Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

SCIFLI HORIS Windowpane Optical Analysis

This NASA Technical Memorandum summarizes windowpane optical analyses for the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification and Security Regolith Explorer) mission [1] supported by the SCIFLI (Scientifically Calibrated In-Flight Imagery) team [2] at NASA Langley Research Center (NASA LaRC). The SCIFLI team led a NASA multi-center team in characterization of fused silica (FS) and anti-reflective coated (AR-coated) sapphire materials for use as aircraft windowpanes. These materials were needed for the Hypervelocity OSIRIS-REx Reentry Imaging & Spectroscopy (HORIS) mission and were tested to generate performance parameters relevant to the flight environment. Some of the assessed parameters included optical quality, transmittance, reflectance, color balance, birefringence, transmitted wavefront error, wedge, and haziness of the windows. In order to evaluate the material characteristics in a uniform manner, several criteria were held constant. For example, the physical dimensions of the test articles were held constant (i.e., 17-inch diameter aircraft windowpane and 2-inch diameter witness samples). In this way, the comparison of test results from one material specimen to another was invariant with regard to the manner in which the tests were conducted. This also reduced the variability in how the data were reported. As a result, the results shown in this report, including test data generated by NASA can be used for windowpane material evaluation and future material design trades. Window designers can use the data and the testing method along with the testing matrices to efficiently match material performance to their design and mission objectives and requirements. Standardized testing methodologies and data reduction procedures are described in this report. Unless otherwise noted in the data itself, all the windowpane materials were tested in order to characterize their performance for the HORIS mission. One appendix has been included in this report. These include detailed wavefront interferograms of transmitted wavefront error and optical wedge used in the generation of aggregated material performance.

SCIFLI↗

Improved ultraviolet resonance lamp

Removal of the seal area from the path of the lamp discharge eliminates the gradual deterioration of lithium fluoride window surfaces from condensation of products formed by interaction of a resonant rare-gas discharge with window sealing materials. The discharge is confined to the inner tube.

Bass, A. M.↗

Optical enhancement of photomultiplier sensitivity

Transmission and reflection light losses are reduced by introducing light into end-window of device at an angle large enough to normal so total internal reflection occurs at both photocathode-vacuum and window-air interfaces.

Grant, G. R.↗

Photoionization measurement study

An analysis was conducted of a gas window photoionization device for studying cosmic X-rays in the region 20 eV to 1 keV. The detecting element is an argon proportional counter whose window is a two-dimensional supersonic gas jet. Spectroscopic features of the incoming radiation can be determined by the choice of gas forming the jet (as well by the fluid dynamic parameters of the flow). The choice of gas can be made from pure substances and/or compounds with Z between 1 and 10. The counter walls can be prepared for selective analysis of the extreme ultraviolet radiation.

Sandri, G.↗

Detonation of insensitive high explosives by a Q-switched ruby laser.

Immediate longitudinal detonations have been observed in confined small-diameter columns of PETN, RDX, and tetryl by using a focused Q-switched ruby laser. The energy ranged from 0.8 to 4.0 J in a pulse width of 25 nsec. A 1000-A-thick aluminum film deposited on a glass window was used to generate a shock wave at the window-explosive interface when irradiated by the laser. In some cases, steady-state detonations were reached in less than .5 microsec with less than 10% variation in the detonation velocity.

Yang, L. C.↗

Performance characteristics of proximity focused ultraviolet image converters

Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for ultraviolet to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs - Te photocathodes, and P-11 phosphors on fiber optic output windows.

Williams, J. T.↗

Ultraviolet proximity focussed converters for use in a satellite SEC-TV system.

Performance characteristics of Bendix type BX08025-4522 proximity-focussed vacuum-ultraviolet to visible-light image converters are presented. The converters are to be used with SEC vidicons as detectors for an echelle spectrograph on the International Ultraviolet Explorer astronomical satellite. Magnesium fluoride input windows with Cs-Te photocathodes are used in the converters, with P-11 phosphors on the fiber optic output windows. Quantum efficiencies, modulation transfer function, background, geometric distortion, and environmental test results are presented for the wavelength region from 1150 to 3500 A.-

Feibelman, W. A.↗

A visual display system approach for an advanced spaceflight simulator.

Future training and procedures simulators for advanced spacecraft will require that visual attachments provide forward, side and overhead window field of view capability. This paper presents an approach to high resolution, full color simulation of visual cues over the field of view offered by these crew station windows. Baseline requirements along with supporting rationale are presented. Candidate visual display hardware is identified and trade study results discussed. The display system approach presented is the result of studies which investigated the applicability of Apollo simulator visual display and image generation hardware to advanced spaceflight simulation.

Hock, E. A.↗

Inspection of transparent surfaces using photosensitive paper

Window surface is laid flat on top of photosensitive paper. Opposite side of glass is covered by black cloth. Window edges are then illuminated by light flash through fiber optics. Exposed paper is processed and inspected. Paper shows scratches, bubbles, dust particles, and fingerprints on glass surface.

Minton, F. R.↗

A compilation and analysis of typical approach and landing data for a simulator study of an externally blown flap STOL aircraft

A piloted simulation study has been made of typical landing approaches with an externally blown flap STOL aircraft to ascertain a realistic dispersion of parameter values at both the flare window and touchdown. The study was performed on a fixed-base simulator using standard cockpit instrumentation. Six levels of stability and control augmentation were tested during a total of 60 approaches (10 at each level). A detached supplement containing computer printouts of the flare-window and touchdown conditions for all 60 runs has been prepared.

Middleton, D. B.↗

Flight investigation of approach and flare from simulated breakout altitude of a subsonic jet transport and comparison with analytical models

Satisfactory and optimum flare windows are defined from pilot ratings and comments. Maximum flare normal accelerations, touchdown rates of sink, and total landing maneuver time increments are summarized as a function of approach airspeed margin (with respect to reference airspeed) and flare initiation altitude. The effects of two thrust management techniques are investigated. Comparisons are made with predictions from three analytical models and the results of a simulator study. The approach speed margin was found to have a greater influence on the flare initiation altitude than the absolute airspeed. The optimum airspeed was between the reference airspeed and the reference airspeed plus 10 knots. The optimum flare initiation altitude range for unrestricted landings was from 11 meters to 20 meters (36 feet to 66 feet), and the landing time in the optimum window was 8 seconds. The duration of the landing maneuver increased with increasing flare initiation altitude and with increasing speed margins on the approach.

Matheny, N. W.↗

Development and evaluation of television tubes for space astronomy

An improved vidicon image sensor for space astronomy applications is developed that features reliably sealed ultraviolet transmitting windows and achieves acceptable photocathode quantum efficiency on these MgF2 windows. New preamplifier designs improve the dynamic range by reduction of the readout noise.

Spitzer, L.↗

Apparatus for controlling the temperature of balloon-borne equipment

A novel apparatus for controlling the temperature of balloon-borne equipment is disclosed, the apparatus serving to utilize the radiant energy emitted by the earth and its atmosphere so as to control the temperature of equipment. The apparatus comprises a housing to be carried aloft by a balloon and defining an enclosure for an instrumentation package. The enclosure includes an upper shield portion as well as a bottom window portion at the base, the bottom window facing the earth below during flight. The upper shield portion is constructed of a material such as aluminized Mylar, which serves to reflect direct sunlight.

Schach, M.↗

The geographical distribution of difference 100-keV electrons above the earth's atmosphere

Modern soft X-ray astronomical observations are made with large-area proportional counters that have very thin plastic windows. The counters are consequently very sensitive to low energy electrons. An electron with only a few keV of energy can penetrate a typical window, and a flux of approximately 100 electrons per square centimeter sec-ster can double the background counting rate during a typical observation. These electrons produce an undersiable effect which, is impossible to distinguish from X ray data. Consequently, an electron-free region is needed for accurate astronomical observations. Geographical regions of weak electron flux from low altitude satellite data are derived. These regions can be compared with the locations of rocket launching sites. The best sites should be those farthest from electron regions.

Seward, F. D.↗

Soft X-ray bremsstrahlung and fluorescent line production in the atmosphere by low energy electrons

The effect of low energy quasi-trapped or precipitating electrons which impact on the counter windows of soft X-ray detectors are discussed. The errors caused by X-rays produced in the residual atmosphere above a rocket-borne detector because of the resemblance to X-rays of cosmic origin are examined. The design and development of counter windows which make it possible to identify the atmospherically produced X-rays are described. Curves are presented to show the following: (1) preliminary low energy electron data from Atmospheric Explorer C, (2) X-ray flux in electron-excited nitrogen and oxygen, (3) typical proportional counter response to low energy cosmic rays, and (4) proportional counter response to X-radiation produced by electrons incident upon a gas of oxygen to nitrogen number of 0.4.

Kraushaar, W. L.↗

Information content of IRIS spectra

Spectra from the satellite instrument IRIS (infra red interferometer spectrometer) were examined to find the number of independent variables needed to describe these broadband high spectral resolution data. The radiated power in the atmospheric window from 771 to 981/cm was the first parameter chosen for fitting observed spectra. At succeeding levels of analysis the residual variability (observed spectrum - best fit spectrum) in an ensemble of observations was partioned into spectral eigenvectors. The eigenvector describing the largest fraction of this variability was examined for a strong spectral signature; the power in the corresponding spectral band was then used as the next fitting parameter. The measured power in nine spectral intervals, when inserted in the spectral fitting functions, was adequate to describe most spectra to within the noise level of IRIS. Considerations of relative signal strength and scales of atmospheric variability suggest a combination sounder (multichannel-broad field of view) scanner (window channel-small field of view) as an efficient observing instrument.

Price, J. C.↗

Apollo-Skylab contamination photography (S226)

Photographs taken on Apollo 16 before, during, and after a water dump were analyzed for residual background brightness, particle dynamics, and time decay of background brightness. No conclusive results were obtained because of the illumination of the windows or window openings by extraneous light sources.

Craven, P. D.↗