Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below- threshold ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Sensitivity of neutrino mass experiments to the cosmic neutrino background

The KATRIN neutrino experiment is a next-generation tritium beta decay experiment aimed at measuring the mass of the electron neutrino to better than 200 meV at 90% C.L. Because of its intense tritium source, KATRIN can also serve as a possible target for the process of neutrino capture, {nu}{sub e}+{sup 3}H{yields}{sup 3}He{sup +}+e{sup -}. The latter process, possessing no energy threshold, is sensitive to the cosmic neutrino background (C{nu}B). In this paper, we explore the potential sensitivity of the KATRIN experiment to the relic neutrino density. The KATRIN experiment is sensitive to a C{nu}B overdensity ratio of 2.0x10{sup 9} over standard concordance model predictions (at 90% C.L.), addressing the validity of certain speculative cosmological models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduced-Cost Four-Component Relativistic Double Ionization Potential Equation-of-Motion Coupled-Cluster Approaches with 4-Hole–2-Particle Excitations and Three-Body Clusters

The double ionization potential (DIP) equation-ofmotion (EOM) coupled-cluster (CC) method with 4-hole−2- particle (4h-2p) excitations on top of the CC with singles, doubles, and triples calculation, abbreviated as DIP-EOMCCSDT(4h-2p), along with its perturbative DIP-EOMCCSD(T)(a)(4h-2p) approximation, are extended to a relativistic four-component (4c) framework. In addition, we introduce and test a new computationally practical DIP-EOMCC approach, which we call DIPEOMCCSD( T)(ã)(4h-2p), that approximates the treatment of 4h- 2p correlations within the DIP-EOMCCSD(T)(a)(4h-2p) method and reduces the $\mathcal{N}$ 8 scaling characterizing DIP-EOMCCSDT(4h- 2p) and DIP-EOMCCSD(T)(a)(4h-2p) to $\mathcal{N}$ 7 with the system size $\mathcal{N}$. Further improvements in computational efficiency are obtained using the frozen natural spinor (FNS) approximation to reduce the numbers of unoccupied spinors entering the correlated steps of the DIP-EOMCC calculations according to a well-defined occupation-number-based threshold. The resulting 4c-FNS-DIPEOMCC approaches are used to compute DIPs for the series of inert gas atoms from argon to radon as well as the vertical DIPs in Cl 2 , Br 2 , HBr, and HI, which have been experimentally examined in the past. We demonstrate that, when using complete basis set extrapolations and FNS truncation threshold of 10 −4.5 , the 4c-FNS-DIP-EOMCCSD(T)(ã)(4h-2p) calculations are capable of predicting DIPs in agreement with experimental data, improving upon their nonrelativistic and spin-free scalar-relativistic counterparts, particularly when examining DIPs characterized by stronger spin−orbit coupling effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum Cherenkov radiation in quantum electrodynamics with high-energy Lorentz violation

We study phenomena predicted by a renormalizable, CPT invariant extension of the standard model that contains higher-dimensional operators and violates Lorentz symmetry explicitly at energies greater than some scale {Lambda}{sub L}. In particular, we consider the Cherenkov radiation in vacuo. In a rather general class of dispersion relations, there exists an energy threshold above which radiation is emitted. The threshold is enhanced in composite particles by a sort of kinematic screening mechanism. We study the energy loss and compare the predictions of our model with known experimental bounds on Lorentz violating parameters and observations of ultrahigh-energy cosmic rays. We argue that the scale of Lorentz violation {Lambda}{sub L} (with preserved CPT invariance) can be smaller than the Planck scale, actually as small as 10{sup 14}-10{sup 15} GeV. Our model also predicts the Cherenkov radiation of neutral particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A plasma–vacuum interface tracking algorithm for magnetohydrodynamic simulations of coaxial plasma accelerators

The resistive Magneto-hydrodynamic (MHD) model describes the behavior of a strongly ionized plasma in the presence of external electric and magnetic fields. For problems involving the plasma with an open boundary to very low pressure/vacuum regions, the continuum assumption is no longer valid in the entire domain of interest. For example, this is seen in a plasma accelerator where a dense plasma expands into a vacuum background. A common practice to deal with this issue is to assign small values of density and pressure to the vacuum regions and proceed to solve the continuum based MHD equations throughout the domain. We show that this approach fails to produce solutions consistent with the physics of the problem and can give rise to unacceptable artifacts such as spurious shocks. Here, we develop a plasma–vacuum interface tracking approach to mitigate this problem. The plasma–vacuum interface is tracked in a physically consistent manner and the MHD equations are solved only in the regions that contain the plasma. The interface tracking is achieved using a face-flux formulation derived from the theoretical solution to a 1D free expansion problem. Coupled with a threshold based approach, the interface tracking is implemented for both explicit and implicit time stepping frameworks on generalized unstructured grids. Simulations of magnetized thermal plasma jets expanding into a vacuum background indicate plume profiles devoid of the unphysical shock obtained using the small background density approach. In the context of resistive MHD simulations, the interface tracking approach overcomes the numerical stiffness induced by specifying a large background resistivity in the vacuum regions, resulting in significant wall-clock time gains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Octavius1500 2D ion chamber array and its associated phantoms: Dosimetric characterization of a new prototype

Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius{sup ®} 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.06 cm{sup 3} cubic ion chambers are now arranged in a checkerboard pattern, leaving no lines (neither longitudinally nor laterally) without detectors. Methods: All measurements were performed on a dual energy (6 MV and 18 MV) iX Clinac (Varian Medical Systems, Palo Alto, CA) and all calculations were done in the Eclipse treatment planning system (Varian) with the Anisotropic Analytical Algorithm. First, the basic characteristics of the 2D array, such as measurement stability, dose rate dependence and dose linearity were investigated in the solid water sandwich setup. Second, the directional dependence was assessed to allow the evaluation of the new Octavius2D phantom (Oct2D{sup 1500}) for planar verification measurements of composite plans. Third, measurements were performed in the Oct4D phantom to evaluate the impact of the increased detector density on the accuracy of the volumetric dose reconstruction. Results: While showing equally good dose linearity and dose rate independence, the Octavius1500 outperforms the previous models because of its instantaneous measurement stability and its twofold active area coverage. Orthogonal field-by-field measurements immediately benefit from the increased detector density. The 3.9 cm wide compensation cavity in the new Oct2D{sup 1500} phantom prototype adequately corrects for directional dependence from the rear, resulting in good agreement within the target dose. Discrepancies may arise towards the sides of the array because of uncompensated lateral beam incidence. The beneficial impact of the detector density is most prominent in the Oct4D system, for which the average pass rate (PR) is now nearly 100% (99.31 ± 0.37) when using gamma criteria of 2%G,2 mm (10% dose threshold). In search of gamma analysis criteria that are not too lenient to detect possibly relevant deviations, the authors conclude that for our radiotherapy environment, the authors choose to adopt 3%L,3 mm PR97% (threshold 10%) criteria for the Oct2D{sup 1500}/Octavius1500 system and 2%L,3 mm PR97% (threshold 10%) for the Oct4D/Octavius1500 system. These are first line pass/check criteria and plans that fail are not necessarily rejected, but submitted to a more detailed investigation. Conclusions: When irradiated from the front, the Octavius1500 array has two main advantages over its 729 predecessors: its instantaneous measurement stability and-–most importantly—its twofold detector density. In the Oct2D1500 phantom, these advantages are counterbalanced by the more pronounced directional dependence. The measurement-based 3D dose reconstruction in the Oct4D system, however, benefits considerably from the higher detector density in the checkerboard panel design.

07 ISOTOPE AND RADIATION SOURCES↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Background-Subtracted Search for Annual Modulation in CDMS II

The identification of dark matter is one of the outstanding problems of our time. Cos- mological and astrophysical clues such as structure formation and relic densities, anomalous galaxy rotation curves, and mass density profiles provide ample evidence of an undetected mass component of the universe. Meanwhile, recent advancements in particle physics point toward extensions to the Standard Model, many of which posit candidates for new particles and new physics at the weak scale and beyond. If, as expected, the confluence of the hints of new physics in particle physics, astrophysics, and cosmology at the weak scale is more than coincidence, the detection of dark matter will pave the way for a paradigm shift in our fundamental understanding of the universe.Weakly interacting massive particles (WIMPs), in particular, are a well-motivated class of candidates for particle dark matter. Naturally predicted in supersymmetry (SUSY), WIMPs are stable, weakly-interacting, and produced in sufficient abundance to comprise the quantity of missing mass in a number of simple cases. Over the last two decades of experimentation, significant areas of the parameter space defined by the simplest SUSY theories have been ruled out, but WIMPs and related particles remain compelling candidates for dark matter searches.Several avenues for the detection and identification of dark matter are currently being pursued. The present work is a description of the search for a direct detection of super- symmetric dark matter via scattering from standard model particles. The Cryogenic Dark Matter Search (CDMS) Experiment uses ionization and athermal phonon sensor technolo- gies to achieve event-by-event discrimination of electron and nuclear recoils in cryogenic germanium crystal detectors. At low energies, where the the ability to discriminate individ- ual nuclear recoil events from background is reduced, a periodic variation of the rate and crossover signatures in the energy spectrum can aid the identification of a WIMP signature in the presence of significant backgrounds. In general, the direct detection of dark matter is the first step toward the identification and classification of dark matter in the universe.This work describes a background-subtracted search for annual modulation in the WIMP- search data acquired in the Cryogenic Dark Matter Search II (CDMS II) Experiment, which was the second implementation of the highly successful CDMS technology. We observe no significant modulation in the 2.7 keVnr to 11.9 keVnr (nuclear-recoil-equivalent) energy range selected for this analysis. These results are not compatible with a WIMP dark matter interpretation of the signals reported by the DAMA/LIBRA and CoGeNT experiments, and provide complementary support to earlier CDMS low-threshold germanium analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Establishing an optimized patient-specific verification program for volumetric modulated arc therapy

Quality assurance (QA) of volumetric modulated arc therapy (VMAT) increases the workload significantly. We compared the results from 4 verification methods to establish an efficient VMAT QA. Planning for VMAT treatments was carried out for 40 consecutive patients. Pretreatment verifications were carried out with ion chamber array Physikalish-Technische Werkstätten (PTW729), electronic portal dosimetry (EPID), ion chamber measurements, and independent dose calculation with Diamond program. 2D analyses were made using the gamma analysis (3 mm distance to agreement and 3% dose difference relative to maximum, 10% dose threshold). Average point dose difference calculated by Eclipse relative to ion chamber measurements and Diamond were 0.1%±0.9% and 0.6%±2.2%, respectively. Average pass rate for PTW729 was 99.2%±1.9% and 98.3%±1.3% for EPID. The total required time (linac occupancy time given in parentheses) for each QA method was: PTW729 43.5 minutes (26.5 minutes), EPID 14.5 minutes (2.5 minutes), ion chamber 34.5 minutes (26.5 minutes), and Diamond 12.0 minutes (0 minute). The results were consistent and allowed us to establish an optimized protocol, considering safety and accuracy as well as workload, consisting of 2 verification methods: EPID 2D analysis and independent dose calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: Measurements with diode arrays

Purpose: Compensator-based IMRT coupled with the high dose rate flattening filter free (FFF) beams offers an intriguing possibility of delivering an intensity modulated radiation field in just a few seconds. As a first step, the authors evaluate the dosimetric accuracy of the treatment planning system (TPS) FFF beam model with compensators. Methods: A 6 MV FFF beam from a TrueBeam accelerator (Varian Medical Systems, Palo Alto CA) was modeled in PINNACLE TPS (v. 9.0, Philips Radiation Oncology, Fitchburg WI). Flat brass slabs from 0.3 to 7 cm thick and an 18 deg. brass wedge were used to adjust the beam model. A 2D (MAPCHECK) and 3D (ARCCHECK) diode arrays (Sun Nuclear Corp, Melbourne FL), were investigated for use with the compensator FFF beams. Corrections for diode sensitivity caused by the spectral changes in the beam were introduced. Four compensator plans based on the AAPM TG-119 report were developed. A composite ion chamber measurement, beam by beam MAPCHECK measurements, and a composite ARCCHECK measurement were performed. The array results were analyzed with the same thresholds as in TG-119 report--3%/3 mm with global dose normalization--as well as with the more stringent combinations of the gamma analysis criteria. Results: The FFF beam shows a greater variation of the effective attenuation coefficient with brass thickness due to the prevalence of the low energy photons compared to the conventional 6X beam. As a result, a compromise had to be made while trying to achieve dose agreement for a combination of field sizes, brass thicknesses, and measurement depths ({>=}5 cm in water). An agreement of measured and calculated dose to within 1% was observed for brass thicknesses up to 2 cm. For the 3 cm slab, an error of up to 2.8% was noted for the field sizes above 10 x 10 cm{sup 2}, and up to 3.8% for the 5 x 5 cm{sup 2} field. Both diode arrays exhibit a substantial sensitivity drop as the compensator thickness increases, reaching 10% for a 7 cm brass slab. A simple correction based on the brass thickness along the ray was introduced to counteract this effect. Pooled for five profiles, the average ratio of uncorrected and corrected MAPCHECK to ion chamber readings are 0.966 and 1.008, respectively. With the proper correction, all MAPCHECK measurement to calculation comparisons exhibit 100%{gamma}(3%/3 mm) passing rates with global dose-error normalization. For the TG-119-type plans, the average {gamma}(2%/2 mm) passing rate with local normalization is 94% (range 87.8%-98.3%). The lower ARCCHECK{gamma}-analysis passing rates (corrected for diode sensitivity) are predictable based on the observed PDD discrepancies. However, with the 3%/3 mm thresholds and global normalization, the average {gamma}-analysis passing rate is 96.4% (range 89.9%-100%). Conclusions: MAPCHECK analysis demonstrates high passing rates with the stringent {gamma}(2%/2 mm) and local normalization criteria combination. The geometry of the ARCCHECK array creates a stress test for the FFF TPS model because of the shallow depth of the entrance diodes and large air cavity. Hence, the ARCCHECK{gamma}-analysis passing rates are lower than with the MAPCHECK, while still on par with TG-119.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-RAY AND GAMMA-RAY FLASHES FROM TYPE Ia SUPERNOVAE?

We investigate two potential mechanisms that will produce X-ray and gamma-ray flashes from Type Ia supernovae (SN-Ia). The first mechanism is the breakout of the thermonuclear burning front as it reaches the surface of the white dwarf (WD). The second mechanism is the interaction of the rapidly expanding envelope with material within an accretion disk in the progenitor system. Our study is based on the delayed detonation scenario because this can account for the majority of light curves, spectra, and statistical properties of 'Branch-normal' SN-Ia. Based on detailed radiation-hydro calculations which include nuclear networks, we find that both mechanisms produce brief flashes of high-energy radiation with peak luminosities of 10{sup 48}-10{sup 50} erg s{sup -1}. The breakout from the WD surface produces flashes with a rapid exponential decay by 3-4 orders of magnitude on timescales of a few tenths of a second and with most of the radiation in the X-ray and soft gamma-ray range. The shocks produced in gases in and around the binary will produce flashes with a characteristic duration of a few seconds with most of the radiation coming out as X-rays and gamma-rays. In both mechanisms, we expect a fast rise and slow decline and, after the peak, an evolution from hard to softer radiation due to adiabatic expansion. In many cases, flashes from both mechanisms will be superposed. The X- and gamma-ray visibility of an SN-Ia will depend strongly on self-absorption within the progenitor system, specifically on the properties of the accretion disk and its orientation toward the observer. Such X-ray and gamma-ray flashes could be detected as triggered events by gamma-ray burst (GRB) detectors on satellites, with events in current GRB catalogs. We have searched through the GRB catalogs (for the BATSE, HETE, and Swift experiments) for GRBs that occur at the extrapolated time of explosion and in the correct direction for known Type Ia supernovae with radial velocity of less than 3000 km s{sup -1}. For the Burst and Transient Source Experiment (BATSE) about 12.9 +- 3.6 nearby SNe Ia should have been detected, but only 0.8 +- 0.7 non-coincidental matches have been found. With the High Energy Transient Explorer (HETE) and Swift satellites, we expect to see 5.6 +- 1.3 SN-Ia flashes from known nearby SNe Ia but, yet, no SN-Ia flashes were detected. With the trigger thresholds for these experiments and the upper limits on the SN-Ia distances, we show that the bolometric peak luminosity of SN-Ia flashes must be less approx10{sup 46} erg s{sup -1}. Our observational limit is several orders-of-magnitude smaller than the peak luminosities predicted for both the early flashes. We attribute this difference to the absorption of the X- and gamma-rays by the accretion disk of large-scale height or common envelope that would be smothering the WD.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

POPULATION III GAMMA-RAY BURST AFTERGLOWS: CONSTRAINTS ON STELLAR MASSES AND EXTERNAL MEDIUM DENSITIES

Population (Pop.) III stars are theoretically expected to be prominent around redshifts z {approx} 20, consisting of mainly very massive stars with M{sub *} {approx}> 100 M{sub sun}, though there is no direct observational evidence for these objects. They may produce collapsar gamma-ray bursts (GRBs), with jets driven by magnetohydrodynamic processes, whose total isotropic-equivalent energy could be as high as E{sub iso} {approx}> 10{sup 57} erg over a cosmological-rest-frame duration of t{sub d} {approx}> 10{sup 4} s, depending on the progenitor mass. Here, we calculate the afterglow spectra of such Pop. III GRBs based on the standard external shock model and show that they will be detectable with the Swift Burst Alert Telescope (BAT)/XRT and Fermi Large Area Telescope (LAT) instruments. We find that in some cases a spectral break due to electron-positron pair creation will be observable in the LAT energy range, which can put constraints on the ambient density of the pre-collapse Pop. III star. Thus, high-redshift GRB afterglow observations could be unique and powerful probes of the properties of Pop. III stars and their environments. We examine the trigger threshold of the BAT instrument in detail, focusing on the image trigger system, and show that the prompt emission of Pop. III GRBs could also be detected by BAT. Finally we briefly show that the late-time radio afterglows of Pop. III GRBs for typical parameters, despite the large distances, can be very bright: {approx_equal} 140 mJy at 1 GHz, which may lead to a constraint on the Pop. III GRB rate from the current radio survey data, and {approx_equal} 2.4 mJy at 70 MHz, which implies that Pop. III GRB radio afterglows could be interesting background source candidates for 21 cm absorption line detections.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution Phase-Contrast Imaging of Submicron Particles in Unstained Lung Tissue

To access the risks and chances of deposition of submicron particles in the gas-exchange area of the lung, a precise three-dimensional (3D)-localization of the sites of deposition is essential--especially because local peaks of deposition are expected in the acinar tree and in individual alveoli. In this study we developed the workflow for such an investigation. We administered 200-nm gold particles to young adult rats by intratracheal instillation. After fixation and paraffin embedding, their lungs were imaged unstained using synchrotron radiation x-ray tomographic microscopy (SRXTM) at the beamline TOMCAT (Swiss Light Source, Villigen, Switzerland) at sample detector distances of 2.5 mm (absorption contrast) and of 52.5 mm (phase contrast). A segmentation based on a global threshold of grey levels was successfully done on absorption-contrast images for the gold and on the phase-contrast images for the tissue. The smallest spots containing gold possessed a size of 1-2 voxels of 370-nm side length. We conclude that a combination of phase and absorption contrast SRXTM imaging is necessary to obtain the correct segmentation of both tissue and gold particles. This method will be used for the 3D localization of deposited particles in the gas-exchange area of the lung.

60 APPLIED LIFE SCIENCES↗

Analysis of {alpha}-induced reactions on {sup 151}Eu below the Coulomb barrier

Novel measurements of ({alpha},{gamma}) and ({alpha},n) reaction cross sections on the target nucleus {sup 151}Eu, close to the reaction thresholds, support the choice of recently proposed parameters of the {alpha}-particle optical model potential below the Coulomb barrier. A better understanding of the {alpha}-particle optical potential at these energies leads to a statistical model analysis of additional partial cross sections that were measured but not considered within a former model analysis. On this basis we have tentatively assigned a modified J{sup {pi}}=9{sup -} spin and parity to the 22.7-h isomer in {sup 154}Tb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stellar (n, gamma) cross sections of neutron-rich nuclei

The present measurements were performed by means of the activation technique. Neutrons were produced at the Karlsruhe Van de Graaff accelerator via the {sup 7}Li(p,n){sup 7}Be reaction. For proton energies just above threshold, one obtains a neutron spectrum similar to a Maxwellian distribution for kT = 25 keV. This quasi-stellar neutron spectrum allowed us to measure the Maxwellian averaged cross sections directly. The experimental results of {sup 174,176}Yb, {sup 184,186}W, {sup 190,192}Os, {sup 196,198}Pt, and {sup 202}Hg were extrapolated from kT = 25 keV to lower and higher temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Threshold States: Yesterday, Today, Tomorrow

50 years ago exotic nuclear states with abnormally large radii located close to the thresholds of emission of nucleons or clusters were predicted. Recently a hypothesis of possible existence of alpha-particle Bose condensation was proposed. The 0{sup +}{sub 2}(7.65 MeV) state of {sup 12}C(so-called Hoyle state) is considered to be the prototype of such condensed state and have a dilute structure. We propose two methods for searching the alpha-condensate signatures in the Hoyle state and some other ones near the alpha-thresholds by using inelastic diffractive and rainbow scattering. Inelastic scattering of {sup 2}H, {sup 3}He, {sup 4}He, {sup 6}Li, and {sup 12}C on {sup 12}C was studied and the enhancement of the {sup 12}C radius in the Hoyle state relatively the ground state radius by a factor of 1.2 was demonstrated. Another signature of the condensate structure, 70% probability of all three alpha-particles to be in the s-state, was observed for the Hoyle state by studying the {sup 8}Be transfer reaction. The analogs of the Hoyle state with enhanced radii were identified in {sup 11}B and {sup 13}C. The proposed methods of measuring the nuclear radii allowed observation of neutron halos in the excited states of {sup 9}Be and {sup 13}C. The conception of abnormal dimensions of the threshold states finds its confirmation in many nuclear phenomena both well-known and new ones. One of the perspective domains of its manifestation are the nuclei heavier than {sup 100}Sn with N = Z, which are able to emit several alpha particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lasing from the domain of collision of ionisation waves produced due to electric field concentration at electrodes with a small radius of curvature

The characteristics of UV lasing in nitrogen and of diffusive discharge produced without an additional ionisation source were experimentally investigated in a nonuniform electric field formed by electrodes with different profiles. High-voltage nanosecond pulses were applied to the blade- and cylinder-shaped electrodes. It was determined that the gap breakdown at elevated pressure was caused by diffusive jets which propagate from the electrodes with a small radius of curvature. The electric field increased in the intersection of counter-propagating jets, with the effect that the threshold of lasing in the C{sup 3}{Pi}{sub u} - B{sup 3}{Pi}{sub g} ({lambda} = 337.1 nm) molecular nitrogen band was attained for low average electric fields (below 60 V cm{sup -1} Torr{sup -1}) and at pressures of 760 Torr and above. With lowering the pressure from 760 to 20 Torr, the voltage of gap breakdown in the nonuniform electric field was observed to increase for a voltage pulse rise time of {approx}300 ps and to decrease for a pulse rise time of {approx}2 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CORRELATIONS BETWEEN ULTRAHIGH ENERGY COSMIC RAYS AND INFRARED-LUMINOUS GALAXIES

We confirm the ultrahigh energy cosmic ray (UHECR) horizon established by the Pierre Auger Observatory using the heterogeneous Veron-Cetty-Veron (VCV) catalog of active galactic nuclei by performing a redshift-angle-IR luminosity scan using point-source catalog with redshift (PSCz) galaxies having infrared luminosity greater than 10{sup 10} L{sub sun}. The strongest correlation-for z < 0.016, {psi} = 2.{sup 0}1, and L{sub ir} {>=} 10{sup 10.5} L{sub sun}-arises in fewer than 0.3% of scans with isotropic source directions. When we apply a penalty for using the UHECR energy threshold that was tuned to maximize the correlation with VCV, the significance degrades to 1.1%. Since the PSCz catalog is complete and volume-limited for these parameters, this suggests that the UHECR horizon discovered by the Pierre Auger Observatory is not an artifact of the incompleteness and other idiosyncrasies of the VCV catalog. The strength of the correlation between UHECRs and the nearby highest-IR-luminosity PSCz galaxies is stronger than in about 90% of trials with scrambled luminosity assignments for the PSCz galaxies. If confirmed by future data, this result would indicate that the sources of UHECRs are more strongly associated with luminous IR galaxies than with ordinary, lower IR luminosity galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗