Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Diagnostic system for studying generation of subterahertz radiation during beam-plasma interaction in the GOL-3 facility

The design principles and construction of the subterahertz radiometric spectral systems developed for the GOL-3 facility are described. The spectral systems are designed according to the quasi-optical scheme and use multilayer filters based on frequency-selective surfaces. The design and manufacturing technology of such elements are discussed. The results of measuring subterahertz radiation of plasma at the frequency close to the double plasma frequency are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-type quantum-dot-array diffraction grating

A novel phase-type quantum-dot-array diffraction grating (QDADG) is reported. In contrast to an earlier amplitude-type QDADG [C. Wang et al., Rev. Sci. Instrum. 78, 053503 (2007)], the new phase-type QDADG would remove the zeroth order diffraction at some certain wavelength, as well as suppressing the higher-order diffractions. In this paper, the basic concept, the fabrication, the calibration techniques, and the calibration results are presented. Such a grating can be applied in the research fields of beam splitting, laser probe diagnostics, and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory Calibrations of Fe xii–xiv Line-Intensity Ratios for Electron Density Diagnostics

In this work, we have used an electron beam ion trap to measure electron-density-diagnostic line-intensity ratios for extreme ultraviolet lines from Fe xii, xiii, and xiv at wavelengths of ≈185–205 and 255–276 Å. These ratios can be used as density diagnostics for astrophysical spectra and are especially relevant to solar physics. We found that density diagnostics using the Fe xiii 196.53/202.04 and the Fe xiv 264.79/274.21 and 270.52A/274.21 line ratios are reliable using the atomic data calculated with the Flexible Atomic Code (FAC). On the other hand, we found a large discrepancy between the FAC theory and experiment for the commonly used Fe xii (186.85 + 186.88)/195.12 line ratio. These FAC theory calculations give results similar to the data tabulated in CHIANTI, which are commonly used to analyze solar observations. Our results suggest that the discrepancies seen between solar coronal density measurements using the Fe xii (186.85 + 186.88)/195.12 and Fe xiii 196.54/202.04 line ratios are likely due to issues with the atomic calculations for Fe xii.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emittance of positron beams produced in intense laser plasma interaction

The first measurement of the emittance of intense laser-produced positron beams has been made. The emittance values were derived through measurements of positron beam divergence and source size for different peak positron energies under various laser conditions. For one of these laser conditions, we used a one dimensional pepper-pot technique to refine the emittance value. The laser-produced positrons have a geometric emittance between 100 and 500 mm{center_dot}mrad, comparable to the positron sources used at existing accelerators. With 10{sup 10}-10{sup 12} positrons per bunch, this low emittance beam, which is quasi-monoenergetic in the energy range of 5-20 MeV, may be useful as an alternative positron source for future accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using solenoid as multipurpose tool for measuring beam parameters

Solenoids are frequently used for focusing low-energy beams. In this paper, we show how they can serve as multipurpose diagnostics tools to measure various beam parameters, including energy, emittance, the second moments of the transverse distribution, and the beam position and angle with respect to the solenoid’s axis. The energy measurement is based on rotation of the plane of the transverse motion, as opposed to generating dispersion with a dipole. Measurement of the beam trajectory with respect to the solenoid axis is done by analyzing the beam orbit downstream of the solenoid while varying its current. The second moments are calculated by analyzing the beam image on a profile monitor while accounting for the beam rotation caused by the solenoid. We describe in detail the corresponding procedures and the experimental results of these measurements.

43 PARTICLE ACCELERATORS↗

PIP-II Injector Test Warm Front End: Commissioning Update [Slides]

The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test (PIP2IT) at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole magnet, a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) with various diagnostics and a dump. This report presents the commissioning status, focusing on beam measurements in the MEBT. In particular, a beam with the parameters required for injection into the Booster (5 mA, 0.55 ms macro-pulse at 20 Hz) was transported through the WFE.

43 PARTICLE ACCELERATORS↗

PIP-II Injector Test Warm Front End: Commissioning Update

The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test [1] at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole magnet, a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) with various diagnostics and a dump. This report presents the commissioning status, focusing on beam measurements in the MEBT. In particular, a beam with the parameters required for injection into the Booster (5 mA, 0.55 ms macro-pulse at 20 Hz) was transported through the WFE.

43 PARTICLE ACCELERATORS↗

First step toward a synthetic diagnostic for magnetic fluctuation measurements using cross-polarization scattering on DIII-D

Cross-polarization scattering (CPS) provides localized magnetic fluctuation ($\tilde{B}$) measurements in fusion plasmas based on the process where $\tilde{B}$ scatters electromagnetic radiation into the orthogonal polarization. The CPS system on DIII-D utilizes the probe beam of a Doppler backscattering (DBS) diagnostic combined with a cross-view CPS receiver system, which allows simultaneous density and $\tilde{B}$ measurements with good spatial and wavenumber coverage. The interpretation of the signals is challenging due to the complex plasma propagation of the DBS probe beam and CPS receive beams. A synthetic diagnostic for CPS is therefore essential to interpret data and perform detailed validation tests of non-linear turbulence simulations. This work reports a first step toward a synthetic diagnostic for CPS utilizing GENRAY, a 3-D ray tracing code, to simulate the propagation of the probe and scattered rays. The local $\tilde{B}$ wavenumber is calculated from the local O- and X-mode wavenumbers using the wave vector matching scattering condition. The CPS wavenumber values and spatial locations are determined by a complex consideration that includes the local density and $\tilde{B}$ level, receive antenna pattern and orientation, scattering volume, wavenumber values detected at the various scattering centers, and alignment of the magnetic wave vector with the plane perpendicular to the magnetic field. The issue of a spurious CPS signal due to polarization mismatches for launch and receive is also discussed. It is suggested that simultaneous O- and X-mode DBS measurements should be utilized for better understanding of the CPS signal contamination when the cutoff locations for both polarizations are close.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Beam-Based BPM Calibration

The Alignment Diagnostic System (ADS) of the LCLS undulator system indicates that the 33 undulator quadrupoles have extremely high position stability over many weeks. However, beam trajectory straightness and lasing efficiency degrade more quickly than this. A lengthy Beam Based Alignment (BBA) procedure must be executed every two to four weeks to re-optimize the X-ray beam parameters. The undulator system includes RF cavity Beam Position Monitors (RFBPMs), several of which are utilized by an automatic feedback system to align the incoming electron-beam trajectory to the undulator axis. The beam trajectory straightness degradation has been traced to electronic drifts of the gain and offset of the BPMs used in the beam feedback system. To quickly recover the trajectory straightness, we have developed a fast beam-based procedure to recalibrate the BPMs. This procedure takes advantage of the high-precision monitoring capability of the ADS, which allows highly repeatable positioning of undulator quadrupoles. This report describes the ADS, the position stability of the LCLS undulator quadrupoles, and some results of the new recovery procedure.

43 PARTICLE ACCELERATORS↗

Laser beam delivery at ELI-NP

The Laser Beam Delivery (LBD) system technical design report covers the interface between the High Power Laser System (HPLS) and the experiments, together with the pulse quality management. Here, the laser transport part of the LBD has a number of subsystems as follows: the beam transport lines for the six main outputs of HPLS, the additional short and long pulses and the synchronization system including the timing of the laser pulses with the Gamma Beam System (GBS) and the experiments on femtosecond timescale. Pulse quality management, discussed further here, consist in the generation and delivery of multiple HPLS pulses, coherent combining of the HPLS arms, laser pulse diagnostics on target, laser beam dumps, shutters and output energy adaption.

42 ENGINEERING↗

Space-Charge Effects in Ionization Beam Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

Shiltsev, Vladimir D.↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites applied to radiation shielding

Exposure to high radiation dose in medical diagnostic imaging procedures can lead patients to suffer tissue damaging. However, there are several studies that identify significant dose reduction with the use of radiation protective attenuators, minimizing the delivered dose in the region that covers the main beam, while preserving the diagnostic quality of the generated image. Most radiation attenuator materials are produced from shielding metal containing composites, whose efficiency is the goal of investigations around the world. In this context, polymeric materials were chosen for this investigation in order to provide light-weighted and flexible protective composites, a must in personal protective shielding. Therefore, this work is concerned to the investigation of poly(vinylidene fluoride - try-fluor-ethylene) [P(VDF-TrFE)] copolymers mixed with zirconia nanoparticles. The resulting polymer composites, prepared with 1, 2, 3, 5 and 10 at.% of ZrO{sub 2} nanoparticles, were investigated for application as protective shielding in some interventional radiology procedures. Two variety of composites were produced, one using pure ZrO{sub 2} nanoparticles and the other using sol-gel route with zirconium butoxide as the precursor for zirconium oxide nano-clusters. The P(VDFTrFE)/ ZrO2-MMA polymer composites produced by sol-gel route have provided a much better dispersion of the pure ZrO{sub 2} material into the P(VDF-TrFE) host matrix. UV-Vis and FTIR spectrometry and differential scanning calorimetry (DSC) were used to characterize the composite samples. FTIR data reveal a possible link between the MMA monomers with the P(VDF-TrFE) chain through shared C=O bonds. The radiation shielding characterization was conducted by using a 70 kV x-rays beam which is applicable, for instances, in catheter angiography. The results demonstrate that composites with 10% of ZrO{sub 2}, and only 1.0 mm thick, can attenuate 60% of the x-rays beam. The composite density was evaluated to be 2.20 g/cm{sup 3}. The results indicate that P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites have potential to be investigated as light-weighted and flexible protective shielding for application in some radiological procedures that uses low kilovoltage x-ray beams. (authors)

36 MATERIALS SCIENCE↗

Initial results from the operation of two argon ion generators in the auroral ionosphere

Two argon ion generators have been lofted by sounding rockets in order to investigate ion beam dynamics and beam effects on the ionosphere, and auroral electrodynamics during rocket passage over auroral arcs. The ion generators were on a subpayload that was separated from the main payload early in the flight. The main payload conducted the diagnostic measurements during ion beam operations. Evidence of heating of the ionosphere around the subpayload during each ion beam emission is noted.

Erlandson, R. E.↗

Upconversion of lower-hybrid waves by gyrating ion beams in a plasma

A gyrating ion beam, with ring shape distribution in velocity space, supports negative energy modes near the harmonics of beam gyrofrequency. An investigation of the nonlinear interaction of high-frequency lower-hybrid waves with the negative energy beam cyclotron mode is made. A nonlinear dispersion relation is derived for the coupled modes. It is shown that a gyrating ion beam frequency upconverts the lower-hybrid waves separated by harmonics of the beam gyrofrequency. This process of upconversion may thus provide a tool for the diagnostics of the gyrating ion beams. The process may also be important in the saturation of lower-hybrid waves observed in the auroral zone S3-3 satellite data.

Sharma, O. P.↗

Development of a He{sup -} and He{sup 0} beam source for alpha particle measurement in a burning plasma

Proof of principle experiments of neutral helium beam production for alpha particle diagnostics was carried out on a test stand. Negative helium ions were produced in the Li charge exchange cell, in which stable and long time operation was possible. He{sup -} beam was accelerated to 157 keV. Finally, He{sup 0} beam was successfully produced after the flight in the drift-tube through the auto-electron-detachment process from He{sup -} to He{sup 0}. A neutral beam detector using a pyroelectric device was also developed to measure He{sup 0} beam intensity. The metastable component in the neutral helium beam was found to be less than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗