwelling around the periphery of the 15°S storm, which was also observed by the Atacama Large Millimeter/submillimeter Array. NIRI imaging of the Great Red Spot shows that locally reduced cloud opacity is responsible for dark features within the vortex. The HST data maps multiple concentric polar hoods of high-latitude hazes.

Michael H. Wong↗

Heavy Ion Fusion Science Virtual National Laboratory 4th Quarter 2009 Milestone Report: Measure and simulate target temperature and dynamic response in optimized NDCX-I configurations with initial diagnostics suite

This milestone has been met. The effort contains two main components: (1) Experimental results of warm dense matter target experiments on optimized NDCX-I configurations that include measurements of target temperature and transient target behavior. (2) A theoretical model of the target response to beam heating that includes an equilibrium heating model of the target foil and a model for droplet formation in the target for comparison with experimental results. The experiments on ion-beam target heating use a 300-350-keV K{sup +} pulsed beam from the Neutralized Compression Drift Experiment (NDCX-I) accelerator at LBNL. The NDCX-I accelerator delivers an uncompressed pulse beam of several microseconds with a typical power density of >100 kW/cm{sup 2} over a final focus spot size of about 1 mm. An induction bunching module the NDCX-I compresses a portion of the beam pulse to reach a much higher power density over 2 nanoseconds. Under these conditions the free-standing foil targets are rapidly heated to temperatures to over 4000 K. We model the target thermal dynamics using the equation of heat conduction for the temperature T(x,t) as a function of time (t) and spatial dimension along the beam direction (x). The competing cooling processes release energy from the surface of the foil due to evaporation, radiation, and thermionic (Richardson) emission. A description of the experimental configuration of the target chamber and results from initial beam-target experiments are reported in our FY08 4th Quarter and FY09 2nd Quarter Milestone Reports. The WDM target diagnostics include a high-speed multichannel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. The fast optical pyrometer is a unique and significant new diagnostic which provides valuable information on the temperature evolution of the heated target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of EPIC Oxygen Bands Stability With Radiative Transfer Simulations Over the South Pole

The Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) satellite orbiting the Sun at the Lagrange-1 point was launched without onboard calibration systems. Vicarious calibration is conducted for 8 of the 10 UV/VIS/NIR channels using other low earth orbiting satellite instruments, while its two O 2 bands (688 nm and 764nm) rely on indirect moon-view calibrations because the same narrow-band O 2 bands are not readily available from other in-flight instruments. This study compares EPIC measurements from the four O 2 bands aiming at examining sensor stability over a uniquely suited location, i.e., the permanently snow-covered South Pole. The study utilizes radiative transfer model simulations with in-situ atmospheric soundings taken at South Pole during months of December and January from 2015 to 2022. The absolute discrepancy between the model simulations and observations is less than 1.0% for the two reference bands, but 5.75% and 15.63% for the 688nm, and 764 nm absorption bands, respectively. The simulated A-band and B-band ratios are 16.09% and 4.74% higher than that from the observations. Various sensitivities are conducted to estimate possible contributions to the discrepancies from input atmospheric profiles, spectral surface albedos and surface BRDF. While none of the input uncertainties is likely to account for the large discrepancies in the oxygen absorption bands, a small shift in the instrument response function could be the main reason for these biases. On the other hand, the model simulations are able to capture systematic variations with observed angular measurements and explain the multi-year trends found in observed O 2 band ratios due to satellite orbit shifting. When model simulated contributions from the angle variations are deducted from the observed O 2 band ratios, the residual O 2 band ratios are found to be stable since 2015.

EPIC↗

First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

X-rays↗

Cratering Equations for Zinc Orthotitanate Coated Aluminum

The final STS-125 servicing mission (SM4) to the Hubble Space Telescope (HST) in May of 2009 saw the return of the 2nd Wide Field Planetary Camera (WFPC2) aboard the shuttle Discovery. This hardware had been in service on HST since it was installed during the SM1 mission in December of 1993 yielding one of the longest low Earth orbit exposure times (15.4 years) of any returned space hardware. The WFPC2 is equipped with a 0.8 x 2.2 m radiator for thermal control of the camera electronics (Figure 1). The space facing surface of the 4.1 mm thick aluminum radiator is coated with Z93 zinc orthotitanate thermal control paint with a nominal thickness of 0.1 0.2 mm. Post flight inspections of the radiator panel revealed hundreds of micrometeoroid/orbital debris (MMOD) impact craters ranging in size from less than 300 to nearly 1000 microns in diameter. The Z93 paint exhibited large spall areas around the larger impact sites (Figure 2) and the craters observed in the 6061-T651 aluminum had a different shape than those observed in uncoated aluminum. Typical hypervelocity impact craters in aluminum have raised lips around the impact site. The craters in the HST radiator panel had suppressed crater lips, and in some cases multiple craters were present instead of a single individual crater. Humes and Kinard observed similar behavior after the WFPC1 post flight inspection and assumed the Z93 coating was acting like a bumper in a Whipple shield. Similar paint behavior (spall) was also observed by Bland2 during post flight inspection of the International Space Station (ISS) S-Band Antenna Structural Assembly (SASA) in 2008. The SASA, with similar Z93 coated aluminum, was inspected after nearly 4 years of exposure on the ISS. The multi-crater phenomena could be a function of the density, composition, or impact obliquity angle of the impacting particle. For instance, a micrometeoroid particle consisting of loosely bound grains of material could be responsible for creating the multiple craters. Samples were obtained from the HST largest craters for examination by electron microscope equipped with x-ray spectrometers to determine impactor source (micrometeoroid or orbital debris). In an attempt to estimate the MMOD particle diameters that produced these craters, this paper will present equations for spall diameter, crater depth and crater diameter in Z93 coated aluminum. The equations will be based on hypervelocity impact tests of Z93 painted aluminum at the NASA White Sands Test Facility. Equations inputs for velocities beyond the testable regime are expected from hydrocode simulations of Z93 coated aluminum using CTH and ANSYS AUTODYN.

Hyde, James↗

Modifications of impurity transport and divertor sources by lithium wall conditioning in the National Spherical Torus Experiment

In the National Spherical Torus Experiment (NSTX), lithium coatings are evaporated on graphite plasma facing components (PFCs) for wall conditioning. In lithium-conditioned H-mode discharges, carbon accumulation is observed with core concentrations <10%, leading to a lack of density control, while lithium ions have concentrations <0.1%. In this thesis, modifications of carbon and lithium divertor sources as well as scrape-off layer (SOL) and core transport due to lithium conditioning are studied. Spectroscopic impurity influxes (measured by filtered cameras) and 2D multi-fluid edge transport simulations via the UEDGE code are employed to study divertor impurity sources and SOL transport, respectively. Core transport of carbon and lithium is analyzed using the impurity transport code MIST and the neoclassical transport codes NEO and NCLASS. A reduction of the carbon sputtering yield in the lower divertor is observed with lithium evaporation. However, weaker divertor impurity retention resulting from reduced recycling (inferred from UEDGE simulations) and the possible importance of wall sources can counteract this reduction in divertor carbon influxes. The suppression of edge-localized-modes (ELMs) is the primary cause of the increased carbon inventories in lithium-conditioned discharges, leading to lack of density control. Deviations from neoclassical predictions for carbon transport are observed at the pedestal top in lithium-conditioned discharges, indicating the presence of anomalous outward convection. While the lithium sputtering yield from lithium-coated graphite in the divertor is consistent with physical and temperature-enhanced sputtering, a strong reduction in ionized lithium influxes is observed, possibly due to prompt re-deposition. The different poloidal source distribution and the stronger divertor retention for lithium (inferred from UEDGE simulations) contribute to a lower edge lithium source with respect to carbon. The latter is due to the shorter lithium ionization mean-free-path and weaker classical parallel forces. The high neoclassical lithium diffusivity, due to collisions with carbon ions, is partially responsible for the low lithium core densities. Furthermore, the higher neoclassical levels make lithium transport closer to neoclassical expectations. The NSTX-Upgrade baseline scenario includes lithium coatings on graphite PFCs for deuterium particle control. While the remarkably good lithium divertor retention makes it an attractive choice, the suppression of ELMs leads to carbon accumulation and therefore to the need to develop impurity mitigation techniques.

impurity trasport↗

Surface Biology and Geology (SBG) Thermal Infrared (TIR) Free -Flyer Concept

Scientists and engineers from the United States and Italy are developing a thermal infrared (TIR) free-flyer concept that forms an essential element of the NASA Surface Biology & Geology (SBG) designated observable and the greater NASA Earth System Observatory (ESO), which also includes observations of aerosols, clouds, convection, and precipitation; mass change; and surface deformation & change.In response to the recommendations from the 2017 National Academies decadal survey for Earth science, NASA initiated the SBG designated observable with five key research and applications focus areas: ecosystems and natural resources, hydrology, weather, climate, and solid Earth. SBG includes spaceborne measurements of hyperspectral imagery in the visible to shortwave infrared (0.4-2.5 um) and multispectral imagery in the mid and thermal infrared (3-12 um) that provide the remote sensing data needed to inform each research and applications area. High-level TIR data products include Earth surface temperature & emissivity, evapotranspiration, substrate composition, volcanic plumes, and high-temperature features. While the science, applications, and technology build on prior mission studies conducted for more than a decade, it has only been recently that a joint team of scientists and engineers from the NASA Jet Propulsion Laboratory (JPL), Agenzia Spaziale Italiana (ASI), Istituto Nazionale Geofisica e Volcanologia (INGV), and the Istituto Nazionale Astrofisica (INAF) have developed a compelling concept for a TIR free-flyer. In this concept, the TIR instrument is an eight-band radiometer. Seven of the bands are between 3 and 12 um with an additional band at 1.65 um. The instrument’s 68.8 deg total viewing angle and the free-flyer’s 665 km operational altitude results in a ground sampling distance (GSD) of <60 m at nadir, produces a swath width of 935 km, and allows for a 2-3-day revisit time. A two-band visible and near infrared (VNIR) camera, with <30 m GSD at nadir and 935 km swath width, will complement the TIR instrument. VNIR high-level data products include top & bottom of atmosphere reflectance and normalized difference vegetation indices (NDVI). The TIR instrument and VNIR camera will be mounted on a PLATiNO+ spacecraft, a multi-application, reconfigurable, and scalable platform. The launcher selected for the TIR free-flyer is the VEGA-C. To maximize the science and applications benefits the SBG-TIR free-flyer team are collaborating with personnel from the ESA Land Surface Temperature Monitoring mission (LSTM) as well individuals from the Thermal Infrared Imaging Satellite for High-resolution Natural resource Assessment (TRISHNA), a joint mission by CNES and ISRO. Pre-Phase A concept studies for the SBG-TIR free-flyer commenced in the spring 2021. This allows for the concept to be refined; for technical risks to be identified and mitigated, as necessary; and strategies for reducing the development schedule to be defined and assessed before conducting a NASA-ASI Mission Concept Review (MCR) in the spring of 2022 and a NASA Key Decision Point-A (KDP-A) as early as the summer of 2022. These are key milestones in being able to launch and begin operating the SBG-TIR free-flyer in the second half of the decade, so that many of the questions posed by the National Academies in the 2017 decadal survey can be answered.

Fabrizia-Buongiorno, Maria↗

THE COMPTON-THICK SEYFERT 2 NUCLEUS OF NGC 3281: TORUS CONSTRAINTS FROM THE 9.7 {mu}m SILICATE ABSORPTION

We present mid-infrared (mid-IR) spectra of the Compton-thick Seyfert 2 galaxy NGC 3281, obtained with the Thermal-Region Camera Spectrograph at the Gemini-South telescope. The spectra present a very deep silicate absorption at 9.7 {mu}m, and [S IV] 10.5 {mu}m and [Ne II] 12.7 {mu}m ionic lines, but no evidence of polycyclic aromatic hydrocarbon emission. We find that the nuclear optical extinction is in the range 24 mag {<=} A{sub V} {<=} 83 mag. A temperature T = 300 K was found for the blackbody dust continuum component of the unresolved 65 pc nucleus and the region at 130 pc SE, while the region at 130 pc NW reveals a colder temperature (200 K). We describe the nuclear spectrum of NGC 3281 using a clumpy torus model that suggests that the nucleus of this galaxy hosts a dusty toroidal structure. According to this model, the ratio between the inner and outer radius of the torus in NGC 3281 is R{sub 0}/R{sub d} = 20, with 14 clouds in the equatorial radius with optical depth of {tau}{sub V} = 40 mag. We would be looking in the direction of the torus equatorial radius (i = 60{sup 0}), which has outer radius of R{sub 0} {approx} 11 pc. The column density is N{sub H} {approx} 1.2 x 10{sup 24} cm{sup -2} and the iron K{alpha} equivalent width ({approx}0.5-1.2 keV) is used to check the torus geometry. Our findings indicate that the X-ray absorbing column density, which classifies NGC 3281 as a Compton-thick source, may also be responsible for the absorption at 9.7 {mu}m providing strong evidence that the silicate dust responsible for this absorption can be located in the active galactic nucleus torus.

79 ASTRONOMY AND ASTROPHYSICS↗