Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

SHORT AND LONG-TERM FIRE IMPACTS ON HANFORD BARRIER PERFORMANCE

A critical unknown in long-term engineered barrier use is the post-fire hydrologic function where institutional controls are in-tact but there are no resources to implement maintenance activities such as re-planting. This objective of this study was to simulate wild fire on an engineered barrier at the Hanford Site and document the post-fire changes in barrier performance. Soil physical, chemical, and hydrologic conditions; plant floristics and density; and animal use were characterized pre- and post-burn. Fuel load on the surface ranged from 4.7 to 5.71 tons/acre. Fire was initiated by drip torch and measurements of flame height and temperature were made at nine locations on the barrier surface. Flame heights exceeded 30 ft and temperatures ranged from 250 C at 1.5 cm below the surface to over 700 C at 1 m above the surface. Soil organic matter, soil wettability, and hydraulic conductivity all decreased significantly relative to pre-fire conditions. Post-fire samples showed an increase in major soil nutrients, pH, and electrical conductivity measured in 1:1 extracts whereas organic matter decreased. Decreases in wettabilty and organic matter are indicative of conditions more conducive to runoff and soil loss. The results of this study will contribute to a better understanding of post-fire recovery in a post-institutional control environment. This should lead to enhanced stakeholder acceptance regarding the long-term efficacy of ET barriers. This study will also support improvements in the design of ET barriers and performance monitoring systems. Such improvements are needed to best meet the long-term commitment to the safe in-place isolation of waste for hundreds if not thousands of years.

54 ENVIRONMENTAL SCIENCES↗

NEUTRON MULTIPLICITY AND ACTIVE WELL NEUTRON COINCIDENCE VERIFICATION MEASUREMENTS PERFORMED FOR MARCH 2009 SEMI-ANNUAL DOE INVENTORY

The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe) {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TEMPORAL CORRELATIONS BETWEEN OPTICAL AND GAMMA-RAY ACTIVITY IN BLAZARS

We have been using the 0.76 m Katzman Automatic Imaging Telescope (KAIT) at Lick Observatory to optically monitor a sample of 157 blazars that are bright in gamma-rays being detected with high significance (≥10σ) in one year by the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope. We attempt to observe each source on a three-day cadence with KAIT, subject to weather and seasonal visibility. The gamma-ray coverage is essentially continuous. KAIT observations extend over much of the five-year Fermi mission for several objects, and most have >100 optical measurements spanning the last three years. These blazars (flat-spectrum radio quasars and BL Lac objects) exhibit a wide range of flaring behavior. Using the discrete correlation function (DCF), here we search for temporal relationships between optical and gamma-ray light curves in the 40 brightest sources in hopes of placing constraints on blazar acceleration and emission zones. We find strong optical-gamma-ray correlation in many of these sources at time delays of ∼1 to ∼10 days, ranging between –40 and +30 days. A stacked average DCF of the 40 sources verifies this correlation trend, with a peak above 99% significance indicating a characteristic time delay consistent with 0 days. These findings strongly support the widely accepted leptonic models of blazar emission. However, we also find examples of apparently uncorrelated flares (optical flares with no gamma-ray counterpart and gamma-ray flares with no optical counterpart) that challenge simple, one-zone models of blazar emission. Moreover, we find that flat-spectrum radio quasars tend to have gamma-rays leading the optical, while intermediate- and high-synchrotron peak blazars with the most significant peaks have smaller lags/leads. It is clear that long-term monitoring at high cadence is necessary to reveal the underlying physical correlation.

79 ASTRONOMY AND ASTROPHYSICS↗

Activity measurement of Fe 60 through the decay of Co 60 m and confirmation of its half-life

The half-life of the neutron-rich nuclide, 60Fe has been in dispute in recent years. A measurement in 2009 published a value of (2.62 ± 0.04) × 106 years, almost twice that of the previously accepted value from 1984 of (1.49 ± 0.27) × 106 years. This longer half-life was confirmed in 2015 by a second measurement, resulting in a value of (2.50 ± 0.12) × 106 years. All three half-life measurements used the grow-in of the γ-ray lines in 60Ni from the decay of the ground state of 60Co (t1/2=5.27 years) to determine the activity of a sample with a known number of 60Fe atoms. In contrast, the work presented here measured the 60Fe activity directly via the 58.6 keV γ-ray line from the short-lived isomeric state of 60Co (t1/2=10.5 minutes), thus being independent of any possible contamination from long-lived 60gCo. A fraction of the material from the 2015 experiment with a known number of 60Fe atoms was used for the activity measurement, resulting in a half-life value of (2.72 ± 0.16) × 106 years, confirming again the longer half-life. In addition, 60Fe/56Fe isotopic ratios of samples with two different dilutions of this material were measured with Accelerator Mass Spectrometry (AMS) to determine the number of 60Fe atoms. Combining this with our activity measurement resulted in a half-life value of (2.69 ± 0.28) × 106 years, again agreeing with the longer half-life.

Ostdiek, Karen M.↗

A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Draft report on melt point as a function of composition for urania-based systems

This report documents the testing of a urania (UO 2.00 ) sample as a baseline and the attempt to determine the melt point associated with 4 compositions of urania-ceria and urania-neodymia pseudo binaries provided by ORNL, with compositions of 95/5, and 80/20 and of (U/Ce)O 2.00 and (U/Nd)O 2.00 in the newly developed ceramic melt point determination system. A redesign of the system using parts fabricated from tungsten was undertaken in order to help prevent contamination and tungsten carbide formation in the crucibles. The previously developed system employed mostly graphite parts that were shown to react with the sample containment black-body crucible leading to unstable temperature readings and crucible failure, thus the redesign. Measured melt point values of UO 2.00 and U 0.95 Ce 0.05 O 2.00 , U 0.80 Ce 0.20 O 2.00 , U 0.95 Nd 0.05 O 2.00 and U 0.80 Nd 0.20 O 2.00 were measured using a 2-color pyrometer. The value measured for UO 2.00 was consistent with the published accepted value 2845°C±25°C, although a wide range of values has been published by researchers and will be discussed later in the text. For comparison, values obtained from a published binary phase diagram of UO 2 -Nd 2 O 3 were used for comparison with our measure values. No literature melt point values for comparison with the measurements performed in this study were found for (U/Ce)O 2.00 in our stoichiometry range.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of the polarization amplitudes of the Bs -> PhiPhi decay at CDF II

In this thesis we present the first measurement of the polarization amplitudes for the charmless B{sub s} {yields} {phi}{phi} {yields} [K{sup +}K{sup -}][K{sup +}K{sup -}] decay of the B{sub s} meson. The result is achieved using an unbinned Maximum Likelihood fit to the data collected by the Collider Detector at Fermilab (CDF) in Run II (CDFII), in a period starting from March 2001 till April 2008, which corresponds to an integrated luminosity of 2.9 fb{sup -1}. The resulting yield consists of 300 signal events selected by the Two Track Trigger (TTT). Furthermore, our work puts in evidence an original topic, that was never observed until now: an unexpected dependence of the signal acceptance on the proper decay time (t) of the B{sub s} mesons. This specific issue, which is most likely a general feature induced by any signal selection based on the lifetime information, is supposed to be related to the on-line TTT and off-line selections based on the impact parameter. The involved fit, indeed, reproduces the biases observed in large statistics Monte Carlo (MC) samples. The thesis presents the same analysis performed for the B{sub s}{sup 0} {yields} J{psi}{phi} decay as well, which is used as a control sample. The polarizations amplitudes we find are consistent with the published ones; this result contributes to enforce the reliability of the analysis. This work is considered ready to begin the procedure for official approval by the CDF collaboration pending the finalization of the systematic uncertainty which has not yet been fully completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-consistent Color–Stellar Mass-to-light Ratio Relations for Low Surface Brightness Galaxies

The color–stellar mass-to-light ratio relation (CMLR) is a widely accepted tool for estimating the stellar mass (M {sub *}) of a galaxy. However, an individual CMLR tends to give distinct M {sub *} for a same galaxy when it is applied in different bands. Examining five representative CMLRs from the literature, we find that the difference in M {sub *} predicted in different bands from optical to near-infrared by a CMLR is 0.1 ∼ 0.3 dex. Based on a sample of low surface brightness galaxies that covers a wide range of color and luminosity, we therefore recalibrated each original CMLR in r, i, z, J, H, and K bands to give internally self-consistent M {sub *} for a same galaxy. The g–r is the primary color indicator in the recalibrated relations, which show little dependence on red (r–z) or near-infrared (J–K) colors. Additionally, the external discrepancies in the originally predicted γ {sub *} by the five independent CMLRs have been greatly reduced after recalibration, especially in the near-infrared bands, implying that the near-infrared luminosities are more robust in predicting γ {sub *}. For each CMLR, the recalibrated relations provided in this work could produce internally self-consistent M {sub *} from divergent photometric bands, and are extensions of the recalibrations from the Johnson–Cousin filter system by the pioneering work of McGaugh & Schombert to the filter system of the Sloan Digital Sky Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Polycyclic Aromatic Hydrocarbon Emission in Spitzer /IRS Maps. II. A Direct Link between Band Profiles and the Radiation Field Strength

We decompose the observed 7.7 μ m polycyclic aromatic hydrocarbon (PAH) emission complexes in a large sample of over 7000 mid-infrared spectra of the interstellar medium using spectral cubes observed with the Spitzer /IRS-SL instrument. In order to fit the 7.7 μ m PAH emission complex we invoke four Gaussian components, which are found to be very stable in terms of their peak positions and widths across all of our spectra, and subsequently define a decomposition with fixed parameters, which gives an acceptable fit for all the spectra. We see a strong environmental dependence on the interrelationships between our band fluxes—in the H ii regions all four components are intercorrelated, while in the reflection nebulae (RNs) the inner and outer pairs of bands correlate in the same manner as previously seen for NGC 2023. We show that this effect arises because the maps of RNs are dominated by emission from strongly irradiated photodissociation regions, while the much larger maps of H ii regions are dominated by emission from regions much more distant from the exciting stars, leading to subtly different spectral behavior. Further investigation of this dichotomy reveals that the ratio of two of these components (centered at 7.6 and 7.8 μ m) is linearly related to the UV-field intensity (log G {sub 0}). We find that this relationship does not hold for sources consisting of circumstellar material, which are known to have variable 7.7 μ m spectral profiles.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for Supersymmetry in Events with Large Missing Transverse Momentum, Jets, and at Least One Tau Lepton in 7 TeV Proton-Proton Collision Data with the ATLAS Detector

CERN-LHC. Study of events from proton-proton interactions at a centre-of-mass energy of 7 Tev which have final states comprising large missing transverse momentum, jets and at least one hadronically decaying TAU letpton accompanied by zero or one additional light lepton (ELECTRON or MUON). The data sample, collected during 2011, has an integrated luminosity of 4.7 fb-1. In the framework of gauge-mediated SUSY-breaking (GMSB) models, lower limits on the mass scale LAMBDA are determined. Data are presented for four channels comprising single and double TAU production with no extra light leptons and single TAU production with an ELECTRON and with a MUON. The exclusion data are from the combined channels. Acceptances and efficiencies for each channel are tabulated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dimming the Lights: 2D Simulations of Deflagrations of Hybrid C/O/Ne White Dwarfs Using FLASH

The dimmest and most numerous outlier of the Type Ia supernova population, the Type Iax event, is increasingly being found in the results of observational campaigns. There is currently no single accepted model to describe these events. This 2D study explores the viability of modeling Type Iax events as a hybrid C/O/Ne white dwarf progenitor undergoing a deflagration using the multiphysics software FLASH. This hybrid was created using the stellar evolution code MESA, and its C-depleted core and mixed structure have demonstrated lower yields than traditional C/O progenitors in previous deflagration-to-detonation studies. To generate a sample, 30 “realizations” of this simulation were performed, the only difference being the shape of the initial match head used to start the deflagration. Consistent with earlier work, these realizations produce the familiar hot dense bound remnant surrounded by sparse ejecta. Our results indicate that the majority of the star remains unburned (∼70%) and bound (>90%). Our realizations produce total ejecta yields on the order of 10 −2 –10 −1 M ☉ , ejected 56 Ni yields on the order of 10 −4 –10 −2 M ☉ , and ejecta kinetic energies on the order of 10 48 –10 49 erg. Compared to yields inferred from recent observations of the dimmest Type Iax events—SN 2007qd, SN 2008ha, SN 2010ae, SN 2019gsc, SN 2019muj, SN 2020kyg, and SN 2021fcg—our simulation produces comparable 56 Ni yields but too-small total yields and kinetic energies. Reignition of the remnant is also seen in some realizations.

Hydrodynamical simulations↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NON-THERMAL X-RAY EMISSION FROM THE NORTHWESTERN RIM OF THE GALACTIC SUPERNOVA REMNANT G266.2-1.2 (RX J0852.0-4622)

We present a detailed spatially resolved spectroscopic analysis of two observations (with a total integration time of 73280 s) made of the X-ray-luminous northwestern rim complex of the Galactic supernova remnant (SNR) G266.2-1.2 (RX J0852.0-4622) with the Chandra X-ray Observatory. G266.2-1.2 is a member of a class of Galactic SNRs which feature X-ray spectra dominated by non-thermal emission: in the cases of these SNRs, the emission is believed to have a synchrotron origin and studies of the X-ray spectra of these SNRs can lend insight into how SNRs accelerate cosmic-ray particles. The Chandra observations have clearly revealed fine structure in this rim complex (including a remarkably well-defined leading shock) and the spectra of these features are dominated by non-thermal emission. We have measured the length scales of the upstream structures at eight positions along the rim and derive lengths of 0.02-0.08 pc (assuming a distance of 750 pc to G266.2-1.2). We have also extracted spectra from seven regions in the rim complex (as sampled by the ACIS-S2, -S3, and -S4 chips) and fit these spectra with such models as a simple power law as well as the synchrotron models SRCUT and SRESC. We have constrained our fits to the latter two models using estimates for the flux densities of these filaments at 1 GHz as determined from radio observations of this rim complex made with the Australia Telescope Compact Array. Statistically acceptable fits to all seven regions are derived using each model: differences in the fit parameters (such as photon index and cutoff frequency) are seen in different regions, which may indicate variations in shock conditions and the maximum energies of the cosmic-ray electrons accelerated at each region. Finally, we estimate the maximum energy of cosmic-ray electrons accelerated along this rim complex to be approximately 40 TeV (corresponding to one of the regions of the leading shock structure assuming a magnetic field strength of 10 {mu}G). We include a summary of estimated maximum energies for both Galactic SNRs as well as SNRs located in the Large Magellanic Cloud. Like these other SNRs, it does not appear that G266.2-1.2 is currently accelerating electrons to the knee energy ({approx}3000 TeV) of the cosmic-ray spectrum. This result is not surprising, as there is some evidence that loss mechanisms which are not important for the accelerated cosmic-ray nucleons at energies just below the knee might cut off electron acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

Variance components in confocal scanning laser tomography measurements of neuro‐retinal rim area and the effect of repeated measurements on the power to detect loss over time

Abstract Purpose To estimate the variation in measurements of neuro‐retinal rim area (NRA) determined by confocal scanning laser tomography and consequences for clinical follow‐up. Methods Altogether, 24 healthy subjects were randomized on –320 μ m, Moorfields and Standard NRA plane strategies. Additionally, NRA was measured in 32 glaucoma subjects. Variance components for subjects, visits and measurements were estimated with analysis of variance. Sample sizes required to detect a 6.0 × 10 −2 mm 2 NRA change were estimated assuming a significance level of 0.05 and a power of 0.8. Consequences for independent group, and paired comparison design, respectively, were analysed. Further, precision in estimates within subjects over time was investigated. Results The variation of NRA among subjects was considerably larger than the variation among visits and measurements. For glaucoma subjects, the variation among visits and measurements were of the same order but larger than in healthy subjects. It was found that independent group comparisons require inconveniently large sample sizes. Within‐subject paired comparisons over time require sample sizes of below 15 subjects. The estimated variations for glaucoma subjects imply that 54 months of follow‐up is required for detection of change from baseline. Conclusions The variance for subjects is substantial in relation to those for visits and measurements. Cross‐sectional independent group comparisons of levels of NRA are unsuitable, due to considerable subject variation. Levels of NRA differences within subjects between visits can be estimated with acceptable precision. Neuro‐retinal rim area (NRA) measurement can be used for long‐term follow‐up of glaucoma progression.

Sandberg Melin, Camilla↗