Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

An Open-Source Decarbonization Analytics Framework: Designing for Low-Carbon Emission Districts and Communities: Preprint

This paper introduces an open-source analytics framework designed to assist in creating low or net-zero carbon buildings and urban districts. Integrated within URBANopt, an open-source platform for energy analysis in districts and communities, this framework equips researchers, architects, engineers, and other stakeholders with tools to evaluate the carbon footprint implications of their design choices. The framework enables the analysis of various scenarios, incorporating both historical and future emission factors, and can span across different climate zones, each with distinct grid and emissions characteristics. The results showcase the framework's capability to evaluate the impact of design upgrades and control strategies on carbon emissions in districts and communities. An illustrative analysis using a hypothetical district in Denver, Colorado, shows reduced emissions from energy efficiency upgrades and control strategies, highlighting the sensitivity in their effects on emissions and energy use.

buildings energy efficiency↗

Decarbonization Dilemmas: Deliberating Difficult Decisions in Laboratory Design

Dive into the depths of design and decision-making, while we discuss the decarbonization of laboratory buildings! Delve into the dense domain of laboratory design and operations, where every development presents a diverse array of dilemmas and delights. Join us for these dynamic sessions focused on decoding the secrets of sustainable success. Dig deep into the dynamic world of heat pump designs and the delicate balance of heating and cooling loads. Debate between constant and variable fume hood designs, where these decisions determine outcomes. Discover the divergent paths of HVAC system implementation, from the deployment of chilled beams to the diverse array of different terminal unit types. But don't delay; decisive action is demanded for these goals! Dare to dream of decarbonization as we direct discussions on retrofitting existing building stock versus innovative new design approaches. Delve into the depths of debate and emerge with a decisive strategy for sustainable success. Discuss recent discoveries in development from experts associated with existing laboratory buildings with decarbonization goals. These insights and lessons learned will help determine the path forward in our industry's drive for decarbonization designs. Decarbonization is no easy task, but with determination, dedication, and devotion, we can defy the odds and forge a brighter future for laboratory design and operations. Let's dare to decarbonize together!

decarbonization↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space conditioning loads.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BE-SATED: Building Energy Storage At The Edges of Demand

Otherlab is leading research efforts to validate and deploy battery-integrated appliances in real-world settings. The primary goal is to demonstrate the ability of these appliances to shift residential energy loads and reduce peak demand. Additionally, the project aims to secure safety certifications for battery-integrated appliances and establish a key industrial partnership with an appliance manufacturer for broader market adoption.

25 ENERGY STORAGE↗

Finite Element Analysis and Machine Learning Guided Design of Carbon Fiber Organosheet-Based Battery Enclosures for Crashworthiness

Carbon fiber composite can be a potential candidate for replacing metal-based battery enclosures of current electric vehicles (E.V.s) owing to its better strength-to-weight ratio and corrosion resistance. However, the strength of carbon fiber-based structures depends on several parameters that should be carefully chosen. Here, in this work, we implemented high throughput finite element analysis (FEA) based thermoforming simulation to virtually manufacture the battery enclosure using different design and processing parameters. Subsequently, we performed virtual crash simulations to mimic a side pole crash to evaluate the crashworthiness of the battery enclosures. This high throughput crash simulation dataset was utilized to build predictive models to understand the crashworthiness of an unknown set. Our machine learning (ML) models showed excellent performance (R 2 > 0.97) in predicting the crashworthiness metrics, i.e., crush load efficiency, absorbed energy, intrusion, and maximum deceleration during a crash. We believe that this FEA-ML work framework will be helpful in down select process parameters for carbon fiber-based component design and can be transferrable to other manufacturing technologies.

36 MATERIALS SCIENCE↗

Microstructure effects on fatigue crack growth in additively manufactured Ti–6Al–4V

In this article we investigate the relationship between the different microstructural features in additively-manufactured (AM) Direct Metal Laser Deposited Ti–6Al–4V alloys and the observed fatigue and fracture behaviors, using high resolution Digital Image Correlation experiments and microstructural imaging. Fatigue cracks in the AM specimens were observed to periodically propagate parallel to the α' laths and deflect at prior β grain boundaries. Corresponding plastic strain distributions show needle-like regions of high strain that correlated to the α' laths, suggesting significant influence of the microstructure on the plastic zone. In many cases, the fatigue cracks also propagated towards voids from unsintered powder or gas entrapment in the vicinity. In several experiments, premature failure of the AM specimens occurred under monotonic fracture or cyclic fatigue loading, which we attribute to the presence of void clusters located near the crack-tip. These fatigue and fracture characteristics were similar for AM specimens of different build-orientations.

36 MATERIALS SCIENCE↗

Design, Prototyping, Fabrication and Test of the Mu2e AC-Dipole Magnet

Fermilab Magnet Systems is building three High-frequency AC-Dipole Magnets for the Mu2e experiment at Fermilab. These magnets are composed of three single-loop one-meter-long ferrite loaded segments. The excitation consists of a copper tube, which is also used as a means for its cooling with the inherited challenges of Voltage and Frequency uncoupling. These magnets are designed to operate either at 300 kHz or 4.4 MHz via resonance tuning. Following the completion of the design, prototyping, and analysis phases, all ferrites and other components were procured, and the magnets were fabricated to meet vacuum compatibility requirements using strict procedures. Each magnet undergoes thorough baking and testing before being installed in the experiment. This paper discusses the magnets' role in proton background suppression as it represents a unique and essential device for the Mu2e experiment at Fermilab. We present the magnet design choices, modeling approach, and the challenges encountered during fabrication. Additionally, we outline the power supply driving mechanism, the testing that was performed, and our results.

Elementi, Luciano [Fermilab] (ORCID:00000002766372↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting Wind Loading and Instability in Solar Tracking PV Arrays

Wind loading and the fluctuating pressure loads it creates on PV panel surfaces are associated with multiple degradation mechanisms and failures. Modest wind speeds create reversing loads that can initiate cell cracks and weather cracked cells. Stronger wind speeds and extreme weather events can lead to larger scale forces and the aerodynamic instability known as torsional galloping. All these effects are dependent on the complex coupling between wind speed, panel orientation, and a myriad of other hardware and site-specific factors. In this work, we present the latest developments from our work to build an open-source, high-performance computing (HPC) fluid dynamics solver to predict and mitigate these effects. This simulation package allows users to easily specify different array layouts, solar-tracking angles, panel geometries, and weather conditions before automatically generating a refined computational mesh and solving for the unsteady loading on each panel surface. Small domains (e.g., a single panel row in isolation) can be solved on a modern laptop, while larger domains or very high-fidelity studies can be solved on distributed or HPC resources with minimal modifications to the underlying problem specification. We present preliminary case studies obtained using this simulation package and highlight how increased wind speeds combined with sub-optimal tracking angles can exacerbate degradation drivers.

aerodynamics↗

Computer Vision on Edge Devices for the Short Term Prediction of Cloud Cover

Edge Computing and IoT are important pieces of today's technological landscape. Here, we build a low-cost IoT sensor for sky imaging and program it using AWS GreenGrass, one of the leading IoT platforms. We demonstrate remote reprogramming of this device to load software that predicts sun shading events through the linear advection method, which is a baseline algorithm that can be used to benchmark algorithmic improvements in future work. Some future directions for sky imaging research are enumerated.

14 SOLAR ENERGY↗

Development of a medium-duty stoichiometric diesel micro-pilot natural gas engine

Fueling a compression-ignition engine with premixed natural gas offers the potential to combine a clean-burning, low-carbon fuel with a high compression ratio, high-efficiency engine. This work describes the development of a multi-cylinder 6.7 L diesel engine converted to run stoichiometric diesel micro-pilot/ natural gas premix combustion with a maximum diesel contribution target of 5% of the total fuel energy and a three-way catalyst aftertreatment system. Results are given by comparing the stoichiometric combustion to the diesel baseline operation, showing combustion characteristics differences, including the rapid two stage heat release. A high load output of 23 bar brake mean effective pressure was obtained with diesel-like brake thermal efficiency of 41%. This operating condition enabled a brake specific CO 2 emissions reduction of up to 25% when compared to diesel. It was observed that the low load output is limited by combustion stability when operated at stoichiometric condition. The three-way catalyst is observed to run at peak efficiency with an equivalence ratio of 1.01. Injector fouling was observed through the inspection of the nozzle and its internal parts, indicating carbon build-up similar to that seen in injector coking mechanisms. A comparison of the developed engine to other engine technologies is given, showing that the diesel micro-pilot natural gas engine performance is in good standing among other diesel and gas engines in the market.

Engineering↗

Electrification Futures Study Flexible Load Profiles

This data set includes hourly profiles for flexible load developed for the Electrification Futures Study (EFS). The load profiles represent projected end-use electricity demand that is assumed to be flexible (i.e., can be shifted throughout a day) for various scenarios of flexibility (Base, Enhanced), electrification (Reference, Medium, High), and technology advancement (Slow, Moderate, Rapid), and were developed as inputs into the ReEDS model. The quantity of flexible load is estimated using assumptions on the level of flexibility and customer participation within each subsector modeled in the EFS. Detailed assumptions and modeling implementation will be documented in ongoing EFS analyses. Flexible load profiles are provided for a subset of years (2018, 2020, 2024, 2030, 2040, 2050) and are aggregated to the state and sector level. Total electricity load profiles can be found in a related EFS data set (https://dx.doi.org/10.7799/1593122). NOTE: Due to the file size, Mac users may experience issues decompressing the zip files using the Mac Archive Utility. In those cases, decompressing using the command line is recommended. - Mai, Trieu, Paige Jadun, Jeffrey Logan, Colin McMillan, Matteo Muratori, Daniel Steinberg, Laura Vimmerstedt, Ryan Jones, Benjamin Haley, and Brent Nelson. 2018. Electrification Futures Study: Scenarios of Electric Technology Adoption and Power Consumption for the United States. National Renewable Energy Laboratory. NREL/TP-6A20-71500. https://doi.org/10.2172/1459351. - Murphy, Caitlin, Trieu Mai, Yinong Sun, Paige Jadun, Matteo Muratori, Brent Nelson, Ryan Jones. Forthcoming. Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States. National Renewable Energy Laboratory. - Sun, Yinong, Paige Jadun, Brent Nelson, Matteo Muratori, Caitlin Murphy, Jeffrey Logan, and Trieu Mai. Forthcoming. Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification. National Renewable Energy Laboratory.

buildings↗

Impact of Connected Communities

Buildings account for 35% of CO 2 emissions and almost 40% of the United States’ energy use. High-performance homes and neighborhoods play an important role in supporting efforts to decarbonize the US power system by 2035. Significant reductions in CO 2 emissions within the residential sector can be realized through electrification of loads paired with the flexibility created by leveraging smart Internet of Things (IoT) capabilities to shift energy use based on grid signals, thus improving generation/distribution efficiency and maximizing the use of renewable generation capacity. All of this can be achieved while allowing smart home appliances and equipment to meet homeowner needs – including reducing power bills - while optimizing operation in conjunction with the grid using novel control techniques. The Grid-Interactive Efficient Buildings Roadmap by the US Department of Energy’s (DOE’s) Building Technologies Office (BTO) notes that implementing grid-interactive efficient building (GEB) technology has the potential to reduce CO 2 emissions by 80 million tons/year—roughly equivalent to 17 million cars. To achieve this vision, the US Department of Energy’s Oak Ridge National Laboratory (ORNL)—in collaboration with Southern Company Research & Development, Alabama Power, Georgia Power, BTO and the US DOE’s Office of Electricity (OE) —is developing and demonstrating novel connected communities at two locations. Southern Company in turn engaged with industry partners, including design firms, residential developers, and residential HVAC and appliance manufacturers because their participation would be critical to the success of the initial research project, as well as the future scaling to the Southern Company service territory and beyond. Impacts of the Connected Communities projects in Alabama and Georgia are outlined including: energy, grid services and data management learnings; homeowner feedback; vendor engagement; adoption by utilities; technical, policy and business model challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Frequency Disturbance Event Detection Based on Synchrophasors and Deep Learning

Power system frequency disturbances are caused by various generation and transmission events including generator trips, load disconnections, line trips, etc. Accurate detections of the events are crucial to bulk power system situation awareness and event investigation. This paper utilizes the recent advances of deep learning to build a convolutional neural network model to detect events in an accurate yet straightforward manner. Herein, the rate of change of frequency and the relative angle shift are converted to images as the inputs of the proposed model. Finally, this paper uses two convolutional neural networks and classifier fusion to achieve the detection result. Compared with the conventional event detection algorithm and the frequency only deep learning model, the proposed model improves the detection accuracy by over 48%. As a promising tool for bulk power system situation awareness, the proposed model requires a short decision time, which is suitable for practical scenarios.

42 ENGINEERING↗

FY22 Laboratory Directed Research and Development Annual Report

The Laboratory Directed Research and Development (LDRD) program yields foundational scientific research and development (R&D) essential to growing SRNL’s core competencies, in alignment with SRNL’s Strategic Plan to provide long-term benefits to the Department of Energy (DOE), the National Nuclear Security Administration (NNSA), and other customers and stakeholders. Five strategic goals are outlined in SRNL’s strategic plan: 1) Provide applied science and engineering for EM’s active clean-up sites and LM’s post closure management sites; 2) Provide science-based solutions for gaps identified in nonproliferation strategic vision and support the government in actives impacting national security; 3) Lead ST&E as the central technical authority for processing tritium loaded reservoirs and support production of plutonium pits; 4) Align science and energy security programs by focusing modern modeling, simulation, and data analytics tools on materials engineering and performance applications; 5) Build a workforce for the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probabilistic Assessment of Structural Integrity

A probability-based approach, combining deterministic and probabilistic methods, was developed for analyzing building and component failures, which are especially crucial for complex structures like nuclear power plants. This method links finite element and probabilistic software to assess structural integrity under static and dynamic loads. This study uses NEPTUNE software, which is validated, for a deterministic transient analysis and ProFES software for probabilistic models. In a case study, deterministic analyses with varied random variables were transferred to ProFES for probabilistic analyses of piping failure and wall damage. A Monte Carlo Simulation, First-Order Reliability Method, and combined methods were employed for probabilistic analyses under severe transient loading, focusing on a postulated accident at the Ignalina Nuclear Power Plant. The study considered uncertainties in material properties, component geometry, and loads. The results showed the Monte Carlo Simulation method to be conservative for high failure probabilities but less so for low probabilities. The Response Surface/Monte Carlo Simulation method explored the impact load–failure probability relationship. Given the uncertainties in material properties and loads in complex structures, a deterministic analysis alone is insufficient. Probabilistic analysis is imperative for extreme loading events and credible structural safety evaluations.

Mathematics↗