THE LHeC ERL – OPTICS AND PERFORMANCE OPTIMIZATION

Unprecedently high luminosity of 1034 cm-2s-1, prom-ised by the LHeC accelerator complex poses several beam dynamics and lattice design challenges. Here we present beam dynamics driven approach to accelerator design, which in particular, addresses emittance dilution due to quantum excitations and beam breakup instability in a large scale, multi-pass Energy Recovery Linac (ERL). The use of ERL accelerator technology to provide im-proved beam quality and higher brightness continues to be the subject of active community interest and active accelerator development of future Electron Ion Colliders (EIC). Here, we employ current state of though for ERLs aiming at the energy frontier EIC. The main thrust of these studies was to enhance the collider performance, while limiting overall power consumption through explor-ing interplay between emittance preservation and effi-ciencies promised by the ERL technology.

Bogacz, Slawomir↗

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

Carrier recombination dynamics and temperature dependent optical properties of InAs–GaSb heterostructures

Heterostructures with two dissimilar materials could offer unprecedented properties if one can carefully synthesize these heterostructures with atomically smooth interfaces and reduced number of recombination centers. InAs/GaSb-based heterostructures have technological importance for long wavelength infrared photodetectors if one can synthesize these materials with high-optical quality and high-carrier lifetime. In this work, the InAs/GaSb heterostructures with a different number of heterointerfaces and growth conditions were grown by solid source molecular beam epitaxy using valved cracker sources for both arsenic and antimony. Precise control of growth parameters and shutter sequences enabled abrupt InAs/GaSb heterointerfaces, as supported by a high-resolution transmission electron microscopic study. The temperature and power-dependent optical properties by photoluminescence (PL) spectroscopic analysis of InAs/GaSb heterostructures with 4 and 28 heterointerfaces displayed donor to the acceptor and the exciton bound to complex defects (V Ga Ga Sb ) 0 . Since the optical transition in PL measurements serves to determine the quality of the material, and the observed excitonic transitions from these InAs/GaSb heterostructures is an indication of high-quality materials. The high-carrier lifetimes of 139 ns to 185 ns from InAs/GaSb heterostructures were measured using microwave photoconductivity decay (μ-PCD) technique at room temperature. The observed increase in carrier lifetime is due to the decreasing number of Ga-related carrier recombination centers or defect complexes. This is further supported by the PL spectroscopic study. In addition, the carrier lifetime with different injection levels is supported by Shockley–Read–Hall recombination. We report these InAs/GaSb heterostructures with high-optical quality and high-carrier lifetimes would offer a path for the development of high-performance infrared photodetectors.

36 MATERIALS SCIENCE↗

Design progress for the 22 GeV CEBAF energy upgrade

In this work we examine the progress made in the design of the proposed FFA upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF). This proposed upgrade will double the number of passes through the two linacs by replacing the two highest energy arcs with new Fixed Field Alternating Gradient (FFA) arcs, roughly doubling the energy. These FFA arcs will use permanent magnets in a Halbach configuration to shape their fields. The design involves new optics for the linacs and remaining electromagnetic arcs, as well as new electromagnetic separators. These feed into the permanent magnet FFA arcs. We also report on ongoing studies of the dynamics of the beams, and an experiment to measure the effects of radiation on the permanent magnets.

Accelerator Physics↗

Development of a position–velocity–time-modulated two-dimensional ion beam figuring system for synchrotron x-ray mirror fabrication

With the rapid evolution of synchrotron x-ray sources, the demand for high-quality precision x-ray mirrors has greatly increased. Single nanometer shape accuracy is required to keep imaging capabilities at the diffraction limit. Ion beam figuring (IBF) has been used frequently for ultra-precision finishing of mirrors, but achieving the ultimate accuracy depends on three important points: careful alignment, accurate dwell time calculation and implementation, and accurate optical metrology. The Optical Metrology Group at National Synchrotron Light Source II has designed and built a position–velocity–time-modulated two-dimensional IBF system (PVT-IBF) with three novel characteristics: (1) a beam footprint on the mirror was used as a reference to align the coordinate systems between the metrology and the IBF hardware; (2) the robust iterative Fourier transform-based dwell time algorithm proposed by our group was applied to obtain an accurate dwell time map; and (3) the dwell time was then transformed to velocities and implemented with the PVT motion scheme. In this study, the technical aspects of the PVT-IBF systems are described in detail, followed by an experimental demonstration of the figuring results. In our first experiment, the 2D RMS in a 50mm×5mm clear aperture was reduced from 3.4 to 1.1 nm after one IBF run. In our second experiment, due to a 5 mm pinhole installed in front of the source, the 2D RMS in a 50mm×5mm clear aperture was reduced from 39.1 to 1.9 nm after three IBF runs, demonstrating that our PVT-IBF solution is an effective and deterministic figuring process.

47 OTHER INSTRUMENTATION↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical tools for a better optical model

Background: Modern statistical tools provide the ability to compare the information content of observables and provide a path to explore which experiments would be most useful to give insight into and constrain theoretical models. Purpose: Here we study three such tools in the context of nuclear reactions with the goal of constraining the optical potential. Method: The three statistical tools examined are (i) the principal component analysis, (ii) the sensitivity analysis based on derivatives, and (iii) the Bayesian evidence. We first apply these tools to a toy-model case, comparing the form of the imaginary part of the optical potential. Then we consider two different reaction observables, elastic angular distributions and polarization data for reactions on 48 Ca and 208 Pb at two different beam energies. Results: For the toy-model case, we find significant discrimination power in the sensitivities and the Bayesian evidence, showing clearly that the volume imaginary term is more useful to describe scattering at higher energies. When comparing between elastic cross sections and polarization data using realistic optical models, sensitivity studies indicate that both observables are roughly equally sensitive but the variability of the optical model parameters is strongly angle dependent. The Bayesian evidence shows some variability between the two observables, but the Bayes factor obtained is not sufficient to discriminate between angular distributions and polarization. Conclusions: From the cases considered, we conclude that, in general, elastic scattering angular distributions have similar impact in constraining the optical potential parameters compared with the polarization data. The angular ranges for the optimum experimental constraints can vary significantly with the observable considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adjoint-optimized nanoscale light extractor for nitrogen-vacancy centers in diamond

Abstract We designed a nanoscale light extractor (NLE) for the efficient outcoupling and beaming of broadband light emitted by shallow, negatively charged nitrogen-vacancy (NV) centers in bulk diamond. The NLE consists of a patterned silicon layer on diamond and requires no etching of the diamond surface. Our design process is based on adjoint optimization using broadband time-domain simulations and yields structures that are inherently robust to positioning and fabrication errors. Our NLE functions like a transmission antenna for the NV center, enhancing the optical power extracted from an NV center positioned 10 nm below the diamond surface by a factor of more than 35, and beaming the light into a ±30° cone in the far field. This approach to light extraction can be readily adapted to other solid-state color centers.

42 ENGINEERING↗

Direct Observations of Sub-micropulse Electron-beam Effects from Short-range Wakefields in TESLA-type Superconducting RF Cavities

The preservation of the low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (FEL) and the under construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range and short-range wakefields (SRW)*. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique two-cavity configuration after the photocathode rf gun. We used optical transition radiation (OTR) imaging with a UV-visible synchroscan streak camera to display sub-micropulse y-t effects in the 41-MeV beam. The head-tail transverse kicks within the 11-ps-long micropulses were observed at the 100-micron level for steering off-axis in one cavity and several 100 microns for two cavities. Since the SRW kick angles go inversely with energy, these results may inform the commissioning plans of the LCLS-II injector where beam will be injected at ~1 MeV into a cryomodule.

43 PARTICLE ACCELERATORS↗

Simultaneous 10 kHz three-dimensional CH 2 O and tomographic PIV measurements in a lifted partially-premixed jet flame

High-speed, three-dimensional (3D) scalar-velocity field measurements are demonstrated in a lifted partially-premixed dimethyl-ether/air jet flame using simultaneous laser-induced fluorescence (LIF) of formaldehyde (CH 2 O) and tomographic particle image velocimetry (TPIV). The 3D LIF measurements are performed by raster scanning the laser beam from a 100 kHz pulse-burst laser across the probe volume using an acousto-optic deflector. The volumetric reconstruction of the LIF signal from ten parallel planes provides quasi-instantaneous 3D LIF measurements that are synchronized with 10 kHz TPIV measurements. Here, the temporally resolved CH 2 O-LIF and velocity field data are used to analyze Lagrangian particle trajectories and displacement speeds at the base of the lifted flame. The particle trajectories reveal flow structures that are difficult to observe in an Eulerian reference frame. Positive and negative displacement speeds are observed at the CH 2 O-LIF surfaces at the inner and outer regions of the jet flame with a maximum displacement speed of approximately eight times the laminar flame speed of a stoichiometric dimethyl-ether/air mixture. The observations in present study support formation of lean premixed flames near the flame base whose role in flame stabilization should be investigated in more detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Design of an amplitude-splitting hard x-ray delay line with subnanoradian stability

We propose the design and analysis of a hard x-ray split-delay optical arrangement that combines diffractive and crystal optics. Transmission gratings are employed to achieve the much-desired amplitude splitting and recombination of the beam. Asymmetric channel-cut crystals are utilized to tune the relative delay time. The use of a dispersion-compensation arrangement of the crystals allows the system to achieve subnanoradian pointing stability during a delay scan. It further minimizes wavefront distortion and preserves the pulse front and pulse duration. We analyze the performance of a prototype design that can cover a delay time range of 15 ps with a sub-20 fs time resolution at 10 keV. We anticipate that this system can fully satisfy the very demanding stability requirements for performing split-pulse x-ray photon correlation spectroscopy measurements for the investigation of fast atomic scale dynamics in complex disordered matter.

47 OTHER INSTRUMENTATION↗

Characterization and Simulation of Optical Delay System for the Proof-of-Principle Experiment of Optical Stochastic Cooling at IOTA

The Optical Stochastic Cooling (OSC) experiment at Fermilab’s IOTA storage ring uses two undulators to cool the beam over many turns. The radiation emitted by electrons in the first undulator is delayed and imaged in the second undulator where it applies a corrective energy kick on the electrons. Imperfections in the manufacturing of the delay plates can lead to a source of error. This paper presents the experimental characterization of the absolute thickness of these delay plates using an interferometric technique. The measured "thickness maps" are implemented in the Synchrotron Radiation Workshop (SRW) program to assess their impact on the delayed radiation pulse.

43 PARTICLE ACCELERATORS↗

Measuring Orbit Responses with Oscillating Trajectories in the Fermilab Linac

Recording changes in beam transverse positions re-ported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector (orbit response) is a powerful tool for analysis of accelerator optics and assisting with machine tuning. In the Fermilab Linac, orbit responses are recorded by oscillating the currents of up to 19 correctors, providing faster, drift-resistant measurements through frequency-domain analysis. This report describes the technique, including error estimations and consistency checks and shows an example of the measurements.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗